From: Feng, Bob C Date: Wed, 31 Jan 2018 08:49:14 +0000 (+0800) Subject: BaseTools: Structure Pcd in CommandLine. X-Git-Tag: edk2-stable201903~2502 X-Git-Url: https://git.proxmox.com/?p=mirror_edk2.git;a=commitdiff_plain;h=6f49996cedfb198beb374ea0cb89a06a71ef960c BaseTools: Structure Pcd in CommandLine. Contributed-under: TianoCore Contribution Agreement 1.1 Signed-off-by: Bob Feng Cc: Liming Gao Reviewed-by: Liming Gao --- diff --git a/BaseTools/Source/Python/AutoGen/AutoGen.py b/BaseTools/Source/Python/AutoGen/AutoGen.py index 1cf50e872f..405bfa145a 100644 --- a/BaseTools/Source/Python/AutoGen/AutoGen.py +++ b/BaseTools/Source/Python/AutoGen/AutoGen.py @@ -398,89 +398,10 @@ class WorkspaceAutoGen(AutoGen): for Arch in self.ArchList: Platform = self.BuildDatabase[self.MetaFile, Arch, Target, Toolchain] - DecPcds = {} - DecPcdsKey = set() - PGen = PlatformAutoGen(self, self.MetaFile, Target, Toolchain, Arch) - if GlobalData.BuildOptionPcd: - for i, pcd in enumerate(GlobalData.BuildOptionPcd): - if type(pcd) is tuple: - continue - (pcdname, pcdvalue) = pcd.split('=') - if not pcdvalue: - EdkLogger.error('build', AUTOGEN_ERROR, "No Value specified for the PCD %s." % (pcdname)) - if '.' in pcdname: - (TokenSpaceGuidCName, TokenCName) = pcdname.split('.') - HasTokenSpace = True - else: - TokenCName = pcdname - TokenSpaceGuidCName = '' - HasTokenSpace = False - TokenSpaceGuidCNameList = [] - FoundFlag = False - PcdDatumType = '' - NewValue = '' - for package in PGen.PackageList: - Guids = package.Guids - self._GuidDict.update(Guids) - for package in PGen.PackageList: - for key in package.Pcds: - PcdItem = package.Pcds[key] - if HasTokenSpace: - if (PcdItem.TokenCName, PcdItem.TokenSpaceGuidCName) == (TokenCName, TokenSpaceGuidCName): - PcdDatumType = PcdItem.DatumType - if pcdvalue.startswith('H'): - try: - pcdvalue = ValueExpressionEx(pcdvalue[1:], PcdDatumType, self._GuidDict)(True) - except BadExpression, Value: - if Value.result > 1: - EdkLogger.error('Parser', FORMAT_INVALID, 'PCD [%s.%s] Value "%s", %s' % - (TokenSpaceGuidCName, TokenCName, pcdvalue, Value)) - pcdvalue = 'H' + pcdvalue - NewValue = BuildOptionPcdValueFormat(TokenSpaceGuidCName, TokenCName, PcdDatumType, pcdvalue) - FoundFlag = True - else: - if PcdItem.TokenCName == TokenCName: - if not PcdItem.TokenSpaceGuidCName in TokenSpaceGuidCNameList: - if len (TokenSpaceGuidCNameList) < 1: - TokenSpaceGuidCNameList.append(PcdItem.TokenSpaceGuidCName) - PcdDatumType = PcdItem.DatumType - TokenSpaceGuidCName = PcdItem.TokenSpaceGuidCName - if pcdvalue.startswith('H'): - try: - pcdvalue = ValueExpressionEx(pcdvalue[1:], PcdDatumType, self._GuidDict)(True) - except BadExpression, Value: - EdkLogger.error('Parser', FORMAT_INVALID, 'PCD [%s.