]> git.proxmox.com Git - pve-docs.git/blobdiff - qm.1-synopsis.adoc
update generated docs
[pve-docs.git] / qm.1-synopsis.adoc
index 45c2206684ea9c50e3eb9c0d860dc896650da98a..d45a18b2d9aa9e62396a49490507bdc1b1d84a2e 100644 (file)
@@ -1,51 +1,64 @@
 *qm* `<COMMAND> [ARGS] [OPTIONS]`
 
+*qm agent* `<vmid> <command>`
+
+Execute Qemu Guest Agent commands.
+
+`<vmid>`: `<integer> (1 - N)` ::
+
+The (unique) ID of the VM.
+
+`<command>`: `<fsfreeze-freeze | fsfreeze-status | fsfreeze-thaw | fstrim | get-fsinfo | get-memory-block-info | get-memory-blocks | get-time | get-vcpus | info | network-get-interfaces | ping | shutdown | suspend-disk | suspend-hybrid | suspend-ram>` ::
+
+The QGA command.
+
+
+
 *qm clone* `<vmid> <newid>` `[OPTIONS]`
 
 Create a copy of virtual machine/template.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`<newid>` `integer (1 - N)` ::
+`<newid>`: `<integer> (1 - N)` ::
 
 VMID for the clone.
 
-`-description` `string` ::
+`-description` `<string>` ::
 
 Description for the new VM.
 
-`-format` `(qcow2 | raw | vmdk)` ::
+`-format` `<qcow2 | raw | vmdk>` ::
 
 Target format for file storage.
 +
 NOTE: Requires option(s): `full`
 
-`-full` `boolean` (default=`0`)::
+`-full` `<boolean>` ('default =' `0`)::
 
-Create a full copy of all disk. This is always done when you clone a normal
-VM. For VM templates, we try to create a linked clone by default.
+Create a full copy of all disk. This is always done when you clone a normal VM. For VM templates, we try to create a linked clone by default.
 
-`-name` `string` ::
+`-name` `<string>` ::
 
 Set a name for the new VM.
 
-`-pool` `string` ::
+`-pool` `<string>` ::
 
 Add the new VM to the specified pool.
 
-`-snapname` `string` ::
+`-snapname` `<string>` ::
 
 The name of the snapshot.
 
-`-storage` `string` ::
+`-storage` `<string>` ::
 
 Target storage for full clone.
 +
 NOTE: Requires option(s): `full`
 
-`-target` `string` ::
+`-target` `<string>` ::
 
 Target node. Only allowed if the original VM is on shared storage.
 
@@ -56,11 +69,11 @@ Target node. Only allowed if the original VM is on shared storage.
 Get current virtual machine configuration. This does not include pending
 configuration changes (see 'pending' API).
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-current` `boolean` (default=`0`)::
+`-current` `<boolean>` ('default =' `0`)::
 
 Get current values (instead of pending values).
 
@@ -70,43 +83,39 @@ Get current values (instead of pending values).
 
 Create or restore a virtual machine.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-acpi` `boolean` (default=`1`)::
+`-acpi` `<boolean>` ('default =' `1`)::
 
 Enable/disable ACPI.
 
-`-agent` `boolean` (default=`0`)::
+`-agent` `<boolean>` ('default =' `0`)::
 
 Enable/disable Qemu GuestAgent.
 
-`-archive` `string` ::
+`-archive` `<string>` ::
 
 The backup file.
 
-`-args` `string` ::
+`-args` `<string>` ::
 
-NOTE: this option is for experts only. It allows you to pass arbitrary
-arguments to kvm, for example:
-+
-args: -no-reboot -no-hpet
+Arbitrary arguments passed to kvm.
 
-`-autostart` `boolean` (default=`0`)::
+`-autostart` `<boolean>` ('default =' `0`)::
 
 Automatic restart after crash (currently ignored).
 
-`-balloon` `integer (0 - N)` ::
+`-balloon` `<integer> (0 - N)` ::
 
-Amount of target RAM for the VM in MB. Using zero disables the ballon
-driver.
+Amount of target RAM for the VM in MB. Using zero disables the ballon driver.
 
-`-bios` `(ovmf | seabios)` (default=`seabios`)::
+`-bios` `<ovmf | seabios>` ('default =' `seabios`)::
 
 Select BIOS implementation.
 
-`-boot` `[acdn]{1,4}` (default=`cdn`)::
+`-boot` `[acdn]{1,4}` ('default =' `cdn`)::
 
 Boot on floppy (a), hard disk (c), CD-ROM (d), or network (n).
 
@@ -114,90 +123,73 @@ Boot on floppy (a), hard disk (c), CD-ROM (d), or network (n).
 
 Enable booting from specified disk.
 
-`-cdrom` `volume` ::
+`-cdrom` `<volume>` ::
 
 This is an alias for option -ide2
 
-`-cores` `integer (1 - N)` (default=`1`)::
+`-cores` `<integer> (1 - N)` ('default =' `1`)::
 
 The number of cores per socket.
 
-`-cpu` `[cputype=]<cputype> [,hidden=<1|0>]` ::
+`-cpu` `[cputype=]<enum> [,hidden=<1|0>]` ::
 
 Emulated CPU type.
 
-`-cpulimit` `number (0 - 128)` (default=`0`)::
+`-cpulimit` `<number> (0 - 128)` ('default =' `0`)::
 
 Limit of CPU usage.
-+
-NOTE: If the computer has 2 CPUs, it has total of '2' CPU time. Value '0'
-indicates no CPU limit.
 
-`-cpuunits` `integer (0 - 500000)` (default=`1000`)::
+`-cpuunits` `<integer> (0 - 500000)` ('default =' `1024`)::
 
-CPU weight for a VM. Argument is used in the kernel fair scheduler. The
-larger the number is, the more CPU time this VM gets. Number is relative to
-weights of all the other running VMs.
-+
-NOTE: You can disable fair-scheduler configuration by setting this to 0.
+CPU weight for a VM.
+
+`-description` `<string>` ::
 
-`-description` `string` ::
+Description for the VM. Only used on the configuration web interface. This is saved as comment inside the configuration file.
 
-Description for the VM. Only used on the configuration web interface. This
-is saved as comment inside the configuration file.
+`-efidisk0` `[file=]<volume> [,format=<enum>] [,size=<DiskSize>]` ::
 
-`-force` `boolean` ::
+Configure a Disk for storing EFI vars
+
+`-force` `<boolean>` ::
 
 Allow to overwrite existing VM.
 +
 NOTE: Requires option(s): `archive`
 
-`-freeze` `boolean` ::
+`-freeze` `<boolean>` ::
 
 Freeze CPU at startup (use 'c' monitor command to start execution).
 
-`-hostpci[n]` `[host=]<HOSTPCIID[;HOSTPCIID2...]> [,pcie=<1|0>] [,rombar=<1|0>] [,x-vga=<1|0>]` ::
+`-hostpci[n]` `[host=]<HOSTPCIID[;HOSTPCIID2...]> [,pcie=<1|0>] [,rombar=<1|0>] [,romfile=<string>] [,x-vga=<1|0>]` ::
 
-Map host pci devices. HOSTPCIDEVICE syntax is:
-+
-'bus:dev.func' (hexadecimal numbers)
-+
-You can us the 'lspci' command to list existing pci devices.
-+
-The 'rombar' option determines whether or not the device's ROM will be
-visible in the guest's memory map (default is 'on').
-+
-NOTE: This option allows direct access to host hardware. So it is no longer
-possible to migrate such machines - use with special care.
-+
-Experimental: user reported problems with this option.
+Map host PCI devices into guest.
 
-`-hotplug` `string` (default=`network,disk,usb`)::
+`-hotplug` `<string>` ('default =' `network,disk,usb`)::
 
-Selectively enable hotplug features. This is a comma separated list of
-hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to
-disable hotplug completely. Value '1' is an alias for the default
-'network,disk,usb'.
+Selectively enable hotplug features. This is a comma separated list of hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to disable hotplug completely. Value '1' is an alias for the default 'network,disk,usb'.
 
