]>
Commit | Line | Data |
---|---|---|
1da177e4 LT |
1 | |
2 | The Linux IPMI Driver | |
3 | --------------------- | |
4 | Corey Minyard | |
5 | <minyard@mvista.com> | |
6 | <minyard@acm.org> | |
7 | ||
8 | The Intelligent Platform Management Interface, or IPMI, is a | |
9 | standard for controlling intelligent devices that monitor a system. | |
10 | It provides for dynamic discovery of sensors in the system and the | |
11 | ability to monitor the sensors and be informed when the sensor's | |
12 | values change or go outside certain boundaries. It also has a | |
dc474c89 | 13 | standardized database for field-replaceable units (FRUs) and a watchdog |
1da177e4 LT |
14 | timer. |
15 | ||
16 | To use this, you need an interface to an IPMI controller in your | |
17 | system (called a Baseboard Management Controller, or BMC) and | |
18 | management software that can use the IPMI system. | |
19 | ||
20 | This document describes how to use the IPMI driver for Linux. If you | |
21 | are not familiar with IPMI itself, see the web site at | |
22 | http://www.intel.com/design/servers/ipmi/index.htm. IPMI is a big | |
23 | subject and I can't cover it all here! | |
24 | ||
25 | Configuration | |
26 | ------------- | |
27 | ||
845e78a1 | 28 | The Linux IPMI driver is modular, which means you have to pick several |
1da177e4 | 29 | things to have it work right depending on your hardware. Most of |
845e78a1 CM |
30 | these are available in the 'Character Devices' menu then the IPMI |
31 | menu. | |
1da177e4 LT |
32 | |
33 | No matter what, you must pick 'IPMI top-level message handler' to use | |
34 | IPMI. What you do beyond that depends on your needs and hardware. | |
35 | ||
36 | The message handler does not provide any user-level interfaces. | |
37 | Kernel code (like the watchdog) can still use it. If you need access | |
38 | from userland, you need to select 'Device interface for IPMI' if you | |
845e78a1 CM |
39 | want access through a device driver. |
40 | ||
41 | The driver interface depends on your hardware. If your system | |
42 | properly provides the SMBIOS info for IPMI, the driver will detect it | |
43 | and just work. If you have a board with a standard interface (These | |
44 | will generally be either "KCS", "SMIC", or "BT", consult your hardware | |
45 | manual), choose the 'IPMI SI handler' option. A driver also exists | |
46 | for direct I2C access to the IPMI management controller. Some boards | |
47 | support this, but it is unknown if it will work on every board. For | |
48 | this, choose 'IPMI SMBus handler', but be ready to try to do some | |
49 | figuring to see if it will work on your system if the SMBIOS/APCI | |
50 | information is wrong or not present. It is fairly safe to have both | |
51 | these enabled and let the drivers auto-detect what is present. | |
1da177e4 LT |
52 | |
53 | You should generally enable ACPI on your system, as systems with IPMI | |
845e78a1 | 54 | can have ACPI tables describing them. |
1da177e4 LT |
55 | |
56 | If you have a standard interface and the board manufacturer has done | |
57 | their job correctly, the IPMI controller should be automatically | |
845e78a1 CM |
58 | detected (via ACPI or SMBIOS tables) and should just work. Sadly, |
59 | many boards do not have this information. The driver attempts | |
60 | standard defaults, but they may not work. If you fall into this | |
61 | situation, you need to read the section below named 'The SI Driver' or | |
62 | "The SMBus Driver" on how to hand-configure your system. | |
1da177e4 LT |
63 | |
64 | IPMI defines a standard watchdog timer. You can enable this with the | |
65 | 'IPMI Watchdog Timer' config option. If you compile the driver into | |
66 | the kernel, then via a kernel command-line option you can have the | |
dc474c89 | 67 | watchdog timer start as soon as it initializes. It also have a lot |
1da177e4 LT |
68 | of other options, see the 'Watchdog' section below for more details. |
69 | Note that you can also have the watchdog continue to run if it is | |
70 | closed (by default it is disabled on close). Go into the 'Watchdog | |
71 | Cards' menu, enable 'Watchdog Timer Support', and enable the option | |