%s] Value "%s", %s' % - (TokenSpaceGuidCName, TokenCName, pcdvalue, Value)) - pcdvalue = 'H' + pcdvalue - NewValue = BuildOptionPcdValueFormat(TokenSpaceGuidCName, TokenCName, PcdDatumType, pcdvalue) - FoundFlag = True - else: - EdkLogger.error( - 'build', - AUTOGEN_ERROR, - "The Pcd %s is found under multiple different TokenSpaceGuid: %s and %s." % (TokenCName, PcdItem.TokenSpaceGuidCName, TokenSpaceGuidCNameList[0]) - ) - GlobalData.BuildOptionPcd[i] = (TokenSpaceGuidCName, TokenCName, NewValue) - if not FoundFlag: - if HasTokenSpace: - EdkLogger.error('build', AUTOGEN_ERROR, "The Pcd %s.%s is not found in the DEC file." % (TokenSpaceGuidCName, TokenCName)) - else: - EdkLogger.error('build', AUTOGEN_ERROR, "The Pcd %s is not found in the DEC file." % (TokenCName)) - for BuildData in PGen.BuildDatabase._CACHE_.values(): - if BuildData.Arch != Arch: - continue - if BuildData.MetaFile.Ext == '.dec': - continue - for key in BuildData.Pcds: - PcdItem = BuildData.Pcds[key] - if (TokenSpaceGuidCName, TokenCName) == (PcdItem.TokenSpaceGuidCName, PcdItem.TokenCName): - PcdItem.DefaultValue = NewValue - if (TokenCName, TokenSpaceGuidCName) in PcdSet: - PcdSet[(TokenCName, TokenSpaceGuidCName)] = NewValue SourcePcdDict = {'DynamicEx':[], 'PatchableInModule':[],'Dynamic':[],'FixedAtBuild':[]} BinaryPcdDict = {'DynamicEx':[], 'PatchableInModule':[]} @@ -488,6 +409,7 @@ class WorkspaceAutoGen(AutoGen): BinaryPcdDict_Keys = BinaryPcdDict.keys() # generate the SourcePcdDict and BinaryPcdDict + PGen = PlatformAutoGen(self, self.MetaFile, Target, Toolchain, Arch) for BuildData in PGen.BuildDatabase._CACHE_.values(): if BuildData.Arch != Arch: continue @@ -630,6 +552,8 @@ class WorkspaceAutoGen(AutoGen): ModuleData = self.BuildDatabase[ModuleFile, Arch, Target, Toolchain] PkgSet.update(ModuleData.Packages) Pkgs = list(PkgSet) + list(PGen.PackageList) + DecPcds = {} + DecPcdsKey = set() for Pkg in Pkgs: for Pcd in Pkg.Pcds: DecPcds[Pcd[0], Pcd[1]] = Pkg.Pcds[Pcd] @@ -1446,15 +1370,25 @@ class PlatformAutoGen(AutoGen): def CollectPlatformDynamicPcds(self): # Override the platform Pcd's value by build option if GlobalData.BuildOptionPcd: - for key in self.Platform.Pcds: - PlatformPcd = self.Platform.Pcds[key] - for PcdItem in GlobalData.BuildOptionPcd: - if (PlatformPcd.TokenSpaceGuidCName, PlatformPcd.TokenCName) == (PcdItem[0], PcdItem[1]): - PlatformPcd.DefaultValue = PcdItem[2] - if PlatformPcd.SkuInfoList: - Sku = PlatformPcd.SkuInfoList[PlatformPcd.SkuInfoList.keys()[0]] - Sku.DefaultValue = PcdItem[2] - break + for PcdItem in GlobalData.BuildOptionPcd: + PlatformPcd = self.Platform.Pcds.get((PcdItem[1],PcdItem[0])) + if PlatformPcd: + if PlatformPcd.DatumType in [TAB_UINT8, TAB_UINT16, TAB_UINT32, TAB_UINT64,'BOOLEAN']: + for sku in PlatformPcd.SkuInfoList: + PlatformPcd.SkuInfoList[sku].DefaultValue = PcdItem[2] + else: + PcdDefaultValue = StringToArray(PcdItem[2]) + for sku in PlatformPcd.SkuInfoList: + skuinfo = PlatformPcd.SkuInfoList[sku] + if skuinfo.VariableGuid: + skuinfo.HiiDefaultValue = PcdDefaultValue + else: + skuinfo.DefaultValue = PcdDefaultValue + PlatformPcd.DefaultValue = PcdDefaultValue + if PlatformPcd.MaxDatumSize: + PlatformPcd.MaxDatumSize = str(max([int(PlatformPcd.MaxDatumSize),len(PcdDefaultValue.split(","))])) + else: + PlatformPcd.MaxDatumSize = str(len(PcdDefaultValue.split(","))) for key in self.Platform.Pcds: for SinglePcd in GlobalData.MixedPcd: diff --git a/BaseTools/Source/Python/Common/Expression.py b/BaseTools/Source/Python/Common/Expression.py index 486c537029..b8c48460ff 100644 --- a/BaseTools/Source/Python/Common/Expression.py +++ b/BaseTools/Source/Python/Common/Expression.py @@ -791,7 +791,7 @@ class ValueExpressionEx(ValueExpression): raise BadExpression('Type %s PCD Value Size is Larger than 4 byte' % self.PcdType) if self.PcdType == 'UINT64' and Size > 8: raise BadExpression('Type %s PCD Value Size is Larger than 8 byte' % self.PcdType) - if self.PcdType in ['VOID*']: + else: try: TmpValue = long(PcdValue) TmpList = [] diff --git a/BaseTools/Source/Python/Common/Misc.py b/BaseTools/Source/Python/Common/Misc.py index ef52154f47..b34cb4c3be 100644 --- a/BaseTools/Source/Python/Common/Misc.py +++ b/BaseTools/Source/Python/Common/Misc.py @@ -2348,7 +2348,7 @@ def PackRegistryFormatGuid(Guid): ) def BuildOptionPcdValueFormat(TokenSpaceGuidCName, TokenCName, PcdDatumType, Value): - if PcdDatumType == 'VOID*': + if PcdDatumType not in [TAB_UINT8, TAB_UINT16, TAB_UINT32, TAB_UINT64,'BOOLEAN']: if Value.startswith('L'): if not Value[1]: EdkLogger.error("build", FORMAT_INVALID, 'For Void* type PCD, when specify the Value in the command line, please use the following format: "string", L"string", H"{...}"') diff --git a/BaseTools/Source/Python/GenFds/FfsInfStatement.py b/BaseTools/Source/Python/GenFds/FfsInfStatement.py index baee543698..b0b242be8d 100644 --- a/BaseTools/Source/Python/GenFds/FfsInfStatement.py +++ b/BaseTools/Source/Python/GenFds/FfsInfStatement.py @@ -237,6 +237,7 @@ class FfsInfStatement(FfsInfStatementClassObject): InfPcds = Inf.Pcds Platform = GenFdsGlobalVariable.WorkSpace.BuildObject[GenFdsGlobalVariable.ActivePlatform, self.CurrentArch, GenFdsGlobalVariable.TargetName, GenFdsGlobalVariable.ToolChainTag] FdfPcdDict = GenFdsGlobalVariable.FdfParser.Profile.PcdDict + PlatformPcds = Platform.Pcds # Workaround here: both build and GenFds tool convert the workspace path to lower case # But INF file path in FDF and DSC file may have real case characters. diff --git a/BaseTools/Source/Python/GenFds/GenFds.py b/BaseTools/Source/Python/GenFds/GenFds.py index 4a5d6f476a..dcba9f24cb 100644 --- a/BaseTools/Source/Python/GenFds/GenFds.py +++ b/BaseTools/Source/Python/GenFds/GenFds.py @@ -302,9 +302,7 @@ def main(): if ArchList != None: GenFdsGlobalVariable.ArchList = ArchList - if Options.OptionPcd: - GlobalData.BuildOptionPcd = Options.OptionPcd - CheckBuildOptionPcd() + # Dsc Build Data will handle Pcd Settings from CommandLine. """Modify images from build output if the feature of loading driver at fixed address is on.""" if GenFdsGlobalVariable.FixedLoadAddress: diff --git a/BaseTools/Source/Python/Workspace/DscBuildData.py b/BaseTools/Source/Python/Workspace/DscBuildData.py index 84f7b6a237..ad5b267fd1 100644 --- a/BaseTools/Source/Python/Workspace/DscBuildData.py +++ b/BaseTools/Source/Python/Workspace/DscBuildData.py @@ -162,7 +162,6 @@ class DscBuildData(PlatformBuildClassObject): self.OutputPath = os.path.dirname(self.DscFile) self.DefaultStores = None self.SkuIdMgr = SkuClass(self.SkuName, self.SkuIds) - arraystr = self.SkuIdMgr.DumpSkuIdArrary() ## XXX[key] = value def __setitem__(self, key, value): @@ -451,7 +450,6 @@ class DscBuildData(PlatformBuildClassObject): ## Override SKUID_IDENTIFIER def _SetSkuName(self, Value): self._SkuName = Value - self._Pcds = None def _GetFdfFile(self): if self._FlashDefinition == None: @@ -889,10 +887,164 @@ class DscBuildData(PlatformBuildClassObject): skuobj.DefaultStoreDict['STANDARD'] = copy.deepcopy(skuobj.DefaultStoreDict[mindefaultstorename]) return Pcds + def RecoverCommandLinePcd(self): + pcdset = [] + if GlobalData.BuildOptionPcd: + for pcd in GlobalData.BuildOptionPcd: + if pcd[2] == "": + pcdset.append((pcd[0],pcd[1],pcd[3])) + else: + pcdobj = self._Pcds.get((pcd[1],pcd[0])) + if pcdobj: + pcdset.append((pcd[0],pcd[1], pcdobj.DefaultValue)) + else: + pcdset.append((pcd[0],pcd[1],pcd[3])) + GlobalData.BuildOptionPcd = pcdset + def GetFieldValueFromComm(self,ValueStr,TokenSpaceGuidCName, TokenCName, FieldName): + PredictedFieldType = "VOID*" + if ValueStr.startswith('L'): + if not ValueStr[1]: + EdkLogger.error("build", FORMAT_INVALID, 'For Void* type PCD, when specify the Value in the command line, please use the following format: "string", L"string", H"{...}"') + ValueStr = ValueStr[0] + '"' + ValueStr[1:] + '"' + PredictedFieldType = "VOID*" + elif ValueStr.startswith('H') or ValueStr.startswith('{'): + EdkLogger.error("build", FORMAT_INVALID, 'Currently we do not support assign H"{...}" format for Pcd field.', ExtraData="%s.%s.%s from command line" % (TokenSpaceGuidCName, TokenCName, FieldName)) + ValueStr = ValueStr[1:] + PredictedFieldType = "VOID*" + elif ValueStr.upper() in ['TRUE', '0X1', '0X01', '1', 'FALSE', '0X0', '0X00', '0']: + PredictedFieldType = "BOOLEAN" + elif ValueStr.isdigit() or ValueStr.upper().startswith('0X'): + PredictedFieldType = TAB_UINT16 + else: + if not ValueStr[0]: + EdkLogger.error("build", FORMAT_INVALID, 'For Void* type PCD, when specify the Value in the command line, please use the following format: "string", L"string", H"{...}"') + ValueStr = '"' + ValueStr + '"' + PredictedFieldType = "VOID*" + IsValid, Cause = CheckPcdDatum(PredictedFieldType, ValueStr) + if not IsValid: + EdkLogger.error("build", FORMAT_INVALID, Cause, ExtraData="%s.%s.