]> git.proxmox.com Git - mirror_ubuntu-hirsute-kernel.git/commitdiff
staging: comedi: das08: clarify sign-magnitude conversion
authorIan Abbott <abbotti@mev.co.uk>
Fri, 5 Jun 2015 17:30:34 +0000 (18:30 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sat, 13 Jun 2015 00:06:42 +0000 (17:06 -0700)
For DAS08/JR/16 and DAS08/JR/AO-16 boards, the 16-bit analog input
readings are assumed to be in a sign-magnitude format and need
converting to the COMEDI unsigned sample format.  The expressions to do
the conversion look a little messy.  Use a local variable `magnitude` to
make it easier to follow.

Also, there seems to be some discrepancy between the manual for these
boards and the COMEDI code.  The manual implies that 0 is full-scale
negative and 65535 is full-scale positive.  However, the COMEDI code has
used the sign-magnitude conversion for these boards since these two
boards were initially supported by a patch from an external contributor
to the COMEDI project back in 2001.  Assume the code is correct for now,
but add a comment to mention the discrepancy.

Signed-off-by: Ian Abbott <abbotti@mev.co.uk>
Reviewed-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/comedi/drivers/das08.c

index f74c4b009d8b1c9b5536909d40d2d11f27d0ada3..6c9bd10243b7154e4f3c36907c3d674ce70fed75 100644 (file)
@@ -228,11 +228,26 @@ static int das08_ai_insn_read(struct comedi_device *dev,
                } else if (thisboard->ai_encoding == das08_pcm_encode12) {
                        data[n] = (msb << 8) + lsb;
                } else if (thisboard->ai_encoding == das08_encode16) {
-                       /* FPOS 16-bit boards are sign-magnitude */
+                       /*
+                        * "JR" 16-bit boards are sign-magnitude.
+                        *
+                        * XXX The manual seems to imply that 0 is full-scale
+                        * negative and 65535 is full-scale positive, but the
+                        * original COMEDI patch to add support for the
+                        * DAS08/JR/16 and DAS08/JR/16-AO boards have it
+                        * encoded as sign-magnitude.  Assume the original
+                        * COMEDI code is correct for now.
+                        */
+                       unsigned int magnitude = lsb | ((msb & 0x7f) << 8);
+
+                       /*
+                        * MSB bit 7 is 0 for negative, 1 for positive voltage.
+                        * COMEDI 16-bit bipolar data value for 0V is 0x8000.
+                        */
                        if (msb & 0x80)
-                               data[n] = (1 << 15) | lsb | ((msb & 0x7f) << 8);
+                               data[n] = (1 << 15) + magnitude;
                        else
-                               data[n] = (1 << 15) - (lsb | (msb & 0x7f) << 8);
+                               data[n] = (1 << 15) - magnitude;
                } else {
                        dev_err(dev->class_dev, "bug! unknown ai encoding\n");
                        return -1;