bd63012c |
1 | @REM @file\r |
2 | @REM Windows batch file, Edk2Setup.bat, to set up an EDK II build environment\r |
3 | @REM\r |
4 | @REM This script will be renamed to edksetup.bat after initial testing and\r |
5 | @REM acceptance by the open source community.\r |
6 | @REM\r |
7 | @REM This script will set the following system environment variables:\r |
8 | @REM WORKSPACE, EDK_TOOLS_PATH, PATH\r |
9 | @REM If rebuilding the tools:\r |
10 | @REM BASE_TOOLS_PATH, PYTHON_FREEZER_PATH, PYTHONPATH\r |
11 | @REM It will also create a Conf/target.txt, tools_def.txt and build_rule.txt files\r |
12 | @REM if they do not exist\r |
13 | @REM If the reset flag is set, all environment variables will be reset and \r |
14 | @REM the Conf/target.txt, tools_def.txt and build_rule.txt files will be overwritten\r |
15 | @REM\r |
16 | @REM Three other scripts, located in the BaseTools\Scripts directory, may be called\r |
17 | @REM by this script.\r |
18 | @REM SetVisualStudio.bat - will set the Visual Studio environment based on the --vs* flags\r |
19 | @REM it is also used to build the Win32 binaries, calling nmake \r |
20 | @REM using the WORKSPACE\BaseTools\Makefile\r |
21 | @REM ShowEnvironment.bat - will display the current EDK II Build environment\r |
22 | @REM UpdateBuildVersions.py - script is called prior to building the EDK II BaseTools from\r |
23 | @REM Sources. This tool will modify the BuildVersion.* files so that\r |
24 | @REM when the tools get built, they will have a custom version entry\r |
25 | @REM similar to the following:\r |
26 | @REM e:\edk2>build --version\r |
27 | @REM build.exe Version 0.51 Developer Build based on Revision: 15668\r |
28 | @REM\r |
29 | @REM Copyright (c) 2014, Intel Corporation. All rights reserved.<BR>\r |
30 | @REM This program and the accompanying materials\r |
31 | @REM are licensed and made available under the terms and conditions of the BSD License\r |
32 | @REM which accompanies this distribution. The full text of the license may be found at\r |
33 | @REM http://opensource.org/licenses/bsd-license.php\r |
34 | @REM\r |
35 | @REM THE PROGRAM IS DISTRIBUTED UNDER THE BSD LICENSE ON AN "AS IS" BASIS,\r |
36 | @REM WITHOUT WARRANTIES OR REPRESENTATIONS OF ANY KIND, EITHER EXPRESS OR IMPLIED.\r |
37 | @REM\r |
38 | @REM\r |
39 | @REM usage:\r |
40 | @REM Edk2Setup.bat [--help | -h] [-v | --version] [-r | --reset] \r |
41 | @REM [--reconfig] [--edk-tools-path DirName]\r |
42 | @REM [--pull [Directory]| --rebuild [Directory]]\r |
43 | @REM [--nt32 [X64]]\r |
44 | \r |
45 | @REM ##############################################################\r |
46 | @REM # You should not have to modify anything below this line\r |
47 | @REM #\r |
48 | @echo off\r |
49 | @set SCRIPT_NAME=%0\r |
83185c5a |
50 | @set SCRIPT_VERSION=0.9.2.\r |
51 | @set SVN_REVISION=$Revision$\r |
bd63012c |
52 | @set RESET_ENVIRONMENT=FALSE\r |
53 | @set NT32PKG=FALSE\r |
54 | @set NT32_64=FALSE\r |
55 | @set BUILD_TOOLS_WITH=\r |
56 | @set LOCATION=\r |
57 | @set REBUILD_TOOLS=\r |
58 | @set SVN_PULL=\r |
59 | @set SRC_CONF=\r |