72 | 'Disable watchdog shutdown on close'. | |
73 | ||
845e78a1 CM |
74 | IPMI systems can often be powered off using IPMI commands. Select |
75 | 'IPMI Poweroff' to do this. The driver will auto-detect if the system | |
76 | can be powered off by IPMI. It is safe to enable this even if your | |
77 | system doesn't support this option. This works on ATCA systems, the | |
78 | Radisys CPI1 card, and any IPMI system that supports standard chassis | |
79 | management commands. | |
80 | ||
81 | If you want the driver to put an event into the event log on a panic, | |
82 | enable the 'Generate a panic event to all BMCs on a panic' option. If | |
83 | you want the whole panic string put into the event log using OEM | |
84 | events, enable the 'Generate OEM events containing the panic string' | |
85 | option. | |
1da177e4 LT |
86 | |
87 | Basic Design | |
88 | ------------ | |
89 | ||
90 | The Linux IPMI driver is designed to be very modular and flexible, you | |
91 | only need to take the pieces you need and you can use it in many | |
92 | different ways. Because of that, it's broken into many chunks of | |
845e78a1 | 93 | code. These chunks (by module name) are: |
1da177e4 LT |
94 | |
95 | ipmi_msghandler - This is the central piece of software for the IPMI | |
96 | system. It handles all messages, message timing, and responses. The | |
97 | IPMI users tie into this, and the IPMI physical interfaces (called | |
98 | System Management Interfaces, or SMIs) also tie in here. This | |
99 | provides the kernelland interface for IPMI, but does not provide an | |
100 | interface for use by application processes. | |
101 | ||
102 | ipmi_devintf - This provides a userland IOCTL interface for the IPMI | |
103 | driver, each open file for this device ties in to the message handler | |
104 | as an IPMI user. | |
105 | ||
845e78a1 CM |
106 | ipmi_si - A driver for various system interfaces. This supports KCS, |
107 | SMIC, and BT interfaces. Unless you have an SMBus interface or your | |
108 | own custom interface, you probably need to use this. | |
1da177e4 LT |
109 | |
110 | ipmi_smb - A driver for accessing BMCs on the SMBus. It uses the | |
111 | I2C kernel driver's SMBus interfaces to send and receive IPMI messages | |
112 | over the SMBus. | |
113 | ||
845e78a1 CM |
114 | ipmi_watchdog - IPMI requires systems to have a very capable watchdog |
115 | timer. This driver implements the standard Linux watchdog timer | |
116 | interface on top of the IPMI message handler. | |
117 | ||
118 | ipmi_poweroff - Some systems support the ability to be turned off via | |
119 | IPMI commands. | |
120 | ||
121 | These are all individually selectable via configuration options. | |
1da177e4 | 122 | |
845e78a1 CM |
123 | Note that the KCS-only interface has been removed. The af_ipmi driver |
124 | is no longer supported and has been removed because it was impossible | |
125 | to do 32 bit emulation on 64-bit kernels with it. | |
1da177e4 LT |
126 | |
127 | Much documentation for the interface is in the include files. The | |
128 | IPMI include files are: | |
129 | ||
130 | net/af_ipmi.h - Contains the socket interface. | |
131 | ||
132 | linux/ipmi.h - Contains the user interface and IOCTL interface for IPMI. | |
133 | ||
134 | linux/ipmi_smi.h - Contains the interface for system management interfaces | |
135 | (things that interface to IPMI controllers) to use. | |
136 | ||
137 | linux/ipmi_msgdefs.h - General definitions for base IPMI messaging. | |
138 | ||
139 | ||
140 | Addressing | |
141 | ---------- | |
142 | ||
143 | The IPMI addressing works much like IP addresses, you have an overlay | |
144 | to handle the different address types. The overlay is: | |
145 | ||
146 | struct ipmi_addr | |
147 | { | |
148 | int addr_type; | |
149 | short channel; | |
150 | char data[IPMI_MAX_ADDR_SIZE]; | |
151 | }; | |
152 | ||
153 | The addr_type determines what the address really is. The driver | |
154 | currently understands two different types of addresses. | |
155 | ||
156 | "System Interface" addresses are defined as: | |
157 | ||
158 | struct ipmi_system_interface_addr | |
159 | { | |
160 | int addr_type; | |
161 | short channel; | |
162 | }; | |
163 | ||
