]>
Commit | Line | Data |
---|---|---|
0aefabc5 TL |
1 | proxmox-installer (8.1.10) bookworm; urgency=medium |
2 | ||
3 | * run command: wait for process exit with sub-second granularity to avoid | |
4 | artificially delay. | |
5 | ||
6 | -- Proxmox Support Team <support@proxmox.com> Mon, 26 Feb 2024 20:51:03 +0100 | |
7 | ||
b3ca654d TL |
8 | proxmox-installer (8.1.9) bookworm; urgency=medium |
9 | ||
10 | * run command: avoid using the true value 1 as a special value for parser | |
11 | closure to avoid false-positive detection of CMD_FINISHED flag | |
12 | ||
13 | -- Proxmox Support Team <support@proxmox.com> Mon, 26 Feb 2024 15:11:45 +0100 | |
14 | ||
719d617f TL |
15 | proxmox-installer (8.1.8) bookworm; urgency=medium |
16 | ||
17 | * ZFS : remove deprecated "fletcher2" algorithm and the dangerous "off" | |
18 | checksum options | |
19 | ||
20 | * GTK based UI: replace the use of nested boxes for layouting with grids | |
21 | when possible to ensure correct margins and alignment of widgets. | |
22 | ||
23 | * fix #4872: run env: set timeout for country detection | |
24 | ||
25 | * common: fqdn: do not allow overlong FQDNs, limit to 63 characters per part | |
26 | and 253 charactrers total, as per Debian spec | |
27 | ||
28 | * common: fqdn: implement case-insensitive comparison as per RFC 952 | |
29 | ||
30 | * fix #5230: properly escape FQDN regex to avoid that problematic values can | |
31 | make it into the host configuration files by mistake | |
32 | ||
33 | * switch over to JSON-based protocol for installer to UI communication | |
34 | ||
35 | ||
36 | -- Proxmox Support Team <support@proxmox.com> Sat, 24 Feb 2024 16:30:08 +0100 | |
37 | ||
52c995e2 TL |
38 | proxmox-installer (8.1.7) bookworm; urgency=medium |
39 | ||
40 | * source interfaces.d snippets by default | |
41 | ||
42 | -- Proxmox Support Team <support@proxmox.com> Thu, 23 Nov 2023 11:11:20 +0100 | |
43 | ||
819ded5e TL |
44 | proxmox-installer (8.1.6) bookworm; urgency=medium |
45 | ||
46 | * grub: install all efi binaries in fallback/default dir | |
47 | ||
48 | -- Proxmox Support Team <support@proxmox.com> Wed, 22 Nov 2023 13:30:06 +0100 | |
49 | ||
fd45abf8 TL |
50 | proxmox-installer (8.1.5) bookworm; urgency=medium |
51 | ||
52 | * various fixes for the TUI installer: | |
53 | - do not center EULA text | |
54 | - preserve auto-reboot checkbox state when switching views | |
55 | - common: enforce even number of disks for ZFS RAID-10 | |
56 | ||
57 | * serial installer: add serial config for grub to target system | |
58 | ||
59 | * zfs: create dataset var-lib-vz for /var/lib/vz to avoid to many | |
60 | intermediate datasets | |
61 | ||
62 | * ZFS: detect and handle secure boot | |
63 | ||
64 | -- Proxmox Support Team <support@proxmox.com> Tue, 21 Nov 2023 14:22:23 +0100 | |
65 | ||
949f192e TL |
66 | proxmox-installer (8.1.4) bookworm; urgency=medium |
67 | ||
68 | * tui: fix changing between non-LVM and LVM filesystem in bootdisk chooser | |
69 | ||
70 | * ui: stdio: replace newlines with whitespaces in prompt messages | |
71 | ||
72 | * tui: install progress: use ok/cancel as button text for installer prompt | |
73 | ||
74 | * tui: bootdisk zfs config: add a maximum value to the `copies` option | |
75 | ||
76 | * tui: fix interface sort order | |
77 | ||
78 | -- Proxmox Support Team <support@proxmox.com> Fri, 17 Nov 2023 19:35:19 +0100 | |
79 | ||
1f7d8d09 TL |
80 | proxmox-installer (8.1.3) bookworm; urgency=medium |
81 | ||
82 | * run env: do not store empty hostname when trying to detect from DHCP | |
83 | ||
84 | * gtk installer: show the unit of inputs for the disk related options | |
85 | ||
86 | -- Proxmox Support Team <support@proxmox.com> Fri, 17 Nov 2023 07:39:23 +0100 | |
87 | ||
a8379706 TL |
88 | proxmox-installer (8.1.2) bookworm; urgency=medium |
89 | ||
90 | * x display server: disable screen saver via blank time | |
91 | ||
92 | * zfs: create /var/lib/vz only for PVE | |
93 | ||
94 | -- Proxmox Support Team <support@proxmox.com> Thu, 16 Nov 2023 19:21:09 +0100 | |
95 | ||
f7acac05 TL |
96 | proxmox-installer (8.1.1) bookworm; urgency=medium |
97 | ||
98 | * pass optional console parameter from installer to target | |
99 | ||
100 | * serial install: fix console parameter parsing | |
101 | ||
102 | * fix #4747: pass kernel cmdline parameters to target system | |
103 | ||
104 | * fix #1410: zfs: create /var/lib/vz as separate dataset | |
105 | ||
106 | * zfs: set acltype=posix for root-dataset to ensure that daemons like | |
107 | journald can provide fine-grained access to non-root users. | |
108 | ||
109 | -- Proxmox Support Team <support@proxmox.com> Thu, 16 Nov 2023 08:33:32 +0100 | |
110 | ||
36a14a61 TL |
111 | proxmox-installer (8.1.0) bookworm; urgency=medium |
112 | ||
113 | * various improvements for the TUI installer: | |
114 | - fix #4856: bootdisk: use correct defaults in advanced dialog. | |
115 | - fix incorrect scrolling of form view contents. | |
116 | - don't abort install if minimum memory requirement is not met, allow | |
117 | the user to override this just like in the GTK based installer. | |
118 | - add "Deselect All" button to ZFS and Btrfs multiple disk selection. | |
119 | - improve FQDN validation. | |
120 | - improve bootdisk dialog error handling. | |
121 | - add RAID setup checks for ZFS/Btrfs. | |
122 | - password: include minimum password length in error message. | |
