From 2265cef2751b3441df91f85e0107f9f549e5b711 Mon Sep 17 00:00:00 2001 From: Jean Delvare Date: Fri, 4 Nov 2011 12:00:47 +0100 Subject: [PATCH] hwmon: (w83627ehf) Properly report PECI and AMD-SI sensor types When temperature sources are PECI or AMD-SI agents, it makes no sense to report their type as diode or thermistor. Instead we must report their digital nature. Signed-off-by: Jean Delvare Cc: stable@kernel.org Acked-by: Guenter Roeck --- drivers/hwmon/w83627ehf.c | 9 ++++++++- 1 file changed, 8 insertions(+), 1 deletion(-) diff --git a/drivers/hwmon/w83627ehf.c b/drivers/hwmon/w83627ehf.c index 98aab4bea342..9354f9541313 100644 --- a/drivers/hwmon/w83627ehf.c +++ b/drivers/hwmon/w83627ehf.c @@ -1812,7 +1812,14 @@ static inline void __devinit w83627ehf_init_device(struct w83627ehf_data *data, diode = 0x70; } for (i = 0; i < 3; i++) { - if ((tmp & (0x02 << i))) + const char *label = data->temp_label[data->temp_src[i]]; + + /* Digital source overrides analog type */ + if (strncmp(label, "PECI", 4) == 0) + data->temp_type[i] = 6; + else if (strncmp(label, "AMD", 3) == 0) + data->temp_type[i] = 5; + else if ((tmp & (0x02 << i))) data->temp_type[i] = (diode & (0x10 << i)) ? 1 : 3; else data->temp_type[i] = 4; /* thermistor */ -- 2.39.5