1 `acpi`: `<boolean>` ('default =' `1`)::
2
3 Enable/disable ACPI.
4
5 `agent`: `<boolean>` ('default =' `0`)::
6
7 Enable/disable Qemu GuestAgent.
8
9 `args`: `<string>` ::
10
11 Arbitrary arguments passed to kvm, for example:
12 +
13 args: -no-reboot -no-hpet
14 +
15 NOTE: this option is for experts only.
16
17 `autostart`: `<boolean>` ('default =' `0`)::
18
19 Automatic restart after crash (currently ignored).
20
21 `balloon`: `<integer> (0 - N)` ::
22
23 Amount of target RAM for the VM in MB. Using zero disables the ballon driver.
24
25 `bios`: `<ovmf | seabios>` ('default =' `seabios`)::
26
27 Select BIOS implementation.
28
29 `boot`: `[acdn]{1,4}` ('default =' `cdn`)::
30
31 Boot on floppy (a), hard disk (c), CD-ROM (d), or network (n).
32
33 `bootdisk`: `(ide|sata|scsi|virtio)\d+` ::
34
35 Enable booting from specified disk.
36
37 `cdrom`: `<volume>` ::
38
39 This is an alias for option -ide2
40
41 `cipassword`: `<string>` ::
42
43 cloud-init: Password to assign the user. Using this is generally not recommended. Use ssh keys instead. Also note that older cloud-init versions do not support hashed passwords.
44
45 `citype`: `<configdrive2 | nocloud>` ::
46
47 Specifies the cloud-init configuration format. The default depends on the configured operating system type (`ostype`. We use the `nocloud` format for Linux, and `configdrive2` for windows.
48
49 `ciuser`: `<string>` ::
50
51 cloud-init: User name to change ssh keys and password for instead of the image's configured default user.
52
53 `cores`: `<integer> (1 - N)` ('default =' `1`)::
54
55 The number of cores per socket.
56
57 `cpu`: `[cputype=]<enum> [,flags=<+FLAG[;-FLAG...]>] [,hidden=<1|0>]` ::
58
59 Emulated CPU type.
60
61 `cputype`=`<486 | Broadwell | Broadwell-IBRS | Broadwell-noTSX | Broadwell-noTSX-IBRS | Conroe | EPYC | EPYC-IBPB | Haswell | Haswell-IBRS | Haswell-noTSX | Haswell-noTSX-IBRS | IvyBridge | IvyBridge-IBRS | Nehalem | Nehalem-IBRS | Opteron_G1 | Opteron_G2 | Opteron_G3 | Opteron_G4 | Opteron_G5 | Penryn | SandyBridge | SandyBridge-IBRS | Skylake-Client | Skylake-Client-IBRS | Skylake-Server | Skylake-Server-IBRS | Westmere | Westmere-IBRS | athlon | core2duo | coreduo | host | kvm32 | kvm64 | max | pentium | pentium2 | pentium3 | phenom | qemu32 | qemu64>` ('default =' `kvm64`);;
62
63 Emulated CPU type.
64
65 `flags`=`<+FLAG[;-FLAG...]>` ;;
66
67 List of additional CPU flags separated by ';'. Use '+FLAG' to enable, '-FLAG' to disable a flag. Currently supported flags: 'pcid', 'spec-ctrl'.
68
69 `hidden`=`<boolean>` ('default =' `0`);;
70
71 Do not identify as a KVM virtual machine.
72
73 `cpulimit`: `<number> (0 - 128)` ('default =' `0`)::
74
75 Limit of CPU usage.
76 +
77 NOTE: If the computer has 2 CPUs, it has total of '2' CPU time. Value '0' indicates no CPU limit.
78
79 `cpuunits`: `<integer> (2 - 262144)` ('default =' `1024`)::
80
81 CPU weight for a VM. Argument is used in the kernel fair scheduler. The larger the number is, the more CPU time this VM gets. Number is relative to weights of all the other running VMs.
82
83 `description`: `<string>` ::
84
85 Description for the VM. Only used on the configuration web interface. This is saved as comment inside the configuration file.
86
87 `efidisk0`: `[file=]<volume> [,format=<enum>] [,size=<DiskSize>]` ::
88
89 Configure a Disk for storing EFI vars
90
91 `file`=`<volume>` ;;
92
93 The drive's backing volume.
94
95 `format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
96
97 The drive's backing file's data format.
98
99 `size`=`<DiskSize>` ;;
100
101 Disk size. This is purely informational and has no effect.
102
103 `freeze`: `<boolean>` ::
104
105 Freeze CPU at startup (use 'c' monitor command to start execution).
106
107 `hostpci[n]`: `[host=]<HOSTPCIID[;HOSTPCIID2...]> [,pcie=<1|0>] [,rombar=<1|0>] [,romfile=<string>] [,x-vga=<1|0>]` ::
108
109 Map host PCI devices into guest.
110 +
111 NOTE: This option allows direct access to host hardware. So it is no longer
112 possible to migrate such machines - use with special care.