123 | - network: select matching NIC for IP configuration. | |
124 | - setup: fix disk size for 4Kn block devices. | |
125 | - setup: handle missing disk block size gracefully. | |
126 | - update count down of auto-reboot timeout every second like the GTK based | |
127 | installer does. | |
128 | - fix various typos. | |
129 | ||
130 | * disk partitioning: fix checking the answer for the to-small-disk prompt. | |
131 | ||
132 | * raid setup: btrfs: do not allow legacy BIOS boot on 4Kn disks, like it's | |
133 | already checked for LVM and ZFS. | |
134 | ||
135 | * fix #4869: Add marker to the network interfaces that are in an UP-state in | |
136 | the management interface selection. | |
137 | ||
138 | * re-use hostname from the runtime environment, if available. For now, this | |
139 | info comes from the DHCP lease only. | |
140 | ||
141 | * fix #4829: install: add new ZFS `arc_max` setup option and set the default | |
142 | for Proxmox VE installations via a new heuristic, targetting 10 % of | |
143 | memory, not 50 % and clamp this to minimum 64 MiB and maxmimum 16 GiB. | |
144 | This ensures that most memory is available for virtual guests, the primary | |
145 | use case of Proxmox VE. | |
146 | ||
147 | * install correct grub metapackage for the current boot-mode. | |
148 | ||
149 | -- Proxmox Support Team <support@proxmox.com> Sat, 11 Nov 2023 14:31:49 +0100 | |
150 | ||
8186bc7b TL |
151 | proxmox-installer (8.0.14) bookworm; urgency=medium |
152 | ||
153 | * pmg: disable clamav-clamonacc.service by default on installation | |
154 | ||
155 | -- Proxmox Support Team <support@proxmox.com> Wed, 28 Jun 2023 18:39:41 +0200 | |
156 | ||
aac8082f | 157 | proxmox-installer (8.0.13) bookworm; urgency=medium |
87c98625 TL |
158 | |
159 | * tui: only show warning for missing hyper-visor CPU flags for PVE | |
160 | ||
161 | * tui: block & notify if same disk gets selected twice for Btrfs or ZFS | |
162 | ||
aac8082f TL |
163 | * tui: persist disk selection for ZFS and Btrfs |
164 | ||
165 | -- Proxmox Support Team <support@proxmox.com> Tue, 27 Jun 2023 16:19:33 +0200 | |
87c98625 | 166 | |
ce8fdebb TL |
167 | proxmox-installer (8.0.11) bookworm; urgency=medium |
168 | ||
169 | * tui: hide max-vz and max-root inputs if product isn't PVE to be consistent | |
170 | with the GTK based installer. | |
171 | ||
172 | -- Proxmox Support Team <support@proxmox.com> Mon, 26 Jun 2023 21:39:45 +0200 | |
173 | ||
eab366db TL |
174 | proxmox-installer (8.0.10) bookworm; urgency=medium |
175 | ||
176 | * tui: use product for default hostname | |
177 | ||
178 | * tui: boot disks: filter out Btrfs if setup-info disallows it, like for | |
179 | Proxmox Mail Gateway or Proxmox Backup Server currently. | |
180 | ||
181 | -- Proxmox Support Team <support@proxmox.com> Mon, 26 Jun 2023 19:09:07 +0200 | |
182 | ||
f8a5d041 TL |
183 | proxmox-installer (8.0.9) bookworm; urgency=medium |
184 | ||
185 | * tui: switch to `f64` for disk sizes for full range of values | |
186 | ||
187 | * tui: wrap multi-disk selection in scrollable view | |
188 | ||
189 | * tui: disable automatic text wrapping for form labels | |
190 | ||
191 | * tui: add some info to unknown UI messages | |
192 | ||
193 | * tui: do not auto reboot on failures | |
194 | ||
195 | * gtk: raid disk selector: separate UI state from config state to avoid | |
196 | messing with the order of selection | |
197 | ||
198 | * align metadata size and rootdisk size to 4 MiB | |
199 | ||
200 | * fix space calculation for small disks for pve product | |
201 | ||
202 | -- Proxmox Support Team <support@proxmox.com> Thu, 22 Jun 2023 16:48:18 +0200 | |
203 | ||
f6159385 TL |
204 | proxmox-installer (8.0.8) bookworm; urgency=medium |
205 | ||
206 | * Revert "critic: lazily read directories via <> glob" | |
207 | ||
208 | -- Proxmox Support Team <support@proxmox.com> Thu, 22 Jun 2023 10:48:12 +0200 | |
209 | ||
4d942895 TL |
210 | proxmox-installer (8.0.7) bookworm; urgency=medium |
211 | ||
212 | * fix checking the response of the prompt, which is now returning a boolean. | |
213 | This fixes an issue where the user was prompted for small root disk space | |
214 | or if renaming the PVE VG is ok, but the installer always aborted. | |
215 | ||
216 | -- Proxmox Support Team <support@proxmox.com> Thu, 22 Jun 2023 07:38:24 +0200 | |
217 | ||
cb879145 TL |
218 | proxmox-installer (8.0.6) bookworm; urgency=medium |
219 | ||
220 | * tui: remove underline-effect from advanced disk setup titles | |
221 | ||
222 | * tui: clamp max LVM disk size to size of selected disk | |
223 | ||
224 | * tui: fix ability to type commas | |
225 | ||
226 | * tui: do not fail completely on invalid domain names | |
227 | ||
228 | * tui: always use mail@example.invalid as default email address | |
229 | ||
230 | * run env: re-used cached version to speed up GUI installer start | |
231 | ||
232 | * log: record when and that the log got initialized and add some more | |
233 | logging, especially at start up | |
234 | ||
235 | * tui: improve ipv6 handling | |
236 | ||
237 | * tui: focus next button by default | |
238 | ||
239 | -- Proxmox Support Team <support@proxmox.com> Wed, 21 Jun 2023 18:42:27 +0200 | |
240 | ||
bd6a3424 TL |
241 | proxmox-installer (8.0.5) bookworm; urgency=medium |
242 | ||
243 | * various fixes for the TUI: | |
244 | - make HVM extension not being present a non-fatal warning | |
