As the man page for tc netem states:
To use the Bernoulli model, the only needed parameter is p while the
others will be set to the default values r=1-p, 1-h=1 and 1-k=0.
However r parameter is erroneusly set to 1, and not to 1-p.
Fix this using the same approach of the 4-state loss model.
Fixes: 3c7950af598be ("netem: add support for 4 state and GE loss model")
Signed-off-by: Andrea Claudi <aclaudi@redhat.com>
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
}
} else if (!strcmp(*argv, "gemodel")) {
+ double p;
+
NEXT_ARG();
- if (get_percent(&gemodel.p, *argv)) {
+ if (parse_percent(&p, *argv)) {
explain1("loss gemodel p");
return -1;
}
+ set_percent(&gemodel.p, p);
/* set defaults */
- set_percent(&gemodel.r, 1.);
+ set_percent(&gemodel.r, 1. - p);
set_percent(&gemodel.h, 0);
set_percent(&gemodel.k1, 0);
loss_type = NETEM_LOSS_GE;