164 | and the type is IPMI_SYSTEM_INTERFACE_ADDR_TYPE. This is used for talking | |
165 | straight to the BMC on the current card. The channel must be | |
166 | IPMI_BMC_CHANNEL. | |
167 | ||
168 | Messages that are destined to go out on the IPMB bus use the | |
169 | IPMI_IPMB_ADDR_TYPE address type. The format is | |
170 | ||
171 | struct ipmi_ipmb_addr | |
172 | { | |
173 | int addr_type; | |
174 | short channel; | |
175 | unsigned char slave_addr; | |
176 | unsigned char lun; | |
177 | }; | |
178 | ||
179 | The "channel" here is generally zero, but some devices support more | |
180 | than one channel, it corresponds to the channel as defined in the IPMI | |
181 | spec. | |
182 | ||
183 | ||
184 | Messages | |
185 | -------- | |
186 | ||
187 | Messages are defined as: | |
188 | ||
189 | struct ipmi_msg | |
190 | { | |
191 | unsigned char netfn; | |
192 | unsigned char lun; | |
193 | unsigned char cmd; | |
194 | unsigned char *data; | |
195 | int data_len; | |
196 | }; | |
197 | ||
198 | The driver takes care of adding/stripping the header information. The | |
199 | data portion is just the data to be send (do NOT put addressing info | |
200 | here) or the response. Note that the completion code of a response is | |
201 | the first item in "data", it is not stripped out because that is how | |
202 | all the messages are defined in the spec (and thus makes counting the | |
203 | offsets a little easier :-). | |
204 | ||
205 | When using the IOCTL interface from userland, you must provide a block | |
206 | of data for "data", fill it, and set data_len to the length of the | |
207 | block of data, even when receiving messages. Otherwise the driver | |
208 | will have no place to put the message. | |
209 | ||
210 | Messages coming up from the message handler in kernelland will come in | |
211 | as: | |
212 | ||
213 | struct ipmi_recv_msg | |
214 | { | |
215 | struct list_head link; | |
216 | ||
217 | /* The type of message as defined in the "Receive Types" | |
218 | defines above. */ | |
219 | int recv_type; | |
220 | ||
221 | ipmi_user_t *user; | |
222 | struct ipmi_addr addr; | |
223 | long msgid; | |
224 | struct ipmi_msg msg; | |
225 | ||
226 | /* Call this when done with the message. It will presumably free | |
227 | the message and do any other necessary cleanup. */ | |
228 | void (*done)(struct ipmi_recv_msg *msg); | |
229 | ||
230 | /* Place-holder for the data, don't make any assumptions about | |
231 | the size or existence of this, since it may change. */ | |
232 | unsigned char msg_data[IPMI_MAX_MSG_LENGTH]; | |
233 | }; | |
234 | ||
235 | You should look at the receive type and handle the message | |
236 | appropriately. | |
237 | ||
238 | ||
239 | The Upper Layer Interface (Message Handler) | |
240 | ------------------------------------------- | |
241 | ||
242 | The upper layer of the interface provides the users with a consistent | |
243 | view of the IPMI interfaces. It allows multiple SMI interfaces to be | |
244 | addressed (because some boards actually have multiple BMCs on them) | |
245 | and the user should not have to care what type of SMI is below them. | |
246 | ||
247 | ||
248 | Creating the User | |
249 | ||
250 | To user the message handler, you must first create a user using | |
251 | ipmi_create_user. The interface number specifies which SMI you want | |
252 | to connect to, and you must supply callback functions to be called | |
253 | when data comes in. The callback function can run at interrupt level, | |
254 | so be careful using the callbacks. This also allows to you pass in a | |
255 | piece of data, the handler_data, that will be passed back to you on | |
256 | all calls. | |
257 | ||
258 | Once you are done, call ipmi_destroy_user() to get rid of the user. | |
259 | ||
260 | From userland, opening the device automatically creates a user, and | |
261 | closing the device automatically destroys the user. | |
262 | ||
263 | ||
264 | Messaging | |
265 | ||
266 | To send a message from kernel-land, the ipmi_request() call does | |
267 | pretty much all message handling. Most of the parameter are | |
268 | self-explanatory. However, it takes a "msgid" parameter. This is NOT | |
269 | the sequence number of messages. It is simply a long value that is | |
