The hardware manual states that the operation of the sensor is not
guaranteed outside the range of -45°C to 125°C, not that the readings
are invalid. Remove the bound check and try to deliver temperature
readings even if we are outside the guaranteed operation range.
Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20200117160554.3812787-2-niklas.soderlund+renesas@ragnatech.se
tmp = MCELSIUS((priv->ctemp * 5) - 60);
mutex_unlock(&priv->lock);
- if ((tmp < MCELSIUS(-45)) || (tmp > MCELSIUS(125))) {
- struct device *dev = rcar_priv_to_dev(priv);
-
- dev_err(dev, "it couldn't measure temperature correctly\n");
- return -EIO;
- }
+ /* Guaranteed operating range is -45C to 125C. */
*temp = tmp;