60 | @set ARGUMENT=\r |
61 | @set SCRIPT=EDKSETUP_BAT\r |
62 | \r |
63 | @if not defined ORIGINAL_PATH set "ORIGINAL_PATH=%PATH%"\r |
64 | @REM Always set the WORKSPACE environment variable to the current directory\r |
65 | @set "WORKSPACE=%CD%"\r |
66 | @if exist "%WORKSPACE%\BaseTools" @set "BASE_TOOLS_PATH=%WORKSPACE%\BaseTools"\r |
67 | @if not exist "%WORKSPACE%\Conf" @mkdir "%WORKSPACE%\Conf"\r |
68 | \r |
69 | @@if not defined EDK_TOOLS_PATH @set "EDK_TOOLS_PATH=%WORKSPACE%\BaseTools"\r |
70 | @rem @set "PATH=%WORKSPACE%\BaseTools\Bin\Win32;%PATH%"\r |
71 | @rem @set WORKSPACE_TOOLS_PATH=%WORKSPACE%\BaseTools\r |
72 | @rem )\r |
73 | \r |
74 | @REM Keep the existing EDK_TOOLS_PATH value, the --reset flag will set it\r |
75 | @REM back to WORKSPACE\BaseTools while the --location DIRECTORY flag will\r |
76 | @REM still take precedence if the location option follows the reset option\r |
77 | @REM on the command line.\r |
78 | @if defined EDK_TOOLS_PATH @set "LOCATION=%EDK_TOOLS_PATH%"\r |
79 | \r |
80 | :parse_cmd_line\r |
81 | @if "%1"=="" @goto MainRoutine\r |
82 | @if /I "%1"=="-h" @goto Usage\r |
83 | @if /I "%1"=="--help" @goto Usage\r |
84 | @if /I "%1"=="/?" @goto Usage\r |
85 | @if /I "%1"=="--version" @goto Version\r |
86 | \r |
87 | @REM These options will reset the system environment\r |
88 | @if /I "%1"=="-r" (\r |
89 | @setlocal EnableDelayedExpansion\r |
90 | @set "WORKSPACE=%CD%"\r |
91 | @set "EDK_TOOLS_PATH=%CD%\BaseTools"\r |
92 | @set "LOCATION=!EDK_TOOLS_PATH!"\r |
93 | @endlocal\r |
94 | @shift\r |
95 | @goto parse_cmd_line\r |
96 | )\r |
97 | @if /I "%1"=="--reset" (\r |
98 | @set "WORKSPACE=%CD%"\r |
99 | @set "EDK_TOOLS_PATH=%WORKSPACE%\BaseTools"\r |
100 | @set "LOCATION=%WORKSPACE%\BaseTools"\r |
101 | @shift\r |
102 | @goto parse_cmd_line\r |
103 | )\r |
104 | \r |
105 | @REM This option is used to overwrite the Conf/*.txt files with the\r |
106 | @REM WORKSPACE\BaseTools\Conf\*.template files.\r |
107 | @if /I "%1"=="--reconfig" (\r |
108 | @set RECONFIG=TRUE\r |
109 | @shift\r |
110 | @goto parse_cmd_line\r |
111 | )\r |
112 | \r |
113 | @REM This option can be used to set the EDK_TOOLS_PATH containing the Win32 binaries to an\r |
114 | @REM alternate directory\r |
115 | @if /I "%1"=="--edk-tools-path" (\r |
116 | @setlocal EnableDelayedExpansion\r |
117 | @set ARGUMENT=%2\r |
118 | @if "!ARGUMENT:~0,2!"=="--" (\r |
119 | @echo.\r |
120 | @echo ERROR : The --edk-tools-path flag requires an argument\r |
121 | @echo.\r |
122 | @endlocal\r |
123 | @goto Usage\r |
124 | )\r |
125 | @endlocal\r |
126 | @set "LOCATION=%WORKSPACE%\%2"\r |
127 | @shift\r |
128 | @shift\r |
129 | @goto parse_cmd_line\r |
130 | )\r |
131 | \r |
132 | @REM Force pulling updated (or checkout if they do not exist) from SVN for the BaseTools\Bin\Win32 directory\r |
133 | @REM or the directory pointed to by the --location option\r |
134 | @if /I "%1"=="--pull" (\r |
135 | @if "%REBUILD_TOOLS%"=="TRUE" (\r |
136 | @echo.\r |
137 | @echo ERROR: The --pull option may not be used with the --rebuild option\r |
138 | @shift\r |