270 | passed back when the response for the message is returned. You may | |
271 | use it for anything you like. | |
272 | ||
273 | Responses come back in the function pointed to by the ipmi_recv_hndl | |
274 | field of the "handler" that you passed in to ipmi_create_user(). | |
275 | Remember again, these may be running at interrupt level. Remember to | |
276 | look at the receive type, too. | |
277 | ||
278 | From userland, you fill out an ipmi_req_t structure and use the | |
279 | IPMICTL_SEND_COMMAND ioctl. For incoming stuff, you can use select() | |
280 | or poll() to wait for messages to come in. However, you cannot use | |
281 | read() to get them, you must call the IPMICTL_RECEIVE_MSG with the | |
282 | ipmi_recv_t structure to actually get the message. Remember that you | |
283 | must supply a pointer to a block of data in the msg.data field, and | |
284 | you must fill in the msg.data_len field with the size of the data. | |
285 | This gives the receiver a place to actually put the message. | |
286 | ||
287 | If the message cannot fit into the data you provide, you will get an | |
288 | EMSGSIZE error and the driver will leave the data in the receive | |
289 | queue. If you want to get it and have it truncate the message, us | |
290 | the IPMICTL_RECEIVE_MSG_TRUNC ioctl. | |
291 | ||
292 | When you send a command (which is defined by the lowest-order bit of | |
293 | the netfn per the IPMI spec) on the IPMB bus, the driver will | |
294 | automatically assign the sequence number to the command and save the | |
295 | command. If the response is not receive in the IPMI-specified 5 | |
296 | seconds, it will generate a response automatically saying the command | |
297 | timed out. If an unsolicited response comes in (if it was after 5 | |
298 | seconds, for instance), that response will be ignored. | |
299 | ||
300 | In kernelland, after you receive a message and are done with it, you | |
301 | MUST call ipmi_free_recv_msg() on it, or you will leak messages. Note | |
302 | that you should NEVER mess with the "done" field of a message, that is | |
303 | required to properly clean up the message. | |
304 | ||
305 | Note that when sending, there is an ipmi_request_supply_msgs() call | |
306 | that lets you supply the smi and receive message. This is useful for | |
307 | pieces of code that need to work even if the system is out of buffers | |
308 | (the watchdog timer uses this, for instance). You supply your own | |
309 | buffer and own free routines. This is not recommended for normal use, | |
310 | though, since it is tricky to manage your own buffers. | |
311 | ||
312 | ||
313 | Events and Incoming Commands | |
314 | ||
315 | The driver takes care of polling for IPMI events and receiving | |
316 | commands (commands are messages that are not responses, they are | |
317 | commands that other things on the IPMB bus have sent you). To receive | |
318 | these, you must register for them, they will not automatically be sent | |
319 | to you. | |
320 | ||
321 | To receive events, you must call ipmi_set_gets_events() and set the | |
322 | "val" to non-zero. Any events that have been received by the driver | |
323 | since startup will immediately be delivered to the first user that | |
324 | registers for events. After that, if multiple users are registered | |
325 | for events, they will all receive all events that come in. | |
326 | ||
327 | For receiving commands, you have to individually register commands you | |
328 | want to receive. Call ipmi_register_for_cmd() and supply the netfn | |
c69c3127 CM |
329 | and command name for each command you want to receive. You also |
330 | specify a bitmask of the channels you want to receive the command from | |
331 | (or use IPMI_CHAN_ALL for all channels if you don't care). Only one | |
332 | user may be registered for each netfn/cmd/channel, but different users | |
333 | may register for different commands, or the same command if the | |
334 | channel bitmasks do not overlap. | |
1da177e4 LT |
335 | |
336 | From userland, equivalent IOCTLs are provided to do these functions. | |
337 | ||
338 | ||
339 | The Lower Layer (SMI) Interface | |
