]> git.proxmox.com Git - pve-docs.git/blame - pveceph.adoc
backup: clarify that CLI means FS-level and highlight retention-note
[pve-docs.git] / pveceph.adoc
CommitLineData
80c0adcb 1[[chapter_pveceph]]
0840a663 2ifdef::manvolnum[]
b2f242ab
DM
3pveceph(1)
4==========
404a158e 5:pve-toplevel:
0840a663
DM
6
7NAME
8----
9
21394e70 10pveceph - Manage Ceph Services on Proxmox VE Nodes
0840a663 11
49a5e11c 12SYNOPSIS
0840a663
DM
13--------
14
15include::pveceph.1-synopsis.adoc[]
16
17DESCRIPTION
18-----------
19endif::manvolnum[]
0840a663 20ifndef::manvolnum[]
4bfe3e35
TL
21Deploy Hyper-Converged Ceph Cluster
22===================================
49d3ad91 23:pve-toplevel:
0840a663
DM
24endif::manvolnum[]
25
94d7a98c 26[thumbnail="screenshot/gui-ceph-status-dashboard.png"]
8997dd6e 27
40e6c806 28{pve} unifies your compute and storage systems, that is, you can use the same
a474ca1f
AA
29physical nodes within a cluster for both computing (processing VMs and
30containers) and replicated storage. The traditional silos of compute and
31storage resources can be wrapped up into a single hyper-converged appliance.
40e6c806 32Separate storage networks (SANs) and connections via network attached storage
a474ca1f
AA
33(NAS) disappear. With the integration of Ceph, an open source software-defined
34storage platform, {pve} has the ability to run and manage Ceph storage directly
35on the hypervisor nodes.
c994e4e5
DM
36
37Ceph is a distributed object store and file system designed to provide
1d54c3b4
AA
38excellent performance, reliability and scalability.
39
04ba9b24 40.Some advantages of Ceph on {pve} are:
40e6c806 41- Easy setup and management via CLI and GUI
a474ca1f 42- Thin provisioning
40e6c806 43- Snapshot support
a474ca1f 44- Self healing
a474ca1f
AA
45- Scalable to the exabyte level
46- Setup pools with different performance and redundancy characteristics
47- Data is replicated, making it fault tolerant
40e6c806 48- Runs on commodity hardware
a474ca1f 49- No need for hardware RAID controllers
a474ca1f
AA
50- Open source
51
40e6c806
DW
52For small to medium-sized deployments, it is possible to install a Ceph server for
53RADOS Block Devices (RBD) directly on your {pve} cluster nodes (see
54xref:ceph_rados_block_devices[Ceph RADOS Block Devices (RBD)]). Recent
55hardware has a lot of CPU power and RAM, so running storage services
c994e4e5 56and VMs on the same node is possible.
21394e70 57
40e6c806
DW
58To simplify management, we provide 'pveceph' - a tool for installing and
59managing {ceph} services on {pve} nodes.
21394e70 60
40e6c806 61.Ceph consists of multiple Daemons, for use as an RBD storage:
1d54c3b4
AA
62- Ceph Monitor (ceph-mon)
63- Ceph Manager (ceph-mgr)
64- Ceph OSD (ceph-osd; Object Storage Daemon)
65
d241b01b 66TIP: We highly recommend to get familiar with Ceph
b46a49ed 67footnote:[Ceph intro {cephdocs-url}/start/intro/],
d241b01b 68its architecture
b46a49ed 69footnote:[Ceph architecture {cephdocs-url}/architecture/]
477fbcfb 70and vocabulary
b46a49ed 71footnote:[Ceph glossary {cephdocs-url}/glossary].
1d54c3b4 72
21394e70
DM
73
74Precondition
75------------
76
40e6c806 77To build a hyper-converged Proxmox + Ceph Cluster, you must use at least
76f6eca4 78three (preferably) identical servers for the setup.
21394e70
DM
79
80Check also the recommendations from
b46a49ed 81{cephdocs-url}/start/hardware-recommendations/[Ceph's website].
21394e70 82
76f6eca4 83.CPU
40e6c806 84A high CPU core frequency reduces latency and should be preferred. As a simple
2f19a6b0
TL
85rule of thumb, you should assign a CPU core (or thread) to each Ceph service to
86provide enough resources for stable and durable Ceph performance.
76f6eca4
AA
87
88.Memory
89Especially in a hyper-converged setup, the memory consumption needs to be
40e6c806
DW
90carefully monitored. In addition to the predicted memory usage of virtual
91machines and containers, you must also account for having enough memory
92available for Ceph to provide excellent and stable performance.
5b502340
AA
93
94As a rule of thumb, for roughly **1 TiB of data, 1 GiB of memory** will be used
3a433e9b 95by an OSD. Especially during recovery, re-balancing or backfilling.
5b502340
AA
96
97The daemon itself will use additional memory. The Bluestore backend of the
98daemon requires by default **3-5 GiB of memory** (adjustable). In contrast, the
99legacy Filestore backend uses the OS page cache and the memory consumption is
100generally related to PGs of an OSD daemon.
76f6eca4
AA
101
102.Network
103We recommend a network bandwidth of at least 10 GbE or more, which is used
104exclusively for Ceph. A meshed network setup
105footnote:[Full Mesh Network for Ceph {webwiki-url}Full_Mesh_Network_for_Ceph_Server]
106is also an option if there are no 10 GbE switches available.
107
2f19a6b0
TL
108The volume of traffic, especially during recovery, will interfere with other
109services on the same network and may even break the {pve} cluster stack.