113 +
114 CAUTION: Experimental! User reported problems with this option.
115
116 `host`=`<HOSTPCIID[;HOSTPCIID2...]>` ;;
117
118 Host PCI device pass through. The PCI ID of a host's PCI device or a list
119 of PCI virtual functions of the host. HOSTPCIID syntax is:
120 +
121 'bus:dev.func' (hexadecimal numbers)
122 +
123 You can us the 'lspci' command to list existing PCI devices.
124
125 `pcie`=`<boolean>` ('default =' `0`);;
126
127 Choose the PCI-express bus (needs the 'q35' machine model).
128
129 `rombar`=`<boolean>` ('default =' `1`);;
130
131 Specify whether or not the device's ROM will be visible in the guest's memory map.
132
133 `romfile`=`<string>` ;;
134
135 Custom pci device rom filename (must be located in /usr/share/kvm/).
136
137 `x-vga`=`<boolean>` ('default =' `0`);;
138
139 Enable vfio-vga device support.
140
141 `hotplug`: `<string>` ('default =' `network,disk,usb`)::
142
143 Selectively enable hotplug features. This is a comma separated list of hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to disable hotplug completely. Value '1' is an alias for the default 'network,disk,usb'.
144
145 `hugepages`: `<1024 | 2 | any>` ::
146
147 Enable/disable hugepages memory.
148
149 `ide[n]`: `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,model=<model>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
150
151 Use volume as IDE hard disk or CD-ROM (n is 0 to 3).
152
153 `aio`=`<native | threads>` ;;
154
155 AIO type to use.
156
157 `backup`=`<boolean>` ;;
158
159 Whether the drive should be included when making backups.
160
161 `bps`=`<bps>` ;;
162
163 Maximum r/w speed in bytes per second.
164
165 `bps_max_length`=`<seconds>` ;;
166
167 Maximum length of I/O bursts in seconds.
168
169 `bps_rd`=`<bps>` ;;
170
171 Maximum read speed in bytes per second.
172
173 `bps_rd_max_length`=`<seconds>` ;;
174
175 Maximum length of read I/O bursts in seconds.
176
177 `bps_wr`=`<bps>` ;;
178
179 Maximum write speed in bytes per second.
180
181 `bps_wr_max_length`=`<seconds>` ;;
182
183 Maximum length of write I/O bursts in seconds.
184
185 `cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
186
187 The drive's cache mode
188
189 `cyls`=`<integer>` ;;
190
191 Force the drive's physical geometry to have a specific cylinder count.
192
193 `detect_zeroes`=`<boolean>` ;;
194
195 Controls whether to detect and try to optimize writes of zeroes.
196
197 `discard`=`<ignore | on>` ;;
198
199 Controls whether to pass discard/trim requests to the underlying storage.
200
201 `file`=`<volume>` ;;
202
203 The drive's backing volume.
204
205 `format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
206
207 The drive's backing file's data format.
208
209 `heads`=`<integer>` ;;
210
211 Force the drive's physical geometry to have a specific head count.
212
213 `iops`=`<iops>` ;;
214
215 Maximum r/w I/O in operations per second.
216
217 `iops_max`=`<iops>` ;;
218
219 Maximum unthrottled r/w I/O pool in operations per second.
220
221 `iops_max_length`=`<seconds>` ;;
222
223 Maximum length of I/O bursts in seconds.
224
225 `iops_rd`=`<iops>` ;;
226
227 Maximum read I/O in operations per second.
228
229 `iops_rd_max`=`<iops>` ;;
230
231 Maximum unthrottled read I/O pool in operations per second.
232
233 `iops_rd_max_length`=`<seconds>` ;;
234
235 Maximum length of read I/O bursts in seconds.
236
237 `iops_wr`=`<iops>` ;;
238
239 Maximum write I/O in operations per second.
240
241 `iops_wr_max`=`<iops>` ;;
242
243 Maximum unthrottled write I/O pool in operations per second.
244
245 `iops_wr_max_length`=`<seconds>` ;;
246
247 Maximum length of write I/O bursts in seconds.
248
249 `mbps`=`<mbps>` ;;
250
251 Maximum r/w speed in megabytes per second.
252
253 `mbps_max`=`<mbps>` ;;
254
255 Maximum unthrottled r/w pool in megabytes per second.
256
257 `mbps_rd`=`<mbps>` ;;
258
259 Maximum read speed in megabytes per second.
260
261 `mbps_rd_max`=`<mbps>` ;;
262
263 Maximum unthrottled read pool in megabytes per second.
264
265 `mbps_wr`=`<mbps>` ;;
266
267 Maximum write speed in megabytes per second.
268
269 `mbps_wr_max`=`<mbps>` ;;
270
271 Maximum unthrottled write pool in megabytes per second.
272
273 `media`=`<cdrom | disk>` ('default =' `disk`);;
274
275 The drive's media type.
276
277 `model`=`<model>` ;;