245 | - do not fail completely on invalid domain names | |
246 | - make disk swap-, max-root-, max-data- and min-lvm-free-size optional | |
247 | falling back to the proxinstall automatic smart defaults in that case. | |
248 | - make auto-deteced network routes optional | |
249 | - skip serializing empty fields for install config | |
250 | - set detected keyboard layout at installer launch | |
251 | - only focus summary table if it can be scrolled | |
252 | - refresh summary view if it is switched back to | |
253 | - make reboot-after-install checkbox default to enabled | |
254 | - redirect TUI stderr output to tty2 | |
255 | - use non-slanted logo | |
256 | - implement auto-reboot after installation | |
257 | ||
258 | * config: fix missing include of Log module and avoid warning if no country | |
259 | was detected | |
260 | ||
261 | * run env: make addresses optional, include all interfaces | |
262 | ||
263 | * fix #4643: show a confirmation dialog when clicking abort | |
264 | ||
265 | -- Proxmox Support Team <support@proxmox.com> Wed, 21 Jun 2023 13:22:38 +0200 | |
266 | ||
1de369c5 TL |
267 | proxmox-installer (8.0.4) bookworm; urgency=medium |
268 | ||
269 | * re-add Encode module for decoding EULA in GTK installer | |
270 | ||
271 | -- Proxmox Support Team <support@proxmox.com> Tue, 20 Jun 2023 22:02:57 +0200 | |
272 | ||
7e85b1e5 TL |
273 | proxmox-installer (8.0.3) bookworm; urgency=medium |
274 | ||
275 | * switch to native versioning | |
276 | ||
277 | * Add Terminal User Interface (TUI) based installer written in Rust, using | |
278 | the Cursive toolkit. | |
279 | ||
280 | * A variety of fixes and refactoring to prepare for more flexible ways of | |
281 | triggering an installation | |
282 | ||
283 | -- Proxmox Support Team <support@proxmox.com> Tue, 20 Jun 2023 21:37:09 +0200 | |
284 | ||
37724441 TL |
285 | proxmox-installer (8.0-2) bookworm; urgency=medium |
286 | ||
287 | * fix call to logical_blocksize | |
288 | ||
289 | -- Proxmox Support Team <support@proxmox.com> Fri, 09 Jun 2023 11:16:18 +0200 | |
290 | ||
c017c55e | 291 | proxmox-installer (8.0-1) bookworm; urgency=medium |
21757a99 TL |
292 | |
293 | * fix typo in error message | |
294 | ||
295 | * checktime: output expected and wrong times for better UX | |
296 | ||
297 | * refactor and split up installer code in modules, in preparation of more | |
298 | installer modi/UIs | |
299 | ||
300 | * call Gtk3::init manually, not on perl module load | |
301 | ||
302 | * call setupcon when starting-up final installer environment, applying the | |
303 | UTF-8 charset. | |
304 | ||
c017c55e | 305 | -- Proxmox Support Team <support@proxmox.com> Fri, 09 Jun 2023 09:39:09 +0200 |
21757a99 | 306 | |
396a1ae6 TL |
307 | proxmox-installer (7.4-2) bullseye; urgency=medium |
308 | ||
309 | * d/control: depend on renamed and split-out proxmox-kernel-helper | |
310 | ||
311 | -- Proxmox Support Team <support@proxmox.com> Mon, 20 Mar 2023 21:15:56 +0100 | |
312 | ||
5fd83fe2 TL |
313 | proxmox-installer (7.4-1) bullseye; urgency=medium |
314 | ||
315 | * zfs: fix wrong command reference in error message | |
316 | ||
317 | * parition boot disk: use 1 GiB for ESP if root disk has 100+ GB space | |
318 | ||
319 | * fix #4430: allow users to select the UTC timezone | |
320 | ||
321 | -- Proxmox Support Team <support@proxmox.com> Thu, 16 Mar 2023 12:40:57 +0100 | |
322 | ||
3766f6ab TL |
323 | proxmox-installer (7.3-1) bullseye; urgency=medium |
324 | ||
ce8e7a45 | 325 | * lvm create: improve rounding of target root LV size by aligning it down to |
3766f6ab TL |
326 | the 4MB boundary to ensure that LVM doesn't try to over allocates by one |
327 | extent. | |
328 | ||
ce8e7a45 TL |
329 | * align computed swap size down to 4 MB to avoid oddly specific sizes and |
330 | issues with LVM rounding PEs up on creation | |
331 | ||
332 | * lvm create: leave 4 MB space unallocated space for small disks (<= 32GB) | |
333 | too | |
334 | ||
335 | -- Proxmox Support Team <support@proxmox.com> Tue, 29 Nov 2022 07:24:09 +0100 | |
3766f6ab | 336 | |
7bf9ff28 TL |
337 | proxmox-installer (7.2-3) bullseye; urgency=medium |
338 | ||
339 | * create lvm: improve rounding/alignment | |
340 | ||
341 | -- Proxmox Support Team <support@proxmox.com> Fri, 18 Nov 2022 16:51:40 +0100 | |
342 | ||
f1bde6ef TL |
343 | proxmox-installer (7.2-1) bullseye; urgency=medium |
344 | ||
345 | * zfs compression - fix wrongly added zle option | |
346 | ||
347 | * fix #4236: split disk space check into soft and hard limits, warn | |
348 | below 8 GB but only hard fail on 2 GB - which can never work | |
349 | ||
350 | * fine tune swap selection for low memory/space setups | |
351 | ||
352 | * lvm create: rework auto-space distribution and improve for low size | |
353 | setups. Avoid a per-default extra free space block if the disk has | |
354 | less than 32 GB of total space. Use the full rest size for root if | |
355 | it's below 12 GB, not much of a point in setting up a data thin LVM | |
356 | for guests then. Then also show a display message if no thin LVM is | |
357 | created to inform the admin. | |
358 | ||
359 | -- Proxmox Support Team <support@proxmox.com> Fri, 18 Nov 2022 10:44:33 +0100 | |
360 | ||
3aa883ea TL |
361 | proxmox-installer (7.1-2) bullseye; urgency=medium |
362 | ||
363 | * disks: raid: avoid restting hdsize when reopening options | |
364 | ||