76f6eca4 110
40e6c806
DW
111Furthermore, you should estimate your bandwidth needs. While one HDD might not
112saturate a 1 Gb link, multiple HDD OSDs per node can, and modern NVMe SSDs will
113even saturate 10 Gbps of bandwidth quickly. Deploying a network capable of even
114more bandwidth will ensure that this isn't your bottleneck and won't be anytime
115soon. 25, 40 or even 100 Gbps are possible.
76f6eca4
AA
116
117.Disks
118When planning the size of your Ceph cluster, it is important to take the
40e6c806 119recovery time into consideration. Especially with small clusters, recovery
76f6eca4
AA
120might take long. It is recommended that you use SSDs instead of HDDs in small
121setups to reduce recovery time, minimizing the likelihood of a subsequent
122failure event during recovery.
123
3a433e9b 124In general, SSDs will provide more IOPS than spinning disks. With this in mind,
40e6c806
DW
125in addition to the higher cost, it may make sense to implement a
126xref:pve_ceph_device_classes[class based] separation of pools. Another way to
127speed up OSDs is to use a faster disk as a journal or
513e2f57
TL
128DB/**W**rite-**A**head-**L**og device, see
129xref:pve_ceph_osds[creating Ceph OSDs].
130If a faster disk is used for multiple OSDs, a proper balance between OSD
40e6c806
DW
131and WAL / DB (or journal) disk must be selected, otherwise the faster disk
132becomes the bottleneck for all linked OSDs.
133
134Aside from the disk type, Ceph performs best with an even sized and distributed
135amount of disks per node. For example, 4 x 500 GB disks within each node is
2f19a6b0
TL
136better than a mixed setup with a single 1 TB and three 250 GB disk.
137
40e6c806
DW
138You also need to balance OSD count and single OSD capacity. More capacity
139allows you to increase storage density, but it also means that a single OSD
140failure forces Ceph to recover more data at once.
76f6eca4 141
a474ca1f 142.Avoid RAID
86be506d 143As Ceph handles data object redundancy and multiple parallel writes to disks
c78756be 144(OSDs) on its own, using a RAID controller normally doesn’t improve
86be506d 145performance or availability. On the contrary, Ceph is designed to handle whole
40e6c806
DW
146disks on it's own, without any abstraction in between. RAID controllers are not
147designed for the Ceph workload and may complicate things and sometimes even
86be506d
TL
148reduce performance, as their write and caching algorithms may interfere with
149the ones from Ceph.
a474ca1f 150
40e6c806 151WARNING: Avoid RAID controllers. Use host bus adapter (HBA) instead.
a474ca1f 152
40e6c806
DW
153NOTE: The above recommendations should be seen as a rough guidance for choosing
154hardware. Therefore, it is still essential to adapt it to your specific needs.
155You should test your setup and monitor health and performance continuously.
76f6eca4 156
2394c306 157[[pve_ceph_install_wizard]]
40e6c806 158Initial Ceph Installation & Configuration
2394c306
TM
159-----------------------------------------
160
513e2f57
TL
161Using the Web-based Wizard
162~~~~~~~~~~~~~~~~~~~~~~~~~~
163
2394c306
TM
164[thumbnail="screenshot/gui-node-ceph-install.png"]
165
166With {pve} you have the benefit of an easy to use installation wizard
167for Ceph. Click on one of your cluster nodes and navigate to the Ceph
40e6c806
DW
168section in the menu tree. If Ceph is not already installed, you will see a
169prompt offering to do so.
2394c306 170
40e6c806 171The wizard is divided into multiple sections, where each needs to
513e2f57
TL
172finish successfully, in order to use Ceph.
173
174First you need to chose which Ceph version you want to install. Prefer the one
175from your other nodes, or the newest if this is the first node you install
176Ceph.
177
178After starting the installation, the wizard will download and install all the
179required packages from {pve}'s Ceph repository.
94d7a98c 180[thumbnail="screenshot/gui-node-ceph-install-wizard-step0.png"]
2394c306 181
513e2f57 182After finishing the installation step, you will need to create a configuration.
6a711e64
TL
183This step is only needed once per cluster, as this configuration is distributed
184automatically to all remaining cluster members through {pve}'s clustered
185xref:chapter_pmxcfs[configuration file system (pmxcfs)].
2394c306
TM
186
187The configuration step includes the following settings:
188
40e6c806
DW
189* *Public Network:* You can set up a dedicated network for Ceph. This
190setting is required. Separating your Ceph traffic is highly recommended.
191Otherwise, it could cause trouble with other latency dependent services,
192for example, cluster communication may decrease Ceph's performance.
2394c306
TM
193
194[thumbnail="screenshot/gui-node-ceph-install-wizard-step2.png"]
195
40e6c806 196* *Cluster Network:* As an optional step, you can go even further and
2394c306
TM
197separate the xref:pve_ceph_osds[OSD] replication & heartbeat traffic
198as well. This will relieve the public network and could lead to
40e6c806 199significant performance improvements, especially in large clusters.
2394c306
TM
200
201You have two more options which are considered advanced and therefore
40e6c806 202should only changed if you know what you are doing.
2394c306 203
40e6c806 204* *Number of replicas*: Defines how often an object is replicated
2394c306 205* *Minimum replicas*: Defines the minimum number of required replicas
40e6c806 206for I/O to be marked as complete.
2394c306 207
40e6c806 208Additionally, you need to choose your first monitor node. This step is required.
2394c306 209
40e6c806
DW
210That's it. You should now see a success page as the last step, with further
211instructions on how to proceed. Your system is now ready to start using Ceph.
