]> git.proxmox.com Git - mirror_ubuntu-artful-kernel.git/blame - Documentation/networking/bonding.txt
HID: multitouch: validate indexes details
[mirror_ubuntu-artful-kernel.git] / Documentation / networking / bonding.txt
CommitLineData
1da177e4 1
00354cfb
JV
2 Linux Ethernet Bonding Driver HOWTO
3
ad246c99 4 Latest update: 27 April 2011
1da177e4
LT
5
6Initial release : Thomas Davis <tadavis at lbl.gov>
7Corrections, HA extensions : 2000/10/03-15 :
8 - Willy Tarreau <willy at meta-x.org>
9 - Constantine Gavrilov <const-g at xpert.com>
10 - Chad N. Tindel <ctindel at ieee dot org>
11 - Janice Girouard <girouard at us dot ibm dot com>
12 - Jay Vosburgh <fubar at us dot ibm dot com>
13
14Reorganized and updated Feb 2005 by Jay Vosburgh
6224e01d
AK
15Added Sysfs information: 2006/04/24
16 - Mitch Williams <mitch.a.williams at intel.com>
1da177e4 17
00354cfb
JV
18Introduction
19============
20
21 The Linux bonding driver provides a method for aggregating
22multiple network interfaces into a single logical "bonded" interface.
23The behavior of the bonded interfaces depends upon the mode; generally
24speaking, modes provide either hot standby or load balancing services.
25Additionally, link integrity monitoring may be performed.
1da177e4 26
00354cfb
JV
27 The bonding driver originally came from Donald Becker's
28beowulf patches for kernel 2.0. It has changed quite a bit since, and
29the original tools from extreme-linux and beowulf sites will not work
30with this version of the driver.
1da177e4 31
00354cfb
JV
32 For new versions of the driver, updated userspace tools, and
33who to ask for help, please follow the links at the end of this file.
1da177e4
LT
34
35Table of Contents
36=================
37
381. Bonding Driver Installation
39
402. Bonding Driver Options
41
423. Configuring Bonding Devices
6224e01d
AK
433.1 Configuration with Sysconfig Support
443.1.1 Using DHCP with Sysconfig
453.1.2 Configuring Multiple Bonds with Sysconfig
463.2 Configuration with Initscripts Support
473.2.1 Using DHCP with Initscripts
483.2.2 Configuring Multiple Bonds with Initscripts
493.3 Configuring Bonding Manually with Ifenslave
00354cfb 503.3.1 Configuring Multiple Bonds Manually
6224e01d 513.4 Configuring Bonding Manually via Sysfs
de221bd5
NP
523.5 Configuration with Interfaces Support
533.6 Overriding Configuration for Special Cases
1da177e4 54
6224e01d
AK
554. Querying Bonding Configuration
564.1 Bonding Configuration
574.2 Network Configuration
1da177e4 58
6224e01d 595. Switch Configuration
1da177e4 60
6224e01d 616. 802.1q VLAN Support
1da177e4 62
6224e01d
AK
637. Link Monitoring
647.1 ARP Monitor Operation
657.2 Configuring Multiple ARP Targets
667.3 MII Monitor Operation
1da177e4 67
6224e01d
AK
688. Potential Trouble Sources
698.1 Adventures in Routing
708.2 Ethernet Device Renaming
718.3 Painfully Slow Or No Failed Link Detection By Miimon
1da177e4 72
6224e01d 739. SNMP agents
1da177e4 74
6224e01d 7510. Promiscuous mode
1da177e4 76
6224e01d
AK
7711. Configuring Bonding for High Availability
7811.1 High Availability in a Single Switch Topology
7911.2 High Availability in a Multiple Switch Topology
8011.2.1 HA Bonding Mode Selection for Multiple Switch Topology
8111.2.2 HA Link Monitoring for Multiple Switch Topology
00354cfb 82
6224e01d
AK
8312. Configuring Bonding for Maximum Throughput
8412.1 Maximum Throughput in a Single Switch Topology
8512.1.1 MT Bonding Mode Selection for Single Switch Topology
8612.1.2 MT Link Monitoring for Single Switch Topology
8712.2 Maximum Throughput in a Multiple Switch Topology
8812.2.1 MT Bonding Mode Selection for Multiple Switch Topology
8912.2.2 MT Link Monitoring for Multiple Switch Topology
1da177e4 90
6224e01d
AK
9113. Switch Behavior Issues
9213.1 Link Establishment and Failover Delays
9313.2 Duplicated Incoming Packets
1da177e4 94
6224e01d
AK
9514. Hardware Specific Considerations
9614.1 IBM BladeCenter
1da177e4 97
6224e01d 9815. Frequently Asked Questions
00354cfb 99
6224e01d 10016. Resources and Links
1da177e4
LT
101
102
1031. Bonding Driver Installation
104==============================
105
106 Most popular distro kernels ship with the bonding driver
b1098bbe 107already available as a module. If your distro does not, or you
1da177e4
LT
108have need to compile bonding from source (e.g., configuring and
109installing a mainline kernel from kernel.org), you'll need to perform
110the following steps:
111
1121.1 Configure and build the kernel with bonding
113-----------------------------------------------
114
00354cfb 115 The current version of the bonding driver is available in the
1da177e4 116drivers/net/bonding subdirectory of the most recent kernel source
00354cfb
JV
117(which is available on http://kernel.org). Most users "rolling their
118own" will want to use the most recent kernel from kernel.org.
1da177e4
LT
119
120 Configure kernel with "make menuconfig" (or "make xconfig" or
121"make config"), then select "Bonding driver support" in the "Network
122device support" section. It is recommended that you configure the
123driver as module since it is currently the only way to pass parameters
124to the driver or configure more than one bonding device.
125
b1098bbe 126 Build and install the new kernel and modules.
1da177e4 127
b1098bbe 1281.2 Bonding Control Utility
1da177e4
LT
129-------------------------------------
130
b1098bbe
CW
131 It is recommended to configure bonding via iproute2 (netlink)
132or sysfs, the old ifenslave control utility is obsolete.
1da177e4
LT
133
1342. Bonding Driver Options
135=========================
136
9a6c6867
JV
137 Options for the bonding driver are supplied as parameters to the
138bonding module at load time, or are specified via sysfs.
139
140 Module options may be given as command line arguments to the
141insmod or modprobe command, but are usually specified in either the
970e2486
LDM
142/etc/modrobe.d/*.conf configuration files, or in a distro-specific
143configuration file (some of which are detailed in the next section).
9a6c6867
JV
144
145 Details on bonding support for sysfs is provided in the
146"Configuring Bonding Manually via Sysfs" section, below.
1da177e4
LT
147
148 The available bonding driver parameters are listed below. If a
149parameter is not specified the default value is used. When initially
150configuring a bond, it is recommended "tail -f /var/log/messages" be
151run in a separate window to watch for bonding driver error messages.
152
153 It is critical that either the miimon or arp_interval and
154arp_ip_target parameters be specified, otherwise serious network
155degradation will occur during link failures. Very few devices do not
156support at least miimon, so there is really no reason not to use it.
157
158 Options with textual values will accept either the text name
00354cfb
JV
159or, for backwards compatibility, the option value. E.g.,
160"mode=802.3ad" and "mode=4" set the same mode.
1da177e4
LT
161
162 The parameters are as follows:
163
1ba9ac7c
NP
164active_slave
165
166 Specifies the new active slave for modes that support it
167 (active-backup, balance-alb and balance-tlb). Possible values
168 are the name of any currently enslaved interface, or an empty
169 string. If a name is given, the slave and its link must be up in order
170 to be selected as the new active slave. If an empty string is
171 specified, the current active slave is cleared, and a new active
172 slave is selected automatically.
173
174 Note that this is only available through the sysfs interface. No module
175 parameter by this name exists.
176
177 The normal value of this option is the name of the currently
178 active slave, or the empty string if there is no active slave or
179 the current mode does not use an active slave.
180
fd989c83
JV
181ad_select
182
183 Specifies the 802.3ad aggregation selection logic to use. The
184 possible values and their effects are:
185
186 stable or 0
187
188 The active aggregator is chosen by largest aggregate
189 bandwidth.
190
191 Reselection of the active aggregator occurs only when all
192 slaves of the active aggregator are down or the active
193 aggregator has no slaves.
194
195 This is the default value.
196
197 bandwidth or 1
198
199 The active aggregator is chosen by largest aggregate
200 bandwidth. Reselection occurs if:
201
202 - A slave is added to or removed from the bond
203
204 - Any slave's link state changes
205
206 - Any slave's 802.3ad association state changes
207
19f59460 208 - The bond's administrative state changes to up
fd989c83
JV
209
210 count or 2
211
212 The active aggregator is chosen by the largest number of
213 ports (slaves). Reselection occurs as described under the
214 "bandwidth" setting, above.
215
216 The bandwidth and count selection policies permit failover of
217 802.3ad aggregations when partial failure of the active aggregator
218 occurs. This keeps the aggregator with the highest availability
219 (either in bandwidth or in number of ports) active at all times.
220
221 This option was added in bonding version 3.4.0.
222
025890b4
NP
223all_slaves_active
224
225 Specifies that duplicate frames (received on inactive ports) should be
226 dropped (0) or delivered (1).
227
228 Normally, bonding will drop duplicate frames (received on inactive
229 ports), which is desirable for most users. But there are some times
230 it is nice to allow duplicate frames to be delivered.
231
232 The default value is 0 (drop duplicate frames received on inactive
233 ports).
234
1da177e4
LT
235arp_interval
236
00354cfb 237 Specifies the ARP link monitoring frequency in milliseconds.
f5b2b966
JV
238
239 The ARP monitor works by periodically checking the slave
240 devices to determine whether they have sent or received
241 traffic recently (the precise criteria depends upon the
242 bonding mode, and the state of the slave). Regular traffic is
243 generated via ARP probes issued for the addresses specified by
244 the arp_ip_target option.
245
246 This behavior can be modified by the arp_validate option,
247 below.
248
00354cfb
JV
249 If ARP monitoring is used in an etherchannel compatible mode
250 (modes 0 and 2), the switch should be configured in a mode
251 that evenly distributes packets across all links. If the
252 switch is configured to distribute the packets in an XOR
1da177e4
LT
253 fashion, all replies from the ARP targets will be received on
254 the same link which could cause the other team members to
00354cfb
JV
255 fail. ARP monitoring should not be used in conjunction with
256 miimon. A value of 0 disables ARP monitoring. The default
1da177e4
LT
257 value is 0.
258
259arp_ip_target
260
00354cfb
JV
261 Specifies the IP addresses to use as ARP monitoring peers when
262 arp_interval is > 0. These are the targets of the ARP request
263 sent to determine the health of the link to the targets.
264 Specify these values in ddd.ddd.ddd.ddd format. Multiple IP
265 addresses must be separated by a comma. At least one IP
266 address must be given for ARP monitoring to function. The
267 maximum number of targets that can be specified is 16. The
268 default value is no IP addresses.
1da177e4 269
f5b2b966
JV
270arp_validate
271
272 Specifies whether or not ARP probes and replies should be
273 validated in the active-backup mode. This causes the ARP
274 monitor to examine the incoming ARP requests and replies, and
275 only consider a slave to be up if it is receiving the
276 appropriate ARP traffic.
277
278 Possible values are:
279
280 none or 0
281
282 No validation is performed. This is the default.
283
284 active or 1
285
286 Validation is performed only for the active slave.
287
288 backup or 2
289
290 Validation is performed only for backup slaves.
291
292 all or 3
293
294 Validation is performed for all slaves.
295
296 For the active slave, the validation checks ARP replies to
297 confirm that they were generated by an arp_ip_target. Since
298 backup slaves do not typically receive these replies, the
299 validation performed for backup slaves is on the ARP request
300 sent out via the active slave. It is possible that some
301 switch or network configurations may result in situations
302 wherein the backup slaves do not receive the ARP requests; in
303 such a situation, validation of backup slaves must be
304 disabled.
305
d7d35c68
VF
306 The validation of ARP requests on backup slaves is mainly
307 helping bonding to decide which slaves are more likely to
308 work in case of the active slave failure, it doesn't really
309 guarantee that the backup slave will work if it's selected
310 as the next active slave.
311
f5b2b966
JV
312 This option is useful in network configurations in which
313 multiple bonding hosts are concurrently issuing ARPs to one or
314 more targets beyond a common switch. Should the link between
315 the switch and target fail (but not the switch itself), the
316 probe traffic generated by the multiple bonding instances will
317 fool the standard ARP monitor into considering the links as
318 still up. Use of the arp_validate option can resolve this, as
319 the ARP monitor will only consider ARP requests and replies
320 associated with its own instance of bonding.
321
322 This option was added in bonding version 3.1.0.
323
8599b52e
VF
324arp_all_targets
325
326 Specifies the quantity of arp_ip_targets that must be reachable
327 in order for the ARP monitor to consider a slave as being up.
328 This option affects only active-backup mode for slaves with
329 arp_validation enabled.
330
331 Possible values are:
332
333 any or 0
334
335 consider the slave up only when any of the arp_ip_targets
336 is reachable
337
338 all or 1
339
340 consider the slave up only when all of the arp_ip_targets
341 are reachable
342
1da177e4
LT
343downdelay
344
345 Specifies the time, in milliseconds, to wait before disabling
346 a slave after a link failure has been detected. This option
347 is only valid for the miimon link monitor. The downdelay
348 value should be a multiple of the miimon value; if not, it
349 will be rounded down to the nearest multiple. The default
350 value is 0.
351
dd957c57
JV
352fail_over_mac
353
354 Specifies whether active-backup mode should set all slaves to
3915c1e8
JV
355 the same MAC address at enslavement (the traditional
356 behavior), or, when enabled, perform special handling of the
357 bond's MAC address in accordance with the selected policy.
358
359 Possible values are:
360
361 none or 0
362
363 This setting disables fail_over_mac, and causes
364 bonding to set all slaves of an active-backup bond to
365 the same MAC address at enslavement time. This is the
366 default.