%s from command line" % (TokenSpaceGuidCName, TokenCName, FieldName)) + if PredictedFieldType == 'BOOLEAN': + ValueStr = ValueStr.upper() + if ValueStr == 'TRUE' or ValueStr == '1': + ValueStr = '1' + elif ValueStr == 'FALSE' or ValueStr == '0': + ValueStr = '0' + return ValueStr + def __ParsePcdFromCommandLine(self): + if GlobalData.BuildOptionPcd: + for i, pcd in enumerate(GlobalData.BuildOptionPcd): + if type(pcd) is tuple: + continue + (pcdname, pcdvalue) = pcd.split('=') + if not pcdvalue: + EdkLogger.error('build', AUTOGEN_ERROR, "No Value specified for the PCD %s." % (pcdname)) + if '.' in pcdname: + (Name1, Name2) = pcdname.split('.',1) + if "." in Name2: + (Name3, FieldName) = Name2.split(".",1) + if ((Name3,Name1)) in self.DecPcds: + HasTokenSpace = True + TokenCName = Name3 + TokenSpaceGuidCName = Name1 + else: + FieldName = Name2 + TokenCName = Name1 + TokenSpaceGuidCName = '' + HasTokenSpace = False + else: + if ((Name2,Name1)) in self.DecPcds: + HasTokenSpace = True + TokenCName = Name2 + TokenSpaceGuidCName = Name1 + FieldName ="" + else: + FieldName = Name2 + TokenCName = Name1 + TokenSpaceGuidCName = '' + HasTokenSpace = False + else: + FieldName = "" + TokenCName = pcdname + TokenSpaceGuidCName = '' + HasTokenSpace = False + TokenSpaceGuidCNameList = [] + FoundFlag = False + PcdDatumType = '' + NewValue = '' + if not HasTokenSpace: + for key in self.DecPcds: + if TokenCName == key[0]: + if TokenSpaceGuidCName: + EdkLogger.error( + 'build', + AUTOGEN_ERROR, + "The Pcd %s is found under multiple different TokenSpaceGuid: %s and %s." % (TokenCName, TokenSpaceGuidCName, key[1]) + ) + else: + TokenSpaceGuidCName = key[1] + FoundFlag = True + else: + if (TokenCName, TokenSpaceGuidCName) in self.DecPcds: + FoundFlag = True + if FieldName: + NewValue = self.GetFieldValueFromComm(pcdvalue, TokenSpaceGuidCName, TokenCName, FieldName) + GlobalData.BuildOptionPcd[i] = (TokenSpaceGuidCName, TokenCName, FieldName,NewValue,("build command options",1)) + else: + for key in self.DecPcds: + PcdItem = self.DecPcds[key] + if HasTokenSpace: + if (PcdItem.TokenCName, PcdItem.TokenSpaceGuidCName) == (TokenCName, TokenSpaceGuidCName): + PcdDatumType = PcdItem.DatumType + if pcdvalue.startswith('H'): + try: + pcdvalue = ValueExpressionEx(pcdvalue[1:], PcdDatumType, self._GuidDict)(True) + except BadExpression, Value: + if Value.result > 1: + EdkLogger.error('Parser', FORMAT_INVALID, 'PCD [%s.%s] Value "%s", %s' % + (TokenSpaceGuidCName, TokenCName, pcdvalue, Value)) + pcdvalue = 'H' + pcdvalue + NewValue = BuildOptionPcdValueFormat(TokenSpaceGuidCName, TokenCName, PcdDatumType, pcdvalue) + FoundFlag = True + else: + if PcdItem.TokenCName == TokenCName: + if not PcdItem.TokenSpaceGuidCName in TokenSpaceGuidCNameList: + if len (TokenSpaceGuidCNameList) < 1: + TokenSpaceGuidCNameList.append(PcdItem.TokenSpaceGuidCName) + PcdDatumType = PcdItem.DatumType + TokenSpaceGuidCName = PcdItem.TokenSpaceGuidCName + if pcdvalue.startswith('H'): + try: + pcdvalue = ValueExpressionEx(pcdvalue[1:], PcdDatumType, self._GuidDict)(True) + except BadExpression, Value: + EdkLogger.error('Parser', FORMAT_INVALID, 'PCD [%s.