212To get started, you will need to create some additional xref:pve_ceph_monitors[monitors],
213xref:pve_ceph_osds[OSDs] and at least one xref:pve_ceph_pools[pool].
2394c306 214
40e6c806
DW
215The rest of this chapter will guide you through getting the most out of
216your {pve} based Ceph setup. This includes the aforementioned tips and
217more, such as xref:pveceph_fs[CephFS], which is a helpful addition to your
2394c306 218new Ceph cluster.
21394e70 219
58f95dd7 220[[pve_ceph_install]]
513e2f57
TL
221CLI Installation of Ceph Packages
222~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
223
224Alternatively to the the recommended {pve} Ceph installation wizard available
225in the web-interface, you can use the following CLI command on each node:
21394e70
DM
226
227[source,bash]
228----
19920184 229pveceph install
21394e70
DM
230----
231
232This sets up an `apt` package repository in
233`/etc/apt/sources.list.d/ceph.list` and installs the required software.
234
235
513e2f57
TL
236Initial Ceph configuration via CLI
237~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
8997dd6e 238
2394c306
TM
239Use the {pve} Ceph installation wizard (recommended) or run the
240following command on one node:
21394e70
DM
241
242[source,bash]
243----
244pveceph init --network 10.10.10.0/24
245----
246
2394c306 247This creates an initial configuration at `/etc/pve/ceph.conf` with a
40e6c806
DW
248dedicated network for Ceph. This file is automatically distributed to
249all {pve} nodes, using xref:chapter_pmxcfs[pmxcfs]. The command also
250creates a symbolic link at `/etc/ceph/ceph.conf`, which points to that file.
251Thus, you can simply run Ceph commands without the need to specify a
2394c306 252configuration file.
21394e70
DM
253
254
d9a27ee1 255[[pve_ceph_monitors]]
b3338e29
AA
256Ceph Monitor
257-----------
513e2f57
TL
258
259[thumbnail="screenshot/gui-ceph-monitor.png"]
260
1d54c3b4 261The Ceph Monitor (MON)
b46a49ed 262footnote:[Ceph Monitor {cephdocs-url}/start/intro/]
40e6c806
DW
263maintains a master copy of the cluster map. For high availability, you need at
264least 3 monitors. One monitor will already be installed if you
265used the installation wizard. You won't need more than 3 monitors, as long
266as your cluster is small to medium-sized. Only really large clusters will
267require more than this.
1d54c3b4 268
c998bdf2 269[[pveceph_create_mon]]
b3338e29
AA
270Create Monitors
271~~~~~~~~~~~~~~~
272
1d54c3b4 273On each node where you want to place a monitor (three monitors are recommended),
40e6c806 274create one by using the 'Ceph -> Monitor' tab in the GUI or run:
21394e70
DM
275
276
277[source,bash]
278----
d1fdb121 279pveceph mon create
21394e70
DM
280----
281
c998bdf2 282[[pveceph_destroy_mon]]
b3338e29
AA
283Destroy Monitors
284~~~~~~~~~~~~~~~~
0e38a564 285
40e6c806 286To remove a Ceph Monitor via the GUI, first select a node in the tree view and
0e38a564
AA
287go to the **Ceph -> Monitor** panel. Select the MON and click the **Destroy**
288button.
289
40e6c806 290To remove a Ceph Monitor via the CLI, first connect to the node on which the MON
0e38a564
AA
291is running. Then execute the following command:
292[source,bash]
293----
294pveceph mon destroy
295----
296
297NOTE: At least three Monitors are needed for quorum.
298
299
1d54c3b4 300[[pve_ceph_manager]]
b3338e29
AA
301Ceph Manager
302------------
40e6c806 303
b3338e29 304The Manager daemon runs alongside the monitors. It provides an interface to
40e6c806 305monitor the cluster. Since the release of Ceph luminous, at least one ceph-mgr
b46a49ed 306footnote:[Ceph Manager {cephdocs-url}/mgr/] daemon is
b3338e29
AA
307required.
308
55d634e6 309[[pveceph_create_mgr]]
b3338e29
AA
310Create Manager
311~~~~~~~~~~~~~~
1d54c3b4 312
40e6c806
DW
313Multiple Managers can be installed, but only one Manager is active at any given
314time.
1d54c3b4 315
1d54c3b4
AA
316[source,bash]
317----
d1fdb121 318pveceph mgr create
1d54c3b4
AA
319----
320
c1f38fe3
AA
321NOTE: It is recommended to install the Ceph Manager on the monitor nodes. For
322high availability install more then one manager.
323
21394e70 324
c998bdf2 325[[pveceph_destroy_mgr]]
b3338e29
AA
326Destroy Manager
327~~~~~~~~~~~~~~~
549350fe 328
40e6c806 329To remove a Ceph Manager via the GUI, first select a node in the tree view and
549350fe
AA
330go to the **Ceph -> Monitor** panel. Select the Manager and click the
331**Destroy** button.
332
40e6c806 333To remove a Ceph Monitor via the CLI, first connect to the node on which the
549350fe
AA
334Manager is running. Then execute the following command:
335[source,bash]
336----
337pveceph mgr destroy
338----
339
40e6c806
DW
340NOTE: While a manager is not a hard-dependency, it is crucial for a Ceph cluster,
341as it handles important features like PG-autoscaling, device health monitoring,
342telemetry and more.
549350fe 343
d9a27ee1 344[[pve_ceph_osds]]
b3338e29
AA
345Ceph OSDs
346---------
513e2f57
TL
347
348[thumbnail="screenshot/gui-ceph-osd-status.png"]
349
40e6c806 350Ceph **O**bject **S**torage **D**aemons store objects for Ceph over the
b3338e29
AA
351network. It is recommended to use one OSD per physical disk.
