X-Git-Url: https://git.proxmox.com/?a=blobdiff_plain;f=pve-system-requirements.adoc;h=0a4ba6cd6e3215d6209f789320d46d820361692d;hb=c78cd2b6ee129f0901ade2bf1d2f16ee6e5c39dd;hp=19ddd2c82d5264d50c4c05531bcb7207cae0c258;hpb=fcace69a97d95b597ae69d62c06ca4e68709b426;p=pve-docs.git diff --git a/pve-system-requirements.adoc b/pve-system-requirements.adoc index 19ddd2c..0a4ba6c 100644 --- a/pve-system-requirements.adoc +++ b/pve-system-requirements.adoc @@ -1,6 +1,8 @@ System Requirements ------------------- -include::attributes.txt[] +ifdef::wiki[] +:pve-toplevel: +endif::wiki[] For production servers, high quality server equipment is needed. Keep in mind, if you run 10 Virtual Servers on one machine and you then @@ -9,9 +11,9 @@ supports clustering, this means that multiple {pve} installations can be centrally managed thanks to the included cluster functionality. {pve} can use local storage (DAS), SAN, NAS and also distributed -storage (Ceph RBD). For details see xref:chapter-storage[chapter storage]. - +storage (Ceph RBD). For details see xref:chapter_storage[chapter storage]. +[[install_minimal_requirements]] Minimum Requirements, for Evaluation ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ @@ -26,21 +28,30 @@ Minimum Requirements, for Evaluation * One NIC +[[install_recommended_requirements]] Recommended System Requirements ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ -* CPU: 64bit (Intel EMT64 or AMD64), Multi core CPU recommended +* Intel EMT64 or AMD64 with Intel VT/AMD-V CPU flag. -* Intel VT/AMD-V capable CPU/Mainboard for KVM Full Virtualization support +* Memory, minimum 2 GB for OS and Proxmox VE services. Plus designated memory + for guests. For Ceph or ZFS additional memory is required, approximately 1 GB + memory for every TB used storage. + +* Fast and redundant storage, best results with SSD disks. -* RAM: 8 GB RAM, plus additional RAM used for guests +* OS storage: Hardware RAID with batteries protected write cache (``BBU'') or + non-RAID with ZFS and SSD cache. -* Hardware RAID with batteries protected write cache (``BBU'') or flash - based protection +* VM storage: For local storage use a hardware RAID with battery backed + write cache (BBU) or non-RAID for ZFS. Neither ZFS nor Ceph are compatible + with a hardware RAID controller. Shared and distributed storage is also + possible. -* Fast hard drives, best results with 15k rpm SAS, Raid10 +* Redundant Gbit NICs, additional NICs depending on the preferred storage + technology and cluster setup – 10 Gbit and higher is also supported. -* At least two NICs, depending on the used storage technology you need more +* For PCI passthrough a CPU with VT-d/AMD-d CPU flag is needed. Simple Performance Overview @@ -59,10 +70,8 @@ To use the web interface you need a modern browser, this includes: * Firefox, a release from the current year, or the latest Extended Support Release * Chrome, a release from the current year -* the Microsoft currently supported versions of Internet Explorer (as -of 2016, this means IE 11 or IE Edge) -* the Apple currently supported versions of Safari (as of 2016, this -means Safari 9) +* Microsofts currently supported version of Edge +* Safari, a release from the current year If {pve} detects you're connecting from a mobile device, you will be redirected to a lightweight touch-based UI.