365 | * drop trying to enable timesyncd, wrong since chrony switch & unnecessary | |
366 | anyway | |
367 | ||
368 | * remove /mnt/hostrun after install to avoid lingering directory | |
369 | ||
370 | -- Proxmox Support Team <support@proxmox.com> Thu, 28 Apr 2022 08:08:47 +0200 | |
371 | ||
5e299512 TL |
372 | proxmox-installer (7.1-1) bullseye; urgency=medium |
373 | ||
374 | * init: | |
375 | + add missing newline for chorny log message | |
376 | + add hint that GUI should start and where to find potential errors | |
377 | + do not sync on actual reboot, was already done after installation | |
378 | finished | |
379 | ||
380 | * proxmox-boot-preparation: add newline to /etc/kernel/cmdline | |
381 | ||
382 | * display disk size with 2 decimal places | |
383 | ||
384 | * zfs create: default to relatime | |
385 | ||
386 | * fix #3905: allow lze/gzip/zstd compression for ZFS | |
387 | ||
388 | * zfs: allow RAID0 with different-sized disks | |
389 | ||
390 | * fix #3188: update hdsize spin-button on disk-selection change | |
391 | ||
392 | * fix #3587: make hdsize configurable for btrfs setups | |
393 | ||
394 | -- Proxmox Support Team <support@proxmox.com> Wed, 20 Apr 2022 14:17:52 +0200 | |
395 | ||
0761f0a7 TL |
396 | proxmox-installer (7.0-7) bullseye; urgency=medium |
397 | ||
398 | * Revert "bridged network: set bridge HW-address to port one", to subtle to | |
399 | do as static configuration | |
400 | ||
401 | * avoid copying packages into ram, bind-mount into target chroot and extract | |
402 | directly | |
403 | ||
404 | * unconfigured: avoid doing the reset "sysrq" if possible, prefer a normal | |
405 | reboot system call. | |
406 | ||
407 | -- Proxmox Support Team <support@proxmox.com> Wed, 14 Jul 2021 12:16:27 +0200 | |
408 | ||
8fc0b963 | 409 | proxmox-installer (7.0-6) bullseye; urgency=medium |
87da13d0 TL |
410 | |
411 | * bridged network: set bridge HW-address (MAC) to the one of the physical | |
412 | port | |
413 | ||
414 | * unconfigured: ifupdown is not used anymore, cope with that | |
415 | ||
416 | * unconfigured: do not unmount /dev to early on shutdown | |
417 | ||
418 | * unconfigured: only log about swap if there's actually one we can deactivate | |
419 | ||
8fc0b963 | 420 | -- Proxmox Support Team <support@proxmox.com> Mon, 12 Jul 2021 13:21:09 +0200 |
87da13d0 | 421 | |
21d7be6e TL |
422 | proxmox-installer (7.0-4) bullseye; urgency=medium |
423 | ||
424 | * clean disk: sort blockdevs by length to clean depth-first | |
425 | ||
426 | * lvcreate: pass --yes to ensure wipesignatures is answered with go- | |
427 | for-it | |
428 | ||
429 | * try to make LVM less noisy regarding leaked file-descriptors | |
430 | ||
431 | * network: sync bridge option names with pve-common | |
432 | ||
433 | -- Proxmox Support Team <support@proxmox.com> Thu, 24 Jun 2021 11:04:45 +0200 | |
434 | ||
f6af796e TL |
435 | proxmox-installer (7.0-3) bullseye; urgency=medium |
436 | ||
437 | * pid1: shutdown: send a more friendly TERM signal first | |
438 | ||
439 | * Proxmox VE: enable BTRFS support on installation as technology preview | |
440 | ||
441 | -- Proxmox Support Team <support@proxmox.com> Wed, 23 Jun 2021 23:03:22 +0200 | |
442 | ||
c930ad75 TL |
443 | proxmox-installer (7.0-2) bullseye; urgency=medium |
444 | ||
445 | * lvm: always tell lvm to wipe the signatures | |
446 | ||
447 | * clean disk: pass all partitions separately to wipe2fs, as else it won't | |
448 | bother cleaning up child ones | |
449 | ||
450 | * disk preparation: make progress report for cleaning up disks slightly more | |
451 | granular | |
452 | ||
453 | * unconfigured: handle being the new PID 1 | |
454 | ||
455 | * unconfigured: heuristically detect high-dpi and adapt debugshell font and | |
456 | GDK_SCALE for the wizard in that case | |
457 | ||
458 | -- Proxmox Support Team <support@proxmox.com> Tue, 15 Jun 2021 15:07:04 +0200 | |
459 | ||
7bd5f9b4 TL |
460 | proxmox-installer (7.0-1) bullseye; urgency=medium |
461 | ||
462 | * unify installer packages into single binary-package | |
463 | ||
464 | * use wipefs to really clean the disks used for the root filesystem, as with | |
465 | wiping only the partions through sgdik, things like LVS refuse to operate | |
466 | if they find traces of existing LVs. | |
467 | ||
468 | * override grub default config via installer instead of separate grub | |
469 | package | |
470 | ||
471 | * re-build for Debian 11 Bullseye based releases | |
472 | ||
473 | -- Proxmox Support Team <support@proxmox.com> Tue, 25 May 2021 19:54:34 +0200 | |
474 | ||
61f260bf TL |
475 | pve-installer (6.4-2) pmg pve; urgency=medium |
476 | ||
477 | * zfs: assume that all devices are boot devices as firmware is weird and | |
478 | sometimes allows booting only from certain devices, which we cannot know | |
479 | here, and potentially only the boot partition could be corrupted/broken/... | |
480 | in which case another dev in the raid 0 could allow successful booting | |
481 | ||
482 | * legacy BIOS: boot ZFS indirectly using proxmox-boot-tool and the vfat based | |
483 | ESP as the primary boot partition to avoid issues with the ZFS | |
484 | implementation of GRUB. | |
485 | ||
486 | -- Proxmox Support Team <support@proxmox.com> Mon, 26 Apr 2021 18:53:55 +0200 | |
487 | ||
6d352d07 TL |
488 | pve-installer (6.4-1) pmg pve; urgency=medium |
489 | ||