352
081cb761 353[[pve_ceph_osd_create]]
b3338e29
AA
354Create OSDs
355~~~~~~~~~~~
21394e70 356
40e6c806 357You can create an OSD either via the {pve} web-interface or via the CLI using
e79e0b9d 358`pveceph`. For example:
21394e70
DM
359
360[source,bash]
361----
d1fdb121 362pveceph osd create /dev/sd[X]
21394e70
DM
363----
364
40e6c806 365TIP: We recommend a Ceph cluster with at least three nodes and at least 12
e79e0b9d 366OSDs, evenly distributed among the nodes.
1d54c3b4 367
40e6c806
DW
368If the disk was in use before (for example, for ZFS or as an OSD) you first need
369to zap all traces of that usage. To remove the partition table, boot sector and
370any other OSD leftover, you can use the following command:
a474ca1f
AA
371
372[source,bash]
373----
9bddef40 374ceph-volume lvm zap /dev/sd[X] --destroy
a474ca1f
AA
375----
376
e79e0b9d 377WARNING: The above command will destroy all data on the disk!
1d54c3b4 378
b3338e29 379.Ceph Bluestore
21394e70 380
1d54c3b4 381Starting with the Ceph Kraken release, a new Ceph OSD storage type was
40e6c806 382introduced called Bluestore
2798d126 383footnote:[Ceph Bluestore https://ceph.com/community/new-luminous-bluestore/].
9bddef40 384This is the default when creating OSDs since Ceph Luminous.
21394e70
DM
385
386[source,bash]
387----
d1fdb121 388pveceph osd create /dev/sd[X]
1d54c3b4
AA
389----
390
1e834cb2 391.Block.db and block.wal
1d54c3b4
AA
392
393If you want to use a separate DB/WAL device for your OSDs, you can specify it
b3338e29
AA
394through the '-db_dev' and '-wal_dev' options. The WAL is placed with the DB, if
395not specified separately.
1d54c3b4
AA
396
397[source,bash]
398----
d1fdb121 399pveceph osd create /dev/sd[X] -db_dev /dev/sd[Y] -wal_dev /dev/sd[Z]
1d54c3b4
AA
400----
401
40e6c806
DW
402You can directly choose the size of those with the '-db_size' and '-wal_size'
403parameters respectively. If they are not given, the following values (in order)
9bddef40
DC
404will be used:
405
40e6c806 406* bluestore_block_{db,wal}_size from Ceph configuration...
352c803f
TL
407** ... database, section 'osd'
408** ... database, section 'global'
409** ... file, section 'osd'
410** ... file, section 'global'
9bddef40
DC
411* 10% (DB)/1% (WAL) of OSD size
412
40e6c806 413NOTE: The DB stores BlueStore’s internal metadata, and the WAL is BlueStore’s
ee4a0e96 414internal journal or write-ahead log. It is recommended to use a fast SSD or
1d54c3b4
AA
415NVRAM for better performance.
416
b3338e29 417.Ceph Filestore
9bddef40 418
40e6c806 419Before Ceph Luminous, Filestore was used as the default storage type for Ceph OSDs.
9bddef40 420Starting with Ceph Nautilus, {pve} does not support creating such OSDs with
352c803f
TL
421'pveceph' anymore. If you still want to create filestore OSDs, use
422'ceph-volume' directly.
1d54c3b4
AA
423
424[source,bash]
425----
9bddef40 426ceph-volume lvm create --filestore --data /dev/sd[X] --journal /dev/sd[Y]
21394e70
DM
427----
428
081cb761 429[[pve_ceph_osd_destroy]]
b3338e29
AA
430Destroy OSDs
431~~~~~~~~~~~~
be2d137e 432
40e6c806
DW
433To remove an OSD via the GUI, first select a {PVE} node in the tree view and go
434to the **Ceph -> OSD** panel. Then select the OSD to destroy and click the **OUT**
435button. Once the OSD status has changed from `in` to `out`, click the **STOP**
436button. Finally, after the status has changed from `up` to `down`, select
437**Destroy** from the `More` drop-down menu.
be2d137e
AA
438
439To remove an OSD via the CLI run the following commands.
40e6c806 440
be2d137e
AA
441[source,bash]
442----
443ceph osd out <ID>
444systemctl stop ceph-osd@<ID>.service
445----
40e6c806 446
be2d137e
AA
447NOTE: The first command instructs Ceph not to include the OSD in the data
448distribution. The second command stops the OSD service. Until this time, no
449data is lost.
450
451The following command destroys the OSD. Specify the '-cleanup' option to
452additionally destroy the partition table.
40e6c806 453
be2d137e
AA
454[source,bash]
455----
456pveceph osd destroy <ID>
457----
40e6c806
DW
458
459WARNING: The above command will destroy all data on the disk!
be2d137e
AA
460
461
07fef357 462[[pve_ceph_pools]]
b3338e29
AA
463Ceph Pools
464----------
94d7a98c
TL
465
466[thumbnail="screenshot/gui-ceph-pools.png"]
467
40e6c806
DW
468A pool is a logical group for storing objects. It holds a collection of objects,
469known as **P**lacement **G**roups (`PG`, `pg_num`).
1d54c3b4 470
b3338e29 471
6004d86b 472Create and Edit Pools
5b9f923f 473~~~~~~~~~~~~~~~~~~~~~
b3338e29 474
513e2f57
TL
475You can create and edit pools from the command line or the web-interface of any
476{pve} host under **Ceph -> Pools**.
d56606c7 477
90682f35 478When no options are given, we set a default of **128 PGs**, a **size of 3
d56606c7
TL
479replicas** and a **min_size of 2 replicas**, to ensure no data loss occurs if
480any OSD fails.