367
368 active or 1
369
370 The "active" fail_over_mac policy indicates that the
371 MAC address of the bond should always be the MAC
372 address of the currently active slave. The MAC
373 address of the slaves is not changed; instead, the MAC
374 address of the bond changes during a failover.
375
376 This policy is useful for devices that cannot ever
377 alter their MAC address, or for devices that refuse
378 incoming broadcasts with their own source MAC (which
379 interferes with the ARP monitor).
380
381 The down side of this policy is that every device on
382 the network must be updated via gratuitous ARP,
383 vs. just updating a switch or set of switches (which
384 often takes place for any traffic, not just ARP
385 traffic, if the switch snoops incoming traffic to
386 update its tables) for the traditional method. If the
387 gratuitous ARP is lost, communication may be
388 disrupted.
389
25985edc 390 When this policy is used in conjunction with the mii
3915c1e8
JV
391 monitor, devices which assert link up prior to being
392 able to actually transmit and receive are particularly
19f59460 393 susceptible to loss of the gratuitous ARP, and an
3915c1e8
JV
394 appropriate updelay setting may be required.
395
396 follow or 2
397
398 The "follow" fail_over_mac policy causes the MAC
399 address of the bond to be selected normally (normally
400 the MAC address of the first slave added to the bond).
401 However, the second and subsequent slaves are not set
402 to this MAC address while they are in a backup role; a
403 slave is programmed with the bond's MAC address at
404 failover time (and the formerly active slave receives
405 the newly active slave's MAC address).
406
407 This policy is useful for multiport devices that
408 either become confused or incur a performance penalty
409 when multiple ports are programmed with the same MAC
410 address.
411
412
413 The default policy is none, unless the first slave cannot
414 change its MAC address, in which case the active policy is
415 selected by default.
416
417 This option may be modified via sysfs only when no slaves are
418 present in the bond.
419
420 This option was added in bonding version 3.2.0. The "follow"
421 policy was added in bonding version 3.3.0.
dd957c57 422
1da177e4
LT
423lacp_rate
424
425 Option specifying the rate in which we'll ask our link partner
426 to transmit LACPDU packets in 802.3ad mode. Possible values
427 are:
428
429 slow or 0
00354cfb 430 Request partner to transmit LACPDUs every 30 seconds
1da177e4
LT
431
432 fast or 1
433 Request partner to transmit LACPDUs every 1 second
434
00354cfb
JV
435 The default is slow.
436
1da177e4
LT
437max_bonds
438
439 Specifies the number of bonding devices to create for this
440 instance of the bonding driver. E.g., if max_bonds is 3, and
441 the bonding driver is not already loaded, then bond0, bond1
b8a9787e
JV
442 and bond2 will be created. The default value is 1. Specifying
443 a value of 0 will load bonding, but will not create any devices.
1da177e4
LT
444
445miimon
446
00354cfb
JV
447 Specifies the MII link monitoring frequency in milliseconds.
448 This determines how often the link state of each slave is
449 inspected for link failures. A value of zero disables MII
450 link monitoring. A value of 100 is a good starting point.
451 The use_carrier option, below, affects how the link state is
1da177e4
LT
452 determined. See the High Availability section for additional
453 information. The default value is 0.
454
025890b4
NP
455min_links
456
457 Specifies the minimum number of links that must be active before
458 asserting carrier. It is similar to the Cisco EtherChannel min-links
459 feature. This allows setting the minimum number of member ports that
460 must be up (link-up state) before marking the bond device as up
461 (carrier on). This is useful for situations where higher level services
462 such as clustering want to ensure a minimum number of low bandwidth
463 links are active before switchover. This option only affect 802.3ad
464 mode.
465
466 The default value is 0. This will cause carrier to be asserted (for
467 802.3ad mode) whenever there is an active aggregator, regardless of the
468 number of available links in that aggregator. Note that, because an
469 aggregator cannot be active without at least one available link,
470 setting this option to 0 or to 1 has the exact same effect.
471
1da177e4
LT
472mode
473
474 Specifies one of the bonding policies. The default is
475 balance-rr (round robin). Possible values are:
476
477 balance-rr or 0
478
479 Round-robin policy: Transmit packets in sequential
480 order from the first available slave through the
481 last. This mode provides load balancing and fault
482 tolerance.
483
484 active-backup or 1
485
486 Active-backup policy: Only one slave in the bond is
487 active. A different slave becomes active if, and only
488 if, the active slave fails. The bond's MAC address is
489 externally visible on only one port (network adapter)
00354cfb
JV
490 to avoid confusing the switch.
491
492 In bonding version 2.6.2 or later, when a failover
493 occurs in active-backup mode, bonding will issue one
494 or more gratuitous ARPs on the newly active slave.
6224e01d 495 One gratuitous ARP is issued for the bonding master
00354cfb
JV
496 interface and each VLAN interfaces configured above
497 it, provided that the interface has at least one IP
498 address configured. Gratuitous ARPs issued for VLAN
499 interfaces are tagged with the appropriate VLAN id.
500
501 This mode provides fault tolerance. The primary
502 option, documented below, affects the behavior of this
503 mode.
1da177e4
LT
504
505 balance-xor or 2
506
00354cfb
JV
507 XOR policy: Transmit based on the selected transmit
508 hash policy. The default policy is a simple [(source
509 MAC address XOR'd with destination MAC address) modulo
510 slave count]. Alternate transmit policies may be
511 selected via the xmit_hash_policy option, described
512 below.
513
514 This mode provides load balancing and fault tolerance.
1da177e4
LT
515
516 broadcast or 3
517
518 Broadcast policy: transmits everything on all slave
519 interfaces. This mode provides fault tolerance.
520
521 802.3ad or 4
522
523 IEEE 802.3ad Dynamic link aggregation. Creates
524 aggregation groups that share the same speed and
525 duplex settings. Utilizes all slaves in the active
526 aggregator according to the 802.3ad specification.
527
00354cfb
JV
528 Slave selection for outgoing traffic is done according
529 to the transmit hash policy, which may be changed from
530 the default simple XOR policy via the xmit_hash_policy
531 option, documented below. Note that not all transmit
532 policies may be 802.3ad compliant, particularly in
533 regards to the packet mis-ordering requirements of
534 section 43.2.4 of the 802.3ad standard. Differing
535 peer implementations will have varying tolerances for
536 noncompliance.
537
538 Prerequisites:
1da177e4
LT
539
540 1. Ethtool support in the base drivers for retrieving
541 the speed and duplex of each slave.
542
543 2. A switch that supports IEEE 802.3ad Dynamic link
544 aggregation.
545
546 Most switches will require some type of configuration
547 to enable 802.3ad mode.
548
549 balance-tlb or 5
550
551 Adaptive transmit load balancing: channel bonding that
552 does not require any special switch support. The
553 outgoing traffic is distributed according to the
554 current load (computed relative to the speed) on each
555 slave. Incoming traffic is received by the current
556 slave. If the receiving slave fails, another slave
557 takes over the MAC address of the failed receiving
558 slave.
559
560 Prerequisite:
561
562 Ethtool support in the base drivers for retrieving the
563 speed of each slave.
564
565 balance-alb or 6
566
567 Adaptive load balancing: includes balance-tlb plus
568 receive load balancing (rlb) for IPV4 traffic, and
569 does not require any special switch support. The
570 receive load balancing is achieved by ARP negotiation.
571 The bonding driver intercepts the ARP Replies sent by
572 the local system on their way out and overwrites the
573 source hardware address with the unique hardware
574 address of one of the slaves in the bond such that
575 different peers use different hardware addresses for
576 the server.
577
578 Receive traffic from connections created by the server
579 is also balanced. When the local system sends an ARP
580 Request the bonding driver copies and saves the peer's
581 IP information from the ARP packet. When the ARP
582 Reply arrives from the peer, its hardware address is
583 retrieved and the bonding driver initiates an ARP
584 reply to this peer assigning it to one of the slaves
585 in the bond. A problematic outcome of using ARP
586 negotiation for balancing is that each time that an
587 ARP request is broadcast it uses the hardware address
588 of the bond. Hence, peers learn the hardware address
589 of the bond and the balancing of receive traffic
590 collapses to the current slave. This is handled by
591 sending updates (ARP Replies) to all the peers with
592 their individually assigned hardware address such that
593 the traffic is redistributed. Receive traffic is also
594 redistributed when a new slave is added to the bond
595 and when an inactive slave is re-activated. The
596 receive load is distributed sequentially (round robin)
597 among the group of highest speed slaves in the bond.
598
599 When a link is reconnected or a new slave joins the
600 bond the receive traffic is redistributed among all
00354cfb 601 active slaves in the bond by initiating ARP Replies
6224e01d 602 with the selected MAC address to each of the
1da177e4
LT
603 clients. The updelay parameter (detailed below) must
604 be set to a value equal or greater than the switch's
605 forwarding delay so that the ARP Replies sent to the
606 peers will not be blocked by the switch.
607
608 Prerequisites:
609
610 1. Ethtool support in the base drivers for retrieving
611 the speed of each slave.
612
613 2. Base driver support for setting the hardware
614 address of a device while it is open. This is
615 required so that there will always be one slave in the
616 team using the bond hardware address (the
617 curr_active_slave) while having a unique hardware
618 address for each slave in the bond. If the
619 curr_active_slave fails its hardware address is
620 swapped with the new curr_active_slave that was
621 chosen.
622
b59f9f74 623num_grat_arp
305d552a
BH
624num_unsol_na
625
ad246c99
BH
626 Specify the number of peer notifications (gratuitous ARPs and
627 unsolicited IPv6 Neighbor Advertisements) to be issued after a
628 failover event. As soon as the link is up on the new slave
629 (possibly immediately) a peer notification is sent on the
630 bonding device and each VLAN sub-device. This is repeated at
631 each link monitor interval (arp_interval or miimon, whichever
632 is active) if the number is greater than 1.
633
634 The valid range is 0 - 255; the default value is 1. These options
635 affect only the active-backup mode. These options were added for
636 bonding versions 3.3.0 and 3.4.0 respectively.
637
8fb4e139 638 From Linux 3.0 and bonding version 3.7.1, these notifications
ad246c99
BH
639 are generated by the ipv4 and ipv6 code and the numbers of
640 repetitions cannot be set independently.
305d552a 641
1da177e4
LT
642primary
643
644 A string (eth0, eth2, etc) specifying which slave is the
645 primary device. The specified device will always be the
646 active slave while it is available. Only when the primary is
647 off-line will alternate devices be used. This is useful when
648 one slave is preferred over another, e.g., when one slave has
649 higher throughput than another.
650
651 The primary option is only valid for active-backup mode.
652
a549952a
JP
653primary_reselect
654
655 Specifies the reselection policy for the primary slave. This
656 affects how the primary slave is chosen to become the active slave
657 when failure of the active slave or recovery of the primary slave
658 occurs. This option is designed to prevent flip-flopping between
659 the primary slave and other slaves. Possible values are:
660
661 always or 0 (default)
662
663 The primary slave becomes the active slave whenever it
664 comes back up.
665
666 better or 1
667
668 The primary slave becomes the active slave when it comes
669 back up, if the speed and duplex of the primary slave is
670 better than the speed and duplex of the current active
671 slave.
672
673 failure or 2
674
675 The primary slave becomes the active slave only if the
676 current active slave fails and the primary slave is up.
677
678 The primary_reselect setting is ignored in two cases:
679
680 If no slaves are active, the first slave to recover is
681 made the active slave.
682
683 When initially enslaved, the primary slave is always made
684 the active slave.
685
686 Changing the primary_reselect policy via sysfs will cause an
687 immediate selection of the best active slave according to the new
688 policy. This may or may not result in a change of the active
689 slave, depending upon the circumstances.
690
691 This option was added for bonding version 3.6.0.
692
1da177e4
LT
693updelay
694
695 Specifies the time, in milliseconds, to wait before enabling a
696 slave after a link recovery has been detected. This option is
697 only valid for the miimon link monitor. The updelay value
698 should be a multiple of the miimon value; if not, it will be
699 rounded down to the nearest multiple. The default value is 0.
700
701use_carrier
702
703 Specifies whether or not miimon should use MII or ETHTOOL
704 ioctls vs. netif_carrier_ok() to determine the link
705 status. The MII or ETHTOOL ioctls are less efficient and
706 utilize a deprecated calling sequence within the kernel. The
707 netif_carrier_ok() relies on the device driver to maintain its
708 state with netif_carrier_on/off; at this writing, most, but
709 not all, device drivers support this facility.
710
711 If bonding insists that the link is up when it should not be,
712 it may be that your network device driver does not support
713 netif_carrier_on/off. The default state for netif_carrier is
714 "carrier on," so if a driver does not support netif_carrier,
715 it will appear as if the link is always up. In this case,
716 setting use_carrier to 0 will cause bonding to revert to the
717 MII / ETHTOOL ioctl method to determine the link state.
718
719 A value of 1 enables the use of netif_carrier_ok(), a value of
720 0 will use the deprecated MII / ETHTOOL ioctls. The default
721 value is 1.
722
00354cfb
JV
723xmit_hash_policy
724
725 Selects the transmit hash policy to use for slave selection in
726 balance-xor and 802.3ad modes. Possible values are:
727
728 layer2
729
730 Uses XOR of hardware MAC addresses to generate the
731 hash. The formula is
732
733 (source MAC XOR destination MAC) modulo slave count
734
735 This algorithm will place all traffic to a particular
736 network peer on the same slave.
737
738 This algorithm is 802.3ad compliant.
739
6f6652be
JV
740 layer2+3
741
742 This policy uses a combination of layer2 and layer3
743 protocol information to generate the hash.