278
279 The drive's reported model name, url-encoded, up to 40 bytes long.
280
281 `replicate`=`<boolean>` ('default =' `1`);;
282
283 Whether the drive should considered for replication jobs.
284
285 `rerror`=`<ignore | report | stop>` ;;
286
287 Read error action.
288
289 `secs`=`<integer>` ;;
290
291 Force the drive's physical geometry to have a specific sector count.
292
293 `serial`=`<serial>` ;;
294
295 The drive's reported serial number, url-encoded, up to 20 bytes long.
296
297 `shared`=`<boolean>` ('default =' `0`);;
298
299 Mark this locally-managed volume as available on all nodes.
300 +
301 WARNING: This option does not share the volume automatically, it assumes it is shared already!
302
303 `size`=`<DiskSize>` ;;
304
305 Disk size. This is purely informational and has no effect.
306
307 `snapshot`=`<boolean>` ;;
308
309 Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
310
311 `trans`=`<auto | lba | none>` ;;
312
313 Force disk geometry bios translation mode.
314
315 `werror`=`<enospc | ignore | report | stop>` ;;
316
317 Write error action.
318
319 `ipconfig[n]`: `[gw=<GatewayIPv4>] [,gw6=<GatewayIPv6>] [,ip=<IPv4Format/CIDR>] [,ip6=<IPv6Format/CIDR>]` ::
320
321 cloud-init: Specify IP addresses and gateways for the corresponding interface.
322 +
323 IP addresses use CIDR notation, gateways are optional but need an IP of the same type specified.
324 +
325 The special string 'dhcp' can be used for IP addresses to use DHCP, in which case no explicit gateway should be provided.
326 For IPv6 the special string 'auto' can be used to use stateless autoconfiguration.
327 +
328 If cloud-init is enabled and neither an IPv4 nor an IPv6 address is specified, it defaults to using dhcp on IPv4.
329
330 `gw`=`<GatewayIPv4>` ;;
331
332 Default gateway for IPv4 traffic.
333 +
334 NOTE: Requires option(s): `ip`
335
336 `gw6`=`<GatewayIPv6>` ;;
337
338 Default gateway for IPv6 traffic.
339 +
340 NOTE: Requires option(s): `ip6`
341
342 `ip`=`<IPv4Format/CIDR>` ('default =' `dhcp`);;
343
344 IPv4 address in CIDR format.
345
346 `ip6`=`<IPv6Format/CIDR>` ('default =' `dhcp`);;
347
348 IPv6 address in CIDR format.
349
350 `keyboard`: `<da | de | de-ch | en-gb | en-us | es | fi | fr | fr-be | fr-ca | fr-ch | hu | is | it | ja | lt | mk | nl | no | pl | pt | pt-br | sl | sv | tr>` ::
351
352 Keybord layout for vnc server. Default is read from the '/etc/pve/datacenter.cfg' configuration file.It should not be necessary to set it.
353
354 `kvm`: `<boolean>` ('default =' `1`)::
355
356 Enable/disable KVM hardware virtualization.
357
358 `localtime`: `<boolean>` ::
359
360 Set the real time clock to local time. This is enabled by default if ostype indicates a Microsoft OS.
361
362 `lock`: `<backup | migrate | rollback | snapshot>` ::
363
364 Lock/unlock the VM.
365
366 `machine`: `(pc|pc(-i440fx)?-\d+\.\d+(\.pxe)?|q35|pc-q35-\d+\.\d+(\.pxe)?)` ::
367
368 Specific the Qemu machine type.
369
370 `memory`: `<integer> (16 - N)` ('default =' `512`)::
371
372 Amount of RAM for the VM in MB. This is the maximum available memory when you use the balloon device.
373
374 `migrate_downtime`: `<number> (0 - N)` ('default =' `0.1`)::
375
376 Set maximum tolerated downtime (in seconds) for migrations.
377
378 `migrate_speed`: `<integer> (0 - N)` ('default =' `0`)::
379
380 Set maximum speed (in MB/s) for migrations. Value 0 is no limit.
381
382 `name`: `<string>` ::
383
384 Set a name for the VM. Only used on the configuration web interface.
385
386 `nameserver`: `<string>` ::
387
388 cloud-init: Sets DNS server IP address for a container. Create will automatically use the setting from the host if neither searchdomain nor nameserver are set.
389
390 `net[n]`: `[model=]<enum> [,bridge=<bridge>] [,firewall=<1|0>] [,link_down=<1|0>] [,macaddr=<XX:XX:XX:XX:XX:XX>] [,queues=<integer>] [,rate=<number>] [,tag=<integer>] [,trunks=<vlanid[;vlanid...]>] [,<model>=<macaddr>]` ::
391
392 Specify network devices.
393
394 `bridge`=`<bridge>` ;;
395
396 Bridge to attach the network device to. The Proxmox VE standard bridge
397 is called 'vmbr0'.