490 | * fix #2518: disk selector: add "deselect all" button if there are | |
491 | more than three disks | |
492 | ||
493 | * avoid triggering keyboard layout auto-selection heuristic if it was | |
494 | changed explicitly | |
495 | ||
496 | * partially fix #2804: set debug-console keymap on language selection | |
497 | ||
498 | * fix #3223: fix hardcoded port value in success page html | |
499 | ||
500 | * fix #3165: start chrony after DHCP client for an opportunistic time-sync | |
501 | ||
811e0e6d | 502 | -- Proxmox Support Team <support@proxmox.com> Fri, 26 Mar 2021 19:47:08 +0100 |
6d352d07 | 503 | |
e93199d2 TL |
504 | pve-installer (6.3-2) pmg pve; urgency=medium |
505 | ||
506 | * minor spelling/grammar fixes all over the place | |
507 | ||
508 | * do not configure VT keyboard layout during installation, may hang the | |
509 | installer | |
510 | ||
511 | -- Proxmox Support Team <support@proxmox.com> Tue, 10 Nov 2020 15:03:14 +0100 | |
512 | ||
7dc66ff7 TL |
513 | pve-installer (6.3-1) pmg pve; urgency=medium |
514 | ||
515 | * fix #2925: edit /etc/kernel/cmdline unconditionally | |
516 | ||
517 | * set console keymap on language selection | |
518 | ||
519 | * fix #3057: remove ext3 option from installer | |
520 | ||
521 | * pbs: actually write out email to user.cfg | |
522 | ||
523 | * network: replace dot notation netmask with CIDR notation as primary input | |
524 | ||
525 | * fix #3093: allow one to automatically reboot on installation success | |
526 | ||
527 | -- Proxmox Support Team <support@proxmox.com> Sun, 08 Nov 2020 19:35:45 +0100 | |
528 | ||
86ebed3b TL |
529 | pve-installer (6.2-3) pmg pve; urgency=medium |
530 | ||
531 | * fix #2804: add a root shell on tty3 | |
532 | ||
533 | * pbs: update installation html texts | |
534 | ||
535 | -- Proxmox Support Team <support@proxmox.com> Tue, 07 Jul 2020 15:37:04 +0200 | |
536 | ||
ba0efb12 TL |
537 | pve-installer (6.2-2) pmg pve; urgency=medium |
538 | ||
539 | * write out network configuration in CIDR notation | |
540 | ||
541 | * create default DS | |
542 | ||
543 | -- Proxmox Support Team <support@proxmox.com> Mon, 25 May 2020 21:10:33 +0200 | |
544 | ||
c9605974 TL |
545 | pve-installer (6.2-1) pmg pve; urgency=medium |
546 | ||
547 | * unconfigured: don't trap "bad" debug-shell exits | |
548 | ||
549 | -- Proxmox Support Team <support@proxmox.com> Sun, 10 May 2020 21:21:10 +0200 | |
550 | ||
528e9761 TL |
551 | pve-installer (6.1-4) pmg pve; urgency=medium |
552 | ||
553 | * unconfigured: allow pseudo terminals, mount devpts | |
554 | ||
555 | * start installer window always in full screen mode | |
556 | ||
557 | * improve spice integration | |
558 | ||
559 | -- Proxmox Support Team <support@proxmox.com> Fri, 24 Apr 2020 19:40:23 +0200 | |
560 | ||
b2713661 TL |
561 | pve-installer (6.1-3) pmg pve; urgency=medium |
562 | ||
563 | * fix behavior if ZFS disks have no /dev/by-id path | |
564 | ||
565 | * restrict admin email to same format as the JSONSchema | |
566 | ||
567 | -- Proxmox Support Team <support@proxmox.com> Fri, 06 Mar 2020 10:57:49 +0100 | |
568 | ||
b3afd5d1 TL |
569 | pve-installer (6.1-2) pmg pve; urgency=medium |
570 | ||
571 | * add all ZFS vdevs with stable by-id device path | |
572 | ||
573 | * fix #1211: allow installation on 4k-native (4kn) disks booting with UEFI | |
574 | ||
575 | -- Proxmox Support Team <support@proxmox.com> Wed, 27 Nov 2019 19:20:45 +0100 | |
576 | ||
860f938d TL |
577 | pve-installer (6.1-1) pmg pve; urgency=medium |
578 | ||
579 | * raise postifx main.cf compatibility_level to 2 | |
580 | ||
581 | * ensure /etc/aliases.db is generated | |
582 | ||
583 | -- Proxmox Support Team <support@proxmox.com> Wed, 20 Nov 2019 10:35:42 +0100 | |
584 | ||
0b4a801d TL |
585 | pve-installer (6.0-9) pmg pve; urgency=medium |
586 | ||
587 | * fix #2313: load country.dat file with utf8 encoding | |
588 | ||
589 | -- Proxmox Support Team <support@proxmox.com> Sat, 17 Aug 2019 10:31:38 +0200 | |
590 | ||
be1a181e TL |
591 | pve-installer (6.0-8) pmg pve; urgency=medium |
592 | ||
593 | * success screen: show real final IP addr with port | |
594 | ||
595 | * handle bootloader installation errors gracefully | |
596 | ||
597 | * efiboot: remove redundant call to zz-pve-efiboot | |
598 | ||
599 | -- Proxmox Support Team <support@proxmox.com> Thu, 25 Jul 2019 12:40:37 +0200 | |
600 | ||
9b9ce0e2 TL |
601 | pve-installer (6.0-5) pmg pve; urgency=medium |
602 | ||
603 | * hd_list: skip all devices with iso9660 as FS | |
604 | ||
605 | * mount efivarfs to ensure we can read bigger EFI NVRAM backed variables | |
606 | ||
607 | * fix #1603: create a new and unique machine-id | |
608 | ||
609 | * copy /etc/hostid from installer root to target | |
610 | ||
611 | * prompt user if a vgrename is OK for exisiting 'pve'/'pmg' VGs | |
612 | ||
613 | * use pve-efiboot-tool for systemd boot ESP preparation | |
614 | ||
615 | -- Proxmox Support Team <support@proxmox.com> Thu, 11 Jul 2019 19:22:31 +0200 | |
616 | ||
0fbecc5e TL |
617 | pve-installer (6.0-4) pmg pve; urgency=medium |
618 | ||
619 | * update systemd-boot config after initializing esps | |
620 | ||
621 | * clear zpool labels on selected disks' partitions | |
622 | ||
623 | * use by-id diskpath for zpool create | |
624 | ||
625 | * warn if host memory is less than 1 GB | |
626 | ||
627 | -- Proxmox Support Team <support@proxmox.com> Thu, 04 Jul 2019 18:10:06 +0200 | |
628 | ||