1d54c3b4 481
ef3efe51 482WARNING: **Do not set a min_size of 1**. A replicated pool with min_size of 1
40e6c806 483allows I/O on an object when it has only 1 replica, which could lead to data
ef3efe51
AA
484loss, incomplete PGs or unfound objects.
485
513e2f57
TL
486It is advised that you either enable the PG-Autoscaler or calculate the PG
487number based on your setup. You can find the formula and the PG calculator
f8bfcb41 488footnote:[PG calculator https://web.archive.org/web/20210301111112/http://ceph.com/pgcalc/] online. From Ceph Nautilus
513e2f57
TL
489onward, you can change the number of PGs
490footnoteref:[placement_groups,Placement Groups
c446b6bb 491{cephdocs-url}/rados/operations/placement-groups/] after the setup.
1d54c3b4 492
513e2f57 493The PG autoscaler footnoteref:[autoscaler,Automated Scaling
c446b6bb 494{cephdocs-url}/rados/operations/placement-groups/#automated-scaling] can
513e2f57
TL
495automatically scale the PG count for a pool in the background. Setting the
496`Target Size` or `Target Ratio` advanced parameters helps the PG-Autoscaler to
497make better decisions.
1d54c3b4 498
d56606c7 499.Example for creating a pool over the CLI
1d54c3b4
AA
500[source,bash]
501----
d56606c7 502pveceph pool create <name> --add_storages
1d54c3b4
AA
503----
504
40e6c806
DW
505TIP: If you would also like to automatically define a storage for your
506pool, keep the `Add as Storage' checkbox checked in the web-interface, or use the
d56606c7 507command line option '--add_storages' at pool creation.
21394e70 508
513e2f57
TL
509Pool Options
510^^^^^^^^^^^^
511
94d7a98c
TL
512[thumbnail="screenshot/gui-ceph-pool-create.png"]
513
513e2f57
TL
514The following options are available on pool creation, and partially also when
515editing a pool.
516
c446b6bb
DW
517Name:: The name of the pool. This must be unique and can't be changed afterwards.
518Size:: The number of replicas per object. Ceph always tries to have this many
519copies of an object. Default: `3`.
520PG Autoscale Mode:: The automatic PG scaling mode footnoteref:[autoscaler] of
521the pool. If set to `warn`, it produces a warning message when a pool
522has a non-optimal PG count. Default: `warn`.
523Add as Storage:: Configure a VM or container storage using the new pool.
5b9f923f 524Default: `true` (only visible on creation).
c446b6bb
DW
525
526.Advanced Options
527Min. Size:: The minimum number of replicas per object. Ceph will reject I/O on
528the pool if a PG has less than this many replicas. Default: `2`.
529Crush Rule:: The rule to use for mapping object placement in the cluster. These
530rules define how data is placed within the cluster. See
531xref:pve_ceph_device_classes[Ceph CRUSH & device classes] for information on
532device-based rules.
533# of PGs:: The number of placement groups footnoteref:[placement_groups] that
534the pool should have at the beginning. Default: `128`.
513e2f57 535Target Ratio:: The ratio of data that is expected in the pool. The PG
c446b6bb
DW
536autoscaler uses the ratio relative to other ratio sets. It takes precedence
537over the `target size` if both are set.
a0d289ff
DC
538Target Size:: The estimated amount of data expected in the pool. The PG
539autoscaler uses this size to estimate the optimal PG count.
c446b6bb
DW
540Min. # of PGs:: The minimum number of placement groups. This setting is used to
541fine-tune the lower bound of the PG count for that pool. The PG autoscaler
542will not merge PGs below this threshold.
543
1d54c3b4
AA
544Further information on Ceph pool handling can be found in the Ceph pool
545operation footnote:[Ceph pool operation
b46a49ed 546{cephdocs-url}/rados/operations/pools/]
1d54c3b4 547manual.
21394e70 548
166c91fe 549
b3338e29
AA
550Destroy Pools
551~~~~~~~~~~~~~
166c91fe 552
40e6c806 553To destroy a pool via the GUI, select a node in the tree view and go to the
166c91fe 554**Ceph -> Pools** panel. Select the pool to destroy and click the **Destroy**
40e6c806 555button. To confirm the destruction of the pool, you need to enter the pool name.
166c91fe
AA
556
557Run the following command to destroy a pool. Specify the '-remove_storages' to
558also remove the associated storage.
40e6c806 559
166c91fe
AA
560[source,bash]
561----
562pveceph pool destroy <name>
563----
564
40e6c806
DW
565NOTE: Pool deletion runs in the background and can take some time.
566You will notice the data usage in the cluster decreasing throughout this
567process.
166c91fe 568
47d62c84
DW
569
570PG Autoscaler
571~~~~~~~~~~~~~
572
573The PG autoscaler allows the cluster to consider the amount of (expected) data
574stored in each pool and to choose the appropriate pg_num values automatically.
513e2f57 575It is available since Ceph Nautilus.
47d62c84
DW
576
577You may need to activate the PG autoscaler module before adjustments can take
578effect.
40e6c806 579
47d62c84
DW
580[source,bash]
581----
582ceph mgr module enable pg_autoscaler
583----
584
585The autoscaler is configured on a per pool basis and has the following modes:
586
587[horizontal]
588warn:: A health warning is issued if the suggested `pg_num` value differs too
589much from the current value.
590on:: The `pg_num` is adjusted automatically with no need for any manual
591interaction.