-`-ide[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<on|off>] [,bps=<bps>] [,bps_rd=<bps>] [,bps_wr=<bps>] [,cache=<none|writethrough|writeback|unsafe|directsync>] [,cyls=<count>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<drive format>] [,heads=<count>] [,iops=<iops>] [,iops_max=<iops>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,model=<model>] [,rerror=<ignore|report|stop>] [,secs=<count>] [,serial=<serial>] [,snapshot=<on|off>] [,trans=<none|lba|auto>] [,werror=<enospc|ignore|report|stop>]` ::
+`-hugepages` `<1024 | 2 | any>` ::
+
+Enable/disable hugepages memory.
+
+`-ide[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_length=<seconds>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_length=<seconds>] [,iops_wr_max=<iops>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,model=<model>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
 
 Use volume as IDE hard disk or CD-ROM (n is 0 to 3).
 
-`-keyboard` `(da | de | de-ch | en-gb | en-us | es | fi | fr | fr-be | fr-ca | fr-ch | hu | is | it | ja | lt | mk | nl | no | pl | pt | pt-br | sl | sv | tr)` (default=`en-us`)::
+`-keyboard` `<da | de | de-ch | en-gb | en-us | es | fi | fr | fr-be | fr-ca | fr-ch | hu | is | it | ja | lt | mk | nl | no | pl | pt | pt-br | sl | sv | tr>` ('default =' `en-us`)::
 
-Keybord layout for vnc server. Default is read from the datacenter
-configuration file.
+Keybord layout for vnc server. Default is read from the '/etc/pve/datacenter.conf' configuration file.
 
-`-kvm` `boolean` (default=`1`)::
+`-kvm` `<boolean>` ('default =' `1`)::
 
 Enable/disable KVM hardware virtualization.
 
-`-localtime` `boolean` ::
+`-localtime` `<boolean>` ::
 
-Set the real time clock to local time. This is enabled by default if ostype
-indicates a Microsoft OS.
+Set the real time clock to local time. This is enabled by default if ostype indicates a Microsoft OS.
 
-`-lock` `(backup | migrate | rollback | snapshot)` ::
+`-lock` `<backup | migrate | rollback | snapshot>` ::
 
 Lock/unlock the VM.
 
@@ -205,228 +197,143 @@ Lock/unlock the VM.
 
 Specific the Qemu machine type.
 
-`-memory` `integer (16 - N)` (default=`512`)::
+`-memory` `<integer> (16 - N)` ('default =' `512`)::
 
-Amount of RAM for the VM in MB. This is the maximum available memory when
-you use the balloon device.
+Amount of RAM for the VM in MB. This is the maximum available memory when you use the balloon device.
 
-`-migrate_downtime` `number (0 - N)` (default=`0.1`)::
+`-migrate_downtime` `<number> (0 - N)` ('default =' `0.1`)::
 
 Set maximum tolerated downtime (in seconds) for migrations.
 
-`-migrate_speed` `integer (0 - N)` (default=`0`)::
+`-migrate_speed` `<integer> (0 - N)` ('default =' `0`)::
 
 Set maximum speed (in MB/s) for migrations. Value 0 is no limit.
 
-`-name` `string` ::
+`-name` `<string>` ::
 
 Set a name for the VM. Only used on the configuration web interface.
 
-`-net[n]` `string` ::
+`-net[n]` `[model=]<enum> [,bridge=<bridge>] [,firewall=<1|0>] [,link_down=<1|0>] [,macaddr=<XX:XX:XX:XX:XX:XX>] [,queues=<integer>] [,rate=<number>] [,tag=<integer>] [,trunks=<vlanid[;vlanid...]>] [,<model>=<macaddr>]` ::
 
 Specify network devices.
-+
-MODEL is one of: e1000 e1000-82540em e1000-82544gc e1000-82545em i82551
-i82557b i82559er ne2k_isa ne2k_pci pcnet rtl8139 virtio vmxnet3
-+
-XX:XX:XX:XX:XX:XX should be an unique MAC address. This is
-automatically generated if not specified.
-+
-The bridge parameter can be used to automatically add the interface to a
-bridge device. The Proxmox VE standard bridge is called 'vmbr0'.
-+
-Option 'rate' is used to limit traffic bandwidth from and to this
-interface. It is specified as floating point number, unit is 'Megabytes per
-second'.
-+
-If you specify no bridge, we create a kvm 'user' (NATed) network device,
-which provides DHCP and DNS services. The following addresses are used:
-+
-10.0.2.2   Gateway
-10.0.2.3   DNS Server
-10.0.2.4   SMB Server
-+
-The DHCP server assign addresses to the guest starting from 10.0.2.15.
 
-`-numa` `boolean` (default=`0`)::
+`-numa` `<boolean>` ('default =' `0`)::
 
 Enable/disable NUMA.
 
-`-numa[n]` `cpus=<id[-id];...> [,hostnodes=<id[-id];...>] [,memory=<mb>] [,policy=<preferred|bind|interleave>]` ::
+`-numa[n]` `cpus=<id[-id];...> [,hostnodes=<id[-id];...>] [,memory=<number>] [,policy=<preferred|bind|interleave>]` ::
 
-numa topology
+NUMA topology.
 
-`-onboot` `boolean` (default=`0`)::
+`-onboot` `<boolean>` ('default =' `0`)::
 
 Specifies whether a VM will be started during system bootup.
 
-`-ostype` `(l24 | l26 | other | solaris | w2k | w2k3 | w2k8 | win7 | win8 | wvista | wxp)` ::
+`-ostype` `<l24 | l26 | other | solaris | w2k | w2k3 | w2k8 | win10 | win7 | win8 | wvista | wxp>` ::
 
-Used to enable special optimization/features for specific
-operating systems:
-+
-other  => unspecified OS
-wxp    => Microsoft Windows XP
-w2k    => Microsoft Windows 2000
-w2k3   => Microsoft Windows 2003
-w2k8   => Microsoft Windows 2008
-wvista => Microsoft Windows Vista
-win7   => Microsoft Windows 7
-win8   => Microsoft Windows 8/2012
-l24    => Linux 2.4 Kernel
-l26    => Linux 2.6/3.X Kernel
-solaris => solaris/opensolaris/openindiania kernel
-+
-other|l24|l26|solaris                      ... no special behaviour
-wxp|w2k|w2k3|w2k8|wvista|win7|win8  ... use --localtime switch
+Specify guest operating system.
 
 `-parallel[n]` `/dev/parport\d+|/dev/usb/lp\d+` ::
 
 Map host parallel devices (n is 0 to 2).
-+
-NOTE: This option allows direct access to host hardware. So it is no longer
-possible to migrate such machines - use with special care.
-+
-Experimental: user reported problems with this option.
 
-`-pool` `string` ::
+`-pool` `<string>` ::
 
 Add the VM to the specified pool.
 
-`-protection` `boolean` (default=`0`)::
+`-protection` `<boolean>` ('default =' `0`)::
 
-Sets the protection flag of the VM. This will prevent the remove operation.
+Sets the protection flag of the VM. This will disable the remove VM and remove disk operations.
 
-`-reboot` `boolean` (default=`1`)::
+`-reboot` `<boolean>` ('default =' `1`)::
 
 Allow reboot. If set to '0' the VM exit on reboot.
 
-`-sata[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<on|off>] [,bps=<bps>] [,bps_rd=<bps>] [,bps_wr=<bps>] [,cache=<none|writethrough|writeback|unsafe|directsync>] [,cyls=<count>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<drive format>] [,heads=<count>] [,iops=<iops>] [,iops_max=<iops>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,rerror=<ignore|report|stop>] [,secs=<count>] [,serial=<serial>] [,snapshot=<on|off>] [,trans=<none|lba|auto>] [,werror=<enospc|ignore|report|stop>]` ::
+`-sata[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_length=<seconds>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_length=<seconds>] [,iops_wr_max=<iops>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
 
 Use volume as SATA hard disk or CD-ROM (n is 0 to 5).
 