139 | @goto ExitFailure\r |
140 | )\r |
141 | @set SVN_PULL=TRUE\r |
142 | @setlocal EnableDelayedExpansion\r |
143 | @set ARGUMENT=%2\r |
144 | @if not "!ARGUMENT:~0,2!"=="--" (\r |
145 | @endlocal\r |
146 | @set "LOCATION=%2"\r |
147 | @shift\r |
148 | )\r |
149 | @shift\r |
150 | @goto parse_cmd_line\r |
151 | )\r |
152 | \r |
153 | @REM This options forces rebuilding the tools (provided the required tools are available\r |
154 | @if /I "%1"=="--rebuild" (\r |
155 | @if "%SVN_PULL%"=="TRUE" (\r |
156 | @echo.\r |
157 | @echo ERROR: The --reset option may not be used with the --pull option\r |
158 | @shift\r |
159 | @goto ExitFailure\r |
160 | )\r |
161 | @set REBUILD_TOOLS=TRUE\r |
162 | @setlocal EnableDelayedExpansion\r |
163 | @set ARGUMENT=%2\r |
164 | @if not "!ARGUMENT:~0,2!"=="--" (\r |
165 | @endlocal\r |
166 | @set "LOCATION=%2"\r |
167 | @shift\r |
168 | )\r |
169 | @shift\r |
170 | goto parse_cmd_line\r |
171 | )\r |
172 | \r |
173 | @REM This option will try to set the compiler environment for building Nt32Pkg/Nt32Pkg.dsc\r |
174 | @REM If the compiler environment is already installed, then no additional work is required.\r |
175 | @if /I "%1"=="--nt32" (\r |
176 | @set NT32PKG=TRUE\r |
177 | @if not defined BUILD_TOOLS_WITH (\r |
178 | @set BUILD_TOOLS_WITH=Latest\r |
179 | )\r |
180 | @REM This option will try to set the environment for building the Nt32Pkg/Nt32Pkg; on a 64-bit \r |
181 | @REM Windows OS\r |
182 | @if /I "%2"=="X64" (\r |
183 | @set NT32_64=TRUE\r |
184 | @shift\r |
185 | )\r |
186 | @shift\r |
187 | @goto parse_cmd_line\r |
188 | )\r |
189 | \r |
190 | @if not "%1"=="" goto UnknownOptionOrArgument\r |
191 | @goto MainRoutine\r |
192 | \r |
193 | :Usage\r |
194 | @echo Usage: %SCRIPT_NAME% [Options]\r |
195 | @echo Copyright(c) 2014, Intel Corporation. All rights reserved.\r |
196 | @echo.\r |
197 | @echo The system environment variable, WORKSPACE, is always set to the current \r |
198 | @echo working directory.\r |
199 | @echo.\r |
200 | @echo Options:\r |
201 | @echo --help, -h Print this help screen and exit.\r |
202 | @echo.\r |
203 | @echo --version Print this script's version and exit.\r |
204 | @echo.\r |
205 | @echo --reset, -r Reset the EDK_TOOLS_PATH and PATH system environment\r |
206 | @echo variables. The EDK_TOOLS_PATH default is \r |
207 | @echo WORKSPACE\BaseTools, however, it may be overridden by\r |
208 | @echo arguments given to the --edk-tools-path, --pull and/or\r |
209 | @echo --rebuild options.\r |
210 | @echo Once set, the EDK_TOOLS_PATH environment variable reset\r |
211 | @echo by opening up a new command prompt window or through one\r |
212 | @echo of the options provided by this tool\r |
213 | @echo.\r |
214 | @echo --reconfig Overwrite the WORKSPACE/Conf/*.txt files with the\r |
215 | @echo template files from the BaseTools/Conf directory.\r |
216 | @echo.\r |
217 | @echo --edk-tools-path DIRECTORY\r |
218 | @echo This option sets the EDK_TOOLS_PATH to the DIRECTORY\r |
219 | @echo value instead of the default (WORKSPACE\BaseTools).\r |
220 | @echo.\r |