744
745 Uses XOR of hardware MAC addresses and IP addresses to
6b923cb7 746 generate the hash. The IPv4 formula is
6f6652be
JV
747
748 (((source IP XOR dest IP) AND 0xffff) XOR
749 ( source MAC XOR destination MAC ))
750 modulo slave count
751
6b923cb7
JE
752 The IPv6 formula is
753
754 hash = (source ip quad 2 XOR dest IP quad 2) XOR
755 (source ip quad 3 XOR dest IP quad 3) XOR
756 (source ip quad 4 XOR dest IP quad 4)
757
758 (((hash >> 24) XOR (hash >> 16) XOR (hash >> 8) XOR hash)
759 XOR (source MAC XOR destination MAC))
760 modulo slave count
761
6f6652be
JV
762 This algorithm will place all traffic to a particular
763 network peer on the same slave. For non-IP traffic,
764 the formula is the same as for the layer2 transmit
765 hash policy.
766
767 This policy is intended to provide a more balanced
768 distribution of traffic than layer2 alone, especially
769 in environments where a layer3 gateway device is
770 required to reach most destinations.
771
d9195881 772 This algorithm is 802.3ad compliant.
6f6652be 773
00354cfb
JV
774 layer3+4
775
776 This policy uses upper layer protocol information,
777 when available, to generate the hash. This allows for
778 traffic to a particular network peer to span multiple
779 slaves, although a single connection will not span
780 multiple slaves.
781
6b923cb7 782 The formula for unfragmented IPv4 TCP and UDP packets is
00354cfb
JV
783
784 ((source port XOR dest port) XOR
785 ((source IP XOR dest IP) AND 0xffff)
786 modulo slave count
787
6b923cb7
JE
788 The formula for unfragmented IPv6 TCP and UDP packets is
789
790 hash = (source port XOR dest port) XOR
791 ((source ip quad 2 XOR dest IP quad 2) XOR
792 (source ip quad 3 XOR dest IP quad 3) XOR
793 (source ip quad 4 XOR dest IP quad 4))
794
795 ((hash >> 24) XOR (hash >> 16) XOR (hash >> 8) XOR hash)
796 modulo slave count
797
798 For fragmented TCP or UDP packets and all other IPv4 and
799 IPv6 protocol traffic, the source and destination port
00354cfb
JV
800 information is omitted. For non-IP traffic, the
801 formula is the same as for the layer2 transmit hash
802 policy.
803
6b923cb7 804 The IPv4 policy is intended to mimic the behavior of
00354cfb
JV
805 certain switches, notably Cisco switches with PFC2 as
806 well as some Foundry and IBM products.
807
808 This algorithm is not fully 802.3ad compliant. A
809 single TCP or UDP conversation containing both
810 fragmented and unfragmented packets will see packets
811 striped across two interfaces. This may result in out
812 of order delivery. Most traffic types will not meet
813 this criteria, as TCP rarely fragments traffic, and
814 most UDP traffic is not involved in extended
815 conversations. Other implementations of 802.3ad may
816 or may not tolerate this noncompliance.
817
818 The default value is layer2. This option was added in bonding
6f6652be
JV
819 version 2.6.3. In earlier versions of bonding, this parameter
820 does not exist, and the layer2 policy is the only policy. The
821 layer2+3 value was added for bonding version 3.2.2.
1da177e4 822
c2952c31
FL
823resend_igmp
824
825 Specifies the number of IGMP membership reports to be issued after
826 a failover event. One membership report is issued immediately after
827 the failover, subsequent packets are sent in each 200ms interval.
828
94265cf5
FL
829 The valid range is 0 - 255; the default value is 1. A value of 0
830 prevents the IGMP membership report from being issued in response
831 to the failover event.
832
833 This option is useful for bonding modes balance-rr (0), active-backup
834 (1), balance-tlb (5) and balance-alb (6), in which a failover can
835 switch the IGMP traffic from one slave to another. Therefore a fresh
836 IGMP report must be issued to cause the switch to forward the incoming
837 IGMP traffic over the newly selected slave.
838
839 This option was added for bonding version 3.7.0.
1da177e4
LT
840
8413. Configuring Bonding Devices
842==============================
843
6224e01d 844 You can configure bonding using either your distro's network
b1098bbe 845initialization scripts, or manually using either iproute2 or the
de221bd5
NP
846sysfs interface. Distros generally use one of three packages for the
847network initialization scripts: initscripts, sysconfig or interfaces.
848Recent versions of these packages have support for bonding, while older
6224e01d 849versions do not.
1da177e4
LT
850
851 We will first describe the options for configuring bonding for
de221bd5
NP
852distros using versions of initscripts, sysconfig and interfaces with full
853or partial support for bonding, then provide information on enabling
1da177e4
LT
854bonding without support from the network initialization scripts (i.e.,
855older versions of initscripts or sysconfig).
856
de221bd5
NP
857 If you're unsure whether your distro uses sysconfig,
858initscripts or interfaces, or don't know if it's new enough, have no fear.
1da177e4
LT
859Determining this is fairly straightforward.
860
de221bd5
NP
861 First, look for a file called interfaces in /etc/network directory.
862If this file is present in your system, then your system use interfaces. See
863Configuration with Interfaces Support.
864
865 Else, issue the command:
1da177e4
LT
866
867$ rpm -qf /sbin/ifup
868
869 It will respond with a line of text starting with either
870"initscripts" or "sysconfig," followed by some numbers. This is the
871package that provides your network initialization scripts.
872
873 Next, to determine if your installation supports bonding,
874issue the command:
875
876$ grep ifenslave /sbin/ifup
877
878 If this returns any matches, then your initscripts or
879sysconfig has support for bonding.
880
6224e01d 8813.1 Configuration with Sysconfig Support
1da177e4
LT
882----------------------------------------
883
884 This section applies to distros using a version of sysconfig
885with bonding support, for example, SuSE Linux Enterprise Server 9.
886
887 SuSE SLES 9's networking configuration system does support
888bonding, however, at this writing, the YaST system configuration
6224e01d 889front end does not provide any means to work with bonding devices.
1da177e4
LT
890Bonding devices can be managed by hand, however, as follows.
891
892 First, if they have not already been configured, configure the
893slave devices. On SLES 9, this is most easily done by running the
894yast2 sysconfig configuration utility. The goal is for to create an
895ifcfg-id file for each slave device. The simplest way to accomplish
00354cfb
JV
896this is to configure the devices for DHCP (this is only to get the
897file ifcfg-id file created; see below for some issues with DHCP). The
898name of the configuration file for each device will be of the form:
1da177e4
LT
899
900ifcfg-id-xx:xx:xx:xx:xx:xx
901
902 Where the "xx" portion will be replaced with the digits from
903the device's permanent MAC address.
904
905 Once the set of ifcfg-id-xx:xx:xx:xx:xx:xx files has been
906created, it is necessary to edit the configuration files for the slave
907devices (the MAC addresses correspond to those of the slave devices).
00354cfb 908Before editing, the file will contain multiple lines, and will look
1da177e4
LT
909something like this:
910
911BOOTPROTO='dhcp'
912STARTMODE='on'
913USERCTL='no'
914UNIQUE='XNzu.WeZGOGF+4wE'
915_nm_name='bus-pci-0001:61:01.0'
916
917 Change the BOOTPROTO and STARTMODE lines to the following:
918
919BOOTPROTO='none'
920STARTMODE='off'
921
922 Do not alter the UNIQUE or _nm_name lines. Remove any other
923lines (USERCTL, etc).
924
925 Once the ifcfg-id-xx:xx:xx:xx:xx:xx files have been modified,
926it's time to create the configuration file for the bonding device
927itself. This file is named ifcfg-bondX, where X is the number of the
928bonding device to create, starting at 0. The first such file is
929ifcfg-bond0, the second is ifcfg-bond1, and so on. The sysconfig
930network configuration system will correctly start multiple instances
931of bonding.
932
933 The contents of the ifcfg-bondX file is as follows:
934
935BOOTPROTO="static"
936BROADCAST="10.0.2.255"
937IPADDR="10.0.2.10"
938NETMASK="255.255.0.0"
939NETWORK="10.0.2.0"
940REMOTE_IPADDR=""
941STARTMODE="onboot"
942BONDING_MASTER="yes"
943BONDING_MODULE_OPTS="mode=active-backup miimon=100"
944BONDING_SLAVE0="eth0"
00354cfb 945BONDING_SLAVE1="bus-pci-0000:06:08.1"
1da177e4
LT
946
947 Replace the sample BROADCAST, IPADDR, NETMASK and NETWORK
948values with the appropriate values for your network.
949
1da177e4
LT
950 The STARTMODE specifies when the device is brought online.
951The possible values are:
952
953 onboot: The device is started at boot time. If you're not
954 sure, this is probably what you want.
955
956 manual: The device is started only when ifup is called
957 manually. Bonding devices may be configured this
958 way if you do not wish them to start automatically
959 at boot for some reason.
960
961 hotplug: The device is started by a hotplug event. This is not
962 a valid choice for a bonding device.
963
964 off or ignore: The device configuration is ignored.
965
966 The line BONDING_MASTER='yes' indicates that the device is a
967bonding master device. The only useful value is "yes."
968
969 The contents of BONDING_MODULE_OPTS are supplied to the
970instance of the bonding module for this device. Specify the options
971for the bonding mode, link monitoring, and so on here. Do not include
972the max_bonds bonding parameter; this will confuse the configuration
973system if you have multiple bonding devices.
974
00354cfb
JV
975 Finally, supply one BONDING_SLAVEn="slave device" for each
976slave. where "n" is an increasing value, one for each slave. The
977"slave device" is either an interface name, e.g., "eth0", or a device
978specifier for the network device. The interface name is easier to
979find, but the ethN names are subject to change at boot time if, e.g.,
980a device early in the sequence has failed. The device specifiers
981(bus-pci-0000:06:08.1 in the example above) specify the physical
982network device, and will not change unless the device's bus location
983changes (for example, it is moved from one PCI slot to another). The
984example above uses one of each type for demonstration purposes; most
985configurations will choose one or the other for all slave devices.
1da177e4
LT
986
987 When all configuration files have been modified or created,
988networking must be restarted for the configuration changes to take
989effect. This can be accomplished via the following:
990
991# /etc/init.d/network restart
992
993 Note that the network control script (/sbin/ifdown) will
994remove the bonding module as part of the network shutdown processing,
995so it is not necessary to remove the module by hand if, e.g., the
00354cfb 996module parameters have changed.
1da177e4
LT
997
998 Also, at this writing, YaST/YaST2 will not manage bonding
999devices (they do not show bonding interfaces on its list of network
1000devices). It is necessary to edit the configuration file by hand to
1001change the bonding configuration.
1002
1003 Additional general options and details of the ifcfg file
1004format can be found in an example ifcfg template file:
1005
1006/etc/sysconfig/network/ifcfg.template
1007
1008 Note that the template does not document the various BONDING_
1009settings described above, but does describe many of the other options.
1010
6224e01d 10113.1.1 Using DHCP with Sysconfig
00354cfb
JV
1012-------------------------------
1013
1014 Under sysconfig, configuring a device with BOOTPROTO='dhcp'
1015will cause it to query DHCP for its IP address information. At this
1016writing, this does not function for bonding devices; the scripts
1017attempt to obtain the device address from DHCP prior to adding any of
1018the slave devices. Without active slaves, the DHCP requests are not
1019sent to the network.
1020
6224e01d 10213.1.2 Configuring Multiple Bonds with Sysconfig
00354cfb
JV
1022-----------------------------------------------
1023
1024 The sysconfig network initialization system is capable of
1025handling multiple bonding devices. All that is necessary is for each
1026bonding instance to have an appropriately configured ifcfg-bondX file
1027(as described above). Do not specify the "max_bonds" parameter to any
1028instance of bonding, as this will confuse sysconfig. If you require
1029multiple bonding devices with identical parameters, create multiple
1030ifcfg-bondX files.
1031
1032 Because the sysconfig scripts supply the bonding module
1033options in the ifcfg-bondX file, it is not necessary to add them to
970e2486 1034the system /etc/modules.d/*.conf configuration files.
00354cfb 1035
6224e01d 10363.2 Configuration with Initscripts Support
1da177e4
LT
1037------------------------------------------
1038
9a6c6867
JV
1039 This section applies to distros using a recent version of
1040initscripts with bonding support, for example, Red Hat Enterprise Linux
1041version 3 or later, Fedora, etc. On these systems, the network
1042initialization scripts have knowledge of bonding, and can be configured to
1043control bonding devices. Note that older versions of the initscripts
1044package have lower levels of support for bonding; this will be noted where
1045applicable.
1da177e4
LT
1046
1047 These distros will not automatically load the network adapter
1048driver unless the ethX device is configured with an IP address.
1049Because of this constraint, users must manually configure a
1050network-script file for all physical adapters that will be members of
1051a bondX link. Network script files are located in the directory:
1052
1053/etc/sysconfig/network-scripts
1054
1055 The file name must be prefixed with "ifcfg-eth" and suffixed
1056with the adapter's physical adapter number. For example, the script
1057for eth0 would be named /etc/sysconfig/network-scripts/ifcfg-eth0.
1058Place the following text in the file:
1059
1060DEVICE=eth0
1061USERCTL=no
1062ONBOOT=yes
1063MASTER=bond0
1064SLAVE=yes
1065BOOTPROTO=none
1066
1067 The DEVICE= line will be different for every ethX device and
1068must correspond with the name of the file, i.e., ifcfg-eth1 must have
1069a device line of DEVICE=eth1. The setting of the MASTER= line will
1070also depend on the final bonding interface name chosen for your bond.
1071As with other network devices, these typically start at 0, and go up
1072one for each device, i.e., the first bonding instance is bond0, the
1073second is bond1, and so on.
1074
1075 Next, create a bond network script. The file name for this
1076script will be /etc/sysconfig/network-scripts/ifcfg-bondX where X is
1077the number of the bond. For bond0 the file is named "ifcfg-bond0",
1078for bond1 it is named "ifcfg-bond1", and so on. Within that file,
1079place the following text:
1080
1081DEVICE=bond0
1082IPADDR=192.168.1.1
1083NETMASK=255.255.255.0
1084NETWORK=192.168.1.0
1085BROADCAST=192.168.1.255
1086ONBOOT=yes
1087BOOTPROTO=none
1088USERCTL=no
1089
1090 Be sure to change the networking specific lines (IPADDR,
1091NETMASK, NETWORK and BROADCAST) to match your network configuration.