340 | ------------------------------- | |
341 | ||
342 | As mentioned before, multiple SMI interfaces may be registered to the | |
343 | message handler, each of these is assigned an interface number when | |
344 | they register with the message handler. They are generally assigned | |
345 | in the order they register, although if an SMI unregisters and then | |
346 | another one registers, all bets are off. | |
347 | ||
348 | The ipmi_smi.h defines the interface for management interfaces, see | |
349 | that for more details. | |
350 | ||
351 | ||
352 | The SI Driver | |
353 | ------------- | |
354 | ||
355 | The SI driver allows up to 4 KCS or SMIC interfaces to be configured | |
356 | in the system. By default, scan the ACPI tables for interfaces, and | |
357 | if it doesn't find any the driver will attempt to register one KCS | |
358 | interface at the spec-specified I/O port 0xca2 without interrupts. | |
359 | You can change this at module load time (for a module) with: | |
360 | ||
361 | modprobe ipmi_si.o type=<type1>,<type2>.... | |
362 | ports=<port1>,<port2>... addrs=<addr1>,<addr2>... | |
363 | irqs=<irq1>,<irq2>... trydefaults=[0|1] | |
364 | regspacings=<sp1>,<sp2>,... regsizes=<size1>,<size2>,... | |
365 | regshifts=<shift1>,<shift2>,... | |
366 | slave_addrs=<addr1>,<addr2>,... | |
a51f4a81 | 367 | force_kipmid=<enable1>,<enable2>,... |
b361e27b | 368 | unload_when_empty=[0|1] |
1da177e4 LT |
369 | |
370 | Each of these except si_trydefaults is a list, the first item for the | |
371 | first interface, second item for the second interface, etc. | |
372 | ||
373 | The si_type may be either "kcs", "smic", or "bt". If you leave it blank, it | |
374 | defaults to "kcs". | |
375 | ||
376 | If you specify si_addrs as non-zero for an interface, the driver will | |
377 | use the memory address given as the address of the device. This | |
378 | overrides si_ports. | |
379 | ||
380 | If you specify si_ports as non-zero for an interface, the driver will | |
381 | use the I/O port given as the device address. | |
382 | ||
383 | If you specify si_irqs as non-zero for an interface, the driver will | |
384 | attempt to use the given interrupt for the device. | |
385 | ||
386 | si_trydefaults sets whether the standard IPMI interface at 0xca2 and | |
387 | any interfaces specified by ACPE are tried. By default, the driver | |
388 | tries it, set this value to zero to turn this off. | |
389 | ||
390 | The next three parameters have to do with register layout. The | |
391 | registers used by the interfaces may not appear at successive | |
392 | locations and they may not be in 8-bit registers. These parameters | |
393 | allow the layout of the data in the registers to be more precisely | |
394 | specified. | |
395 | ||
396 | The regspacings parameter give the number of bytes between successive | |
397 | register start addresses. For instance, if the regspacing is set to 4 | |
398 | and the start address is 0xca2, then the address for the second | |
399 | register would be 0xca6. This defaults to 1. | |
400 | ||
401 | The regsizes parameter gives the size of a register, in bytes. The | |
402 | data used by IPMI is 8-bits wide, but it may be inside a larger | |
403 | register. This parameter allows the read and write type to specified. | |
404 | It may be 1, 2, 4, or 8. The default is 1. | |
405 | ||
406 | Since the register size may be larger than 32 bits, the IPMI data may not | |
407 | be in the lower 8 bits. The regshifts parameter give the amount to shift | |
408 | the data to get to the actual IPMI data. | |
409 | ||
410 | The slave_addrs specifies the IPMI address of the local BMC. This is | |
411 | usually 0x20 and the driver defaults to that, but in case it's not, it | |
412 | can be specified when the driver starts up. | |
413 | ||
a51f4a81 CM |
414 | The force_ipmid parameter forcefully enables (if set to 1) or disables |
415 | (if set to 0) the kernel IPMI daemon. Normally this is auto-detected | |
416 | by the driver, but systems with broken interrupts might need an enable, | |
417 | or users that don't want the daemon (don't need the performance, don't | |
418 | want the CPU hit) can disable it. | |
419 | ||
b361e27b CM |