%s] Value "%s", %s' % + (TokenSpaceGuidCName, TokenCName, pcdvalue, Value)) + pcdvalue = 'H' + pcdvalue + NewValue = BuildOptionPcdValueFormat(TokenSpaceGuidCName, TokenCName, PcdDatumType, pcdvalue) + FoundFlag = True + else: + EdkLogger.error( + 'build', + AUTOGEN_ERROR, + "The Pcd %s is found under multiple different TokenSpaceGuid: %s and %s." % (TokenCName, PcdItem.TokenSpaceGuidCName, TokenSpaceGuidCNameList[0]) + ) + GlobalData.BuildOptionPcd[i] = (TokenSpaceGuidCName, TokenCName, FieldName,NewValue,("build command options",1)) + if not FoundFlag: + if HasTokenSpace: + EdkLogger.error('build', AUTOGEN_ERROR, "The Pcd %s.%s is not found in the DEC file." % (TokenSpaceGuidCName, TokenCName)) + else: + EdkLogger.error('build', AUTOGEN_ERROR, "The Pcd %s is not found in the DEC file." % (TokenCName)) + for BuildData in self._Bdb._CACHE_.values(): + if BuildData.MetaFile.Ext == '.dec' or BuildData.MetaFile.Ext == '.dsc': + continue + for key in BuildData.Pcds: + PcdItem = BuildData.Pcds[key] + if (TokenSpaceGuidCName, TokenCName) == (PcdItem.TokenSpaceGuidCName, PcdItem.TokenCName) and FieldName =="": + PcdItem.DefaultValue = NewValue ## Retrieve all PCD settings in platform def _GetPcds(self): if self._Pcds == None: self._Pcds = sdict() + self.__ParsePcdFromCommandLine() self._Pcds.update(self._GetPcd(MODEL_PCD_FIXED_AT_BUILD)) self._Pcds.update(self._GetPcd(MODEL_PCD_PATCHABLE_IN_MODULE)) self._Pcds.update(self._GetPcd(MODEL_PCD_FEATURE_FLAG)) @@ -907,6 +1059,8 @@ class DscBuildData(PlatformBuildClassObject): self._Pcds = self.UpdateStructuredPcds(MODEL_PCD_TYPE_LIST, self._Pcds) self._Pcds = self.CompleteHiiPcdsDefaultStores(self._Pcds) self._Pcds = self._FilterPcdBySkuUsage(self._Pcds) + self._Pcds = self.OverrideByFdfCommOverAll(self._Pcds) + self.RecoverCommandLinePcd() return self._Pcds def _dumpPcdInfo(self,Pcds): @@ -971,7 +1125,55 @@ class DscBuildData(PlatformBuildClassObject): structure_pcd_data[(item[0],item[1])].append(item) return structure_pcd_data + def OverrideByFdfComm(self,StruPcds): + StructurePcdInCom = {(item[0],item[1],item[2] ):(item[3],item[4]) for item in GlobalData.BuildOptionPcd if len(item) == 5 and (item[1],item[0]) in StruPcds } if GlobalData.BuildOptionPcd else {} + GlobalPcds = set([(item[0],item[1]) for item in StructurePcdInCom.keys()]) + for Pcd in StruPcds.values(): + if (Pcd.TokenSpaceGuidCName,Pcd.TokenCName) not in GlobalPcds: + continue + FieldValues = {item[2]:StructurePcdInCom[item] for item in StructurePcdInCom if (Pcd.TokenSpaceGuidCName,Pcd.TokenCName) == (item[0],item[1]) and item[2]} + for sku in Pcd.SkuOverrideValues: + for defaultstore in Pcd.SkuOverrideValues[sku]: + for field in FieldValues: + if field not in Pcd.SkuOverrideValues[sku][defaultstore]: + Pcd.SkuOverrideValues[sku][defaultstore][field] = ["","",""] + Pcd.SkuOverrideValues[sku][defaultstore][field][0] = FieldValues[field][0] + Pcd.SkuOverrideValues[sku][defaultstore][field][1] = FieldValues[field][1][0] + Pcd.SkuOverrideValues[sku][defaultstore][field][2] = FieldValues[field][1][1] + return StruPcds + def OverrideByFdfCommOverAll(self,AllPcds): + def CheckStructureInComm(commpcds): + if not commpcds: + return False + if len(commpcds[0]) == 5: + return True + return False + if