1092
9a6c6867 1093 For later versions of initscripts, such as that found with Fedora
3f8b4b13
AG
10947 (or later) and Red Hat Enterprise Linux version 5 (or later), it is possible,
1095and, indeed, preferable, to specify the bonding options in the ifcfg-bond0
9a6c6867
JV
1096file, e.g. a line of the format:
1097
3f8b4b13 1098BONDING_OPTS="mode=active-backup arp_interval=60 arp_ip_target=192.168.1.254"
9a6c6867
JV
1099
1100 will configure the bond with the specified options. The options
1101specified in BONDING_OPTS are identical to the bonding module parameters
3f8b4b13
AG
1102except for the arp_ip_target field when using versions of initscripts older
1103than and 8.57 (Fedora 8) and 8.45.19 (Red Hat Enterprise Linux 5.2). When
1104using older versions each target should be included as a separate option and
1105should be preceded by a '+' to indicate it should be added to the list of
1106queried targets, e.g.,
9a6c6867
JV
1107
1108 arp_ip_target=+192.168.1.1 arp_ip_target=+192.168.1.2
1109
1110 is the proper syntax to specify multiple targets. When specifying
970e2486 1111options via BONDING_OPTS, it is not necessary to edit /etc/modprobe.d/*.conf.
9a6c6867 1112
3f8b4b13 1113 For even older versions of initscripts that do not support
970e2486
LDM
1114BONDING_OPTS, it is necessary to edit /etc/modprobe.d/*.conf, depending upon
1115your distro) to load the bonding module with your desired options when the
1116bond0 interface is brought up. The following lines in /etc/modprobe.d/*.conf
1117will load the bonding module, and select its options:
1da177e4
LT
1118
1119alias bond0 bonding
1120options bond0 mode=balance-alb miimon=100
1121
1122 Replace the sample parameters with the appropriate set of
1123options for your configuration.
1124
1125 Finally run "/etc/rc.d/init.d/network restart" as root. This
1126will restart the networking subsystem and your bond link should be now
1127up and running.
1128
6224e01d 11293.2.1 Using DHCP with Initscripts
00354cfb
JV
1130---------------------------------
1131
9a6c6867
JV
1132 Recent versions of initscripts (the versions supplied with Fedora
1133Core 3 and Red Hat Enterprise Linux 4, or later versions, are reported to
1134work) have support for assigning IP information to bonding devices via
1135DHCP.
00354cfb
JV
1136
1137 To configure bonding for DHCP, configure it as described
1138above, except replace the line "BOOTPROTO=none" with "BOOTPROTO=dhcp"
1139and add a line consisting of "TYPE=Bonding". Note that the TYPE value
1140is case sensitive.
1141
6224e01d 11423.2.2 Configuring Multiple Bonds with Initscripts
00354cfb
JV
1143-------------------------------------------------
1144
9a6c6867
JV
1145 Initscripts packages that are included with Fedora 7 and Red Hat
1146Enterprise Linux 5 support multiple bonding interfaces by simply
1147specifying the appropriate BONDING_OPTS= in ifcfg-bondX where X is the
1148number of the bond. This support requires sysfs support in the kernel,
1149and a bonding driver of version 3.0.0 or later. Other configurations may
1150not support this method for specifying multiple bonding interfaces; for
1151those instances, see the "Configuring Multiple Bonds Manually" section,
1152below.
1da177e4 1153
b1098bbe 11543.3 Configuring Bonding Manually with iproute2
6224e01d 1155-----------------------------------------------
1da177e4
LT
1156
1157 This section applies to distros whose network initialization
1158scripts (the sysconfig or initscripts package) do not have specific
1159knowledge of bonding. One such distro is SuSE Linux Enterprise Server
1160version 8.
1161
00354cfb 1162 The general method for these systems is to place the bonding
970e2486 1163module parameters into a config file in /etc/modprobe.d/ (as
00354cfb 1164appropriate for the installed distro), then add modprobe and/or
b1098bbe 1165`ip link` commands to the system's global init script. The name of
00354cfb 1166the global init script differs; for sysconfig, it is
1da177e4
LT
1167/etc/init.d/boot.local and for initscripts it is /etc/rc.d/rc.local.
1168
1169 For example, if you wanted to make a simple bond of two e100
1170devices (presumed to be eth0 and eth1), and have it persist across
1171reboots, edit the appropriate file (/etc/init.d/boot.local or
1172/etc/rc.d/rc.local), and add the following:
1173
00354cfb 1174modprobe bonding mode=balance-alb miimon=100
1da177e4
LT
1175modprobe e100
1176ifconfig bond0 192.168.1.1 netmask 255.255.255.0 up
b1098bbe
CW
1177ip link set eth0 master bond0
1178ip link set eth1 master bond0
1da177e4
LT
1179
1180 Replace the example bonding module parameters and bond0
1181network configuration (IP address, netmask, etc) with the appropriate
00354cfb 1182values for your configuration.
1da177e4
LT
1183
1184 Unfortunately, this method will not provide support for the
1185ifup and ifdown scripts on the bond devices. To reload the bonding
1186configuration, it is necessary to run the initialization script, e.g.,
1187
1188# /etc/init.d/boot.local
1189
1190 or
1191
1192# /etc/rc.d/rc.local
1193
1194 It may be desirable in such a case to create a separate script
1195which only initializes the bonding configuration, then call that
1196separate script from within boot.local. This allows for bonding to be
1197enabled without re-running the entire global init script.
1198
1199 To shut down the bonding devices, it is necessary to first
1200mark the bonding device itself as being down, then remove the
1201appropriate device driver modules. For our example above, you can do
1202the following:
1203
1204# ifconfig bond0 down
00354cfb 1205# rmmod bonding
1da177e4
LT
1206# rmmod e100
1207
1208 Again, for convenience, it may be desirable to create a script
1209with these commands.
1210
1211
00354cfb
JV
12123.3.1 Configuring Multiple Bonds Manually
1213-----------------------------------------
1da177e4
LT
1214
1215 This section contains information on configuring multiple
00354cfb
JV
1216bonding devices with differing options for those systems whose network
1217initialization scripts lack support for configuring multiple bonds.
1218
1219 If you require multiple bonding devices, but all with the same
1220options, you may wish to use the "max_bonds" module parameter,
1221documented above.
1da177e4 1222
9a6c6867 1223 To create multiple bonding devices with differing options, it is
f8b72d36 1224preferable to use bonding parameters exported by sysfs, documented in the
9a6c6867
JV
1225section below.
1226
1227 For versions of bonding without sysfs support, the only means to
1228provide multiple instances of bonding with differing options is to load
1229the bonding driver multiple times. Note that current versions of the
1230sysconfig network initialization scripts handle this automatically; if
1231your distro uses these scripts, no special action is needed. See the
1232section Configuring Bonding Devices, above, if you're not sure about your
1233network initialization scripts.
1234
1235 To load multiple instances of the module, it is necessary to
1236specify a different name for each instance (the module loading system
1237requires that every loaded module, even multiple instances of the same
1238module, have a unique name). This is accomplished by supplying multiple
970e2486 1239sets of bonding options in /etc/modprobe.d/*.conf, for example:
9a6c6867
JV
1240
1241alias bond0 bonding
1242options bond0 -o bond0 mode=balance-rr miimon=100
1243
1244alias bond1 bonding
1245options bond1 -o bond1 mode=balance-alb miimon=50
1246
1247 will load the bonding module two times. The first instance is
1248named "bond0" and creates the bond0 device in balance-rr mode with an
1249miimon of 100. The second instance is named "bond1" and creates the
1250bond1 device in balance-alb mode with an miimon of 50.
1251
1252 In some circumstances (typically with older distributions),
1253the above does not work, and the second bonding instance never sees
1254its options. In that case, the second options line can be substituted
1255as follows:
1256
1257install bond1 /sbin/modprobe --ignore-install bonding -o bond1 \
1258 mode=balance-alb miimon=50
00354cfb 1259
9a6c6867
JV
1260 This may be repeated any number of times, specifying a new and
1261unique name in place of bond1 for each subsequent instance.
1262
1263 It has been observed that some Red Hat supplied kernels are unable
1264to rename modules at load time (the "-o bond1" part). Attempts to pass
1265that option to modprobe will produce an "Operation not permitted" error.
1266This has been reported on some Fedora Core kernels, and has been seen on
1267RHEL 4 as well. On kernels exhibiting this problem, it will be impossible
1268to configure multiple bonds with differing parameters (as they are older
1269kernels, and also lack sysfs support).
1da177e4 1270
6224e01d
AK
12713.4 Configuring Bonding Manually via Sysfs
1272------------------------------------------
1273
9a6c6867 1274 Starting with version 3.0.0, Channel Bonding may be configured
6224e01d
AK
1275via the sysfs interface. This interface allows dynamic configuration
1276of all bonds in the system without unloading the module. It also
1277allows for adding and removing bonds at runtime. Ifenslave is no
1278longer required, though it is still supported.
1279
1280 Use of the sysfs interface allows you to use multiple bonds
1281with different configurations without having to reload the module.
1282It also allows you to use multiple, differently configured bonds when
1283bonding is compiled into the kernel.
1284
1285 You must have the sysfs filesystem mounted to configure
1286bonding this way. The examples in this document assume that you
1287are using the standard mount point for sysfs, e.g. /sys. If your
1288sysfs filesystem is mounted elsewhere, you will need to adjust the
1289example paths accordingly.
1290
1291Creating and Destroying Bonds
1292-----------------------------
1293To add a new bond foo:
1294# echo +foo > /sys/class/net/bonding_masters
1295
1296To remove an existing bond bar:
1297# echo -bar > /sys/class/net/bonding_masters
1298
1299To show all existing bonds:
1300# cat /sys/class/net/bonding_masters
1301
1302NOTE: due to 4K size limitation of sysfs files, this list may be
1303truncated if you have more than a few hundred bonds. This is unlikely
1304to occur under normal operating conditions.
1305
1306Adding and Removing Slaves
1307--------------------------
1308 Interfaces may be enslaved to a bond using the file
1309/sys/class/net/<bond>/bonding/slaves. The semantics for this file
1310are the same as for the bonding_masters file.
1311
1312To enslave interface eth0 to bond bond0:
1313# ifconfig bond0 up
1314# echo +eth0 > /sys/class/net/bond0/bonding/slaves
1315
1316To free slave eth0 from bond bond0:
1317# echo -eth0 > /sys/class/net/bond0/bonding/slaves
1318
6224e01d
AK
1319 When an interface is enslaved to a bond, symlinks between the
1320two are created in the sysfs filesystem. In this case, you would get
1321/sys/class/net/bond0/slave_eth0 pointing to /sys/class/net/eth0, and
1322/sys/class/net/eth0/master pointing to /sys/class/net/bond0.
1323
1324 This means that you can tell quickly whether or not an
1325interface is enslaved by looking for the master symlink. Thus:
1326# echo -eth0 > /sys/class/net/eth0/master/bonding/slaves
1327will free eth0 from whatever bond it is enslaved to, regardless of
1328the name of the bond interface.
1329
1330Changing a Bond's Configuration
1331-------------------------------
1332 Each bond may be configured individually by manipulating the
1333files located in /sys/class/net/<bond name>/bonding
1334
1335 The names of these files correspond directly with the command-
670e9f34 1336line parameters described elsewhere in this file, and, with the
6224e01d
AK
1337exception of arp_ip_target, they accept the same values. To see the
1338current setting, simply cat the appropriate file.
1339
1340 A few examples will be given here; for specific usage
1341guidelines for each parameter, see the appropriate section in this
1342document.
1343
1344To configure bond0 for balance-alb mode:
1345# ifconfig bond0 down
1346# echo 6 > /sys/class/net/bond0/bonding/mode
1347 - or -
1348# echo balance-alb > /sys/class/net/bond0/bonding/mode
1349 NOTE: The bond interface must be down before the mode can be
1350changed.
1351
1352To enable MII monitoring on bond0 with a 1 second interval:
1353# echo 1000 > /sys/class/net/bond0/bonding/miimon
1354 NOTE: If ARP monitoring is enabled, it will disabled when MII
1355monitoring is enabled, and vice-versa.
1356
1357To add ARP targets:
1358# echo +192.168.0.100 > /sys/class/net/bond0/bonding/arp_ip_target
1359# echo +192.168.0.101 > /sys/class/net/bond0/bonding/arp_ip_target
5a31bec0 1360 NOTE: up to 16 target addresses may be specified.
6224e01d
AK
1361
1362To remove an ARP target:
1363# echo -192.168.0.100 > /sys/class/net/bond0/bonding/arp_ip_target
1364
1365Example Configuration
1366---------------------
1367 We begin with the same example that is shown in section 3.3,
1368executed with sysfs, and without using ifenslave.
1369
1370 To make a simple bond of two e100 devices (presumed to be eth0
1371and eth1), and have it persist across reboots, edit the appropriate
1372file (/etc/init.d/boot.local or /etc/rc.d/rc.local), and add the
1373following:
1374
1375modprobe bonding
1376modprobe e100
1377echo balance-alb > /sys/class/net/bond0/bonding/mode
1378ifconfig bond0 192.168.1.1 netmask 255.255.255.0 up
1379echo 100 > /sys/class/net/bond0/bonding/miimon
1380echo +eth0 > /sys/class/net/bond0/bonding/slaves
1381echo +eth1 > /sys/class/net/bond0/bonding/slaves
1382
1383 To add a second bond, with two e1000 interfaces in
1384active-backup mode, using ARP monitoring, add the following lines to
1385your init script:
1386
1387modprobe e1000
1388echo +bond1 > /sys/class/net/bonding_masters
1389echo active-backup > /sys/class/net/bond1/bonding/mode
1390ifconfig bond1 192.168.2.1 netmask 255.255.255.0 up
1391echo +192.168.2.100 /sys/class/net/bond1/bonding/arp_ip_target
1392echo 2000 > /sys/class/net/bond1/bonding/arp_interval
1393echo +eth2 > /sys/class/net/bond1/bonding/slaves
1394echo +eth3 > /sys/class/net/bond1/bonding/slaves
1395
de221bd5
NP
13963.5 Configuration with Interfaces Support
1397-----------------------------------------
1398
1399 This section applies to distros which use /etc/network/interfaces file
1400to describe network interface configuration, most notably Debian and it's
1401derivatives.