420 | If unload_when_empty is set to 1, the driver will be unloaded if it |
421 | doesn't find any interfaces or all the interfaces fail to work. The | |
422 | default is one. Setting to 0 is useful with the hotmod, but is | |
423 | obviously only useful for modules. | |
424 | ||
a51f4a81 | 425 | When compiled into the kernel, the parameters can be specified on the |
1da177e4 LT |
426 | kernel command line as: |
427 | ||
428 | ipmi_si.type=<type1>,<type2>... | |
429 | ipmi_si.ports=<port1>,<port2>... ipmi_si.addrs=<addr1>,<addr2>... | |
430 | ipmi_si.irqs=<irq1>,<irq2>... ipmi_si.trydefaults=[0|1] | |
431 | ipmi_si.regspacings=<sp1>,<sp2>,... | |
432 | ipmi_si.regsizes=<size1>,<size2>,... | |
433 | ipmi_si.regshifts=<shift1>,<shift2>,... | |
434 | ipmi_si.slave_addrs=<addr1>,<addr2>,... | |
a51f4a81 | 435 | ipmi_si.force_kipmid=<enable1>,<enable2>,... |
1da177e4 LT |
436 | |
437 | It works the same as the module parameters of the same names. | |
438 | ||
439 | By default, the driver will attempt to detect any device specified by | |
440 | ACPI, and if none of those then a KCS device at the spec-specified | |
441 | 0xca2. If you want to turn this off, set the "trydefaults" option to | |
442 | false. | |
443 | ||
444 | If you have high-res timers compiled into the kernel, the driver will | |
445 | use them to provide much better performance. Note that if you do not | |
446 | have high-res timers enabled in the kernel and you don't have | |
447 | interrupts enabled, the driver will run VERY slowly. Don't blame me, | |
448 | these interfaces suck. | |
449 | ||
b361e27b CM |
450 | The driver supports a hot add and remove of interfaces. This way, |
451 | interfaces can be added or removed after the kernel is up and running. | |
452 | This is done using /sys/modules/ipmi_si/hotmod, which is a write-only | |
453 | parameter. You write a string to this interface. The string has the | |
454 | format: | |
455 | <op1>[:op2[:op3...]] | |
456 | The "op"s are: | |
457 | add|remove,kcs|bt|smic,mem|i/o,<address>[,<opt1>[,<opt2>[,...]]] | |
458 | You can specify more than one interface on the line. The "opt"s are: | |
459 | rsp=<regspacing> | |
460 | rsi=<regsize> | |
461 | rsh=<regshift> | |
462 | irq=<irq> | |
463 | ipmb=<ipmb slave addr> | |
464 | and these have the same meanings as discussed above. Note that you | |
465 | can also use this on the kernel command line for a more compact format | |
466 | for specifying an interface. Note that when removing an interface, | |
467 | only the first three parameters (si type, address type, and address) | |
468 | are used for the comparison. Any options are ignored for removing. | |
1da177e4 LT |
469 | |
470 | The SMBus Driver | |
471 | ---------------- | |
472 | ||
473 | The SMBus driver allows up to 4 SMBus devices to be configured in the | |
474 | system. By default, the driver will register any SMBus interfaces it finds | |
475 | in the I2C address range of 0x20 to 0x4f on any adapter. You can change this | |
476 | at module load time (for a module) with: | |
477 | ||
478 | modprobe ipmi_smb.o | |
479 | addr=<adapter1>,<i2caddr1>[,<adapter2>,<i2caddr2>[,...]] | |
480 | dbg=<flags1>,<flags2>... | |
845e78a1 | 481 | [defaultprobe=1] [dbg_probe=1] |
1da177e4 LT |
482 | |
483 | The addresses are specified in pairs, the first is the adapter ID and the | |
484 | second is the I2C address on that adapter. | |
485 | ||
486 | The debug flags are bit flags for each BMC found, they are: | |
487 | IPMI messages: 1, driver state: 2, timing: 4, I2C probe: 8 | |
488 | ||
489 | Setting smb_defaultprobe to zero disabled the default probing of SMBus | |
490 | interfaces at address range 0x20 to 0x4f. This means that only the | |
491 | BMCs specified on the smb_addr line will be detected. | |
492 | ||
493 | Setting smb_dbg_probe to 1 will enable debugging of the probing and | |
494 | detection process for BMCs on the SMBusses. | |
495 | ||
6c28f2c0 | 496 | Discovering the IPMI compliant BMC on the SMBus can cause devices |
1da177e4 LT |
497 | on the I2C bus to fail. The SMBus driver writes a "Get Device ID" IPMI |
498 | message as a block write to the I2C bus and waits for a response. | |