-`-scsi[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<on|off>] [,bps=<bps>] [,bps_rd=<bps>] [,bps_wr=<bps>] [,cache=<none|writethrough|writeback|unsafe|directsync>] [,cyls=<count>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<drive format>] [,heads=<count>] [,iops=<iops>] [,iops_max=<iops>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iothread=<off|on>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,queues=<nbqueues>] [,secs=<count>] [,serial=<serial>] [,snapshot=<on|off>] [,trans=<none|lba|auto>] [,werror=<enospc|ignore|report|stop>]` ::
+`-scsi[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_length=<seconds>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_length=<seconds>] [,iops_wr_max=<iops>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,queues=<integer>] [,scsiblock=<1|0>] [,secs=<integer>] [,serial=<serial>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
 
 Use volume as SCSI hard disk or CD-ROM (n is 0 to 13).
 
-`-scsihw` `(lsi | lsi53c810 | megasas | pvscsi | virtio-scsi-pci | virtio-scsi-single)` (default=`lsi`)::
+`-scsihw` `<lsi | lsi53c810 | megasas | pvscsi | virtio-scsi-pci | virtio-scsi-single>` ('default =' `lsi`)::
 
-scsi controller model
+SCSI controller model
 
 `-serial[n]` `(/dev/.+|socket)` ::
 
-Create a serial device inside the VM (n is 0 to 3), and pass through a host
-serial device (i.e. /dev/ttyS0), or create a unix socket on the host side
-(use 'qm terminal' to open a terminal connection).
-+
-NOTE: If you pass through a host serial device, it is no longer possible to
-migrate such machines - use with special care.
-+
-Experimental: user reported problems with this option.
+Create a serial device inside the VM (n is 0 to 3)
 
-`-shares` `integer (0 - 50000)` (default=`1000`)::
+`-shares` `<integer> (0 - 50000)` ('default =' `1000`)::
 
-Amount of memory shares for auto-ballooning. The larger the number is, the
-more memory this VM gets. Number is relative to weights of all other
-running VMs. Using zero disables auto-ballooning
+Amount of memory shares for auto-ballooning. The larger the number is, the more memory this VM gets. Number is relative to weights of all other running VMs. Using zero disables auto-ballooning
 
-`-smbios[n]` `[family=<str>] [,manufacturer=<name>] [,product=<name>] [,serial=<str>] [,sku=<str>] [,uuid=<UUID>] [,version=<str>]` ::
+`-smbios1` `[family=<string>] [,manufacturer=<string>] [,product=<string>] [,serial=<string>] [,sku=<string>] [,uuid=<UUID>] [,version=<string>]` ::
 
 Specify SMBIOS type 1 fields.
 
-`-smp` `integer (1 - N)` (default=`1`)::
+`-smp` `<integer> (1 - N)` ('default =' `1`)::
 
 The number of CPUs. Please use option -sockets instead.
 
-`-sockets` `integer (1 - N)` (default=`1`)::
+`-sockets` `<integer> (1 - N)` ('default =' `1`)::
 
 The number of CPU sockets.
 
-`-startdate` `(now | YYYY-MM-DD | YYYY-MM-DDTHH:MM:SS)` (default=`now`)::
+`-startdate` `(now | YYYY-MM-DD | YYYY-MM-DDTHH:MM:SS)` ('default =' `now`)::
 
-Set the initial date of the real time clock. Valid format for date are:
-'now' or '2006-06-17T16:01:21' or '2006-06-17'.
+Set the initial date of the real time clock. Valid format for date are: 'now' or '2006-06-17T16:01:21' or '2006-06-17'.
 
 `-startup` `[[order=]\d+] [,up=\d+] [,down=\d+] ` ::
 
-Startup and shutdown behavior. Order is a non-negative number defining the
-general startup order. Shutdown in done with reverse ordering. Additionally
-you can set the 'up' or 'down' delay in seconds, which specifies a delay to
-wait before the next VM is started or stopped.
+Startup and shutdown behavior. Order is a non-negative number defining the general startup order. Shutdown in done with reverse ordering. Additionally you can set the 'up' or 'down' delay in seconds, which specifies a delay to wait before the next VM is started or stopped.
 
-`-storage` `string` ::
+`-storage` `<string>` ::
 
 Default storage.
 
-`-tablet` `boolean` (default=`1`)::
+`-tablet` `<boolean>` ('default =' `1`)::
 
-Enable/disable the USB tablet device. This device is usually needed to
-allow absolute mouse positioning with VNC. Else the mouse runs out of sync
-with normal VNC clients. If you're running lots of console-only guests on
-one host, you may consider disabling this to save some context switches.
-This is turned off by default if you use spice (-vga=qxl).
+Enable/disable the USB tablet device.
 
-`-tdf` `boolean` (default=`0`)::
+`-tdf` `<boolean>` ('default =' `0`)::
 
 Enable/disable time drift fix.
 
-`-template` `boolean` (default=`0`)::
+`-template` `<boolean>` ('default =' `0`)::
 
 Enable/disable Template.
 
-`-unique` `boolean` ::
+`-unique` `<boolean>` ::
 
 Assign a unique random ethernet address.
 +
 NOTE: Requires option(s): `archive`
 
-`-unused[n]` `string` ::
+`-unused[n]` `<string>` ::
 
-Reference to unused volumes.
+Reference to unused volumes. This is used internally, and should not be modified manually.
 
-`-usb[n]` `[host=]<HOSTUSBDEVICE|spice> [,usb3=<yes|no>]` ::
+`-usb[n]` `[host=]<HOSTUSBDEVICE|spice> [,usb3=<1|0>]` ::
 
-Configure an USB device (n is 0 to 4). This can be used to
-pass-through usb devices to the guest. HOSTUSBDEVICE syntax is:
-+
-'bus-port(.port)*' (decimal numbers) or
-'vendor_id:product_id' (hexadeciaml numbers) or
-'spice'
-+
-You can use the 'lsusb -t' command to list existing usb devices.
-+
-NOTE: This option allows direct access to host hardware. So it is no longer
-possible to migrate such machines - use with special care.
-+
-The value 'spice' can be used to add a usb redirection devices for spice.
-+
-The 'usb3' option determines whether the device is a USB3 device or not
-(this does currently not work reliably with spice redirection and is then
-ignored).
+Configure an USB device (n is 0 to 4).
 
-`-vcpus` `integer (1 - N)` (default=`0`)::
+`-vcpus` `<integer> (1 - N)` ('default =' `0`)::
 
 Number of hotplugged vcpus.
 
-`-vga` `(cirrus | qxl | qxl2 | qxl3 | qxl4 | serial0 | serial1 | serial2 | serial3 | std | vmware)` ::
+`-vga` `<cirrus | qxl | qxl2 | qxl3 | qxl4 | serial0 | serial1 | serial2 | serial3 | std | vmware>` ::
 
-Select the VGA type. If you want to use high resolution modes (>=
-1280x1024x16) then you should use the options 'std' or 'vmware'. Default is
-'std' for win8/win7/w2k8, and 'cirrus' for other OS types. The 'qxl' option
-enables the SPICE display sever. For win* OS you can select how many
-independent displays you want, Linux guests can add displays them self. You
-can also run without any graphic card, using a serial device as terminal.
+Select the VGA type.
 
-`-virtio[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<on|off>] [,bps=<bps>] [,bps_rd=<bps>] [,bps_wr=<bps>] [,cache=<none|writethrough|writeback|unsafe|directsync>] [,cyls=<count>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<drive format>] [,heads=<count>] [,iops=<iops>] [,iops_max=<iops>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iothread=<off|on>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,rerror=<ignore|report|stop>] [,secs=<count>] [,serial=<serial>] [,snapshot=<on|off>] [,trans=<none|lba|auto>] [,werror=<enospc|ignore|report|stop>]` ::
+`-virtio[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_length=<seconds>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_length=<seconds>] [,iops_wr_max=<iops>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
 
 Use volume as VIRTIO hard disk (n is 0 to 15).
 
