]> git.proxmox.com Git - mirror_ubuntu-artful-kernel.git/blame - Documentation/hwmon/max34440
ipv4: convert dst_metrics.refcnt from atomic_t to refcount_t
[mirror_ubuntu-artful-kernel.git] / Documentation / hwmon / max34440
CommitLineData
e428d8d3
GR
1Kernel driver max34440
2======================
3
4Supported chips:
5 * Maxim MAX34440
6 Prefixes: 'max34440'
7 Addresses scanned: -
1dc2c9f5 8 Datasheet: http://datasheets.maximintegrated.com/en/ds/MAX34440.pdf
e428d8d3
GR
9 * Maxim MAX34441
10 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller
11 Prefixes: 'max34441'
12 Addresses scanned: -
1dc2c9f5 13 Datasheet: http://datasheets.maximintegrated.com/en/ds/MAX34441.pdf
590defe5
GR
14 * Maxim MAX34446
15 PMBus Power-Supply Data Logger
16 Prefixes: 'max34446'
17 Addresses scanned: -
1dc2c9f5 18 Datasheet: http://datasheets.maximintegrated.com/en/ds/MAX34446.pdf
50115ac9
GR
19 * Maxim MAX34460
20 PMBus 12-Channel Voltage Monitor & Sequencer
21 Prefix: 'max34460'
22 Addresses scanned: -
23 Datasheet: http://datasheets.maximintegrated.com/en/ds/MAX34460.pdf
24 * Maxim MAX34461
25 PMBus 16-Channel Voltage Monitor & Sequencer
26 Prefix: 'max34461'
27 Addresses scanned: -
28 Datasheet: http://datasheets.maximintegrated.com/en/ds/MAX34461.pdf
e428d8d3 29
e3333e57 30Author: Guenter Roeck <linux@roeck-us.net>
e428d8d3
GR
31
32
33Description
34-----------
35
92417dad 36This driver supports hardware monitoring for Maxim MAX34440 PMBus 6-Channel
590defe5
GR
37Power-Supply Manager, MAX34441 PMBus 5-Channel Power-Supply Manager
38and Intelligent Fan Controller, and MAX34446 PMBus Power-Supply Data Logger.
50115ac9
GR
39It also supports the MAX34460 and MAX34461 PMBus Voltage Monitor & Sequencers.
40The MAX34460 supports 12 voltage channels, and the MAX34461 supports 16 voltage
41channels.
e428d8d3
GR
42
43The driver is a client driver to the core PMBus driver. Please see
44Documentation/hwmon/pmbus for details on PMBus client drivers.
45
46
47Usage Notes
48-----------
49
50This driver does not auto-detect devices. You will have to instantiate the
51devices explicitly. Please see Documentation/i2c/instantiating-devices for
52details.
53
590defe5
GR
54For MAX34446, the value of the currX_crit attribute determines if current or
55voltage measurement is enabled for a given channel. Voltage measurement is
56enabled if currX_crit is set to 0; current measurement is enabled if the
57attribute is set to a positive value. Power measurement is only enabled if
58channel 1 (3) is configured for voltage measurement, and channel 2 (4) is
59configured for current measurement.
60
e428d8d3
GR
61
62Platform data support
63---------------------
64
65The driver supports standard PMBus driver platform data.
66
67
68Sysfs entries
69-------------
70
71The following attributes are supported. Limits are read-write; all other
72attributes are read-only.
73
74in[1-6]_label "vout[1-6]".
75in[1-6]_input Measured voltage. From READ_VOUT register.
40e47125 76in[1-6]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
e428d8d3 77in[1-6]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
40e47125 78in[1-6]_lcrit Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register.
e428d8d3
GR
79in[1-6]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
80in[1-6]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
81in[1-6]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
82in[1-6]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
83in[1-6]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
56aad5d1 84in[1-6]_lowest Historical minimum voltage.
98591dbe
GR
85in[1-6]_highest Historical maximum voltage.
86in[1-6]_reset_history Write any value to reset history.
e428d8d3 87
590defe5
GR
88 MAX34446 only supports in[1-4].
89
e428d8d3
GR
90curr[1-6]_label "iout[1-6]".
91curr[1-6]_input Measured current. From READ_IOUT register.
92curr[1-6]_max Maximum current. From IOUT_OC_WARN_LIMIT register.
93curr[1-6]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
94curr[1-6]_max_alarm Current high alarm. From IOUT_OC_WARNING status.
95curr[1-6]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.
590defe5 96curr[1-4]_average Historical average current (MAX34446 only).
98591dbe
GR
97curr[1-6]_highest Historical maximum current.
98curr[1-6]_reset_history Write any value to reset history.
e428d8d3
GR
99
100 in6 and curr6 attributes only exist for MAX34440.
590defe5
GR
101 MAX34446 only supports curr[1-4].
102
103power[1,3]_label "pout[1,3]"
104power[1,3]_input Measured power.
105power[1,3]_average Historical average power.
106power[1,3]_highest Historical maximum power.
107
108 Power attributes only exist for MAX34446.
e428d8d3
GR
109
110temp[1-8]_input Measured temperatures. From READ_TEMPERATURE_1 register.
111 temp1 is the chip's internal temperature. temp2..temp5
112 are remote I2C temperature sensors. For MAX34441, temp6
113 is a remote thermal-diode sensor. For MAX34440, temp6..8
114 are remote I2C temperature sensors.
115temp[1-8]_max Maximum temperature. From OT_WARN_LIMIT register.
116temp[1-8]_crit Critical high temperature. From OT_FAULT_LIMIT register.
117temp[1-8]_max_alarm Temperature high alarm.
118temp[1-8]_crit_alarm Temperature critical high alarm.
590defe5 119temp[1-8]_average Historical average temperature (MAX34446 only).
98591dbe
GR
120temp[1-8]_highest Historical maximum temperature.
121temp[1-8]_reset_history Write any value to reset history.
e428d8d3
GR
122
123 temp7 and temp8 attributes only exist for MAX34440.
590defe5 124 MAX34446 only supports temp[1-3].
50115ac9
GR
125
126MAX34460 supports attribute groups in[1-12] and temp[1-5].
127MAX34461 supports attribute groups in[1-16] and temp[1-5].