398 +
399 If you do not specify a bridge, we create a kvm user (NATed) network
400 device, which provides DHCP and DNS services. The following addresses
401 are used:
402 +
403 10.0.2.2 Gateway
404 10.0.2.3 DNS Server
405 10.0.2.4 SMB Server
406 +
407 The DHCP server assign addresses to the guest starting from 10.0.2.15.
408
409 `firewall`=`<boolean>` ;;
410
411 Whether this interface should be protected by the firewall.
412
413 `link_down`=`<boolean>` ;;
414
415 Whether this interface should be disconnected (like pulling the plug).
416
417 `macaddr`=`<XX:XX:XX:XX:XX:XX>` ;;
418
419 MAC address. That address must be unique withing your network. This is automatically generated if not specified.
420
421 `model`=`<e1000 | e1000-82540em | e1000-82544gc | e1000-82545em | i82551 | i82557b | i82559er | ne2k_isa | ne2k_pci | pcnet | rtl8139 | virtio | vmxnet3>` ;;
422
423 Network Card Model. The 'virtio' model provides the best performance with very low CPU overhead. If your guest does not support this driver, it is usually best to use 'e1000'.
424
425 `queues`=`<integer> (0 - 16)` ;;
426
427 Number of packet queues to be used on the device.
428
429 `rate`=`<number> (0 - N)` ;;
430
431 Rate limit in mbps (megabytes per second) as floating point number.
432
433 `tag`=`<integer> (1 - 4094)` ;;
434
435 VLAN tag to apply to packets on this interface.
436
437 `trunks`=`<vlanid[;vlanid...]>` ;;
438
439 VLAN trunks to pass through this interface.
440
441 `numa`: `<boolean>` ('default =' `0`)::
442
443 Enable/disable NUMA.
444
445 `numa[n]`: `cpus=<id[-id];...> [,hostnodes=<id[-id];...>] [,memory=<number>] [,policy=<preferred|bind|interleave>]` ::
446
447 NUMA topology.
448
449 `cpus`=`<id[-id];...>` ;;
450
451 CPUs accessing this NUMA node.
452
453 `hostnodes`=`<id[-id];...>` ;;
454
455 Host NUMA nodes to use.
456
457 `memory`=`<number>` ;;
458
459 Amount of memory this NUMA node provides.
460
461 `policy`=`<bind | interleave | preferred>` ;;
462
463 NUMA allocation policy.
464
465 `onboot`: `<boolean>` ('default =' `0`)::
466
467 Specifies whether a VM will be started during system bootup.
468
469 `ostype`: `<l24 | l26 | other | solaris | w2k | w2k3 | w2k8 | win10 | win7 | win8 | wvista | wxp>` ::
470
471 Specify guest operating system. This is used to enable special
472 optimization/features for specific operating systems:
473 +
474 [horizontal]
475 other;; unspecified OS
476 wxp;; Microsoft Windows XP
477 w2k;; Microsoft Windows 2000
478 w2k3;; Microsoft Windows 2003
479 w2k8;; Microsoft Windows 2008
480 wvista;; Microsoft Windows Vista
481 win7;; Microsoft Windows 7
482 win8;; Microsoft Windows 8/2012/2012r2
483 win10;; Microsoft Windows 10/2016
484 l24;; Linux 2.4 Kernel
485 l26;; Linux 2.6/3.X Kernel
486 solaris;; Solaris/OpenSolaris/OpenIndiania kernel
487
488 `parallel[n]`: `/dev/parport\d+|/dev/usb/lp\d+` ::
489
490 Map host parallel devices (n is 0 to 2).
491 +
492 NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such machines - use with special care.
493 +
494 CAUTION: Experimental! User reported problems with this option.
495
496 `protection`: `<boolean>` ('default =' `0`)::
497
498 Sets the protection flag of the VM. This will disable the remove VM and remove disk operations.
499
500 `reboot`: `<boolean>` ('default =' `1`)::
501
502 Allow reboot. If set to '0' the VM exit on reboot.
503
504 `sata[n]`: `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
505
506 Use volume as SATA hard disk or CD-ROM (n is 0 to 5).
507
508 `aio`=`<native | threads>` ;;
509
510 AIO type to use.
511
512 `backup`=`<boolean>` ;;
513
514 Whether the drive should be included when making backups.
515
516 `bps`=`<bps>` ;;
517
518 Maximum r/w speed in bytes per second.
519
520 `bps_max_length`=`<seconds>` ;;
521
522 Maximum length of I/O bursts in seconds.
523
524 `bps_rd`=`<bps>` ;;
525
526 Maximum read speed in bytes per second.
527
528 `bps_rd_max_length`=`<seconds>` ;;
529
530 Maximum length of read I/O bursts in seconds.
531
532 `bps_wr`=`<bps>` ;;
533
534 Maximum write speed in bytes per second.
535
536 `bps_wr_max_length`=`<seconds>` ;;
537
538 Maximum length of write I/O bursts in seconds.
539
540 `cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
541
542 The drive's cache mode
543
544 `cyls`=`<integer>` ;;