499 | This action can be detrimental to some I2C devices. It is highly recommended | |
500 | that the known I2c address be given to the SMBus driver in the smb_addr | |
3f6dee9b | 501 | parameter. The default address range will not be used when a smb_addr |
1da177e4 LT |
502 | parameter is provided. |
503 | ||
504 | When compiled into the kernel, the addresses can be specified on the | |
505 | kernel command line as: | |
506 | ||
507 | ipmb_smb.addr=<adapter1>,<i2caddr1>[,<adapter2>,<i2caddr2>[,...]] | |
508 | ipmi_smb.dbg=<flags1>,<flags2>... | |
509 | ipmi_smb.defaultprobe=0 ipmi_smb.dbg_probe=1 | |
510 | ||
511 | These are the same options as on the module command line. | |
512 | ||
513 | Note that you might need some I2C changes if CONFIG_IPMI_PANIC_EVENT | |
514 | is enabled along with this, so the I2C driver knows to run to | |
515 | completion during sending a panic event. | |
516 | ||
517 | ||
518 | Other Pieces | |
519 | ------------ | |
520 | ||
521 | Watchdog | |
522 | -------- | |
523 | ||
524 | A watchdog timer is provided that implements the Linux-standard | |
525 | watchdog timer interface. It has three module parameters that can be | |
526 | used to control it: | |
527 | ||
528 | modprobe ipmi_watchdog timeout=<t> pretimeout=<t> action=<action type> | |
529 | preaction=<preaction type> preop=<preop type> start_now=x | |
b2c03941 CM |
530 | nowayout=x ifnum_to_use=n |
531 | ||
532 | ifnum_to_use specifies which interface the watchdog timer should use. | |
533 | The default is -1, which means to pick the first one registered. | |
1da177e4 LT |
534 | |
535 | The timeout is the number of seconds to the action, and the pretimeout | |
536 | is the amount of seconds before the reset that the pre-timeout panic will | |
537 | occur (if pretimeout is zero, then pretimeout will not be enabled). Note | |
538 | that the pretimeout is the time before the final timeout. So if the | |
539 | timeout is 50 seconds and the pretimeout is 10 seconds, then the pretimeout | |
540 | will occur in 40 second (10 seconds before the timeout). | |
541 | ||
542 | The action may be "reset", "power_cycle", or "power_off", and | |
543 | specifies what to do when the timer times out, and defaults to | |
544 | "reset". | |
545 | ||
546 | The preaction may be "pre_smi" for an indication through the SMI | |
547 | interface, "pre_int" for an indication through the SMI with an | |
548 | interrupts, and "pre_nmi" for a NMI on a preaction. This is how | |
549 | the driver is informed of the pretimeout. | |
550 | ||
551 | The preop may be set to "preop_none" for no operation on a pretimeout, | |
552 | "preop_panic" to set the preoperation to panic, or "preop_give_data" | |
553 | to provide data to read from the watchdog device when the pretimeout | |
554 | occurs. A "pre_nmi" setting CANNOT be used with "preop_give_data" | |
555 | because you can't do data operations from an NMI. | |
556 | ||
557 | When preop is set to "preop_give_data", one byte comes ready to read | |
558 | on the device when the pretimeout occurs. Select and fasync work on | |
559 | the device, as well. | |
560 | ||
561 | If start_now is set to 1, the watchdog timer will start running as | |
562 | soon as the driver is loaded. | |
563 | ||
564 | If nowayout is set to 1, the watchdog timer will not stop when the | |
565 | watchdog device is closed. The default value of nowayout is true | |
566 | if the CONFIG_WATCHDOG_NOWAYOUT option is enabled, or false if not. | |
567 | ||
568 | When compiled into the kernel, the kernel command line is available | |
569 | for configuring the watchdog: | |
570 | ||
571 | ipmi_watchdog.timeout=<t> ipmi_watchdog.pretimeout=<t> | |
572 | ipmi_watchdog.action=<action type> | |
573 | ipmi_watchdog.preaction=<preaction type> | |
574 | ipmi_watchdog.preop=<preop type> | |
575 | ipmi_watchdog.start_now=x | |
576 | ipmi_watchdog.nowayout=x | |
577 | ||
578 | The options are the same as the module parameter options. | |
579 | ||
580 | The watchdog will panic and start a 120 second reset timeout if it | |
581 | gets a pre-action. During a panic or a reboot, the watchdog will | |
582 | start a 120 timer if it is running to make sure the reboot occurs. | |
583 | ||