1cd1a8b9 TL |
629 | pve-installer (6.0-3) pmg pve; urgency=medium |
630 | ||
631 | * add support for ZFS on EFI | |
632 | ||
633 | -- Proxmox Support Team <support@proxmox.com> Fri, 28 Jun 2019 14:03:21 +0200 | |
634 | ||
5da2ffd1 TL |
635 | pve-installer (6.0-2) pmg pve; urgency=medium |
636 | ||
637 | * add note regarding issues with ZFS on HW raid controller | |
638 | ||
639 | -- Proxmox Support Team <support@proxmox.com> Tue, 25 Jun 2019 10:27:54 +0200 | |
640 | ||
c5c6fe94 TL |
641 | pve-installer (6.0-1) pmg pve; urgency=medium |
642 | ||
643 | * bump for Debian Buster | |
644 | ||
645 | -- Proxmox Support Team <support@proxmox.com> Wed, 22 May 2019 10:02:08 +0200 | |
646 | ||
89aa55e2 TL |
647 | pve-installer (5.0-26) unstable; urgency=medium |
648 | ||
649 | * ipconf view: only (re)set fields if nic really changed | |
650 | ||
651 | -- Proxmox Support Team <support@proxmox.com> Wed, 20 Mar 2019 14:39:35 +0100 | |
652 | ||
e5ef2909 TL |
653 | pve-installer (5.0-25) unstable; urgency=medium |
654 | ||
655 | * add support for Citrix Hypervisor blockdev | |
656 | ||
657 | * Fix #2009: Recreate hdsize_adj with new hdsize | |
658 | ||
659 | * implement previous button | |
660 | ||
661 | * implement summary/acknowledgement screen | |
662 | ||
663 | -- Proxmox Support Team <support@proxmox.com> Thu, 14 Mar 2019 16:36:13 +0100 | |
664 | ||
f20832ec TL |
665 | pve-installer (5.0-24) unstable; urgency=medium |
666 | ||
667 | * change last button to 'Install' | |
668 | ||
669 | * Reset adjustment for spinbutton_hdsize | |
670 | ||
671 | -- Proxmox Support Team <support@proxmox.com> Fri, 30 Nov 2018 16:09:14 +0100 | |
672 | ||
702e9890 TL |
673 | pve-installer (5.0-23) unstable; urgency=medium |
674 | ||
675 | * do not create a swap zvol | |
676 | ||
677 | * unify and adapt disk partitioning | |
678 | ||
679 | * fix #1527: Use 'iso-codes' package country naming | |
680 | ||
681 | * allow more than 26 SCSI disk devices. | |
682 | ||
683 | * fix various grammar and spelling errors | |
684 | ||
685 | -- Proxmox Support Team <support@proxmox.com> Fri, 23 Nov 2018 09:49:44 +0100 | |
686 | ||
af0245d1 FG |
687 | pve-installer (5.0-22) unstable; urgency=medium |
688 | ||
689 | * fix #1241: ensure at least 1G of thinpool metadata | |
690 | ||
691 | * handle swapsize=0 correctly | |
692 | ||
693 | * handle maxvz=0 correctly | |
694 | ||
695 | * handle minfree=0 correctly | |
696 | ||
697 | * handle local-only LVM setup | |
698 | ||
699 | -- Proxmox Support Team <support@proxmox.com> Fri, 11 May 2018 13:17:42 +0200 | |
700 | ||
b55d21e5 DM |
701 | pve-installer (5.0-21) unstable; urgency=medium |
702 | ||
703 | * ipconf.htm: remove pve product name | |
704 | ||
705 | -- Proxmox Support Team <support@proxmox.com> Mon, 22 Jan 2018 07:57:26 +0100 | |
706 | ||
ed956793 DM |
707 | pve-installer (5.0-20) unstable; urgency=medium |
708 | ||
709 | * proxinstall: only display option maxroot for product pve | |
710 | ||
711 | -- Proxmox Support Team <support@proxmox.com> Fri, 22 Dec 2017 07:43:41 +0100 | |
712 | ||
7d865b96 DM |
713 | pve-installer (5.0-19) unstable; urgency=medium |
714 | ||
715 | * allow all valid netmasks | |
716 | ||
717 | * html-pmg/extract1-license.htm: fix typo | |
718 | ||
719 | -- Proxmox Support Team <support@proxmox.com> Thu, 14 Dec 2017 11:19:10 +0100 | |
720 | ||
85cb5a90 DM |
721 | pve-installer (5.0-18) unstable; urgency=medium |
722 | ||
723 | * proxinstall - only creat ezfs data pool for product pve | |
724 | ||
725 | -- Proxmox Support Team <support@proxmox.com> Thu, 23 Nov 2017 09:53:18 +0100 | |
726 | ||
0c9c14e2 DM |
727 | pve-installer (5.0-17) unstable; urgency=medium |
728 | ||
729 | * include svg files for installer banner | |
730 | ||
731 | -- Proxmox Support Team <support@proxmox.com> Wed, 22 Nov 2017 13:12:25 +0100 | |
732 | ||
dd3eeeab DM |
733 | pve-installer (5.0-16) unstable; urgency=medium |
734 | ||
735 | * pmg: fix lvm volume sizes | |
736 | ||
737 | -- Proxmox Support Team <support@proxmox.com> Wed, 22 Nov 2017 10:26:38 +0100 | |
738 | ||
1ec71724 DM |
739 | pve-installer (5.0-15) unstable; urgency=medium |
740 | ||
741 | * dispaly info pages for 15 seconds | |
742 | ||
743 | * Revert "change clamav daily database name to daily.cld" | |
744 | ||
745 | -- Proxmox Support Team <support@proxmox.com> Wed, 22 Nov 2017 09:29:16 +0100 | |
746 | ||
96d83f35 DM |
747 | pve-installer (5.0-14) unstable; urgency=medium |
748 | ||
749 | * correctly set PermitRootLogin in sshd_config | |
750 | ||
751 | -- Proxmox Support Team <support@proxmox.com> Tue, 21 Nov 2017 14:15:16 +0100 | |
752 | ||
4c2b1ec1 DM |
753 | pve-installer (5.0-13) unstable; urgency=medium |
754 | ||
755 | * change clamav daily database name to daily.cld | |
756 | ||
757 | -- Proxmox Support Team <support@proxmox.com> Tue, 21 Nov 2017 12:31:13 +0100 | |
758 | ||
5993c2ad DM |
759 | pve-installer (5.0-12) unstable; urgency=medium |
760 | ||
761 | * pmg: write admin email to /etc/pmg/pmg.conf | |
762 | ||
763 | -- Proxmox Support Team <support@proxmox.com> Tue, 21 Nov 2017 10:26:59 +0100 | |
764 | ||
9ae645db DM |
765 | pve-installer (5.0-11) unstable; urgency=medium |
766 | ||
767 | * pmg: write user.conf to correct location | |
768 | ||
769 | -- Proxmox Support Team <support@proxmox.com> Tue, 21 Nov 2017 09:56:40 +0100 | |
770 | ||
5e49692c DM |
771 | pve-installer (5.0-10) unstable; urgency=medium |
772 | ||