545
546 Force the drive's physical geometry to have a specific cylinder count.
547
548 `detect_zeroes`=`<boolean>` ;;
549
550 Controls whether to detect and try to optimize writes of zeroes.
551
552 `discard`=`<ignore | on>` ;;
553
554 Controls whether to pass discard/trim requests to the underlying storage.
555
556 `file`=`<volume>` ;;
557
558 The drive's backing volume.
559
560 `format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
561
562 The drive's backing file's data format.
563
564 `heads`=`<integer>` ;;
565
566 Force the drive's physical geometry to have a specific head count.
567
568 `iops`=`<iops>` ;;
569
570 Maximum r/w I/O in operations per second.
571
572 `iops_max`=`<iops>` ;;
573
574 Maximum unthrottled r/w I/O pool in operations per second.
575
576 `iops_max_length`=`<seconds>` ;;
577
578 Maximum length of I/O bursts in seconds.
579
580 `iops_rd`=`<iops>` ;;
581
582 Maximum read I/O in operations per second.
583
584 `iops_rd_max`=`<iops>` ;;
585
586 Maximum unthrottled read I/O pool in operations per second.
587
588 `iops_rd_max_length`=`<seconds>` ;;
589
590 Maximum length of read I/O bursts in seconds.
591
592 `iops_wr`=`<iops>` ;;
593
594 Maximum write I/O in operations per second.
595
596 `iops_wr_max`=`<iops>` ;;
597
598 Maximum unthrottled write I/O pool in operations per second.
599
600 `iops_wr_max_length`=`<seconds>` ;;
601
602 Maximum length of write I/O bursts in seconds.
603
604 `mbps`=`<mbps>` ;;
605
606 Maximum r/w speed in megabytes per second.
607
608 `mbps_max`=`<mbps>` ;;
609
610 Maximum unthrottled r/w pool in megabytes per second.
611
612 `mbps_rd`=`<mbps>` ;;
613
614 Maximum read speed in megabytes per second.
615
616 `mbps_rd_max`=`<mbps>` ;;
617
618 Maximum unthrottled read pool in megabytes per second.
619
620 `mbps_wr`=`<mbps>` ;;
621
622 Maximum write speed in megabytes per second.
623
624 `mbps_wr_max`=`<mbps>` ;;
625
626 Maximum unthrottled write pool in megabytes per second.
627
628 `media`=`<cdrom | disk>` ('default =' `disk`);;
629
630 The drive's media type.
631
632 `replicate`=`<boolean>` ('default =' `1`);;
633
634 Whether the drive should considered for replication jobs.
635
636 `rerror`=`<ignore | report | stop>` ;;
637
638 Read error action.
639
640 `secs`=`<integer>` ;;
641
642 Force the drive's physical geometry to have a specific sector count.
643
644 `serial`=`<serial>` ;;
645
646 The drive's reported serial number, url-encoded, up to 20 bytes long.
647
648 `shared`=`<boolean>` ('default =' `0`);;
649
650 Mark this locally-managed volume as available on all nodes.
651 +
652 WARNING: This option does not share the volume automatically, it assumes it is shared already!
653
654 `size`=`<DiskSize>` ;;
655
656 Disk size. This is purely informational and has no effect.
657
658 `snapshot`=`<boolean>` ;;
659
660 Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
661
662 `trans`=`<auto | lba | none>` ;;
663
664 Force disk geometry bios translation mode.
665
666 `werror`=`<enospc | ignore | report | stop>` ;;
667
668 Write error action.
669
670 `scsi[n]`: `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,queues=<integer>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,scsiblock=<1|0>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
671
672 Use volume as SCSI hard disk or CD-ROM (n is 0 to 13).
673
674 `aio`=`<native | threads>` ;;
675
676 AIO type to use.
677
678 `backup`=`<boolean>` ;;
679
680 Whether the drive should be included when making backups.
681
682 `bps`=`<bps>` ;;
683
684 Maximum r/w speed in bytes per second.
685
686 `bps_max_length`=`<seconds>` ;;
687
688 Maximum length of I/O bursts in seconds.
689
690 `bps_rd`=`<bps>` ;;
691
692 Maximum read speed in bytes per second.
693
694 `bps_rd_max_length`=`<seconds>` ;;
695
696 Maximum length of read I/O bursts in seconds.
697
698 `bps_wr`=`<bps>` ;;
699
700 Maximum write speed in bytes per second.
701
702 `bps_wr_max_length`=`<seconds>` ;;
703
704 Maximum length of write I/O bursts in seconds.
705
706 `cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
707
708 The drive's cache mode
709
710 `cyls`=`<integer>` ;;
711
712 Force the drive's physical geometry to have a specific cylinder count.
713
714 `detect_zeroes`=`<boolean>` ;;
715
716 Controls whether to detect and try to optimize writes of zeroes.
717
718 `discard`=`<ignore | on>` ;;
719
720 Controls whether to pass discard/trim requests to the underlying storage.
721
722 `file`=`<volume>` ;;