592off:: No automatic `pg_num` adjustments are made, and no warning will be issued
40e6c806 593if the PG count is not optimal.
47d62c84 594
40e6c806 595The scaling factor can be adjusted to facilitate future data storage with the
47d62c84
DW
596`target_size`, `target_size_ratio` and the `pg_num_min` options.
597
598WARNING: By default, the autoscaler considers tuning the PG count of a pool if
599it is off by a factor of 3. This will lead to a considerable shift in data
600placement and might introduce a high load on the cluster.
601
602You can find a more in-depth introduction to the PG autoscaler on Ceph's Blog -
603https://ceph.io/rados/new-in-nautilus-pg-merging-and-autotuning/[New in
604Nautilus: PG merging and autotuning].
605
606
76f6eca4 607[[pve_ceph_device_classes]]
9fad507d
AA
608Ceph CRUSH & device classes
609---------------------------
513e2f57
TL
610
611[thumbnail="screenshot/gui-ceph-config.png"]
612
40e6c806
DW
613The footnote:[CRUSH
614https://ceph.com/wp-content/uploads/2016/08/weil-crush-sc06.pdf] (**C**ontrolled
615**R**eplication **U**nder **S**calable **H**ashing) algorithm is at the
616foundation of Ceph.
9fad507d 617
40e6c806
DW
618CRUSH calculates where to store and retrieve data from. This has the
619advantage that no central indexing service is needed. CRUSH works using a map of
9fad507d
AA
620OSDs, buckets (device locations) and rulesets (data replication) for pools.
621
622NOTE: Further information can be found in the Ceph documentation, under the
b46a49ed 623section CRUSH map footnote:[CRUSH map {cephdocs-url}/rados/operations/crush-map/].
9fad507d
AA
624
625This map can be altered to reflect different replication hierarchies. The object
3a433e9b 626replicas can be separated (e.g., failure domains), while maintaining the desired
9fad507d
AA
627distribution.
628
40e6c806
DW
629A common configuration is to use different classes of disks for different Ceph
630pools. For this reason, Ceph introduced device classes with luminous, to
9fad507d
AA
631accommodate the need for easy ruleset generation.
632
633The device classes can be seen in the 'ceph osd tree' output. These classes
634represent their own root bucket, which can be seen with the below command.
635
636[source, bash]
637----
638ceph osd crush tree --show-shadow
639----
640
641Example output form the above command:
642
643[source, bash]
644----
645ID CLASS WEIGHT TYPE NAME
646-16 nvme 2.18307 root default~nvme
647-13 nvme 0.72769 host sumi1~nvme
648 12 nvme 0.72769 osd.12
649-14 nvme 0.72769 host sumi2~nvme
650 13 nvme 0.72769 osd.13
651-15 nvme 0.72769 host sumi3~nvme
652 14 nvme 0.72769 osd.14
653 -1 7.70544 root default
654 -3 2.56848 host sumi1
655 12 nvme 0.72769 osd.12
656 -5 2.56848 host sumi2
657 13 nvme 0.72769 osd.13
658 -7 2.56848 host sumi3
659 14 nvme 0.72769 osd.14
660----
661
40e6c806
DW
662To instruct a pool to only distribute objects on a specific device class, you
663first need to create a ruleset for the device class:
9fad507d
AA
664
665[source, bash]
666----
667ceph osd crush rule create-replicated <rule-name> <root> <failure-domain> <class>
668----
669
670[frame="none",grid="none", align="left", cols="30%,70%"]
671|===
672|<rule-name>|name of the rule, to connect with a pool (seen in GUI & CLI)
673|<root>|which crush root it should belong to (default ceph root "default")
674|<failure-domain>|at which failure-domain the objects should be distributed (usually host)
3a433e9b 675|<class>|what type of OSD backing store to use (e.g., nvme, ssd, hdd)
9fad507d
AA
676|===
677
678Once the rule is in the CRUSH map, you can tell a pool to use the ruleset.
679
680[source, bash]
681----
682ceph osd pool set <pool-name> crush_rule <rule-name>
683----
684
40e6c806
DW
685TIP: If the pool already contains objects, these must be moved accordingly.
686Depending on your setup, this may introduce a big performance impact on your
687cluster. As an alternative, you can create a new pool and move disks separately.
9fad507d
AA
688
689
21394e70
DM
690Ceph Client
691-----------
692
1ff5e4e8 693[thumbnail="screenshot/gui-ceph-log.png"]
8997dd6e 694
40e6c806
DW
695Following the setup from the previous sections, you can configure {pve} to use
696such pools to store VM and Container images. Simply use the GUI to add a new
513e2f57
TL
697`RBD` storage (see section
698xref:ceph_rados_block_devices[Ceph RADOS Block Devices (RBD)]).
21394e70 699
620d6725 700You also need to copy the keyring to a predefined location for an external Ceph
1d54c3b4
AA
701cluster. If Ceph is installed on the Proxmox nodes itself, then this will be
702done automatically.
21394e70 703
40e6c806
DW
704NOTE: The filename needs to be `<storage_id> + `.keyring`, where `<storage_id>` is
705the expression after 'rbd:' in `/etc/pve/storage.cfg`. In the following example,
706`my-ceph-storage` is the `<storage_id>`:
21394e70
DM
707
708[source,bash]
709----
710mkdir /etc/pve/priv/ceph
711cp /etc/ceph/ceph.client.admin.keyring /etc/pve/priv/ceph/my-ceph-storage.keyring
712----
0840a663 713
58f95dd7
TL
714[[pveceph_fs]]
715CephFS
716------
717
40e6c806
DW
718Ceph also provides a filesystem, which runs on top of the same object storage as
719RADOS block devices do. A **M**eta**d**ata **S**erver (`MDS`) is used to map the
720RADOS backed objects to files and directories, allowing Ceph to provide a
721POSIX-compliant, replicated filesystem. This allows you to easily configure a
722clustered, highly available, shared filesystem. Ceph's Metadata Servers
723guarantee that files are evenly distributed over the entire Ceph cluster. As a
724result, even cases of high load will not overwhelm a single host, which can be
725an issue with traditional shared filesystem approaches, for example `NFS`.