-`-watchdog` `[action=<reset|shutdown|poweroff|pause|debug|none>] [,[model=]<i6300esb|ib700>]` ::
+`-watchdog` `[[model=]<i6300esb|ib700>] [,action=<enum>]` ::
 
-Create a virtual hardware watchdog device. Once enabled (by a guest
-action), the watchdog must be periodically polled by an agent inside the
-guest or else the watchdog will reset the guest (or execute the respective
-action specified)
+Create a virtual hardware watchdog device.
 
 
 
@@ -434,15 +341,15 @@ action specified)
 
 Delete a VM snapshot.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`<snapname>` `string` ::
+`<snapname>`: `<string>` ::
 
 The name of the snapshot.
 
-`-force` `boolean` ::
+`-force` `<boolean>` ::
 
 For removal from config file, even if removing disk snapshots fails.
 
@@ -452,11 +359,11 @@ For removal from config file, even if removing disk snapshots fails.
 
 Destroy the vm (also delete all used/owned volumes).
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-skiplock` `boolean` ::
+`-skiplock` `<boolean>` ::
 
 Ignore locks - only root is allowed to use this option.
 
@@ -467,11 +374,11 @@ Ignore locks - only root is allowed to use this option.
 
 Get help about specified command.
 
-`<cmd>` `string` ::
+`<cmd>`: `<string>` ::
 
 Command name
 
-`-verbose` `boolean` ::
+`-verbose` `<boolean>` ::
 
 Verbose output format.
 
@@ -482,33 +389,58 @@ Verbose output format.
 
 Virtual machine index (per node).
 
-`-full` `boolean` ::
+`-full` `<boolean>` ::
 
 Determine the full status of active VMs.
 
 
 
+*qm listsnapshot* `<vmid>`
+
+List all snapshots.
+
+`<vmid>`: `<integer> (1 - N)` ::
+
+The (unique) ID of the VM.
+
+
+
 *qm migrate* `<vmid> <target>` `[OPTIONS]`
 
 Migrate virtual machine. Creates a new migration task.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`<target>` `string` ::
+`<target>`: `<string>` ::
 
 Target node.
 
-`-force` `boolean` ::
+`-force` `<boolean>` ::
+
+Allow to migrate VMs which use local devices. Only root may use this option.
+
+`-migration_network` `<string>` ::
+
+CIDR of the (sub) network that is used for migration.
 
-Allow to migrate VMs which use local devices. Only root may use this
-option.
+`-migration_type` `<insecure | secure>` ::
 
-`-online` `boolean` ::
+Migration traffic is encrypted using an SSH tunnel by default. On secure, completely private networks this can be disabled to increase performance.
+
+`-online` `<boolean>` ::
 
 Use online/live migration.
 
+`-targetstorage` `<string>` ::
+
+Default target storage.
+
+`-with-local-disks` `<boolean>` ::
+
+Enable live storage migration for local disk
+
 
 
 
@@ -516,7 +448,7 @@ Use online/live migration.
 
 Enter Qemu Monitor interface.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
@@ -527,29 +459,27 @@ The (unique) ID of the VM.
 
 Move volume to different storage.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`<disk>` `(ide0 | ide1 | ide2 | ide3 | sata0 | sata1 | sata2 | sata3 | sata4 | sata5 | scsi0 | scsi1 | scsi10 | scsi11 | scsi12 | scsi13 | scsi2 | scsi3 | scsi4 | scsi5 | scsi6 | scsi7 | scsi8 | scsi9 | virtio0 | virtio1 | virtio10 | virtio11 | virtio12 | virtio13 | virtio14 | virtio15 | virtio2 | virtio3 | virtio4 | virtio5 | virtio6 | virtio7 | virtio8 | virtio9)` ::
+`<disk>`: `<efidisk0 | ide0 | ide1 | ide2 | ide3 | sata0 | sata1 | sata2 | sata3 | sata4 | sata5 | scsi0 | scsi1 | scsi10 | scsi11 | scsi12 | scsi13 | scsi2 | scsi3 | scsi4 | scsi5 | scsi6 | scsi7 | scsi8 | scsi9 | virtio0 | virtio1 | virtio10 | virtio11 | virtio12 | virtio13 | virtio14 | virtio15 | virtio2 | virtio3 | virtio4 | virtio5 | virtio6 | virtio7 | virtio8 | virtio9>` ::
 
 The disk you want to move.
 
-`<storage>` `string` ::
+`<storage>`: `<string>` ::
 
 Target storage.
 
-`-delete` `boolean` (default=`0`)::
+`-delete` `<boolean>` ('default =' `0`)::
 
-Delete the original disk after successful copy. By default the original
-disk is kept as unused disk.
+Delete the original disk after successful copy. By default the original disk is kept as unused disk.
 
-`-digest` `string` ::
+`-digest` `<string>` ::
 
-Prevent changes if current configuration file has different SHA1 digest.
-This can be used to prevent concurrent modifications.
+Prevent changes if current configuration file has different SHA1 digest. This can be used to prevent concurrent modifications.
 
-`-format` `(qcow2 | raw | vmdk)` ::
+`-format` `<qcow2 | raw | vmdk>` ::
 
 Target Format.
 
@@ -562,12 +492,22 @@ Used by qmigrate - do not use manually.
 
 
 
+*qm nbdstop* `<vmid>`
+
+Stop embedded nbd server.
+
+`<vmid>`: `<integer> (1 - N)` ::
+
+The (unique) ID of the VM.
+
+
+
 
 *qm pending* `<vmid>`
 
 Get virtual machine configuration, including pending changes.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
@@ -578,7 +518,7 @@ The (unique) ID of the VM.
 
 Rescan all storages and update disk sizes and unused disk images.
 
-`-vmid` `integer (1 - N)` ::
+`-vmid` `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
@@ -589,11 +529,11 @@ The (unique) ID of the VM.
 
 Reset virtual machine.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-skiplock` `boolean` ::
+`-skiplock` `<boolean>` ::
 
 Ignore locks - only root is allowed to use this option.
 
@@ -603,26 +543,23 @@ Ignore locks - only root is allowed to use this option.
 
 Extend volume size.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`<disk>` `(ide0 | ide1 | ide2 | ide3 | sata0 | sata1 | sata2 | sata3 | sata4 | sata5 | scsi0 | scsi1 | scsi10 | scsi11 | scsi12 | scsi13 | scsi2 | scsi3 | scsi4 | scsi5 | scsi6 | scsi7 | scsi8 | scsi9 | virtio0 | virtio1 | virtio10 | virtio11 | virtio12 | virtio13 | virtio14 | virtio15 | virtio2 | virtio3 | virtio4 | virtio5 | virtio6 | virtio7 | virtio8 | virtio9)` ::
+`<disk>`: `<efidisk0 | ide0 | ide1 | ide2 | ide3 | sata0 | sata1 | sata2 | sata3 | sata4 | sata5 | scsi0 | scsi1 | scsi10 | scsi11 | scsi12 | scsi13 | scsi2 | scsi3 | scsi4 | scsi5 | scsi6 | scsi7 | scsi8 | scsi9 | virtio0 | virtio1 | virtio10 | virtio11 | virtio12 | virtio13 | virtio14 | virtio15 | virtio2 | virtio3 | virtio4 | virtio5 | virtio6 | virtio7 | virtio8 | virtio9>` ::
 
 The disk you want to resize.
 
-`<size>` `\+?\d+(\.\d+)?[KMGT]?` ::
+`<size>`: `\+?\d+(\.\d+)?[KMGT]?` ::
 
-The new size. With the '+' sign the value is added to the actual size of
-the volume and without it, the value is taken as an absolute one. Shrinking
-disk size is not supported.
+The new size. With the '+' sign the value is added to the actual size of the volume and without it, the value is taken as an absolute one. Shrinking disk size is not supported.
 