221 | @echo --nt32 [X64] If a compiler tool chain is not available in the\r |
222 | @echo environment, call a script to attempt to set one up.\r |
223 | @echo This flag is only required if building the\r |
224 | @echo Nt32Pkg/Nt32Pkg.dsc system emulator.\r |
225 | @echo If the X64 argument is set, and a compiler tool chain is\r |
226 | @echo not available, attempt to set up a tool chain that will\r |
227 | @echo create X64 binaries. Setting these two options have the\r |
228 | @echo potential side effect of changing tool chains used for a\r |
229 | @echo rebuild.\r |
230 | @echo.\r |
231 | @pause\r |
232 | @echo.\r |
233 | @echo --pull [DIRECTORY] Get the EDK II BaseTools binaries from source control \r |
234 | @echo (must not be used with --rebuild).\r |
235 | @echo If the optional DIRECTORY argument is specified, the tool\r |
236 | @echo sets EDK_TOOLS_PATH to DIRECTORY.\r |
237 | @echo If the DIRECTORY argument is not specified, the tools are\r |
238 | @echo placed in the directory tree pointed to by the current \r |
239 | @echo EDK_TOOLS_PATH environment variable. If the binaries\r |
240 | @echo cannot be obtained from source control, the \r |
241 | @echo EDK_TOOLS_PATH will be set to the default, \r |
242 | @echo WORKSPACE\BaseTools directory.\r |
243 | @echo.\r |
244 | @echo --rebuild [DIRECTORY]\r |
245 | @echo Force Rebuilding the EDK II BaseTools from source\r |
246 | @echo (must not be used with --pull).\r |
247 | @echo NOTE: The build will use whatever compiler tool set\r |
248 | @echo is available in the environment prior to\r |
249 | @echo running edksetup.bat.\r |
250 | @echo If the optional DIRECTORY argument is specified, the tool\r |
251 | @echo sets EDK_TOOLS_PATH to DIRECTORY. Tools binaries will be\r |
252 | @echo placed in the appropriate subdirectory in the \r |
253 | @echo EDK_TOOLS_PATH directory. If the build fails, the\r |
254 | @echo EDK_TOOLS_PATH will be set to the default,\r |
255 | @echo WORKSPACE\BaseTools directory.\r |
256 | @goto ExitSuccess\r |
257 | \r |
258 | :Version\r |
259 | @echo %SCRIPT_NAME% Version: %SCRIPT_VERSION%%SVN_REVISION:~11,-1%\r |
260 | @echo Copyright(c) 2014, Intel Corporation. All rights reserved.\r |
261 | @set HIDE_PATH=TRUE\r |
262 | @call "%WORKSPACE%\BaseTools\Scripts\ShowEnvironment.bat"\r |
263 | @set HIDE_PATH=\r |
264 | @goto ExitSuccess\r |
265 | \r |
266 | :UnknownOptionOrArgument\r |
267 | @echo. ERROR : This argument is not valid: %1\r |
268 | @echo.\r |
269 | @goto ExitFailure\r |
270 | \r |
271 | :NoVisualStudio\r |
272 | @echo ERROR : Unable to determine if a compiler tool chain has been enabled in this\r |
273 | @echo command-prompt window. Rebuilding of the tools with this script is not\r |
274 | @echo possible.\r |
275 | @echo Refer to the BaseTools\BuildNotes.txt for directions for building \r |
276 | @echo the BaseTools binaries.\r |
277 | @echo.\r |
278 | @goto ExitFailure\r |
279 | \r |
280 | :NoPython\r |
281 | @echo ERROR : Unable to rebuild the BaseTools binaries, python does not appear to be\r |
282 | @echo installed. If python is installed, please set the environment\r |