584 | Note that if you use the NMI preaction for the watchdog, you MUST | |
585 | NOT use nmi watchdog mode 1. If you use the NMI watchdog, you | |
586 | must use mode 2. | |
587 | ||
588 | Once you open the watchdog timer, you must write a 'V' character to the | |
589 | device to close it, or the timer will not stop. This is a new semantic | |
590 | for the driver, but makes it consistent with the rest of the watchdog | |
591 | drivers in Linux. | |
845e78a1 CM |
592 | |
593 | ||
594 | Panic Timeouts | |
595 | -------------- | |
596 | ||
597 | The OpenIPMI driver supports the ability to put semi-custom and custom | |
598 | events in the system event log if a panic occurs. if you enable the | |
599 | 'Generate a panic event to all BMCs on a panic' option, you will get | |
600 | one event on a panic in a standard IPMI event format. If you enable | |
601 | the 'Generate OEM events containing the panic string' option, you will | |
602 | also get a bunch of OEM events holding the panic string. | |
603 | ||
604 | ||
605 | The field settings of the events are: | |
606 | * Generator ID: 0x21 (kernel) | |
607 | * EvM Rev: 0x03 (this event is formatting in IPMI 1.0 format) | |
608 | * Sensor Type: 0x20 (OS critical stop sensor) | |
609 | * Sensor #: The first byte of the panic string (0 if no panic string) | |
610 | * Event Dir | Event Type: 0x6f (Assertion, sensor-specific event info) | |
611 | * Event Data 1: 0xa1 (Runtime stop in OEM bytes 2 and 3) | |
612 | * Event data 2: second byte of panic string | |
613 | * Event data 3: third byte of panic string | |
614 | See the IPMI spec for the details of the event layout. This event is | |
615 | always sent to the local management controller. It will handle routing | |
616 | the message to the right place | |
617 | ||
618 | Other OEM events have the following format: | |
619 | Record ID (bytes 0-1): Set by the SEL. | |
620 | Record type (byte 2): 0xf0 (OEM non-timestamped) | |
621 | byte 3: The slave address of the card saving the panic | |
622 | byte 4: A sequence number (starting at zero) | |
623 | The rest of the bytes (11 bytes) are the panic string. If the panic string | |
624 | is longer than 11 bytes, multiple messages will be sent with increasing | |
625 | sequence numbers. | |
626 | ||
627 | Because you cannot send OEM events using the standard interface, this | |
628 | function will attempt to find an SEL and add the events there. It | |
629 | will first query the capabilities of the local management controller. | |
630 | If it has an SEL, then they will be stored in the SEL of the local | |
631 | management controller. If not, and the local management controller is | |
632 | an event generator, the event receiver from the local management | |
633 | controller will be queried and the events sent to the SEL on that | |
634 | device. Otherwise, the events go nowhere since there is nowhere to | |
635 | send them. | |
3b625943 CM |
636 | |
637 | ||
638 | Poweroff | |
639 | -------- | |
640 | ||
641 | If the poweroff capability is selected, the IPMI driver will install | |
642 | a shutdown function into the standard poweroff function pointer. This | |
643 | is in the ipmi_poweroff module. When the system requests a powerdown, | |
644 | it will send the proper IPMI commands to do this. This is supported on | |
645 | several platforms. | |
646 | ||
8c702e16 CM |
647 | There is a module parameter named "poweroff_powercycle" that may |
648 | either be zero (do a power down) or non-zero (do a power cycle, power | |
649 | the system off, then power it on in a few seconds). Setting | |
650 | ipmi_poweroff.poweroff_control=x will do the same thing on the kernel | |
651 | command line. The parameter is also available via the proc filesystem | |
652 | in /proc/sys/dev/ipmi/poweroff_powercycle. Note that if the system | |
653 | does not support power cycling, it will always do the power off. | |
3b625943 | 654 | |
b2c03941 CM |
655 | The "ifnum_to_use" parameter specifies which interface the poweroff |
656 | code should use. The default is -1, which means to pick the first one | |
657 | registered. | |
658 | ||
3b625943 CM |
659 | Note that if you have ACPI enabled, the system will prefer using ACPI to |
660 | power off. |