-`-digest` `string` ::
+`-digest` `<string>` ::
 
-Prevent changes if current configuration file has different SHA1 digest.
-This can be used to prevent concurrent modifications.
+Prevent changes if current configuration file has different SHA1 digest. This can be used to prevent concurrent modifications.
 
-`-skiplock` `boolean` ::
+`-skiplock` `<boolean>` ::
 
 Ignore locks - only root is allowed to use this option.
 
@@ -632,15 +569,15 @@ Ignore locks - only root is allowed to use this option.
 
 Resume virtual machine.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-nocheck` `boolean` ::
+`-nocheck` `<boolean>` ::
 
 no description available
 
-`-skiplock` `boolean` ::
+`-skiplock` `<boolean>` ::
 
 Ignore locks - only root is allowed to use this option.
 
@@ -650,11 +587,11 @@ Ignore locks - only root is allowed to use this option.
 
 Rollback VM state to specified snapshot.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`<snapname>` `string` ::
+`<snapname>`: `<string>` ::
 
 The name of the snapshot.
 
@@ -664,15 +601,15 @@ The name of the snapshot.
 
 Send key event to virtual machine.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`<key>` `string` ::
+`<key>`: `<string>` ::
 
 The key (qemu monitor encoding).
 
-`-skiplock` `boolean` ::
+`-skiplock` `<boolean>` ::
 
 Ignore locks - only root is allowed to use this option.
 
@@ -684,39 +621,35 @@ Set virtual machine options (synchrounous API) - You should consider using
 the POST method instead for any actions involving hotplug or storage
 allocation.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-acpi` `boolean` (default=`1`)::
+`-acpi` `<boolean>` ('default =' `1`)::
 
 Enable/disable ACPI.
 
-`-agent` `boolean` (default=`0`)::
+`-agent` `<boolean>` ('default =' `0`)::
 
 Enable/disable Qemu GuestAgent.
 
-`-args` `string` ::
+`-args` `<string>` ::
 
-NOTE: this option is for experts only. It allows you to pass arbitrary
-arguments to kvm, for example:
-+
-args: -no-reboot -no-hpet
+Arbitrary arguments passed to kvm.
 
-`-autostart` `boolean` (default=`0`)::
+`-autostart` `<boolean>` ('default =' `0`)::
 
 Automatic restart after crash (currently ignored).
 
-`-balloon` `integer (0 - N)` ::
+`-balloon` `<integer> (0 - N)` ::
 
-Amount of target RAM for the VM in MB. Using zero disables the ballon
-driver.
+Amount of target RAM for the VM in MB. Using zero disables the ballon driver.
 
-`-bios` `(ovmf | seabios)` (default=`seabios`)::
+`-bios` `<ovmf | seabios>` ('default =' `seabios`)::
 
 Select BIOS implementation.
 
-`-boot` `[acdn]{1,4}` (default=`cdn`)::
+`-boot` `[acdn]{1,4}` ('default =' `cdn`)::
 
 Boot on floppy (a), hard disk (c), CD-ROM (d), or network (n).
 
@@ -724,102 +657,81 @@ Boot on floppy (a), hard disk (c), CD-ROM (d), or network (n).
 
 Enable booting from specified disk.
 
-`-cdrom` `volume` ::
+`-cdrom` `<volume>` ::
 
 This is an alias for option -ide2
 
-`-cores` `integer (1 - N)` (default=`1`)::
+`-cores` `<integer> (1 - N)` ('default =' `1`)::
 
 The number of cores per socket.
 
-`-cpu` `[cputype=]<cputype> [,hidden=<1|0>]` ::
+`-cpu` `[cputype=]<enum> [,hidden=<1|0>]` ::
 
 Emulated CPU type.
 
-`-cpulimit` `number (0 - 128)` (default=`0`)::
+`-cpulimit` `<number> (0 - 128)` ('default =' `0`)::
 
 Limit of CPU usage.
-+
-NOTE: If the computer has 2 CPUs, it has total of '2' CPU time. Value '0'
-indicates no CPU limit.
 
-`-cpuunits` `integer (0 - 500000)` (default=`1000`)::
+`-cpuunits` `<integer> (0 - 500000)` ('default =' `1024`)::
 
-CPU weight for a VM. Argument is used in the kernel fair scheduler. The
-larger the number is, the more CPU time this VM gets. Number is relative to
-weights of all the other running VMs.
-+
-NOTE: You can disable fair-scheduler configuration by setting this to 0.
+CPU weight for a VM.
 
-`-delete` `string` ::
+`-delete` `<string>` ::
 
 A list of settings you want to delete.
 
-`-description` `string` ::
+`-description` `<string>` ::
 
-Description for the VM. Only used on the configuration web interface. This
-is saved as comment inside the configuration file.
+Description for the VM. Only used on the configuration web interface. This is saved as comment inside the configuration file.
 
-`-digest` `string` ::
+`-digest` `<string>` ::
 
-Prevent changes if current configuration file has different SHA1 digest.
-This can be used to prevent concurrent modifications.
+Prevent changes if current configuration file has different SHA1 digest. This can be used to prevent concurrent modifications.
 
-`-force` `boolean` ::
+`-efidisk0` `[file=]<volume> [,format=<enum>] [,size=<DiskSize>]` ::
 
-Force physical removal. Without this, we simple remove the disk from the
-config file and create an additional configuration entry called
-'unused[n]', which contains the volume ID. Unlink of unused[n] always cause
-physical removal.
+Configure a Disk for storing EFI vars
+
+`-force` `<boolean>` ::
+
+Force physical removal. Without this, we simple remove the disk from the config file and create an additional configuration entry called 'unused[n]', which contains the volume ID. Unlink of unused[n] always cause physical removal.
 +
 NOTE: Requires option(s): `delete`
 
-`-freeze` `boolean` ::
+`-freeze` `<boolean>` ::
 
 Freeze CPU at startup (use 'c' monitor command to start execution).
 
-`-hostpci[n]` `[host=]<HOSTPCIID[;HOSTPCIID2...]> [,pcie=<1|0>] [,rombar=<1|0>] [,x-vga=<1|0>]` ::
+`-hostpci[n]` `[host=]<HOSTPCIID[;HOSTPCIID2...]> [,pcie=<1|0>] [,rombar=<1|0>] [,romfile=<string>] [,x-vga=<1|0>]` ::
 
-Map host pci devices. HOSTPCIDEVICE syntax is:
-+
-'bus:dev.func' (hexadecimal numbers)
-+
-You can us the 'lspci' command to list existing pci devices.
-+
-The 'rombar' option determines whether or not the device's ROM will be
-visible in the guest's memory map (default is 'on').
-+
-NOTE: This option allows direct access to host hardware. So it is no longer
-possible to migrate such machines - use with special care.
-+
-Experimental: user reported problems with this option.
+Map host PCI devices into guest.
+
+`-hotplug` `<string>` ('default =' `network,disk,usb`)::
+
+Selectively enable hotplug features. This is a comma separated list of hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to disable hotplug completely. Value '1' is an alias for the default 'network,disk,usb'.
 
-`-hotplug` `string` (default=`network,disk,usb`)::
+`-hugepages` `<1024 | 2 | any>` ::
 
-Selectively enable hotplug features. This is a comma separated list of
-hotplug features: 'network', 'disk', 'cpu', 'memory' and 'usb'. Use '0' to
-disable hotplug completely. Value '1' is an alias for the default
-'network,disk,usb'.
+Enable/disable hugepages memory.
 
-`-ide[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<on|off>] [,bps=<bps>] [,bps_rd=<bps>] [,bps_wr=<bps>] [,cache=<none|writethrough|writeback|unsafe|directsync>] [,cyls=<count>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<drive format>] [,heads=<count>] [,iops=<iops>] [,iops_max=<iops>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,model=<model>] [,rerror=<ignore|report|stop>] [,secs=<count>] [,serial=<serial>] [,snapshot=<on|off>] [,trans=<none|lba|auto>] [,werror=<enospc|ignore|report|stop>]` ::
+`-ide[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_length=<seconds>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_length=<seconds>] [,iops_wr_max=<iops>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,model=<model>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
 
 Use volume as IDE hard disk or CD-ROM (n is 0 to 3).
 