723
724 The drive's backing volume.
725
726 `format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
727
728 The drive's backing file's data format.
729
730 `heads`=`<integer>` ;;
731
732 Force the drive's physical geometry to have a specific head count.
733
734 `iops`=`<iops>` ;;
735
736 Maximum r/w I/O in operations per second.
737
738 `iops_max`=`<iops>` ;;
739
740 Maximum unthrottled r/w I/O pool in operations per second.
741
742 `iops_max_length`=`<seconds>` ;;
743
744 Maximum length of I/O bursts in seconds.
745
746 `iops_rd`=`<iops>` ;;
747
748 Maximum read I/O in operations per second.
749
750 `iops_rd_max`=`<iops>` ;;
751
752 Maximum unthrottled read I/O pool in operations per second.
753
754 `iops_rd_max_length`=`<seconds>` ;;
755
756 Maximum length of read I/O bursts in seconds.
757
758 `iops_wr`=`<iops>` ;;
759
760 Maximum write I/O in operations per second.
761
762 `iops_wr_max`=`<iops>` ;;
763
764 Maximum unthrottled write I/O pool in operations per second.
765
766 `iops_wr_max_length`=`<seconds>` ;;
767
768 Maximum length of write I/O bursts in seconds.
769
770 `iothread`=`<boolean>` ;;
771
772 Whether to use iothreads for this drive
773
774 `mbps`=`<mbps>` ;;
775
776 Maximum r/w speed in megabytes per second.
777
778 `mbps_max`=`<mbps>` ;;
779
780 Maximum unthrottled r/w pool in megabytes per second.
781
782 `mbps_rd`=`<mbps>` ;;
783
784 Maximum read speed in megabytes per second.
785
786 `mbps_rd_max`=`<mbps>` ;;
787
788 Maximum unthrottled read pool in megabytes per second.
789
790 `mbps_wr`=`<mbps>` ;;
791
792 Maximum write speed in megabytes per second.
793
794 `mbps_wr_max`=`<mbps>` ;;
795
796 Maximum unthrottled write pool in megabytes per second.
797
798 `media`=`<cdrom | disk>` ('default =' `disk`);;
799
800 The drive's media type.
801
802 `queues`=`<integer> (2 - N)` ;;
803
804 Number of queues.
805
806 `replicate`=`<boolean>` ('default =' `1`);;
807
808 Whether the drive should considered for replication jobs.
809
810 `rerror`=`<ignore | report | stop>` ;;
811
812 Read error action.
813
814 `scsiblock`=`<boolean>` ('default =' `0`);;
815
816 whether to use scsi-block for full passthrough of host block device
817 +
818 WARNING: can lead to I/O errors in combination with low memory or high memory fragmentation on host
819
820 `secs`=`<integer>` ;;
821
822 Force the drive's physical geometry to have a specific sector count.
823
824 `serial`=`<serial>` ;;
825
826 The drive's reported serial number, url-encoded, up to 20 bytes long.
827
828 `shared`=`<boolean>` ('default =' `0`);;
829
830 Mark this locally-managed volume as available on all nodes.
831 +
832 WARNING: This option does not share the volume automatically, it assumes it is shared already!
833
834 `size`=`<DiskSize>` ;;
835
836 Disk size. This is purely informational and has no effect.
837
838 `snapshot`=`<boolean>` ;;
839
840 Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
841
842 `trans`=`<auto | lba | none>` ;;
843
844 Force disk geometry bios translation mode.
845
846 `werror`=`<enospc | ignore | report | stop>` ;;
847
848 Write error action.
849
850 `scsihw`: `<lsi | lsi53c810 | megasas | pvscsi | virtio-scsi-pci | virtio-scsi-single>` ('default =' `lsi`)::
851
852 SCSI controller model
853
854 `searchdomain`: `<string>` ::
855
856 cloud-init: Sets DNS search domains for a container. Create will automatically use the setting from the host if neither searchdomain nor nameserver are set.
857
858 `serial[n]`: `(/dev/.+|socket)` ::
859
860 Create a serial device inside the VM (n is 0 to 3), and pass through a
861 host serial device (i.e. /dev/ttyS0), or create a unix socket on the
862 host side (use 'qm terminal' to open a terminal connection).
863 +
864 NOTE: If you pass through a host serial device, it is no longer possible to migrate such machines - use with special care.
865 +
866 CAUTION: Experimental! User reported problems with this option.
867
868 `shares`: `<integer> (0 - 50000)` ('default =' `1000`)::
869
870 Amount of memory shares for auto-ballooning. The larger the number is, the more memory this VM gets. Number is relative to weights of all other running VMs. Using zero disables auto-ballooning. Auto-ballooning is done by pvestatd.