773 | * bump version for testing | |
774 | ||
775 | * implement proxmox mail gateway installation | |
776 | ||
777 | -- Proxmox Support Team <support@proxmox.com> Tue, 21 Nov 2017 08:05:02 +0100 | |
778 | ||
a8213c0e DM |
779 | pve-installer (5.0-8) unstable; urgency=medium |
780 | ||
781 | * add support for multiple products (pve, pmg) | |
782 | ||
783 | -- Proxmox Support Team <support@proxmox.com> Mon, 20 Nov 2017 12:47:44 +0100 | |
784 | ||
971d9294 FG |
785 | pve-installer (5.0-7) unstable; urgency=medium |
786 | ||
787 | * kill dhclient before rebooting | |
788 | ||
789 | * ZFS: explicitly export rpool after installation | |
790 | ||
791 | * fix #1479: detect missing KVM support | |
792 | ||
793 | -- Proxmox Support Team <support@proxmox.com> Thu, 19 Oct 2017 10:56:30 +0200 | |
794 | ||
53351632 FG |
795 | pve-installer (5.0-6) unstable; urgency=medium |
796 | ||
797 | * fix console-setup | |
798 | ||
799 | -- Proxmox Support Team <support@proxmox.com> Thu, 10 Aug 2017 13:58:22 +0200 | |
800 | ||
b19f719f FG |
801 | pve-installer (5.0-5) unstable; urgency=medium |
802 | ||
803 | * allow installing without active network devices | |
804 | ||
805 | * fix bug in handling of invalid GeoIP results | |
806 | ||
807 | -- Proxmox Support Team <support@proxmox.com> Wed, 9 Aug 2017 09:41:36 +0200 | |
808 | ||
bba8f763 FG |
809 | pve-installer (5.0-4) unstable; urgency=medium |
810 | ||
811 | * rework password and email text | |
812 | ||
813 | -- Proxmox Support Team <support@proxmox.com> Fri, 23 Jun 2017 09:49:38 +0200 | |
814 | ||
67d55cde FG |
815 | pve-installer (5.0-3) unstable; urgency=medium |
816 | ||
817 | * let raid dialogue grow if > 4 disks | |
818 | ||
819 | * add initial check for NICs | |
820 | ||
821 | * ignore link-local addresses | |
822 | ||
823 | * clean disks prior to formatting | |
824 | ||
825 | * explicitly mount ESP as vfat | |
826 | ||
827 | * zero start of partitions after formatting disk | |
828 | ||
829 | * fix XFS mount options | |
830 | ||
831 | -- Proxmox Support Team <support@proxmox.com> Fri, 5 May 2017 12:11:22 +0200 | |
832 | ||
4f0241f1 FG |
833 | pve-installer (5.0-2) unstable; urgency=medium |
834 | ||
835 | * always select a NIC, even if DHCP fails | |
836 | ||
837 | -- Proxmox Support Team <support@proxmox.com> Tue, 14 Mar 2017 09:44:30 +0100 | |
838 | ||
64c46db3 FG |
839 | pve-installer (5.0-1) unstable; urgency=medium |
840 | ||
841 | * rebuild for PVE 5.0 | |
842 | ||
843 | * fix #1239: enhance swap on ZFS setup | |
844 | ||
845 | * use iproute2, support interface selection | |
846 | ||
847 | * get DHCP leases on all interfaces | |
848 | ||
849 | * only require grub-efi to succeed if booted using UEFI | |
850 | ||
851 | -- Proxmox Support Team <support@proxmox.com> Mon, 13 Mar 2017 13:03:43 +0100 | |
852 | ||
56635b97 DM |
853 | pve-installer (4.0-16) unstable; urgency=medium |
854 | ||
855 | * actually use more than 8 disks if selected | |
856 | ||
857 | -- Proxmox Support Team <support@proxmox.com> Thu, 15 Dec 2016 10:05:54 +0100 | |
858 | ||
f29589b4 DM |
859 | pve-installer (4.0-15) unstable; urgency=medium |
860 | ||
861 | * use explicit partition starts | |
862 | ||
863 | * bump EFI partition size to 256M | |
864 | ||
865 | * compute_swapsize: add return statement | |
866 | ||
867 | -- Proxmox Support Team <support@proxmox.com> Tue, 13 Dec 2016 09:12:20 +0100 | |
868 | ||
bb77a307 DM |
869 | pve-installer (4.0-14) unstable; urgency=medium |
870 | ||
871 | * bump version for new RELEASE=4.4 | |
872 | ||
873 | -- Proxmox Support Team <support@proxmox.com> Fri, 09 Dec 2016 12:03:00 +0100 | |
874 | ||
56445ecb DM |
875 | pve-installer (4.0-13) unstable; urgency=medium |
876 | ||
877 | * add default invalid mail address | |
878 | ||
879 | * refactor disk setup | |
880 | ||
881 | * add advanced ZFS options | |
882 | ||
883 | * fix #1190: allow ZFS mirrors with slightly different sizes | |
884 | ||
885 | -- Proxmox Support Team <support@proxmox.com> Mon, 05 Dec 2016 10:48:19 +0100 | |
886 | ||
77ebccb1 DM |
887 | pve-installer (4.0-12) unstable; urgency=medium |
888 | ||
889 | * fix update_progress while extracting files | |
890 | ||
891 | * assume root file system is writable (overlayfs) | |
892 | ||
893 | -- Proxmox Support Team <support@proxmox.com> Wed, 21 Sep 2016 13:12:33 +0200 | |
894 | ||
e11d96aa DM |
895 | pve-installer (4.0-11) unstable; urgency=medium |
896 | ||
897 | * use unsquashfs instead of tar | |
898 | ||
899 | -- Proxmox Support Team <support@proxmox.com> Wed, 31 Aug 2016 08:49:30 +0200 | |
900 | ||
26f89221 DM |
901 | pve-installer (4.0-10) unstable; urgency=medium |
902 | ||
903 | * Fix #1054: error on purely numeric hostnames | |
904 | ||
905 | * update layout, use new logo | |
906 | ||
907 | -- Proxmox Support Team <support@proxmox.com> Tue, 09 Aug 2016 09:46:31 +0200 | |
908 | ||
3885481c DM |
909 | pve-installer (4.0-8) unstable; urgency=medium |
910 | ||
911 | * restrict hdsize if requested | |
912 | ||
913 | -- Proxmox Support Team <support@proxmox.com> Sun, 06 Mar 2016 09:04:44 +0100 | |
914 | ||
5fd81672 DM |
915 | pve-installer (4.0-7) unstable; urgency=medium |
916 | ||
917 | * use lvmthin for data volume | |
918 | ||
919 | * create zfs subpool (rpool/data) as VM/CT storage | |
920 | ||
921 | * create better default storage configiguration | |
922 | ||
923 | -- Proxmox Support Team <support@proxmox.com> Tue, 01 Mar 2016 07:16:16 +0100 | |