-`-keyboard` `(da | de | de-ch | en-gb | en-us | es | fi | fr | fr-be | fr-ca | fr-ch | hu | is | it | ja | lt | mk | nl | no | pl | pt | pt-br | sl | sv | tr)` (default=`en-us`)::
+`-keyboard` `<da | de | de-ch | en-gb | en-us | es | fi | fr | fr-be | fr-ca | fr-ch | hu | is | it | ja | lt | mk | nl | no | pl | pt | pt-br | sl | sv | tr>` ('default =' `en-us`)::
 
-Keybord layout for vnc server. Default is read from the datacenter
-configuration file.
+Keybord layout for vnc server. Default is read from the '/etc/pve/datacenter.conf' configuration file.
 
-`-kvm` `boolean` (default=`1`)::
+`-kvm` `<boolean>` ('default =' `1`)::
 
 Enable/disable KVM hardware virtualization.
 
-`-localtime` `boolean` ::
+`-localtime` `<boolean>` ::
 
-Set the real time clock to local time. This is enabled by default if ostype
-indicates a Microsoft OS.
+Set the real time clock to local time. This is enabled by default if ostype indicates a Microsoft OS.
 
-`-lock` `(backup | migrate | rollback | snapshot)` ::
+`-lock` `<backup | migrate | rollback | snapshot>` ::
 
 Lock/unlock the VM.
 
@@ -827,222 +739,137 @@ Lock/unlock the VM.
 
 Specific the Qemu machine type.
 
-`-memory` `integer (16 - N)` (default=`512`)::
+`-memory` `<integer> (16 - N)` ('default =' `512`)::
 
-Amount of RAM for the VM in MB. This is the maximum available memory when
-you use the balloon device.
+Amount of RAM for the VM in MB. This is the maximum available memory when you use the balloon device.
 
-`-migrate_downtime` `number (0 - N)` (default=`0.1`)::
+`-migrate_downtime` `<number> (0 - N)` ('default =' `0.1`)::
 
 Set maximum tolerated downtime (in seconds) for migrations.
 
-`-migrate_speed` `integer (0 - N)` (default=`0`)::
+`-migrate_speed` `<integer> (0 - N)` ('default =' `0`)::
 
 Set maximum speed (in MB/s) for migrations. Value 0 is no limit.
 
-`-name` `string` ::
+`-name` `<string>` ::
 
 Set a name for the VM. Only used on the configuration web interface.
 
-`-net[n]` `string` ::
+`-net[n]` `[model=]<enum> [,bridge=<bridge>] [,firewall=<1|0>] [,link_down=<1|0>] [,macaddr=<XX:XX:XX:XX:XX:XX>] [,queues=<integer>] [,rate=<number>] [,tag=<integer>] [,trunks=<vlanid[;vlanid...]>] [,<model>=<macaddr>]` ::
 
 Specify network devices.
-+
-MODEL is one of: e1000 e1000-82540em e1000-82544gc e1000-82545em i82551
-i82557b i82559er ne2k_isa ne2k_pci pcnet rtl8139 virtio vmxnet3
-+
-XX:XX:XX:XX:XX:XX should be an unique MAC address. This is
-automatically generated if not specified.
-+
-The bridge parameter can be used to automatically add the interface to a
-bridge device. The Proxmox VE standard bridge is called 'vmbr0'.
-+
-Option 'rate' is used to limit traffic bandwidth from and to this
-interface. It is specified as floating point number, unit is 'Megabytes per
-second'.
-+
-If you specify no bridge, we create a kvm 'user' (NATed) network device,
-which provides DHCP and DNS services. The following addresses are used:
-+
-10.0.2.2   Gateway
-10.0.2.3   DNS Server
-10.0.2.4   SMB Server
-+
-The DHCP server assign addresses to the guest starting from 10.0.2.15.
 
-`-numa` `boolean` (default=`0`)::
+`-numa` `<boolean>` ('default =' `0`)::
 
 Enable/disable NUMA.
 
-`-numa[n]` `cpus=<id[-id];...> [,hostnodes=<id[-id];...>] [,memory=<mb>] [,policy=<preferred|bind|interleave>]` ::
+`-numa[n]` `cpus=<id[-id];...> [,hostnodes=<id[-id];...>] [,memory=<number>] [,policy=<preferred|bind|interleave>]` ::
 
-numa topology
+NUMA topology.
 
-`-onboot` `boolean` (default=`0`)::
+`-onboot` `<boolean>` ('default =' `0`)::
 
 Specifies whether a VM will be started during system bootup.
 
-`-ostype` `(l24 | l26 | other | solaris | w2k | w2k3 | w2k8 | win7 | win8 | wvista | wxp)` ::
+`-ostype` `<l24 | l26 | other | solaris | w2k | w2k3 | w2k8 | win10 | win7 | win8 | wvista | wxp>` ::
 
-Used to enable special optimization/features for specific
-operating systems:
-+
-other  => unspecified OS
-wxp    => Microsoft Windows XP
-w2k    => Microsoft Windows 2000
-w2k3   => Microsoft Windows 2003
-w2k8   => Microsoft Windows 2008
-wvista => Microsoft Windows Vista
-win7   => Microsoft Windows 7
-win8   => Microsoft Windows 8/2012
-l24    => Linux 2.4 Kernel
-l26    => Linux 2.6/3.X Kernel
-solaris => solaris/opensolaris/openindiania kernel
-+
-other|l24|l26|solaris                      ... no special behaviour
-wxp|w2k|w2k3|w2k8|wvista|win7|win8  ... use --localtime switch
+Specify guest operating system.
 
 `-parallel[n]` `/dev/parport\d+|/dev/usb/lp\d+` ::
 
 Map host parallel devices (n is 0 to 2).
-+
-NOTE: This option allows direct access to host hardware. So it is no longer
-possible to migrate such machines - use with special care.
-+
-Experimental: user reported problems with this option.
 
-`-protection` `boolean` (default=`0`)::
+`-protection` `<boolean>` ('default =' `0`)::
 
-Sets the protection flag of the VM. This will prevent the remove operation.
+Sets the protection flag of the VM. This will disable the remove VM and remove disk operations.
 
-`-reboot` `boolean` (default=`1`)::
+`-reboot` `<boolean>` ('default =' `1`)::
 
 Allow reboot. If set to '0' the VM exit on reboot.
 
-`-revert` `string` ::
+`-revert` `<string>` ::
 
 Revert a pending change.
 
-`-sata[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<on|off>] [,bps=<bps>] [,bps_rd=<bps>] [,bps_wr=<bps>] [,cache=<none|writethrough|writeback|unsafe|directsync>] [,cyls=<count>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<drive format>] [,heads=<count>] [,iops=<iops>] [,iops_max=<iops>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,rerror=<ignore|report|stop>] [,secs=<count>] [,serial=<serial>] [,snapshot=<on|off>] [,trans=<none|lba|auto>] [,werror=<enospc|ignore|report|stop>]` ::
+`-sata[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_length=<seconds>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_length=<seconds>] [,iops_wr_max=<iops>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
 
 Use volume as SATA hard disk or CD-ROM (n is 0 to 5).
 
-`-scsi[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<on|off>] [,bps=<bps>] [,bps_rd=<bps>] [,bps_wr=<bps>] [,cache=<none|writethrough|writeback|unsafe|directsync>] [,cyls=<count>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<drive format>] [,heads=<count>] [,iops=<iops>] [,iops_max=<iops>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iothread=<off|on>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,queues=<nbqueues>] [,secs=<count>] [,serial=<serial>] [,snapshot=<on|off>] [,trans=<none|lba|auto>] [,werror=<enospc|ignore|report|stop>]` ::
+`-scsi[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_length=<seconds>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_length=<seconds>] [,iops_wr_max=<iops>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,queues=<integer>] [,scsiblock=<1|0>] [,secs=<integer>] [,serial=<serial>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
 
 Use volume as SCSI hard disk or CD-ROM (n is 0 to 13).
 