871
872 `smbios1`: `[family=<string>] [,manufacturer=<string>] [,product=<string>] [,serial=<string>] [,sku=<string>] [,uuid=<UUID>] [,version=<string>]` ::
873
874 Specify SMBIOS type 1 fields.
875
876 `family`=`<string>` ;;
877
878 Set SMBIOS1 family string.
879
880 `manufacturer`=`<string>` ;;
881
882 Set SMBIOS1 manufacturer.
883
884 `product`=`<string>` ;;
885
886 Set SMBIOS1 product ID.
887
888 `serial`=`<string>` ;;
889
890 Set SMBIOS1 serial number.
891
892 `sku`=`<string>` ;;
893
894 Set SMBIOS1 SKU string.
895
896 `uuid`=`<UUID>` ;;
897
898 Set SMBIOS1 UUID.
899
900 `version`=`<string>` ;;
901
902 Set SMBIOS1 version.
903
904 `smp`: `<integer> (1 - N)` ('default =' `1`)::
905
906 The number of CPUs. Please use option -sockets instead.
907
908 `sockets`: `<integer> (1 - N)` ('default =' `1`)::
909
910 The number of CPU sockets.
911
912 `sshkeys`: `<string>` ::
913
914 cloud-init: Setup public SSH keys (one key per line, OpenSSH format).
915
916 `startdate`: `(now | YYYY-MM-DD | YYYY-MM-DDTHH:MM:SS)` ('default =' `now`)::
917
918 Set the initial date of the real time clock. Valid format for date are: 'now' or '2006-06-17T16:01:21' or '2006-06-17'.
919
920 `startup`: `[[order=]\d+] [,up=\d+] [,down=\d+] ` ::
921
922 Startup and shutdown behavior. Order is a non-negative number defining the general startup order. Shutdown in done with reverse ordering. Additionally you can set the 'up' or 'down' delay in seconds, which specifies a delay to wait before the next VM is started or stopped.
923
924 `tablet`: `<boolean>` ('default =' `1`)::
925
926 Enable/disable the USB tablet device. This device is usually needed to allow absolute mouse positioning with VNC. Else the mouse runs out of sync with normal VNC clients. If you're running lots of console-only guests on one host, you may consider disabling this to save some context switches. This is turned off by default if you use spice (-vga=qxl).
927
928 `tdf`: `<boolean>` ('default =' `0`)::
929
930 Enable/disable time drift fix.
931
932 `template`: `<boolean>` ('default =' `0`)::
933
934 Enable/disable Template.
935
936 `unused[n]`: `<string>` ::
937
938 Reference to unused volumes. This is used internally, and should not be modified manually.
939
940 `usb[n]`: `[host=]<HOSTUSBDEVICE|spice> [,usb3=<1|0>]` ::
941
942 Configure an USB device (n is 0 to 4).
943
944 `host`=`<HOSTUSBDEVICE|spice>` ;;
945
946 The Host USB device or port or the value 'spice'. HOSTUSBDEVICE syntax is:
947 +
948 'bus-port(.port)*' (decimal numbers) or
949 'vendor_id:product_id' (hexadeciaml numbers) or
950 'spice'
951 +
952 You can use the 'lsusb -t' command to list existing usb devices.
953 +
954 NOTE: This option allows direct access to host hardware. So it is no longer possible to migrate such machines - use with special care.
955 +
956 The value 'spice' can be used to add a usb redirection devices for spice.
957
958 `usb3`=`<boolean>` ('default =' `0`);;
959
960 Specifies whether if given host option is a USB3 device or port (this does currently not work reliably with spice redirection and is then ignored).
961
962 `vcpus`: `<integer> (1 - N)` ('default =' `0`)::
963
964 Number of hotplugged vcpus.
965
966 `vga`: `<cirrus | qxl | qxl2 | qxl3 | qxl4 | serial0 | serial1 | serial2 | serial3 | std | vmware>` ::
967
968 Select the VGA type. If you want to use high resolution modes (>= 1280x1024x16) then you should use the options 'std' or 'vmware'. Default is 'std' for win8/win7/w2k8, and 'cirrus' for other OS types. The 'qxl' option enables the SPICE display sever. For win* OS you can select how many independent displays you want, Linux guests can add displays them self. You can also run without any graphic card, using a serial device as terminal.
969
970 `virtio[n]`: `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_max_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_max_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_rd_max_length=<seconds>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iops_wr_max_length=<seconds>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,replicate=<1|0>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,shared=<1|0>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
971
972 Use volume as VIRTIO hard disk (n is 0 to 15).
973
974 `aio`=`<native | threads>` ;;
975
976 AIO type to use.
977
978 `backup`=`<boolean>` ;;
979
980 Whether the drive should be included when making backups.
981
982 `bps`=`<bps>` ;;
983
984 Maximum r/w speed in bytes per second.
985
986 `bps_max_length`=`<seconds>` ;;
987
988 Maximum length of I/O bursts in seconds.
989
990 `bps_rd`=`<bps>` ;;
991
992 Maximum read speed in bytes per second.
993
994 `bps_rd_max_length`=`<seconds>` ;;
995
996 Maximum length of read I/O bursts in seconds.
997
998 `bps_wr`=`<bps>` ;;
999
1000 Maximum write speed in bytes per second.
1001
1002 `bps_wr_max_length`=`<seconds>` ;;