1402
1403 The ifup and ifdown commands on Debian don't support bonding out of
1404the box. The ifenslave-2.6 package should be installed to provide bonding
1405support. Once installed, this package will provide bond-* options to be used
1406into /etc/network/interfaces.
1407
1408 Note that ifenslave-2.6 package will load the bonding module and use
1409the ifenslave command when appropriate.
1410
1411Example Configurations
1412----------------------
1413
1414In /etc/network/interfaces, the following stanza will configure bond0, in
1415active-backup mode, with eth0 and eth1 as slaves.
1416
1417auto bond0
1418iface bond0 inet dhcp
1419 bond-slaves eth0 eth1
1420 bond-mode active-backup
1421 bond-miimon 100
1422 bond-primary eth0 eth1
1423
1424If the above configuration doesn't work, you might have a system using
1425upstart for system startup. This is most notably true for recent
1426Ubuntu versions. The following stanza in /etc/network/interfaces will
1427produce the same result on those systems.
1428
1429auto bond0
1430iface bond0 inet dhcp
1431 bond-slaves none
1432 bond-mode active-backup
1433 bond-miimon 100
1434
1435auto eth0
1436iface eth0 inet manual
1437 bond-master bond0
1438 bond-primary eth0 eth1
1439
1440auto eth1
1441iface eth1 inet manual
1442 bond-master bond0
1443 bond-primary eth0 eth1
1444
1445For a full list of bond-* supported options in /etc/network/interfaces and some
1446more advanced examples tailored to you particular distros, see the files in
1447/usr/share/doc/ifenslave-2.6.
1448
14493.6 Overriding Configuration for Special Cases
bb1d9123 1450----------------------------------------------
de221bd5 1451
bb1d9123
AG
1452When using the bonding driver, the physical port which transmits a frame is
1453typically selected by the bonding driver, and is not relevant to the user or
1454system administrator. The output port is simply selected using the policies of
1455the selected bonding mode. On occasion however, it is helpful to direct certain
1456classes of traffic to certain physical interfaces on output to implement
1457slightly more complex policies. For example, to reach a web server over a
1458bonded interface in which eth0 connects to a private network, while eth1
1459connects via a public network, it may be desirous to bias the bond to send said
1460traffic over eth0 first, using eth1 only as a fall back, while all other traffic
1461can safely be sent over either interface. Such configurations may be achieved
1462using the traffic control utilities inherent in linux.
1463
1464By default the bonding driver is multiqueue aware and 16 queues are created
1465when the driver initializes (see Documentation/networking/multiqueue.txt
1466for details). If more or less queues are desired the module parameter
1467tx_queues can be used to change this value. There is no sysfs parameter
1468available as the allocation is done at module init time.
1469
1470The output of the file /proc/net/bonding/bondX has changed so the output Queue
1471ID is now printed for each slave:
1472
1473Bonding Mode: fault-tolerance (active-backup)
1474Primary Slave: None
1475Currently Active Slave: eth0
1476MII Status: up
1477MII Polling Interval (ms): 0
1478Up Delay (ms): 0
1479Down Delay (ms): 0
1480
1481Slave Interface: eth0
1482MII Status: up
1483Link Failure Count: 0
1484Permanent HW addr: 00:1a:a0:12:8f:cb
1485Slave queue ID: 0
1486
1487Slave Interface: eth1
1488MII Status: up
1489Link Failure Count: 0
1490Permanent HW addr: 00:1a:a0:12:8f:cc
1491Slave queue ID: 2
1492
1493The queue_id for a slave can be set using the command:
1494
1495# echo "eth1:2" > /sys/class/net/bond0/bonding/queue_id
1496
1497Any interface that needs a queue_id set should set it with multiple calls
1498like the one above until proper priorities are set for all interfaces. On
1499distributions that allow configuration via initscripts, multiple 'queue_id'
1500arguments can be added to BONDING_OPTS to set all needed slave queues.
1501
1502These queue id's can be used in conjunction with the tc utility to configure
1503a multiqueue qdisc and filters to bias certain traffic to transmit on certain
1504slave devices. For instance, say we wanted, in the above configuration to
1505force all traffic bound to 192.168.1.100 to use eth1 in the bond as its output
1506device. The following commands would accomplish this:
1507
1508# tc qdisc add dev bond0 handle 1 root multiq
1509
1510# tc filter add dev bond0 protocol ip parent 1: prio 1 u32 match ip dst \
1511 192.168.1.100 action skbedit queue_mapping 2
1512
1513These commands tell the kernel to attach a multiqueue queue discipline to the
1514bond0 interface and filter traffic enqueued to it, such that packets with a dst
1515ip of 192.168.1.100 have their output queue mapping value overwritten to 2.
1516This value is then passed into the driver, causing the normal output path
1517selection policy to be overridden, selecting instead qid 2, which maps to eth1.
1518
1519Note that qid values begin at 1. Qid 0 is reserved to initiate to the driver
1520that normal output policy selection should take place. One benefit to simply
1521leaving the qid for a slave to 0 is the multiqueue awareness in the bonding
1522driver that is now present. This awareness allows tc filters to be placed on
1523slave devices as well as bond devices and the bonding driver will simply act as
1524a pass-through for selecting output queues on the slave device rather than
1525output port selection.
1526
1527This feature first appeared in bonding driver version 3.7.0 and support for
1528output slave selection was limited to round-robin and active-backup modes.
1529
15304 Querying Bonding Configuration
1da177e4
LT
1531=================================
1532
6224e01d 15334.1 Bonding Configuration
1da177e4
LT
1534-------------------------
1535
1536 Each bonding device has a read-only file residing in the
1537/proc/net/bonding directory. The file contents include information
1538about the bonding configuration, options and state of each slave.
1539
1540 For example, the contents of /proc/net/bonding/bond0 after the
1541driver is loaded with parameters of mode=0 and miimon=1000 is
1542generally as follows:
1543
1544 Ethernet Channel Bonding Driver: 2.6.1 (October 29, 2004)
1545 Bonding Mode: load balancing (round-robin)
1546 Currently Active Slave: eth0
1547 MII Status: up
1548 MII Polling Interval (ms): 1000
1549 Up Delay (ms): 0
1550 Down Delay (ms): 0
1551
1552 Slave Interface: eth1
1553 MII Status: up
1554 Link Failure Count: 1
1555
1556 Slave Interface: eth0
1557 MII Status: up
1558 Link Failure Count: 1
1559
1560 The precise format and contents will change depending upon the
1561bonding configuration, state, and version of the bonding driver.
1562
6224e01d 15634.2 Network configuration
1da177e4
LT
1564-------------------------
1565
1566 The network configuration can be inspected using the ifconfig
1567command. Bonding devices will have the MASTER flag set; Bonding slave
1568devices will have the SLAVE flag set. The ifconfig output does not
1569contain information on which slaves are associated with which masters.
1570
1571 In the example below, the bond0 interface is the master
1572(MASTER) while eth0 and eth1 are slaves (SLAVE). Notice all slaves of
1573bond0 have the same MAC address (HWaddr) as bond0 for all modes except
1574TLB and ALB that require a unique MAC address for each slave.
1575
1576# /sbin/ifconfig
1577bond0 Link encap:Ethernet HWaddr 00:C0:F0:1F:37:B4
1578 inet addr:XXX.XXX.XXX.YYY Bcast:XXX.XXX.XXX.255 Mask:255.255.252.0
1579 UP BROADCAST RUNNING MASTER MULTICAST MTU:1500 Metric:1
1580 RX packets:7224794 errors:0 dropped:0 overruns:0 frame:0
1581 TX packets:3286647 errors:1 dropped:0 overruns:1 carrier:0
1582 collisions:0 txqueuelen:0
1583
1584eth0 Link encap:Ethernet HWaddr 00:C0:F0:1F:37:B4
1da177e4
LT
1585 UP BROADCAST RUNNING SLAVE MULTICAST MTU:1500 Metric:1
1586 RX packets:3573025 errors:0 dropped:0 overruns:0 frame:0
1587 TX packets:1643167 errors:1 dropped:0 overruns:1 carrier:0
1588 collisions:0 txqueuelen:100
1589 Interrupt:10 Base address:0x1080
1590
1591eth1 Link encap:Ethernet HWaddr 00:C0:F0:1F:37:B4
1da177e4
LT
1592 UP BROADCAST RUNNING SLAVE MULTICAST MTU:1500 Metric:1
1593 RX packets:3651769 errors:0 dropped:0 overruns:0 frame:0
1594 TX packets:1643480 errors:0 dropped:0 overruns:0 carrier:0
1595 collisions:0 txqueuelen:100
1596 Interrupt:9 Base address:0x1400
1597
6224e01d 15985. Switch Configuration
1da177e4
LT
1599=======================
1600
1601 For this section, "switch" refers to whatever system the
1602bonded devices are directly connected to (i.e., where the other end of
1603the cable plugs into). This may be an actual dedicated switch device,
1604or it may be another regular system (e.g., another computer running
1605Linux),
1606
1607 The active-backup, balance-tlb and balance-alb modes do not
1608require any specific configuration of the switch.
1609
1610 The 802.3ad mode requires that the switch have the appropriate
1611ports configured as an 802.3ad aggregation. The precise method used
1612to configure this varies from switch to switch, but, for example, a
1613Cisco 3550 series switch requires that the appropriate ports first be
1614grouped together in a single etherchannel instance, then that
1615etherchannel is set to mode "lacp" to enable 802.3ad (instead of
1616standard EtherChannel).
1617
1618 The balance-rr, balance-xor and broadcast modes generally
1619require that the switch have the appropriate ports grouped together.
1620The nomenclature for such a group differs between switches, it may be
1621called an "etherchannel" (as in the Cisco example, above), a "trunk
1622group" or some other similar variation. For these modes, each switch
1623will also have its own configuration options for the switch's transmit
1624policy to the bond. Typical choices include XOR of either the MAC or
1625IP addresses. The transmit policy of the two peers does not need to
1626match. For these three modes, the bonding mode really selects a
1627transmit policy for an EtherChannel group; all three will interoperate
1628with another EtherChannel group.
1629
1630
6224e01d 16316. 802.1q VLAN Support
1da177e4
LT
1632======================
1633
1634 It is possible to configure VLAN devices over a bond interface
1635using the 8021q driver. However, only packets coming from the 8021q
1636driver and passing through bonding will be tagged by default. Self
1637generated packets, for example, bonding's learning packets or ARP
1638packets generated by either ALB mode or the ARP monitor mechanism, are
1639tagged internally by bonding itself. As a result, bonding must
1640"learn" the VLAN IDs configured above it, and use those IDs to tag
1641self generated packets.
1642
1643 For reasons of simplicity, and to support the use of adapters
00354cfb
JV
1644that can do VLAN hardware acceleration offloading, the bonding
1645interface declares itself as fully hardware offloading capable, it gets
1da177e4
LT
1646the add_vid/kill_vid notifications to gather the necessary
1647information, and it propagates those actions to the slaves. In case
1648of mixed adapter types, hardware accelerated tagged packets that
1649should go through an adapter that is not offloading capable are
1650"un-accelerated" by the bonding driver so the VLAN tag sits in the
1651regular location.
1652
1653 VLAN interfaces *must* be added on top of a bonding interface
1654only after enslaving at least one slave. The bonding interface has a
1655hardware address of 00:00:00:00:00:00 until the first slave is added.
1656If the VLAN interface is created prior to the first enslavement, it
1657would pick up the all-zeroes hardware address. Once the first slave
1658is attached to the bond, the bond device itself will pick up the
1659slave's hardware address, which is then available for the VLAN device.
1660
1661 Also, be aware that a similar problem can occur if all slaves
1662are released from a bond that still has one or more VLAN interfaces on
1663top of it. When a new slave is added, the bonding interface will
1664obtain its hardware address from the first slave, which might not
1665match the hardware address of the VLAN interfaces (which was
1666ultimately copied from an earlier slave).
1667
1668 There are two methods to insure that the VLAN device operates
1669with the correct hardware address if all slaves are removed from a
1670bond interface:
1671
1672 1. Remove all VLAN interfaces then recreate them
1673
1674 2. Set the bonding interface's hardware address so that it
1675matches the hardware address of the VLAN interfaces.
1676
1677 Note that changing a VLAN interface's HW address would set the
00354cfb 1678underlying device -- i.e. the bonding interface -- to promiscuous
1da177e4
LT
1679mode, which might not be what you want.
1680
1681
6224e01d 16827. Link Monitoring
1da177e4
LT
1683==================
1684
1685 The bonding driver at present supports two schemes for
1686monitoring a slave device's link state: the ARP monitor and the MII
1687monitor.
1688
1689 At the present time, due to implementation restrictions in the
1690bonding driver itself, it is not possible to enable both ARP and MII
1691monitoring simultaneously.
1692
6224e01d 16937.1 ARP Monitor Operation
1da177e4
LT
1694-------------------------
1695
1696 The ARP monitor operates as its name suggests: it sends ARP
1697queries to one or more designated peer systems on the network, and
1698uses the response as an indication that the link is operating. This
1699gives some assurance that traffic is actually flowing to and from one
1700or more peers on the local network.
1701
1702 The ARP monitor relies on the device driver itself to verify
1703that traffic is flowing. In particular, the driver must keep up to
1704date the last receive time, dev->last_rx, and transmit start time,
1705dev->trans_start. If these are not updated by the driver, then the
1706ARP monitor will immediately fail any slaves using that driver, and
1707those slaves will stay down. If networking monitoring (tcpdump, etc)
1708shows the ARP requests and replies on the network, then it may be that
1709your device driver is not updating last_rx and trans_start.