283 | @echo variable, PYTHONHOME to the Path to the python.exe, for example,\r |
284 | @echo if python.exe is located in the C:\Python27 directory, then:\r |
285 | @echo set PYTHONHOME=C:\Python27\r |
286 | @echo.\r |
287 | @goto ExitFailure\r |
288 | \r |
289 | :BadPython\r |
290 | @echo ERROR : Unable to rebuild the BaseTools binaries, python does not appear to be\r |
291 | @echo installed. \r |
292 | @echo The python executable was not found in the PYTHONHOME: %PYTHONHOME%\r |
293 | @echo If python is installed, please set the environment variable, PYTHONHOME \r |
294 | @echo to the Path that contains python.exe, for example, if python.exe is\r |
295 | @echo located in the C:\Python27 directory, then:\r |
296 | @echo set PYTHONHOME=C:\Python27\r |
297 | @echo.\r |
298 | @goto ExitFailure\r |
299 | \r |
300 | :NoCxFreeze\r |
301 | @echo ERROR : Unable to locate cx_Freeze 4.2.3. The cxfreeze.bat file must be located\r |
302 | @echo in the %PYTHONHOME%\Scripts directoryin order to rebuild the BaseTools\r |
303 | @echo binaries.\r |
304 | @echo.\r |
305 | @goto ExitFailure\r |
306 | \r |
307 | :NoBaseTools\r |
308 | @echo ERROR: Unable to locate the BaseTools directory containing the Source tree\r |
309 | @echo.\r |
310 | @goto ExitFailure\r |
311 | \r |
312 | @REM #########################################################################################\r |
313 | @REM MAIN ROUTINE\r |
314 | @REM Set up the Build System environment\r |
315 | @REM #########################################################################################\r |
316 | :MainRoutine\r |
317 | @if defined LOCATION @set "EDK_TOOLS_PATH=%LOCATION%"\r |
318 | @REM SET the EDK_TOOLS_PATH.\r |
319 | @if not exist "%EDK_TOOLS_PATH%" (\r |
320 | @mkdir %EDK_TOOLS_PATH%\r |
321 | )\r |
bd4fa6f5 |
322 | @if not defined NASM_PREFIX (\r |
323 | @echo.\r |
324 | @echo WARNING : NASM_PREFIX environment variable is not set\r |
325 | @if exist "C:\nasm\nasm.exe" @set "NASM_PREFIX=C:\nasm\"\r |
326 | @if exist "C:\nasm\nasm.exe" @echo Found nasm.exe, setting the environment variable to C:\nasm\\r |
327 | @if not exist "C:\nasm\nasm.exe" echo Attempting to build modules that require NASM will fail.\r |
328 | )\r |
bd63012c |
329 | @REM Set up the path to include the EDK_TOOLS_PATH\Bin\Win32 directory; this test determines\r |
330 | @REM whether the path is in the workspace or a fully qualified path that may be outside of\r |
331 | @REM the workspace\r |
332 | @if exist "%WORKSPACE%\%EDK_TOOLS_PATH%" @set "EDK_TOOLS_PATH=%WORKSPACE%\%EDK_TOOLS_PATH%"\r |
333 | \r |
334 | @if defined REBUILD_TOOLS goto SetConf\r |
335 | @if defined SVN_PULL goto SetConf\r |
336 | @if not exist "%EDK_TOOLS_PATH%\Bin\Win32\build.exe" (\r |
337 | @echo ERROR : %EDK_TOOLS_PATH%\Bin\Win32\build.exe does not exist\r |
338 | @echo Re-run this script using --reset, --pull or --rebuild\r |
339 | @echo.\r |
340 | @goto ExitFailure\r |
341 | )\r |
342 | @echo.\r |
343 | @echo Rebuilding of the tools is not required. Binaries of the latest,\r |