-`-scsihw` `(lsi | lsi53c810 | megasas | pvscsi | virtio-scsi-pci | virtio-scsi-single)` (default=`lsi`)::
+`-scsihw` `<lsi | lsi53c810 | megasas | pvscsi | virtio-scsi-pci | virtio-scsi-single>` ('default =' `lsi`)::
 
-scsi controller model
+SCSI controller model
 
 `-serial[n]` `(/dev/.+|socket)` ::
 
-Create a serial device inside the VM (n is 0 to 3), and pass through a host
-serial device (i.e. /dev/ttyS0), or create a unix socket on the host side
-(use 'qm terminal' to open a terminal connection).
-+
-NOTE: If you pass through a host serial device, it is no longer possible to
-migrate such machines - use with special care.
-+
-Experimental: user reported problems with this option.
+Create a serial device inside the VM (n is 0 to 3)
 
-`-shares` `integer (0 - 50000)` (default=`1000`)::
+`-shares` `<integer> (0 - 50000)` ('default =' `1000`)::
 
-Amount of memory shares for auto-ballooning. The larger the number is, the
-more memory this VM gets. Number is relative to weights of all other
-running VMs. Using zero disables auto-ballooning
+Amount of memory shares for auto-ballooning. The larger the number is, the more memory this VM gets. Number is relative to weights of all other running VMs. Using zero disables auto-ballooning
 
-`-skiplock` `boolean` ::
+`-skiplock` `<boolean>` ::
 
 Ignore locks - only root is allowed to use this option.
 
-`-smbios[n]` `[family=<str>] [,manufacturer=<name>] [,product=<name>] [,serial=<str>] [,sku=<str>] [,uuid=<UUID>] [,version=<str>]` ::
+`-smbios1` `[family=<string>] [,manufacturer=<string>] [,product=<string>] [,serial=<string>] [,sku=<string>] [,uuid=<UUID>] [,version=<string>]` ::
 
 Specify SMBIOS type 1 fields.
 
-`-smp` `integer (1 - N)` (default=`1`)::
+`-smp` `<integer> (1 - N)` ('default =' `1`)::
 
 The number of CPUs. Please use option -sockets instead.
 
-`-sockets` `integer (1 - N)` (default=`1`)::
+`-sockets` `<integer> (1 - N)` ('default =' `1`)::
 
 The number of CPU sockets.
 
-`-startdate` `(now | YYYY-MM-DD | YYYY-MM-DDTHH:MM:SS)` (default=`now`)::
+`-startdate` `(now | YYYY-MM-DD | YYYY-MM-DDTHH:MM:SS)` ('default =' `now`)::
 
-Set the initial date of the real time clock. Valid format for date are:
-'now' or '2006-06-17T16:01:21' or '2006-06-17'.
+Set the initial date of the real time clock. Valid format for date are: 'now' or '2006-06-17T16:01:21' or '2006-06-17'.
 
 `-startup` `[[order=]\d+] [,up=\d+] [,down=\d+] ` ::
 
-Startup and shutdown behavior. Order is a non-negative number defining the
-general startup order. Shutdown in done with reverse ordering. Additionally
-you can set the 'up' or 'down' delay in seconds, which specifies a delay to
-wait before the next VM is started or stopped.
+Startup and shutdown behavior. Order is a non-negative number defining the general startup order. Shutdown in done with reverse ordering. Additionally you can set the 'up' or 'down' delay in seconds, which specifies a delay to wait before the next VM is started or stopped.
 
-`-tablet` `boolean` (default=`1`)::
+`-tablet` `<boolean>` ('default =' `1`)::
 
-Enable/disable the USB tablet device. This device is usually needed to
-allow absolute mouse positioning with VNC. Else the mouse runs out of sync
-with normal VNC clients. If you're running lots of console-only guests on
-one host, you may consider disabling this to save some context switches.
-This is turned off by default if you use spice (-vga=qxl).
+Enable/disable the USB tablet device.
 
-`-tdf` `boolean` (default=`0`)::
+`-tdf` `<boolean>` ('default =' `0`)::
 
 Enable/disable time drift fix.
 
-`-template` `boolean` (default=`0`)::
+`-template` `<boolean>` ('default =' `0`)::
 
 Enable/disable Template.
 
-`-unused[n]` `string` ::
+`-unused[n]` `<string>` ::
 
-Reference to unused volumes.
+Reference to unused volumes. This is used internally, and should not be modified manually.
 
-`-usb[n]` `[host=]<HOSTUSBDEVICE|spice> [,usb3=<yes|no>]` ::
+`-usb[n]` `[host=]<HOSTUSBDEVICE|spice> [,usb3=<1|0>]` ::
 
-Configure an USB device (n is 0 to 4). This can be used to
-pass-through usb devices to the guest. HOSTUSBDEVICE syntax is:
-+
-'bus-port(.port)*' (decimal numbers) or
-'vendor_id:product_id' (hexadeciaml numbers) or
-'spice'
-+
-You can use the 'lsusb -t' command to list existing usb devices.
-+
-NOTE: This option allows direct access to host hardware. So it is no longer
-possible to migrate such machines - use with special care.
-+
-The value 'spice' can be used to add a usb redirection devices for spice.
-+
-The 'usb3' option determines whether the device is a USB3 device or not
-(this does currently not work reliably with spice redirection and is then
-ignored).
+Configure an USB device (n is 0 to 4).
 
-`-vcpus` `integer (1 - N)` (default=`0`)::
+`-vcpus` `<integer> (1 - N)` ('default =' `0`)::
 
 Number of hotplugged vcpus.
 
-`-vga` `(cirrus | qxl | qxl2 | qxl3 | qxl4 | serial0 | serial1 | serial2 | serial3 | std | vmware)` ::
+`-vga` `<cirrus | qxl | qxl2 | qxl3 | qxl4 | serial0 | serial1 | serial2 | serial3 | std | vmware>` ::
 
-Select the VGA type. If you want to use high resolution modes (>=
-1280x1024x16) then you should use the options 'std' or 'vmware'. Default is
-'std' for win8/win7/w2k8, and 'cirrus' for other OS types. The 'qxl' option
-enables the SPICE display sever. For win* OS you can select how many
-independent displays you want, Linux guests can add displays them self. You
-can also run without any graphic card, using a serial device as terminal.
+Select the VGA type.
 
-`-virtio[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<on|off>] [,bps=<bps>] [,bps_rd=<bps>] [,bps_wr=<bps>] [,cache=<none|writethrough|writeback|unsafe|directsync>] [,cyls=<count>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<drive format>] [,heads=<count>] [,iops=<iops>] [,iops_max=<iops>] [,iops_rd=<iops>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_max=<iops>] [,iothread=<off|on>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,rerror=<ignore|report|stop>] [,secs=<count>] [,serial=<serial>] [,snapshot=<on|off>] [,trans=<none|lba|auto>] [,werror=<enospc|ignore|report|stop>]` ::
+`-virtio[n]` `[file=]<volume> [,aio=<native|threads>] [,backup=<1|0>] [,bps=<bps>] [,bps_max_length=<seconds>] [,bps_rd=<bps>] [,bps_rd_length=<seconds>] [,bps_wr=<bps>] [,bps_wr_length=<seconds>] [,cache=<enum>] [,cyls=<integer>] [,detect_zeroes=<1|0>] [,discard=<ignore|on>] [,format=<enum>] [,heads=<integer>] [,iops=<iops>] [,iops_max=<iops>] [,iops_max_length=<seconds>] [,iops_rd=<iops>] [,iops_rd_length=<seconds>] [,iops_rd_max=<iops>] [,iops_wr=<iops>] [,iops_wr_length=<seconds>] [,iops_wr_max=<iops>] [,iothread=<1|0>] [,mbps=<mbps>] [,mbps_max=<mbps>] [,mbps_rd=<mbps>] [,mbps_rd_max=<mbps>] [,mbps_wr=<mbps>] [,mbps_wr_max=<mbps>] [,media=<cdrom|disk>] [,rerror=<ignore|report|stop>] [,secs=<integer>] [,serial=<serial>] [,size=<DiskSize>] [,snapshot=<1|0>] [,trans=<none|lba|auto>] [,werror=<enum>]` ::
 
 Use volume as VIRTIO hard disk (n is 0 to 15).
 