1710
6224e01d 17117.2 Configuring Multiple ARP Targets
1da177e4
LT
1712------------------------------------
1713
1714 While ARP monitoring can be done with just one target, it can
1715be useful in a High Availability setup to have several targets to
1716monitor. In the case of just one target, the target itself may go
1717down or have a problem making it unresponsive to ARP requests. Having
1718an additional target (or several) increases the reliability of the ARP
1719monitoring.
1720
00354cfb 1721 Multiple ARP targets must be separated by commas as follows:
1da177e4
LT
1722
1723# example options for ARP monitoring with three targets
1724alias bond0 bonding
1725options bond0 arp_interval=60 arp_ip_target=192.168.0.1,192.168.0.3,192.168.0.9
1726
1727 For just a single target the options would resemble:
1728
1729# example options for ARP monitoring with one target
1730alias bond0 bonding
1731options bond0 arp_interval=60 arp_ip_target=192.168.0.100
1732
1733
6224e01d 17347.3 MII Monitor Operation
1da177e4
LT
1735-------------------------
1736
1737 The MII monitor monitors only the carrier state of the local
1738network interface. It accomplishes this in one of three ways: by
1739depending upon the device driver to maintain its carrier state, by
1740querying the device's MII registers, or by making an ethtool query to
1741the device.
1742
1743 If the use_carrier module parameter is 1 (the default value),
1744then the MII monitor will rely on the driver for carrier state
1745information (via the netif_carrier subsystem). As explained in the
1746use_carrier parameter information, above, if the MII monitor fails to
1747detect carrier loss on the device (e.g., when the cable is physically
1748disconnected), it may be that the driver does not support
1749netif_carrier.
1750
1751 If use_carrier is 0, then the MII monitor will first query the
1752device's (via ioctl) MII registers and check the link state. If that
1753request fails (not just that it returns carrier down), then the MII
1754monitor will make an ethtool ETHOOL_GLINK request to attempt to obtain
1755the same information. If both methods fail (i.e., the driver either
1756does not support or had some error in processing both the MII register
1757and ethtool requests), then the MII monitor will assume the link is
1758up.
1759
6224e01d 17608. Potential Sources of Trouble
1da177e4
LT
1761===============================
1762
6224e01d 17638.1 Adventures in Routing
1da177e4
LT
1764-------------------------
1765
1766 When bonding is configured, it is important that the slave
6224e01d 1767devices not have routes that supersede routes of the master (or,
1da177e4
LT
1768generally, not have routes at all). For example, suppose the bonding
1769device bond0 has two slaves, eth0 and eth1, and the routing table is
1770as follows:
1771
1772Kernel IP routing table
1773Destination Gateway Genmask Flags MSS Window irtt Iface
177410.0.0.0 0.0.0.0 255.255.0.0 U 40 0 0 eth0
177510.0.0.0 0.0.0.0 255.255.0.0 U 40 0 0 eth1
177610.0.0.0 0.0.0.0 255.255.0.0 U 40 0 0 bond0
1777127.0.0.0 0.0.0.0 255.0.0.0 U 40 0 0 lo
1778
1779 This routing configuration will likely still update the
1780receive/transmit times in the driver (needed by the ARP monitor), but
1781may bypass the bonding driver (because outgoing traffic to, in this
1782case, another host on network 10 would use eth0 or eth1 before bond0).
1783
1784 The ARP monitor (and ARP itself) may become confused by this
1785configuration, because ARP requests (generated by the ARP monitor)
1786will be sent on one interface (bond0), but the corresponding reply
1787will arrive on a different interface (eth0). This reply looks to ARP
1788as an unsolicited ARP reply (because ARP matches replies on an
1789interface basis), and is discarded. The MII monitor is not affected
1790by the state of the routing table.
1791
1792 The solution here is simply to insure that slaves do not have
1793routes of their own, and if for some reason they must, those routes do
6224e01d 1794not supersede routes of their master. This should generally be the
1da177e4
LT
1795case, but unusual configurations or errant manual or automatic static
1796route additions may cause trouble.
1797
6224e01d 17988.2 Ethernet Device Renaming
1da177e4
LT
1799----------------------------
1800
1801 On systems with network configuration scripts that do not
1802associate physical devices directly with network interface names (so
1803that the same physical device always has the same "ethX" name), it may
970e2486
LDM
1804be necessary to add some special logic to config files in
1805/etc/modprobe.d/.
1da177e4
LT
1806
1807 For example, given a modules.conf containing the following:
1808
1809alias bond0 bonding
1810options bond0 mode=some-mode miimon=50
1811alias eth0 tg3
1812alias eth1 tg3
1813alias eth2 e1000
1814alias eth3 e1000
1815
1816 If neither eth0 and eth1 are slaves to bond0, then when the
1817bond0 interface comes up, the devices may end up reordered. This
1818happens because bonding is loaded first, then its slave device's
1819drivers are loaded next. Since no other drivers have been loaded,
1820when the e1000 driver loads, it will receive eth0 and eth1 for its
1821devices, but the bonding configuration tries to enslave eth2 and eth3
1822(which may later be assigned to the tg3 devices).
1823
1824 Adding the following:
1825
1826add above bonding e1000 tg3
1827
1828 causes modprobe to load e1000 then tg3, in that order, when
1829bonding is loaded. This command is fully documented in the
1830modules.conf manual page.
1831
970e2486
LDM
1832 On systems utilizing modprobe an equivalent problem can occur.
1833In this case, the following can be added to config files in
1834/etc/modprobe.d/ as:
1da177e4 1835
78286cdf 1836softdep bonding pre: tg3 e1000
1da177e4 1837
970e2486
LDM
1838 This will load tg3 and e1000 modules before loading the bonding one.
1839Full documentation on this can be found in the modprobe.d and modprobe
1840manual pages.
1da177e4 1841
6224e01d 18428.3. Painfully Slow Or No Failed Link Detection By Miimon
1da177e4
LT
1843---------------------------------------------------------
1844
1845 By default, bonding enables the use_carrier option, which
1846instructs bonding to trust the driver to maintain carrier state.
1847
1848 As discussed in the options section, above, some drivers do
1849not support the netif_carrier_on/_off link state tracking system.
1850With use_carrier enabled, bonding will always see these links as up,
1851regardless of their actual state.
1852
1853 Additionally, other drivers do support netif_carrier, but do
1854not maintain it in real time, e.g., only polling the link state at
1855some fixed interval. In this case, miimon will detect failures, but
1856only after some long period of time has expired. If it appears that
1857miimon is very slow in detecting link failures, try specifying
1858use_carrier=0 to see if that improves the failure detection time. If
1859it does, then it may be that the driver checks the carrier state at a
1860fixed interval, but does not cache the MII register values (so the
1861use_carrier=0 method of querying the registers directly works). If
1862use_carrier=0 does not improve the failover, then the driver may cache
1863the registers, or the problem may be elsewhere.
1864
1865 Also, remember that miimon only checks for the device's
1866carrier state. It has no way to determine the state of devices on or
1867beyond other ports of a switch, or if a switch is refusing to pass
1868traffic while still maintaining carrier on.
1869
6224e01d 18709. SNMP agents
1da177e4
LT
1871===============
1872
1873 If running SNMP agents, the bonding driver should be loaded
1874before any network drivers participating in a bond. This requirement
d533f671 1875is due to the interface index (ipAdEntIfIndex) being associated to
1da177e4
LT
1876the first interface found with a given IP address. That is, there is
1877only one ipAdEntIfIndex for each IP address. For example, if eth0 and
1878eth1 are slaves of bond0 and the driver for eth0 is loaded before the
1879bonding driver, the interface for the IP address will be associated
1880with the eth0 interface. This configuration is shown below, the IP
1881address 192.168.1.1 has an interface index of 2 which indexes to eth0
1882in the ifDescr table (ifDescr.2).
1883
1884 interfaces.ifTable.ifEntry.ifDescr.1 = lo
1885 interfaces.ifTable.ifEntry.ifDescr.2 = eth0
1886 interfaces.ifTable.ifEntry.ifDescr.3 = eth1
1887 interfaces.ifTable.ifEntry.ifDescr.4 = eth2
1888 interfaces.ifTable.ifEntry.ifDescr.5 = eth3
1889 interfaces.ifTable.ifEntry.ifDescr.6 = bond0
1890 ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.10.10.10.10 = 5
1891 ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.192.168.1.1 = 2
1892 ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.10.74.20.94 = 4
1893 ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.127.0.0.1 = 1
1894
1895 This problem is avoided by loading the bonding driver before
1896any network drivers participating in a bond. Below is an example of
1897loading the bonding driver first, the IP address 192.168.1.1 is
1898correctly associated with ifDescr.2.
1899
1900 interfaces.ifTable.ifEntry.ifDescr.1 = lo
1901 interfaces.ifTable.ifEntry.ifDescr.2 = bond0
1902 interfaces.ifTable.ifEntry.ifDescr.3 = eth0
1903 interfaces.ifTable.ifEntry.ifDescr.4 = eth1
1904 interfaces.ifTable.ifEntry.ifDescr.5 = eth2
1905 interfaces.ifTable.ifEntry.ifDescr.6 = eth3
1906 ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.10.10.10.10 = 6
1907 ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.192.168.1.1 = 2
1908 ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.10.74.20.94 = 5
1909 ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.127.0.0.1 = 1
1910
1911 While some distributions may not report the interface name in
1912ifDescr, the association between the IP address and IfIndex remains
1913and SNMP functions such as Interface_Scan_Next will report that
1914association.
1915
6224e01d 191610. Promiscuous mode
1da177e4
LT
1917====================
1918
1919 When running network monitoring tools, e.g., tcpdump, it is
1920common to enable promiscuous mode on the device, so that all traffic
1921is seen (instead of seeing only traffic destined for the local host).
1922The bonding driver handles promiscuous mode changes to the bonding
00354cfb 1923master device (e.g., bond0), and propagates the setting to the slave
1da177e4
LT
1924devices.
1925
1926 For the balance-rr, balance-xor, broadcast, and 802.3ad modes,
00354cfb 1927the promiscuous mode setting is propagated to all slaves.
1da177e4
LT
1928
1929 For the active-backup, balance-tlb and balance-alb modes, the
00354cfb 1930promiscuous mode setting is propagated only to the active slave.
1da177e4
LT
1931
1932 For balance-tlb mode, the active slave is the slave currently
1933receiving inbound traffic.
1934
1935 For balance-alb mode, the active slave is the slave used as a
1936"primary." This slave is used for mode-specific control traffic, for
1937sending to peers that are unassigned or if the load is unbalanced.
1938
1939 For the active-backup, balance-tlb and balance-alb modes, when
1940the active slave changes (e.g., due to a link failure), the
00354cfb 1941promiscuous setting will be propagated to the new active slave.
1da177e4 1942
6224e01d 194311. Configuring Bonding for High Availability
00354cfb 1944=============================================
1da177e4
LT
1945
1946 High Availability refers to configurations that provide
1947maximum network availability by having redundant or backup devices,
00354cfb
JV
1948links or switches between the host and the rest of the world. The
1949goal is to provide the maximum availability of network connectivity
1950(i.e., the network always works), even though other configurations
1951could provide higher throughput.
1da177e4 1952
6224e01d 195311.1 High Availability in a Single Switch Topology
1da177e4
LT
1954--------------------------------------------------
1955
00354cfb
JV
1956 If two hosts (or a host and a single switch) are directly
1957connected via multiple physical links, then there is no availability
1958penalty to optimizing for maximum bandwidth. In this case, there is
1959only one switch (or peer), so if it fails, there is no alternative
1960access to fail over to. Additionally, the bonding load balance modes
1961support link monitoring of their members, so if individual links fail,
1962the load will be rebalanced across the remaining devices.
1963
f8b72d36 1964 See Section 12, "Configuring Bonding for Maximum Throughput"
00354cfb
JV
1965for information on configuring bonding with one peer device.
1966
6224e01d 196711.2 High Availability in a Multiple Switch Topology
00354cfb
JV
1968----------------------------------------------------
1969
1970 With multiple switches, the configuration of bonding and the
1971network changes dramatically. In multiple switch topologies, there is
1972a trade off between network availability and usable bandwidth.
1973
1974 Below is a sample network, configured to maximize the
1975availability of the network:
1da177e4 1976
00354cfb
JV
1977 | |
1978 |port3 port3|
1979 +-----+----+ +-----+----+
1980 | |port2 ISL port2| |
1981 | switch A +--------------------------+ switch B |
1982 | | | |
1983 +-----+----+ +-----++---+
1984 |port1 port1|
1985 | +-------+ |
1986 +-------------+ host1 +---------------+
1987 eth0 +-------+ eth1
1da177e4 1988
00354cfb
JV
1989 In this configuration, there is a link between the two
1990switches (ISL, or inter switch link), and multiple ports connecting to
1991the outside world ("port3" on each switch). There is no technical
1992reason that this could not be extended to a third switch.
1da177e4 1993
6224e01d 199411.2.1 HA Bonding Mode Selection for Multiple Switch Topology
00354cfb 1995-------------------------------------------------------------
1da177e4 1996
00354cfb
JV
1997 In a topology such as the example above, the active-backup and
1998broadcast modes are the only useful bonding modes when optimizing for
1999availability; the other modes require all links to terminate on the
2000same peer for them to behave rationally.
2001
2002active-backup: This is generally the preferred mode, particularly if
2003 the switches have an ISL and play together well. If the
2004 network configuration is such that one switch is specifically
2005 a backup switch (e.g., has lower capacity, higher cost, etc),
2006 then the primary option can be used to insure that the
2007 preferred link is always used when it is available.
2008
2009broadcast: This mode is really a special purpose mode, and is suitable
2010 only for very specific needs. For example, if the two
2011 switches are not connected (no ISL), and the networks beyond
2012 them are totally independent. In this case, if it is
2013 necessary for some specific one-way traffic to reach both
2014 independent networks, then the broadcast mode may be suitable.