1003
1004 Maximum length of write I/O bursts in seconds.
1005
1006 `cache`=`<directsync | none | unsafe | writeback | writethrough>` ;;
1007
1008 The drive's cache mode
1009
1010 `cyls`=`<integer>` ;;
1011
1012 Force the drive's physical geometry to have a specific cylinder count.
1013
1014 `detect_zeroes`=`<boolean>` ;;
1015
1016 Controls whether to detect and try to optimize writes of zeroes.
1017
1018 `discard`=`<ignore | on>` ;;
1019
1020 Controls whether to pass discard/trim requests to the underlying storage.
1021
1022 `file`=`<volume>` ;;
1023
1024 The drive's backing volume.
1025
1026 `format`=`<cloop | cow | qcow | qcow2 | qed | raw | vmdk>` ;;
1027
1028 The drive's backing file's data format.
1029
1030 `heads`=`<integer>` ;;
1031
1032 Force the drive's physical geometry to have a specific head count.
1033
1034 `iops`=`<iops>` ;;
1035
1036 Maximum r/w I/O in operations per second.
1037
1038 `iops_max`=`<iops>` ;;
1039
1040 Maximum unthrottled r/w I/O pool in operations per second.
1041
1042 `iops_max_length`=`<seconds>` ;;
1043
1044 Maximum length of I/O bursts in seconds.
1045
1046 `iops_rd`=`<iops>` ;;
1047
1048 Maximum read I/O in operations per second.
1049
1050 `iops_rd_max`=`<iops>` ;;
1051
1052 Maximum unthrottled read I/O pool in operations per second.
1053
1054 `iops_rd_max_length`=`<seconds>` ;;
1055
1056 Maximum length of read I/O bursts in seconds.
1057
1058 `iops_wr`=`<iops>` ;;
1059
1060 Maximum write I/O in operations per second.
1061
1062 `iops_wr_max`=`<iops>` ;;
1063
1064 Maximum unthrottled write I/O pool in operations per second.
1065
1066 `iops_wr_max_length`=`<seconds>` ;;
1067
1068 Maximum length of write I/O bursts in seconds.
1069
1070 `iothread`=`<boolean>` ;;
1071
1072 Whether to use iothreads for this drive
1073
1074 `mbps`=`<mbps>` ;;
1075
1076 Maximum r/w speed in megabytes per second.
1077
1078 `mbps_max`=`<mbps>` ;;
1079
1080 Maximum unthrottled r/w pool in megabytes per second.
1081
1082 `mbps_rd`=`<mbps>` ;;
1083
1084 Maximum read speed in megabytes per second.
1085
1086 `mbps_rd_max`=`<mbps>` ;;
1087
1088 Maximum unthrottled read pool in megabytes per second.
1089
1090 `mbps_wr`=`<mbps>` ;;
1091
1092 Maximum write speed in megabytes per second.
1093
1094 `mbps_wr_max`=`<mbps>` ;;
1095
1096 Maximum unthrottled write pool in megabytes per second.
1097
1098 `media`=`<cdrom | disk>` ('default =' `disk`);;
1099
1100 The drive's media type.
1101
1102 `replicate`=`<boolean>` ('default =' `1`);;
1103
1104 Whether the drive should considered for replication jobs.
1105
1106 `rerror`=`<ignore | report | stop>` ;;
1107
1108 Read error action.
1109
1110 `secs`=`<integer>` ;;
1111
1112 Force the drive's physical geometry to have a specific sector count.
1113
1114 `serial`=`<serial>` ;;
1115
1116 The drive's reported serial number, url-encoded, up to 20 bytes long.
1117
1118 `shared`=`<boolean>` ('default =' `0`);;
1119
1120 Mark this locally-managed volume as available on all nodes.
1121 +
1122 WARNING: This option does not share the volume automatically, it assumes it is shared already!
1123
1124 `size`=`<DiskSize>` ;;
1125
1126 Disk size. This is purely informational and has no effect.
1127
1128 `snapshot`=`<boolean>` ;;
1129
1130 Controls qemu's snapshot mode feature. If activated, changes made to the disk are temporary and will be discarded when the VM is shutdown.
1131
1132 `trans`=`<auto | lba | none>` ;;
1133
1134 Force disk geometry bios translation mode.
1135
1136 `werror`=`<enospc | ignore | report | stop>` ;;
1137
1138 Write error action.
1139
1140 `vmstatestorage`: `<string>` ::
1141
1142 Default storage for VM state volumes/files.
1143
1144 `watchdog`: `[[model=]<i6300esb|ib700>] [,action=<enum>]` ::
1145
1146 Create a virtual hardware watchdog device. Once enabled (by a guest action), the watchdog must be periodically polled by an agent inside the guest or else the watchdog will reset the guest (or execute the respective action specified)
1147
1148 `action`=`<debug | none | pause | poweroff | reset | shutdown>` ;;
1149
1150 The action to perform if after activation the guest fails to poll the watchdog in time.
1151
1152 `model`=`<i6300esb | ib700>` ('default =' `i6300esb`);;