This means that the voltage range is not linear and so RK805 can not
reuse the same regulator_ops structure from RK808.
Fix it by creating a list with the correct supported voltage values
for RK805 BUCK1 and BUCK2 regulators.
Tested on a rv1108-elgin-r1 board that now correctly reports a BUCK2
voltage of 2.2V instead of the unsupported value of 1.4875V.
Fixes: c4e0d344c1f0 ("regulator: rk808: Add regulator driver for RK805") Signed-off-by: Otavio Salvador <otavio@ossystems.com.br> Signed-off-by: Mark Brown <broonie@kernel.org>