2015
6224e01d 201611.2.2 HA Link Monitoring Selection for Multiple Switch Topology
00354cfb
JV
2017----------------------------------------------------------------
2018
2019 The choice of link monitoring ultimately depends upon your
2020switch. If the switch can reliably fail ports in response to other
2021failures, then either the MII or ARP monitors should work. For
2022example, in the above example, if the "port3" link fails at the remote
2023end, the MII monitor has no direct means to detect this. The ARP
2024monitor could be configured with a target at the remote end of port3,
2025thus detecting that failure without switch support.
2026
2027 In general, however, in a multiple switch topology, the ARP
2028monitor can provide a higher level of reliability in detecting end to
2029end connectivity failures (which may be caused by the failure of any
2030individual component to pass traffic for any reason). Additionally,
2031the ARP monitor should be configured with multiple targets (at least
2032one for each switch in the network). This will insure that,
2033regardless of which switch is active, the ARP monitor has a suitable
2034target to query.
2035
9a6c6867
JV
2036 Note, also, that of late many switches now support a functionality
2037generally referred to as "trunk failover." This is a feature of the
2038switch that causes the link state of a particular switch port to be set
2039down (or up) when the state of another switch port goes down (or up).
19f59460 2040Its purpose is to propagate link failures from logically "exterior" ports
9a6c6867
JV
2041to the logically "interior" ports that bonding is able to monitor via
2042miimon. Availability and configuration for trunk failover varies by
2043switch, but this can be a viable alternative to the ARP monitor when using
2044suitable switches.
00354cfb 2045
6224e01d 204612. Configuring Bonding for Maximum Throughput
00354cfb
JV
2047==============================================
2048
6224e01d 204912.1 Maximizing Throughput in a Single Switch Topology
00354cfb
JV
2050------------------------------------------------------
2051
2052 In a single switch configuration, the best method to maximize
2053throughput depends upon the application and network environment. The
2054various load balancing modes each have strengths and weaknesses in
2055different environments, as detailed below.
2056
2057 For this discussion, we will break down the topologies into
2058two categories. Depending upon the destination of most traffic, we
2059categorize them into either "gatewayed" or "local" configurations.
2060
2061 In a gatewayed configuration, the "switch" is acting primarily
2062as a router, and the majority of traffic passes through this router to
2063other networks. An example would be the following:
2064
2065
2066 +----------+ +----------+
2067 | |eth0 port1| | to other networks
2068 | Host A +---------------------+ router +------------------->
2069 | +---------------------+ | Hosts B and C are out
2070 | |eth1 port2| | here somewhere
2071 +----------+ +----------+
2072
2073 The router may be a dedicated router device, or another host
2074acting as a gateway. For our discussion, the important point is that
2075the majority of traffic from Host A will pass through the router to
2076some other network before reaching its final destination.
2077
2078 In a gatewayed network configuration, although Host A may
2079communicate with many other systems, all of its traffic will be sent
2080and received via one other peer on the local network, the router.
2081
2082 Note that the case of two systems connected directly via
2083multiple physical links is, for purposes of configuring bonding, the
2084same as a gatewayed configuration. In that case, it happens that all
2085traffic is destined for the "gateway" itself, not some other network
2086beyond the gateway.
2087
2088 In a local configuration, the "switch" is acting primarily as
2089a switch, and the majority of traffic passes through this switch to
2090reach other stations on the same network. An example would be the
2091following:
2092
2093 +----------+ +----------+ +--------+
2094 | |eth0 port1| +-------+ Host B |
2095 | Host A +------------+ switch |port3 +--------+
2096 | +------------+ | +--------+
2097 | |eth1 port2| +------------------+ Host C |
2098 +----------+ +----------+port4 +--------+
2099
2100
2101 Again, the switch may be a dedicated switch device, or another
2102host acting as a gateway. For our discussion, the important point is
2103that the majority of traffic from Host A is destined for other hosts
2104on the same local network (Hosts B and C in the above example).
2105
2106 In summary, in a gatewayed configuration, traffic to and from
2107the bonded device will be to the same MAC level peer on the network
2108(the gateway itself, i.e., the router), regardless of its final
2109destination. In a local configuration, traffic flows directly to and
2110from the final destinations, thus, each destination (Host B, Host C)
2111will be addressed directly by their individual MAC addresses.
2112
2113 This distinction between a gatewayed and a local network
2114configuration is important because many of the load balancing modes
2115available use the MAC addresses of the local network source and
2116destination to make load balancing decisions. The behavior of each
2117mode is described below.
2118
2119
6224e01d 212012.1.1 MT Bonding Mode Selection for Single Switch Topology
00354cfb 2121-----------------------------------------------------------
1da177e4
LT
2122
2123 This configuration is the easiest to set up and to understand,
2124although you will have to decide which bonding mode best suits your
00354cfb 2125needs. The trade offs for each mode are detailed below:
1da177e4
LT
2126
2127balance-rr: This mode is the only mode that will permit a single
2128 TCP/IP connection to stripe traffic across multiple
2129 interfaces. It is therefore the only mode that will allow a
2130 single TCP/IP stream to utilize more than one interface's
2131 worth of throughput. This comes at a cost, however: the
9a6c6867 2132 striping generally results in peer systems receiving packets out
1da177e4
LT
2133 of order, causing TCP/IP's congestion control system to kick
2134 in, often by retransmitting segments.
2135
2136 It is possible to adjust TCP/IP's congestion limits by
2137 altering the net.ipv4.tcp_reordering sysctl parameter. The
2138 usual default value is 3, and the maximum useful value is 127.
2139 For a four interface balance-rr bond, expect that a single
2140 TCP/IP stream will utilize no more than approximately 2.3
2141 interface's worth of throughput, even after adjusting
2142 tcp_reordering.
2143
9a6c6867
JV
2144 Note that the fraction of packets that will be delivered out of
2145 order is highly variable, and is unlikely to be zero. The level
2146 of reordering depends upon a variety of factors, including the
2147 networking interfaces, the switch, and the topology of the
2148 configuration. Speaking in general terms, higher speed network
2149 cards produce more reordering (due to factors such as packet
2150 coalescing), and a "many to many" topology will reorder at a
2151 higher rate than a "many slow to one fast" configuration.
2152
2153 Many switches do not support any modes that stripe traffic
2154 (instead choosing a port based upon IP or MAC level addresses);
2155 for those devices, traffic for a particular connection flowing
2156 through the switch to a balance-rr bond will not utilize greater
2157 than one interface's worth of bandwidth.
00354cfb 2158
1da177e4
LT
2159 If you are utilizing protocols other than TCP/IP, UDP for
2160 example, and your application can tolerate out of order
2161 delivery, then this mode can allow for single stream datagram
2162 performance that scales near linearly as interfaces are added
2163 to the bond.
2164
2165 This mode requires the switch to have the appropriate ports
2166 configured for "etherchannel" or "trunking."
2167
2168active-backup: There is not much advantage in this network topology to
2169 the active-backup mode, as the inactive backup devices are all
2170 connected to the same peer as the primary. In this case, a
2171 load balancing mode (with link monitoring) will provide the
2172 same level of network availability, but with increased
00354cfb
JV
2173 available bandwidth. On the plus side, active-backup mode
2174 does not require any configuration of the switch, so it may
2175 have value if the hardware available does not support any of
2176 the load balance modes.
1da177e4
LT
2177
2178balance-xor: This mode will limit traffic such that packets destined
2179 for specific peers will always be sent over the same
2180 interface. Since the destination is determined by the MAC
00354cfb
JV
2181 addresses involved, this mode works best in a "local" network
2182 configuration (as described above), with destinations all on
2183 the same local network. This mode is likely to be suboptimal
2184 if all your traffic is passed through a single router (i.e., a
2185 "gatewayed" network configuration, as described above).
2186
2187 As with balance-rr, the switch ports need to be configured for
1da177e4
LT
2188 "etherchannel" or "trunking."
2189
2190broadcast: Like active-backup, there is not much advantage to this
2191 mode in this type of network topology.
2192
2193802.3ad: This mode can be a good choice for this type of network
2194 topology. The 802.3ad mode is an IEEE standard, so all peers
2195 that implement 802.3ad should interoperate well. The 802.3ad
2196 protocol includes automatic configuration of the aggregates,
2197 so minimal manual configuration of the switch is needed
2198 (typically only to designate that some set of devices is
00354cfb
JV
2199 available for 802.3ad). The 802.3ad standard also mandates
2200 that frames be delivered in order (within certain limits), so
2201 in general single connections will not see misordering of
1da177e4
LT
2202 packets. The 802.3ad mode does have some drawbacks: the
2203 standard mandates that all devices in the aggregate operate at
2204 the same speed and duplex. Also, as with all bonding load
2205 balance modes other than balance-rr, no single connection will
2206 be able to utilize more than a single interface's worth of
00354cfb
JV
2207 bandwidth.
2208
2209 Additionally, the linux bonding 802.3ad implementation
2210 distributes traffic by peer (using an XOR of MAC addresses),
2211 so in a "gatewayed" configuration, all outgoing traffic will
2212 generally use the same device. Incoming traffic may also end
2213 up on a single device, but that is dependent upon the
2214 balancing policy of the peer's 8023.ad implementation. In a
2215 "local" configuration, traffic will be distributed across the
2216 devices in the bond.
2217
2218 Finally, the 802.3ad mode mandates the use of the MII monitor,
2219 therefore, the ARP monitor is not available in this mode.
2220
2221balance-tlb: The balance-tlb mode balances outgoing traffic by peer.
2222 Since the balancing is done according to MAC address, in a
2223 "gatewayed" configuration (as described above), this mode will
2224 send all traffic across a single device. However, in a
2225 "local" network configuration, this mode balances multiple
2226 local network peers across devices in a vaguely intelligent
2227 manner (not a simple XOR as in balance-xor or 802.3ad mode),
2228 so that mathematically unlucky MAC addresses (i.e., ones that
2229 XOR to the same value) will not all "bunch up" on a single
2230 interface.
2231
2232 Unlike 802.3ad, interfaces may be of differing speeds, and no
2233 special switch configuration is required. On the down side,
2234 in this mode all incoming traffic arrives over a single
2235 interface, this mode requires certain ethtool support in the
2236 network device driver of the slave interfaces, and the ARP
2237 monitor is not available.
2238
2239balance-alb: This mode is everything that balance-tlb is, and more.
2240 It has all of the features (and restrictions) of balance-tlb,
2241 and will also balance incoming traffic from local network
2242 peers (as described in the Bonding Module Options section,
2243 above).
2244
2245 The only additional down side to this mode is that the network
2246 device driver must support changing the hardware address while
2247 the device is open.
2248
6224e01d 224912.1.2 MT Link Monitoring for Single Switch Topology
00354cfb 2250----------------------------------------------------
1da177e4
LT
2251
2252 The choice of link monitoring may largely depend upon which
2253mode you choose to use. The more advanced load balancing modes do not
2254support the use of the ARP monitor, and are thus restricted to using
00354cfb
JV
2255the MII monitor (which does not provide as high a level of end to end
2256assurance as the ARP monitor).
2257
6224e01d 225812.2 Maximum Throughput in a Multiple Switch Topology
00354cfb
JV
2259-----------------------------------------------------
2260
2261 Multiple switches may be utilized to optimize for throughput
2262when they are configured in parallel as part of an isolated network
2263between two or more systems, for example:
2264
2265 +-----------+
2266 | Host A |
2267 +-+---+---+-+
2268 | | |
2269 +--------+ | +---------+
2270 | | |
2271 +------+---+ +-----+----+ +-----+----+
2272 | Switch A | | Switch B | | Switch C |
2273 +------+---+ +-----+----+ +-----+----+
2274 | | |
2275 +--------+ | +---------+
2276 | | |
2277 +-+---+---+-+
2278 | Host B |
2279 +-----------+
2280
2281 In this configuration, the switches are isolated from one
2282another. One reason to employ a topology such as this is for an
2283isolated network with many hosts (a cluster configured for high
2284performance, for example), using multiple smaller switches can be more
2285cost effective than a single larger switch, e.g., on a network with 24
2286hosts, three 24 port switches can be significantly less expensive than
2287a single 72 port switch.
2288
2289 If access beyond the network is required, an individual host
2290can be equipped with an additional network device connected to an
2291external network; this host then additionally acts as a gateway.
2292
6224e01d 229312.2.1 MT Bonding Mode Selection for Multiple Switch Topology
1da177e4
LT
2294-------------------------------------------------------------
2295
00354cfb
JV
2296 In actual practice, the bonding mode typically employed in
2297configurations of this type is balance-rr. Historically, in this
2298network configuration, the usual caveats about out of order packet
2299delivery are mitigated by the use of network adapters that do not do
2300any kind of packet coalescing (via the use of NAPI, or because the
2301device itself does not generate interrupts until some number of
2302packets has arrived). When employed in this fashion, the balance-rr
2303mode allows individual connections between two hosts to effectively
2304utilize greater than one interface's bandwidth.
1da177e4 2305
6224e01d 230612.2.2 MT Link Monitoring for Multiple Switch Topology
00354cfb 2307------------------------------------------------------
1da177e4 2308
00354cfb
JV
2309 Again, in actual practice, the MII monitor is most often used
2310in this configuration, as performance is given preference over
2311availability. The ARP monitor will function in this topology, but its
2312advantages over the MII monitor are mitigated by the volume of probes
2313needed as the number of systems involved grows (remember that each
2314host in the network is configured with bonding).
1da177e4 2315
6224e01d 231613. Switch Behavior Issues
00354cfb 2317==========================
1da177e4 2318
6224e01d 231913.1 Link Establishment and Failover Delays
00354cfb
JV
2320-------------------------------------------
2321
2322 Some switches exhibit undesirable behavior with regard to the
2323timing of link up and down reporting by the switch.