CheckStructureInComm(GlobalData.BuildOptionPcd): + StructurePcdInCom = {(item[0],item[1],item[2] ):(item[3],item[4]) for item in GlobalData.BuildOptionPcd } if GlobalData.BuildOptionPcd else {} + NoFiledValues = {(item[0],item[1]):StructurePcdInCom[item] for item in StructurePcdInCom if not item[2]} + else: + NoFiledValues = {(item[0],item[1]):[item[2]] for item in GlobalData.BuildOptionPcd} + for Guid,Name in NoFiledValues: + if (Name,Guid) in AllPcds: + Pcd = AllPcds.get((Name,Guid)) + Pcd.DefaultValue = NoFiledValues[(Pcd.TokenSpaceGuidCName,Pcd.TokenCName)][0] + for sku in Pcd.SkuInfoList: + SkuInfo = Pcd.SkuInfoList[sku] + if SkuInfo.DefaultValue: + SkuInfo.DefaultValue = NoFiledValues[(Pcd.TokenSpaceGuidCName,Pcd.TokenCName)][0] + else: + SkuInfo.HiiDefaultValue = NoFiledValues[(Pcd.TokenSpaceGuidCName,Pcd.TokenCName)][0] + for defaultstore in SkuInfo.DefaultStoreDict: + SkuInfo.DefaultStoreDict[defaultstore] = NoFiledValues[(Pcd.TokenSpaceGuidCName,Pcd.TokenCName)][0] + else: + PcdInDec = self.DecPcds.get((Name,Guid)) + if PcdInDec: + if PcdInDec.Type in [self._PCD_TYPE_STRING_[MODEL_PCD_FIXED_AT_BUILD], + self._PCD_TYPE_STRING_[MODEL_PCD_PATCHABLE_IN_MODULE]]: + self.Pcds[Name, Guid] = copy.deepcopy(PcdInDec) + self.Pcds[Name, Guid].DefaultValue = NoFiledValues[( Guid,Name)][0] + return AllPcds def UpdateStructuredPcds(self, TypeList, AllPcds): DynamicPcdType = [self._PCD_TYPE_STRING_[MODEL_PCD_DYNAMIC_DEFAULT], @@ -1002,7 +1204,7 @@ class DscBuildData(PlatformBuildClassObject): continue if SkuName in SkuIds and "." in TokenSpaceGuid: - S_PcdSet.append(( TokenSpaceGuid.split(".")[0],TokenSpaceGuid.split(".")[1], PcdCName,SkuName, default_store,Dummy5, AnalyzePcdExpression(Setting)[0])) + S_PcdSet.append([ TokenSpaceGuid.split(".")[0],TokenSpaceGuid.split(".")[1], PcdCName,SkuName, default_store,Dummy5, AnalyzePcdExpression(Setting)[0]]) # handle pcd value override StrPcdSet = self.GetStructurePcdInfo(S_PcdSet) @@ -1072,7 +1274,7 @@ class DscBuildData(PlatformBuildClassObject): for defaultstoreid in DefaultStores: if defaultstoreid not in stru_pcd.SkuOverrideValues[skuid]: stru_pcd.SkuOverrideValues[skuid][defaultstoreid] = copy.deepcopy(stru_pcd.SkuOverrideValues[nextskuid][mindefaultstorename]) - + S_pcd_set = self.OverrideByFdfComm(S_pcd_set) Str_Pcd_Values = self.GenerateByteArrayValue(S_pcd_set) if Str_Pcd_Values: for (skuname,StoreName,PcdGuid,PcdName,PcdValue) in Str_Pcd_Values: diff --git a/BaseTools/Source/Python/build/build.py b/BaseTools/Source/Python/build/build.py index e4adee2beb..24f9962c9d 100644 --- a/BaseTools/Source/Python/build/build.py +++ b/BaseTools/Source/Python/build/build.py @@ -772,7 +772,7 @@ class Build(): self.AutoGenTime = 0 self.MakeTime = 0 self.GenFdsTime = 0 - GlobalData.BuildOptionPcd = BuildOptions.OptionPcd + GlobalData.BuildOptionPcd = BuildOptions.OptionPcd if BuildOptions.OptionPcd else {} #Set global flag for build mode GlobalData.gIgnoreSource = BuildOptions.IgnoreSources GlobalData.gUseHashCache = BuildOptions.UseHashCache