58f95dd7 726
1e834cb2
TL
727[thumbnail="screenshot/gui-node-ceph-cephfs-panel.png"]
728
40e6c806
DW
729{pve} supports both creating a hyper-converged CephFS and using an existing
730xref:storage_cephfs[CephFS as storage] to save backups, ISO files, and container
731templates.
58f95dd7
TL
732
733
734[[pveceph_fs_mds]]
735Metadata Server (MDS)
736~~~~~~~~~~~~~~~~~~~~~
737
40e6c806
DW
738CephFS needs at least one Metadata Server to be configured and running, in order
739to function. You can create an MDS through the {pve} web GUI's `Node
740-> CephFS` panel or from the command line with:
58f95dd7
TL
741
742----
743pveceph mds create
744----
745
40e6c806
DW
746Multiple metadata servers can be created in a cluster, but with the default
747settings, only one can be active at a time. If an MDS or its node becomes
58f95dd7 748unresponsive (or crashes), another `standby` MDS will get promoted to `active`.
40e6c806
DW
749You can speed up the handover between the active and standby MDS by using
750the 'hotstandby' parameter option on creation, or if you have already created it
58f95dd7
TL
751you may set/add:
752
753----
754mds standby replay = true
755----
756
40e6c806
DW
757in the respective MDS section of `/etc/pve/ceph.conf`. With this enabled, the
758specified MDS will remain in a `warm` state, polling the active one, so that it
759can take over faster in case of any issues.
760
761NOTE: This active polling will have an additional performance impact on your
762system and the active `MDS`.
58f95dd7 763
1e834cb2 764.Multiple Active MDS
58f95dd7 765
40e6c806
DW
766Since Luminous (12.2.x) you can have multiple active metadata servers
767running at once, but this is normally only useful if you have a high amount of
768clients running in parallel. Otherwise the `MDS` is rarely the bottleneck in a
769system. If you want to set this up, please refer to the Ceph documentation.
770footnote:[Configuring multiple active MDS daemons
771{cephdocs-url}/cephfs/multimds/]
58f95dd7
TL
772
773[[pveceph_fs_create]]
8a38333f
AA
774Create CephFS
775~~~~~~~~~~~~~
58f95dd7 776
40e6c806
DW
777With {pve}'s integration of CephFS, you can easily create a CephFS using the
778web interface, CLI or an external API interface. Some prerequisites are required
58f95dd7
TL
779for this to work:
780
781.Prerequisites for a successful CephFS setup:
40e6c806
DW
782- xref:pve_ceph_install[Install Ceph packages] - if this was already done some
783time ago, you may want to rerun it on an up-to-date system to
784ensure that all CephFS related packages get installed.
58f95dd7
TL
785- xref:pve_ceph_monitors[Setup Monitors]
786- xref:pve_ceph_monitors[Setup your OSDs]
787- xref:pveceph_fs_mds[Setup at least one MDS]
788
40e6c806 789After this is complete, you can simply create a CephFS through
58f95dd7 790either the Web GUI's `Node -> CephFS` panel or the command line tool `pveceph`,
40e6c806 791for example:
58f95dd7
TL
792
793----
794pveceph fs create --pg_num 128 --add-storage
795----
796
40e6c806
DW
797This creates a CephFS named 'cephfs', using a pool for its data named
798'cephfs_data' with '128' placement groups and a pool for its metadata named
799'cephfs_metadata' with one quarter of the data pool's placement groups (`32`).
58f95dd7 800Check the xref:pve_ceph_pools[{pve} managed Ceph pool chapter] or visit the
40e6c806 801Ceph documentation for more information regarding an appropriate placement group
c446b6bb 802number (`pg_num`) for your setup footnoteref:[placement_groups].
40e6c806 803Additionally, the '--add-storage' parameter will add the CephFS to the {pve}
c446b6bb 804storage configuration after it has been created successfully.
58f95dd7
TL
805
806Destroy CephFS
807~~~~~~~~~~~~~~
808
40e6c806 809WARNING: Destroying a CephFS will render all of its data unusable. This cannot be
58f95dd7
TL
810undone!
811
54f20853
TL
812To completely and gracefully remove a CephFS, the following steps are
813necessary:
58f95dd7 814
b631c35e
DC
815* Disconnect every non-{PVE} client (e.g. unmount the CephFS in guests).
816* Disable all related CephFS {PVE} storage entries (to prevent it from being
817 automatically mounted).
818* Remove all used resources from guests (e.g. ISOs) that are on the CephFS you
819 want to destroy.
820* Unmount the CephFS storages on all cluster nodes manually with
821+
58f95dd7 822----
b631c35e 823umount /mnt/pve/<STORAGE-NAME>
58f95dd7 824----
b631c35e
DC
825+
826Where `<STORAGE-NAME>` is the name of the CephFS storage in your {PVE}.