1da177e4
LT
2324
2325 First, when a link comes up, some switches may indicate that
2326the link is up (carrier available), but not pass traffic over the
2327interface for some period of time. This delay is typically due to
2328some type of autonegotiation or routing protocol, but may also occur
2329during switch initialization (e.g., during recovery after a switch
2330failure). If you find this to be a problem, specify an appropriate
2331value to the updelay bonding module option to delay the use of the
2332relevant interface(s).
2333
2334 Second, some switches may "bounce" the link state one or more
2335times while a link is changing state. This occurs most commonly while
2336the switch is initializing. Again, an appropriate updelay value may
00354cfb 2337help.
1da177e4
LT
2338
2339 Note that when a bonding interface has no active links, the
00354cfb
JV
2340driver will immediately reuse the first link that goes up, even if the
2341updelay parameter has been specified (the updelay is ignored in this
2342case). If there are slave interfaces waiting for the updelay timeout
2343to expire, the interface that first went into that state will be
2344immediately reused. This reduces down time of the network if the
2345value of updelay has been overestimated, and since this occurs only in
2346cases with no connectivity, there is no additional penalty for
2347ignoring the updelay.
1da177e4
LT
2348
2349 In addition to the concerns about switch timings, if your
2350switches take a long time to go into backup mode, it may be desirable
2351to not activate a backup interface immediately after a link goes down.
2352Failover may be delayed via the downdelay bonding module option.
2353
6224e01d 235413.2 Duplicated Incoming Packets
00354cfb
JV
2355--------------------------------
2356
9a6c6867
JV
2357 NOTE: Starting with version 3.0.2, the bonding driver has logic to
2358suppress duplicate packets, which should largely eliminate this problem.
2359The following description is kept for reference.
2360
00354cfb
JV
2361 It is not uncommon to observe a short burst of duplicated
2362traffic when the bonding device is first used, or after it has been
2363idle for some period of time. This is most easily observed by issuing
2364a "ping" to some other host on the network, and noticing that the
2365output from ping flags duplicates (typically one per slave).
2366
2367 For example, on a bond in active-backup mode with five slaves
2368all connected to one switch, the output may appear as follows:
2369
2370# ping -n 10.0.4.2
2371PING 10.0.4.2 (10.0.4.2) from 10.0.3.10 : 56(84) bytes of data.
237264 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.7 ms
237364 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.8 ms (DUP!)
237464 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.8 ms (DUP!)
237564 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.8 ms (DUP!)
237664 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.8 ms (DUP!)
237764 bytes from 10.0.4.2: icmp_seq=2 ttl=64 time=0.216 ms
237864 bytes from 10.0.4.2: icmp_seq=3 ttl=64 time=0.267 ms
237964 bytes from 10.0.4.2: icmp_seq=4 ttl=64 time=0.222 ms
2380
2381 This is not due to an error in the bonding driver, rather, it
2382is a side effect of how many switches update their MAC forwarding
2383tables. Initially, the switch does not associate the MAC address in
2384the packet with a particular switch port, and so it may send the
2385traffic to all ports until its MAC forwarding table is updated. Since
2386the interfaces attached to the bond may occupy multiple ports on a
2387single switch, when the switch (temporarily) floods the traffic to all
2388ports, the bond device receives multiple copies of the same packet
2389(one per slave device).
2390
2391 The duplicated packet behavior is switch dependent, some
2392switches exhibit this, and some do not. On switches that display this
2393behavior, it can be induced by clearing the MAC forwarding table (on
2394most Cisco switches, the privileged command "clear mac address-table
2395dynamic" will accomplish this).
2396
6224e01d 239714. Hardware Specific Considerations
1da177e4
LT
2398====================================
2399
2400 This section contains additional information for configuring
2401bonding on specific hardware platforms, or for interfacing bonding
2402with particular switches or other devices.
2403
6224e01d 240414.1 IBM BladeCenter
1da177e4
LT
2405--------------------
2406
2407 This applies to the JS20 and similar systems.
2408
2409 On the JS20 blades, the bonding driver supports only
2410balance-rr, active-backup, balance-tlb and balance-alb modes. This is
2411largely due to the network topology inside the BladeCenter, detailed
2412below.
2413
2414JS20 network adapter information
2415--------------------------------
2416
2417 All JS20s come with two Broadcom Gigabit Ethernet ports
00354cfb
JV
2418integrated on the planar (that's "motherboard" in IBM-speak). In the
2419BladeCenter chassis, the eth0 port of all JS20 blades is hard wired to
2420I/O Module #1; similarly, all eth1 ports are wired to I/O Module #2.
2421An add-on Broadcom daughter card can be installed on a JS20 to provide
2422two more Gigabit Ethernet ports. These ports, eth2 and eth3, are
2423wired to I/O Modules 3 and 4, respectively.
1da177e4
LT
2424
2425 Each I/O Module may contain either a switch or a passthrough
2426module (which allows ports to be directly connected to an external
2427switch). Some bonding modes require a specific BladeCenter internal
2428network topology in order to function; these are detailed below.
2429
2430 Additional BladeCenter-specific networking information can be
2431found in two IBM Redbooks (www.ibm.com/redbooks):
2432
2433"IBM eServer BladeCenter Networking Options"
2434"IBM eServer BladeCenter Layer 2-7 Network Switching"
2435
2436BladeCenter networking configuration
2437------------------------------------
2438
2439 Because a BladeCenter can be configured in a very large number
2440of ways, this discussion will be confined to describing basic
2441configurations.
2442
00354cfb 2443 Normally, Ethernet Switch Modules (ESMs) are used in I/O
1da177e4
LT
2444modules 1 and 2. In this configuration, the eth0 and eth1 ports of a
2445JS20 will be connected to different internal switches (in the
2446respective I/O modules).
2447
00354cfb
JV
2448 A passthrough module (OPM or CPM, optical or copper,
2449passthrough module) connects the I/O module directly to an external
2450switch. By using PMs in I/O module #1 and #2, the eth0 and eth1
2451interfaces of a JS20 can be redirected to the outside world and
2452connected to a common external switch.
2453
2454 Depending upon the mix of ESMs and PMs, the network will
2455appear to bonding as either a single switch topology (all PMs) or as a
2456multiple switch topology (one or more ESMs, zero or more PMs). It is
2457also possible to connect ESMs together, resulting in a configuration
2458much like the example in "High Availability in a Multiple Switch
2459Topology," above.
2460
2461Requirements for specific modes
2462-------------------------------
2463
2464 The balance-rr mode requires the use of passthrough modules
2465for devices in the bond, all connected to an common external switch.
2466That switch must be configured for "etherchannel" or "trunking" on the
1da177e4
LT
2467appropriate ports, as is usual for balance-rr.
2468
2469 The balance-alb and balance-tlb modes will function with
2470either switch modules or passthrough modules (or a mix). The only
2471specific requirement for these modes is that all network interfaces
2472must be able to reach all destinations for traffic sent over the
2473bonding device (i.e., the network must converge at some point outside
2474the BladeCenter).
2475
2476 The active-backup mode has no additional requirements.
2477
2478Link monitoring issues
2479----------------------
2480
2481 When an Ethernet Switch Module is in place, only the ARP
2482monitor will reliably detect link loss to an external switch. This is
2483nothing unusual, but examination of the BladeCenter cabinet would
2484suggest that the "external" network ports are the ethernet ports for
2485the system, when it fact there is a switch between these "external"
2486ports and the devices on the JS20 system itself. The MII monitor is
2487only able to detect link failures between the ESM and the JS20 system.
2488
2489 When a passthrough module is in place, the MII monitor does
2490detect failures to the "external" port, which is then directly
2491connected to the JS20 system.
2492
2493Other concerns
2494--------------
2495
00354cfb 2496 The Serial Over LAN (SoL) link is established over the primary
1da177e4
LT
2497ethernet (eth0) only, therefore, any loss of link to eth0 will result
2498in losing your SoL connection. It will not fail over with other
00354cfb
JV
2499network traffic, as the SoL system is beyond the control of the
2500bonding driver.
1da177e4
LT
2501
2502 It may be desirable to disable spanning tree on the switch
2503(either the internal Ethernet Switch Module, or an external switch) to
00354cfb 2504avoid fail-over delay issues when using bonding.
1da177e4
LT
2505
2506
6224e01d 250715. Frequently Asked Questions
1da177e4
LT
2508==============================
2509
25101. Is it SMP safe?
2511
2512 Yes. The old 2.0.xx channel bonding patch was not SMP safe.
2513The new driver was designed to be SMP safe from the start.
2514
25152. What type of cards will work with it?
2516
2517 Any Ethernet type cards (you can even mix cards - a Intel
00354cfb
JV
2518EtherExpress PRO/100 and a 3com 3c905b, for example). For most modes,
2519devices need not be of the same speed.
1da177e4 2520
9a6c6867
JV
2521 Starting with version 3.2.1, bonding also supports Infiniband
2522slaves in active-backup mode.
2523
1da177e4
LT
25243. How many bonding devices can I have?
2525
2526 There is no limit.
2527
25284. How many slaves can a bonding device have?
2529
2530 This is limited only by the number of network interfaces Linux
2531supports and/or the number of network cards you can place in your
2532system.
2533
25345. What happens when a slave link dies?
2535
2536 If link monitoring is enabled, then the failing device will be
2537disabled. The active-backup mode will fail over to a backup link, and
2538other modes will ignore the failed link. The link will continue to be
2539monitored, and should it recover, it will rejoin the bond (in whatever
00354cfb
JV
2540manner is appropriate for the mode). See the sections on High
2541Availability and the documentation for each mode for additional
2542information.
1da177e4
LT
2543
2544 Link monitoring can be enabled via either the miimon or
00354cfb 2545arp_interval parameters (described in the module parameters section,
1da177e4
LT
2546above). In general, miimon monitors the carrier state as sensed by
2547the underlying network device, and the arp monitor (arp_interval)
2548monitors connectivity to another host on the local network.
2549
2550 If no link monitoring is configured, the bonding driver will
2551be unable to detect link failures, and will assume that all links are
2552always available. This will likely result in lost packets, and a
00354cfb 2553resulting degradation of performance. The precise performance loss
1da177e4
LT
2554depends upon the bonding mode and network configuration.
2555
25566. Can bonding be used for High Availability?
2557
2558 Yes. See the section on High Availability for details.
2559
25607. Which switches/systems does it work with?
2561
2562 The full answer to this depends upon the desired mode.
2563
2564 In the basic balance modes (balance-rr and balance-xor), it
2565works with any system that supports etherchannel (also called
2566trunking). Most managed switches currently available have such
00354cfb 2567support, and many unmanaged switches as well.
1da177e4
LT
2568
2569 The advanced balance modes (balance-tlb and balance-alb) do
2570not have special switch requirements, but do need device drivers that
2571support specific features (described in the appropriate section under
00354cfb 2572module parameters, above).
1da177e4 2573
6224e01d 2574 In 802.3ad mode, it works with systems that support IEEE
1da177e4
LT
2575802.3ad Dynamic Link Aggregation. Most managed and many unmanaged
2576switches currently available support 802.3ad.
2577
2578 The active-backup mode should work with any Layer-II switch.
2579
25808. Where does a bonding device get its MAC address from?
2581
9a6c6867
JV
2582 When using slave devices that have fixed MAC addresses, or when
2583the fail_over_mac option is enabled, the bonding device's MAC address is
2584the MAC address of the active slave.
2585
2586 For other configurations, if not explicitly configured (with
2587ifconfig or ip link), the MAC address of the bonding device is taken from
2588its first slave device. This MAC address is then passed to all following
2589slaves and remains persistent (even if the first slave is removed) until
2590the bonding device is brought down or reconfigured.
1da177e4
LT
2591
2592 If you wish to change the MAC address, you can set it with
00354cfb 2593ifconfig or ip link:
1da177e4
LT
2594
2595# ifconfig bond0 hw ether 00:11:22:33:44:55
2596
00354cfb
JV
2597# ip link set bond0 address 66:77:88:99:aa:bb
2598
1da177e4
LT
2599 The MAC address can be also changed by bringing down/up the
2600device and then changing its slaves (or their order):
2601
2602# ifconfig bond0 down ; modprobe -r bonding
2603# ifconfig bond0 .... up
2604# ifenslave bond0 eth...
2605
2606 This method will automatically take the address from the next
2607slave that is added.
2608
2609 To restore your slaves' MAC addresses, you need to detach them
2610from the bond (`ifenslave -d bond0 eth0'). The bonding driver will
2611then restore the MAC addresses that the slaves had before they were
2612enslaved.
2613
00354cfb 261416. Resources and Links
1da177e4
LT
2615=======================
2616
a23c37f1 2617 The latest version of the bonding driver can be found in the latest
1da177e4
LT
2618version of the linux kernel, found on http://kernel.org
2619
a23c37f1
NP
2620 The latest version of this document can be found in the latest kernel
2621source (named Documentation/networking/bonding.txt).
00354cfb 2622
a23c37f1
NP
2623 Discussions regarding the usage of the bonding driver take place on the
2624bonding-devel mailing list, hosted at sourceforge.net. If you have questions or
2625problems, post them to the list. The list address is:
1da177e4
LT
2626
2627bonding-devel@lists.sourceforge.net
2628
00354cfb
JV
2629 The administrative interface (to subscribe or unsubscribe) can
2630be found at:
1da177e4 2631
00354cfb 2632https://lists.sourceforge.net/lists/listinfo/bonding-devel
1da177e4 2633
f8b72d36 2634 Discussions regarding the development of the bonding driver take place
a23c37f1
NP
2635on the main Linux network mailing list, hosted at vger.kernel.org. The list
2636address is:
2637
2638netdev@vger.kernel.org
2639
2640 The administrative interface (to subscribe or unsubscribe) can
2641be found at:
2642
2643http://vger.kernel.org/vger-lists.html#netdev
2644
1da177e4 2645Donald Becker's Ethernet Drivers and diag programs may be found at :
0ea6e611 2646 - http://web.archive.org/web/*/http://www.scyld.com/network/
1da177e4
LT
2647
2648You will also find a lot of information regarding Ethernet, NWay, MII,
2649etc. at www.scyld.com.
2650
2651-- END --