-`-watchdog` `[action=<reset|shutdown|poweroff|pause|debug|none>] [,[model=]<i6300esb|ib700>]` ::
+`-watchdog` `[[model=]<i6300esb|ib700>] [,action=<enum>]` ::
 
-Create a virtual hardware watchdog device. Once enabled (by a guest
-action), the watchdog must be periodically polled by an agent inside the
-guest or else the watchdog will reset the guest (or execute the respective
-action specified)
+Create a virtual hardware watchdog device.
 
 
 
@@ -1051,7 +878,7 @@ action specified)
 
 Show command line which is used to start the VM (debug info).
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
@@ -1064,23 +891,23 @@ Shutdown virtual machine. This is similar to pressing the power button on a
 physical machine.This will send an ACPI event for the guest OS, which
 should then proceed to a clean shutdown.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-forceStop` `boolean` (default=`0`)::
+`-forceStop` `<boolean>` ('default =' `0`)::
 
 Make sure the VM stops.
 
-`-keepActive` `boolean` (default=`0`)::
+`-keepActive` `<boolean>` ('default =' `0`)::
 
-Do not decativate storage volumes.
+Do not deactivate storage volumes.
 
-`-skiplock` `boolean` ::
+`-skiplock` `<boolean>` ::
 
 Ignore locks - only root is allowed to use this option.
 
-`-timeout` `integer (0 - N)` ::
+`-timeout` `<integer> (0 - N)` ::
 
 Wait maximal timeout seconds.
 
@@ -1090,19 +917,19 @@ Wait maximal timeout seconds.
 
 Snapshot a VM.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`<snapname>` `string` ::
+`<snapname>`: `<string>` ::
 
 The name of the snapshot.
 
-`-description` `string` ::
+`-description` `<string>` ::
 
 A textual description or comment.
 
-`-vmstate` `boolean` ::
+`-vmstate` `<boolean>` ::
 
 Save the vmstate
 
@@ -1112,7 +939,7 @@ Save the vmstate
 
 Start virtual machine.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
@@ -1120,18 +947,30 @@ The (unique) ID of the VM.
 
 Specific the Qemu machine type.
 
-`-migratedfrom` `string` ::
+`-migratedfrom` `<string>` ::
 
 The cluster node name.
 
-`-skiplock` `boolean` ::
+`-migration_network` `<string>` ::
+
+CIDR of the (sub) network that is used for migration.
+
+`-migration_type` `<insecure | secure>` ::
+
+Migration traffic is encrypted using an SSH tunnel by default. On secure, completely private networks this can be disabled to increase performance.
+
+`-skiplock` `<boolean>` ::
 
 Ignore locks - only root is allowed to use this option.
 
-`-stateuri` `string` ::
+`-stateuri` `<string>` ::
 
 Some command save/restore state from this location.
 
+`-targetstorage` `<string>` ::
+
+Target storage for the migration. (Can be '1' to use the same storage id as on the source node.)
+
 
 
 
@@ -1139,11 +978,11 @@ Some command save/restore state from this location.
 
 Show VM status.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-verbose` `boolean` ::
+`-verbose` `<boolean>` ::
 
 Verbose output format
 
@@ -1155,23 +994,23 @@ Verbose output format
 Stop virtual machine. The qemu process will exit immediately. Thisis akin
 to pulling the power plug of a running computer and may damage the VM data
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-keepActive` `boolean` (default=`0`)::
+`-keepActive` `<boolean>` ('default =' `0`)::
 
-Do not decativate storage volumes.
+Do not deactivate storage volumes.
 
-`-migratedfrom` `string` ::
+`-migratedfrom` `<string>` ::
 
 The cluster node name.
 
-`-skiplock` `boolean` ::
+`-skiplock` `<boolean>` ::
 
 Ignore locks - only root is allowed to use this option.
 
-`-timeout` `integer (0 - N)` ::
+`-timeout` `<integer> (0 - N)` ::
 
 Wait maximal timeout seconds.
 
@@ -1181,11 +1020,11 @@ Wait maximal timeout seconds.
 
 Suspend virtual machine.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-skiplock` `boolean` ::
+`-skiplock` `<boolean>` ::
 
 Ignore locks - only root is allowed to use this option.
 
@@ -1195,11 +1034,11 @@ Ignore locks - only root is allowed to use this option.
 
 Create a Template.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-disk` `(ide0 | ide1 | ide2 | ide3 | sata0 | sata1 | sata2 | sata3 | sata4 | sata5 | scsi0 | scsi1 | scsi10 | scsi11 | scsi12 | scsi13 | scsi2 | scsi3 | scsi4 | scsi5 | scsi6 | scsi7 | scsi8 | scsi9 | virtio0 | virtio1 | virtio10 | virtio11 | virtio12 | virtio13 | virtio14 | virtio15 | virtio2 | virtio3 | virtio4 | virtio5 | virtio6 | virtio7 | virtio8 | virtio9)` ::
+`-disk` `<efidisk0 | ide0 | ide1 | ide2 | ide3 | sata0 | sata1 | sata2 | sata3 | sata4 | sata5 | scsi0 | scsi1 | scsi10 | scsi11 | scsi12 | scsi13 | scsi2 | scsi3 | scsi4 | scsi5 | scsi6 | scsi7 | scsi8 | scsi9 | virtio0 | virtio1 | virtio10 | virtio11 | virtio12 | virtio13 | virtio14 | virtio15 | virtio2 | virtio3 | virtio4 | virtio5 | virtio6 | virtio7 | virtio8 | virtio9>` ::
 
 If you want to convert only 1 disk to base image.
 
@@ -1211,14 +1050,13 @@ If you want to convert only 1 disk to base image.
 Open a terminal using a serial device (The VM need to have a serial device
 configured, for example 'serial0: socket')
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-iface` `(serial0 | serial1 | serial2 | serial3)` ::
+`-iface` `<serial0 | serial1 | serial2 | serial3>` ::
 
-Select the serial device. By default we simply use the first suitable
-device.
+Select the serial device. By default we simply use the first suitable device.
 
 
 
@@ -1227,18 +1065,15 @@ device.
 
 Unlink/delete disk images.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-force` `boolean` ::
+`-force` `<boolean>` ::
 
-Force physical removal. Without this, we simple remove the disk from the
-config file and create an additional configuration entry called
-'unused[n]', which contains the volume ID. Unlink of unused[n] always cause
-physical removal.
+Force physical removal. Without this, we simple remove the disk from the config file and create an additional configuration entry called 'unused[n]', which contains the volume ID. Unlink of unused[n] always cause physical removal.
 
-`-idlist` `string` ::
+`-idlist` `<string>` ::
 
 A list of disk IDs you want to delete.
 
@@ -1249,7 +1084,7 @@ A list of disk IDs you want to delete.
 
 Unlock the VM.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
@@ -1259,7 +1094,7 @@ The (unique) ID of the VM.
 
 Proxy VM VNC traffic to stdin/stdout
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
@@ -1269,11 +1104,11 @@ The (unique) ID of the VM.
 
 Wait until the VM is stopped.
 
-`<vmid>` `integer (1 - N)` ::
+`<vmid>`: `<integer> (1 - N)` ::
 
 The (unique) ID of the VM.
 
-`-timeout` `integer (1 - N)` ::
+`-timeout` `<integer> (1 - N)` ::
 
 Timeout in seconds. Default is to wait forever.