344 | @echo tested versions of the tools have been tested and included in the\r |
345 | @echo EDK II repository.\r |
346 | @echo.\r |
347 | @echo If you really want to build the tools, use the --rebuild option.\r |
348 | @echo.\r |
349 | @if not defined CYGWIN_HOME @echo "!!! WARNING !!! No CYGWIN_HOME set, gcc build may not be used !!!"\r |
350 | @if not defined CYGWIN_HOME @echo.\r |
351 | @REM Make sure the WORKSPACE\Conf directory contains the required text files that will be\r |
352 | @REM copied or replaced from the WORKSPACE\BaseTools\Conf directories' template files.\r |
353 | :SetConf\r |
354 | @if not exist "%EDK_TOOLS_PATH%\Conf" (\r |
355 | @if exist "%WORKSPACE%\BaseTools\Conf" (\r |
356 | @set "SRC_CONF=%WORKSPACE%\BaseTools\Conf"\r |
357 | )\r |
358 | ) else (\r |
359 | @set "SRC_CONF=%EDK_TOOLS_PATH%\Conf"\r |
360 | )\r |
361 | @if not defined SRC_CONF (\r |
362 | @echo ERROR : Unable to locate the BaseTools directory tree\r |
363 | @goto ExitFailure\r |
364 | )\r |
365 | \r |
366 | @REM The script will test to see if the files exist, and also use the RESET_ENVIRONMENT flag\r |
367 | @REM to overwrite the WORKSPACE\Conf *.txt files.\r |
368 | @call "%WORKSPACE%\BaseTools\Scripts\ShowEnvironment.bat"\r |
369 | @if errorlevel 1 (\r |
370 | @echo Unable to copy the template files from "%SRC_CONF%" to "%WORKSPACE%\Conf"\r |
371 | @goto ExitFailure\r |
372 | )\r |
373 | @set SRC_CONF=\r |
374 | \r |
375 | @REM Set up Visual Studio if required to build the Nt32Pkg/Nt32Pkg.dsc emulator\r |
376 | @if "%NT32PKG%"=="TRUE" (\r |
cd92f938 |
377 | @if not defined VSINSTALLDIR @set "PATH=%ORIGINAL_PATH%"\r |
bd63012c |
378 | @if not defined NT32_X64 @call "%WORKSPACE%\BaseTools\get_vsvars.bat"\r |
bd4fa6f5 |
379 | @if defined NT32_X64 call "%WORKSPACE%\BaseTools\Scripts\SetVisualStudio.bat"\r |
bd63012c |
380 | @set NT32_X64=\r |
381 | )\r |
382 | @if "%NT32PKG%"=="TRUE" (\r |
cd92f938 |
383 | @if not defined VS_PATH set "VS_PATH=%PATH%"\r |
bd63012c |
384 | )\r |
385 | @if defined VS_PATH @set "PATH=%VS_PATH%"\r |
386 | @if not defined VS_PATH @set "PATH=%ORIGINAL_PATH%"\r |
cd92f938 |
387 | @set "PATH=%EDK_TOOLS_PATH%\Bin\Win32;%PATH%"\r |
bd63012c |
388 | \r |
389 | @if "%REBUILD_TOOLS%"=="TRUE" @goto Rebuild\r |
390 | @if "%SVN_PULL%"== "TRUE" (\r |
391 | if defined PYTHONHOME (\r |
392 | @REM Use the python script if possible to test is the svn command is available, if it fails, the user may be\r |
393 | @REM able to rebuild the Win32 binaries\r |
394 | @call "%WORKSPACE%\BaseTools\Scripts\UpdateBuildVersions.py" --svn-test -v\r |
395 | @if errorlevel 1 (\r |
396 | @echo ERROR : The command-line svn tool is not available and the Win32 binaries do not exist\r |
397 | @echo Please re-run this script again with the --rebuild option to attempt to build \r |
398 | @echo the binaries\r |
399 | @echo.\r |
400 | @goto ExitFailure\r |
401 | )\r |
402 | @if exist %EDK_TOOLS_PATH%\Bin\Win32 @rmdir /S /Q %EDK_TOOLS_PATH%\Bin\Win32\r |
403 | @call svn co https://svn.code.sf.net/p/edk2-toolbinaries/code/trunk/Win32 "%EDK_TOOLS_PATH%\Bin\Win32"\r |
404 | ) else (\r |