58f95dd7 827
b631c35e 828* Now make sure that no metadata server (`MDS`) is running for that CephFS,
54f20853
TL
829 either by stopping or destroying them. This can be done through the web
830 interface or via the command line interface, for the latter you would issue
831 the following command:
b631c35e
DC
832+
833----
834pveceph stop --service mds.NAME
58f95dd7 835----
b631c35e
DC
836+
837to stop them, or
838+
839----
840pveceph mds destroy NAME
58f95dd7 841----
b631c35e
DC
842+
843to destroy them.
844+
845Note that standby servers will automatically be promoted to active when an
846active `MDS` is stopped or removed, so it is best to first stop all standby
847servers.
58f95dd7 848
b631c35e
DC
849* Now you can destroy the CephFS with
850+
58f95dd7 851----
b631c35e 852pveceph fs destroy NAME --remove-storages --remove-pools
58f95dd7 853----
b631c35e
DC
854+
855This will automatically destroy the underlying ceph pools as well as remove
856the storages from pve config.
0840a663 857
b631c35e
DC
858After these steps, the CephFS should be completely removed and if you have
859other CephFS instances, the stopped metadata servers can be started again
860to act as standbys.
6ff32926 861
081cb761
AA
862Ceph maintenance
863----------------
af6f59f4 864
081cb761
AA
865Replace OSDs
866~~~~~~~~~~~~
af6f59f4 867
40e6c806
DW
868One of the most common maintenance tasks in Ceph is to replace the disk of an
869OSD. If a disk is already in a failed state, then you can go ahead and run
870through the steps in xref:pve_ceph_osd_destroy[Destroy OSDs]. Ceph will recreate
871those copies on the remaining OSDs if possible. This rebalancing will start as
872soon as an OSD failure is detected or an OSD was actively stopped.
af6f59f4
TL
873
874NOTE: With the default size/min_size (3/2) of a pool, recovery only starts when
875`size + 1` nodes are available. The reason for this is that the Ceph object
876balancer xref:pve_ceph_device_classes[CRUSH] defaults to a full node as
877`failure domain'.
081cb761 878
40e6c806 879To replace a functioning disk from the GUI, go through the steps in
081cb761
AA
880xref:pve_ceph_osd_destroy[Destroy OSDs]. The only addition is to wait until
881the cluster shows 'HEALTH_OK' before stopping the OSD to destroy it.
882
40e6c806
DW
883On the command line, use the following commands:
884
081cb761
AA
885----
886ceph osd out osd.<id>
887----
888
889You can check with the command below if the OSD can be safely removed.
40e6c806 890
081cb761
AA
891----
892ceph osd safe-to-destroy osd.<id>
893----
894
40e6c806
DW
895Once the above check tells you that it is safe to remove the OSD, you can
896continue with the following commands:
897
081cb761
AA
898----
899systemctl stop ceph-osd@<id>.service
900pveceph osd destroy <id>
901----
902
903Replace the old disk with the new one and use the same procedure as described
904in xref:pve_ceph_osd_create[Create OSDs].
905
835f322d
TL
906Trim/Discard
907~~~~~~~~~~~~
40e6c806
DW
908
909It is good practice to run 'fstrim' (discard) regularly on VMs and containers.
081cb761 910This releases data blocks that the filesystem isn’t using anymore. It reduces
c78cd2b6
AA
911data usage and resource load. Most modern operating systems issue such discard
912commands to their disks regularly. You only need to ensure that the Virtual
913Machines enable the xref:qm_hard_disk_discard[disk discard option].
081cb761 914
c998bdf2 915[[pveceph_scrub]]
081cb761
AA
916Scrub & Deep Scrub
917~~~~~~~~~~~~~~~~~~
40e6c806 918
081cb761
AA
919Ceph ensures data integrity by 'scrubbing' placement groups. Ceph checks every
920object in a PG for its health. There are two forms of Scrubbing, daily
b16f8c5f
TL
921cheap metadata checks and weekly deep data checks. The weekly deep scrub reads
922the objects and uses checksums to ensure data integrity. If a running scrub
923interferes with business (performance) needs, you can adjust the time when
b46a49ed 924scrubs footnote:[Ceph scrubbing {cephdocs-url}/rados/configuration/osd-config-ref/#scrubbing]
081cb761
AA
925are executed.
926
927
40e6c806 928Ceph Monitoring and Troubleshooting
10df14fb 929-----------------------------------
40e6c806
DW
930
931It is important to continuously monitor the health of a Ceph deployment from the
932beginning, either by using the Ceph tools or by accessing
10df14fb 933the status through the {pve} link:api-viewer/index.html[API].
6ff32926 934
40e6c806 935The following Ceph commands can be used to see if the cluster is healthy
10df14fb 936('HEALTH_OK'), if there are warnings ('HEALTH_WARN'), or even errors
40e6c806 937('HEALTH_ERR'). If the cluster is in an unhealthy state, the status commands
620d6725 938below will also give you an overview of the current events and actions to take.
6ff32926
AA
939
940----
10df14fb
TL
941# single time output
942pve# ceph -s
943# continuously output status changes (press CTRL+C to stop)
944pve# ceph -w
6ff32926
AA
945----
946
40e6c806
DW
947To get a more detailed view, every Ceph service has a log file under
948`/var/log/ceph/`. If more detail is required, the log level can be
b46a49ed 949adjusted footnote:[Ceph log and debugging {cephdocs-url}/rados/troubleshooting/log-and-debug/].
6ff32926
AA
950
951You can find more information about troubleshooting
b46a49ed 952footnote:[Ceph troubleshooting {cephdocs-url}/rados/troubleshooting/]
620d6725 953a Ceph cluster on the official website.
6ff32926
AA
954
955
0840a663
DM
956ifdef::manvolnum[]
957include::pve-copyright.adoc[]
958endif::manvolnum[]