405 | @call svn co https://svn.code.sf.net/p/edk2-toolbinaries/code/trunk/Win32 "%EDK_TOOLS_PATH%\Bin\Win32"\r |
406 | @if errorlevel 1 (\r |
407 | @echo ERROR : The command-line svn tool is not available and the Win32 binaries do not exist\r |
408 | @echo Python does not appear to be available either. This script cannot be used to\r |
409 | @echo build the Win32 binaries or to obtain them from this repository:\r |
410 | @echo https://svn.code.sf.net/p/edk2-toolbinaries/code/trunk/Win32\r |
411 | @goto ExitFailure\r |
412 | )\r |
413 | )\r |
414 | @goto ShowAndExit\r |
415 | )\r |
416 | \r |
417 | @if not "%REBUILD_TOOLS%"=="TRUE" @goto ShowAndExit\r |
418 | \r |
419 | @REM The following code is used to rebuild the Win32 BaseTools binaries - check that required tools are available\r |
420 | :Rebuild\r |
421 | @if not defined BASE_TOOLS_PATH @set "BASE_TOOLS_PATH=%WORKSPACE%\BaseTools"\r |
422 | @if not exist "%BASE_TOOLS_PATH%\Source" @goto NoBaseTools\r |
423 | @endlocal\r |
424 | @if not defined VCINSTALLDIR @goto NoVisualStudio\r |
425 | @if not defined PYTHONHOME @goto NoPython\r |
426 | @if not exist "%PYTHONHOME%\python.exe" @goto BadPython\r |
427 | @REM python.exe has been located, now make sure it's in the PATH\r |
428 | @call python --version > nul 2>&1\r |
429 | @if errorlevel 1 @set "PATH=%PYTHONHOME%\python.exe;%PATH%"\r |
430 | @if not defined PYTHON_FREEZER_PATH (\r |
bd4fa6f5 |
431 | @if not exist "%PYTHONHOME%\Scripts\cxfreeze.bat" @goto NoCxFreeze\r |
432 | @set "PYTHON_FREEZER_PATH=%PYTHONHOME%\Scripts"\r |
bd63012c |
433 | )\r |
434 | @call "%WORKSPACE%\BaseTools\Scripts\SetVisualStudio.bat"\r |
435 | @if errorlevel 1 @goto ExitFailure\r |
436 | \r |
437 | :ShowAndExit\r |
438 | @call "%WORKSPACE%\BaseTools\Scripts\ShowEnvironment.bat"\r |
439 | \r |
440 | @REM #########################################################################################\r |
441 | @REM EXIT ROUTINES\r |
442 | @REM #########################################################################################\r |
443 | :ExitSuccess\r |
444 | @set SCRIPT_NAME=\r |
445 | @set SCRIPT_VERSION=\r |
446 | @set SVN_REVISION=\r |
447 | @set RESET_ENVIRONMENT=\r |
448 | @set RECONFIG=\r |
449 | @set NT32PKG=\r |
450 | @set NT32_64=\r |
451 | @set BUILD_TOOLS_WITH=\r |
452 | @set LOCATION=\r |
453 | @set REBUILD_TOOLS=\r |
454 | @set SVN_PULL=\r |
455 | @set SRC_CONF=\r |
456 | @set ARGUMENT=\r |
457 | @set SCRIPT=\r |
458 | @set LIST_VS_VERSIONS=\r |
459 | @set PYTHON_FREEZER_PATH=\r |
460 | @echo on\r |
461 | @exit /B 0\r |
462 | \r |
463 | :ExitFailure\r |
464 | @set SCRIPT_NAME=\r |
465 | @set SCRIPT_VERSION=\r |
466 | @set SVN_REVISION=\r |
467 | @set RESET_ENVIRONMENT=\r |
468 | @set RECONFIG=\r |
469 | @set NT32PKG=\r |
470 | @set NT32_64=\r |
471 | @set BUILD_TOOLS_WITH=\r |
472 | @set LOCATION=\r |
473 | @set REBUILD_TOOLS=\r |
474 | @set SVN_PULL=\r |
475 | @set SRC_CONF=\r |
476 | @set ARGUMENT=\r |
477 | @set SCRIPT=\r |
478 | @set LIST_VS_VERSIONS=\r |
479 | @set PYTHON_FREEZER_PATH=\r |
480 | @echo on\r |
481 | @exit /B 1\r |