924 | ||
0ee3ef41 DM |
925 | pve-installer (4.0-6) unstable; urgency=medium |
926 | ||
927 | * install EFI fallback boot file (OVMF does not boot without) | |
928 | ||
929 | -- Proxmox Support Team <support@proxmox.com> Thu, 10 Dec 2015 10:39:46 +0100 | |
930 | ||
6b5dc3d0 DM |
931 | pve-installer (4.0-5) unstable; urgency=medium |
932 | ||
036475a0 DM |
933 | * allow up to 8 zfs disks |
934 | ||
6b5dc3d0 DM |
935 | * enable systemd-timesyncd.service by default |
936 | ||
937 | -- Proxmox Support Team <support@proxmox.com> Fri, 20 Nov 2015 09:07:20 +0100 | |
938 | ||
1143023f DM |
939 | pve-installer (4.0-4) unstable; urgency=medium |
940 | ||
941 | * add ipv6 support | |
942 | ||
943 | -- Proxmox Support Team <support@proxmox.com> Tue, 06 Oct 2015 08:22:45 +0200 | |
944 | ||
ccac1881 DM |
945 | pve-installer (4.0-3) unstable; urgency=medium |
946 | ||
947 | * zpool create: use cachefile=none | |
948 | ||
949 | * do not mention LVM snapshots | |
950 | ||
951 | -- Proxmox Support Team <support@proxmox.com> Tue, 29 Sep 2015 12:17:57 +0200 | |
952 | ||
df482fe5 DM |
953 | pve-installer (4.0-2) unstable; urgency=medium |
954 | ||
955 | * add xfs support | |
956 | ||
957 | -- Proxmox Support Team <support@proxmox.com> Tue, 16 Jun 2015 11:57:06 +0200 | |
958 | ||
959 | pve-installer (4.0-1) unstable; urgency=medium | |
960 | ||
961 | * updates for debian jessie | |
962 | ||
963 | -- Proxmox Support Team <support@proxmox.com> Tue, 16 Jun 2015 11:56:54 +0200 | |
964 | ||
71eb60d6 DM |
965 | pve-installer (3.3-3) unstable; urgency=low |
966 | ||
967 | * support ZFS | |
968 | ||
969 | -- Proxmox Support Team <support@proxmox.com> Wed, 14 Jan 2015 09:39:28 +0100 | |
970 | ||
84761f93 DM |
971 | pve-installer (3.3-2) unstable; urgency=low |
972 | ||
973 | * support UEFI systems | |
aed81ff0 DM |
974 | |
975 | * add new 'Options' Dialog | |
84761f93 DM |
976 | |
977 | * do not install xorg.conf (not needed, and makes problems with EFI boot) | |
978 | ||
979 | -- Proxmox Support Team <support@proxmox.com> Wed, 01 Oct 2014 09:16:03 +0200 | |
980 | ||
cd0cff32 DM |
981 | pve-installer (3.3-1) unstable; urgency=low |
982 | ||
983 | * update path for 3.3 release | |
984 | ||
985 | -- Proxmox Support Team <support@proxmox.com> Mon, 08 Sep 2014 12:08:14 +0200 | |
986 | ||
987 | pve-installer (3.0-2) unstable; urgency=low | |
988 | ||
989 | * always use GUID partition tables | |
990 | ||
991 | -- Proxmox Support Team <support@proxmox.com> Thu, 09 Jan 2014 16:00:25 +0100 | |
992 | ||
24396f40 DM |
993 | pve-installer (3.0-1) unstable; urgency=low |
994 | ||
995 | * updates for debian wheezy | |
996 | ||
997 | * use webkit instead of gthhtml2 | |
998 | ||
999 | -- Proxmox Support Team <support@proxmox.com> Wed, 20 Mar 2013 06:39:42 +0100 | |
1000 | ||
87a09334 DM |
1001 | pve-installer (2.3-6) unstable; urgency=low |
1002 | ||
1003 | * fix hdsize algorythm | |
1004 | ||
1005 | -- Proxmox Support Team <support@proxmox.com> Fri, 01 Mar 2013 10:32:00 +0100 | |
1006 | ||
968fa90b DM |
1007 | pve-installer (2.0-5) unstable; urgency=low |
1008 | ||
1009 | * add 'hdsize' boot parameter to specify maximum size used. | |
1010 | ||
1011 | -- Proxmox Support Team <support@proxmox.com> Fri, 30 Nov 2012 06:18:55 +0100 | |
1012 | ||
89092156 DM |
1013 | pve-installer (2.0-4) unstable; urgency=low |
1014 | ||
1015 | * fix bug #226 && #227: new minfree and maxvz boot options | |
1016 | ||
1017 | -- Proxmox Support Team <support@proxmox.com> Wed, 18 Jul 2012 05:51:47 +0200 | |
1018 | ||
5586cedd DM |
1019 | pve-installer (2.0-3) unstable; urgency=low |
1020 | ||
1021 | * increase free space on LVM up to 16GB | |
1022 | ||
1023 | -- Proxmox Support Team <support@proxmox.com> Thu, 16 Feb 2012 11:59:55 +0100 | |
1024 | ||
89a12446 DM |
1025 | pve-installer (2.0-2) unstable; urgency=low |
1026 | ||
1027 | * support new kernel parameter 'ext4' switch (use ext4 instead of ext3) | |
1028 | ||
1029 | * use 'ext3' by default | |
1030 | ||
1031 | -- Proxmox Support Team <support@proxmox.com> Thu, 04 Aug 2011 12:58:27 +0200 | |
1032 | ||
1033 | pve-installer (2.0-1) unstable; urgency=low | |
1034 | ||
1035 | * use ext4 fs | |
1036 | ||
1037 | * align LVM on 128k boundary | |
1038 | ||
1039 | * use 'parted' to create partitions | |
1040 | ||
1041 | * support > 2TB disks (use GPT partition tables) | |
1042 | ||
1043 | * mount with barrier=0 during install (speedup) | |
1044 | ||
1045 | * write keyboard settings to /etc/pve-installer.cfg | |
1046 | ||
1047 | * adjust for pve2 | |
1048 | ||
1049 | * avoid to run update-grub or update-initramfs during install | |
1050 | ||
1051 | * use --no-triggers for faster unpack | |
1052 | ||
1053 | * also mount sysfs to /target/sys | |
1054 | ||
1055 | * do not write /etc/default/grub - not really needed | |
1056 | ||
1057 | * we now use openbox instead of metacity | |
1058 | ||
1059 | * wait one second after partitioning (give kernel time to reread part | |
1060 | table) | |
1061 | ||
1062 | * use update-initramfs -c (instead of -u) | |
1063 | ||
1064 | * do not write /etc/apache2/ports.conf (not really needed) | |
1065 | ||
1066 | * enable apache port redirect (a2ensite pve-redirect.conf) | |
1067 | ||
1068 | -- Proxmox Support Team <support@proxmox.com> Mon, 15 Feb 2010 14:09:46 +0100 | |
1069 | ||
1070 | pve-installer (1.0-9) unstable; urgency=low | |
1071 | ||
1072 | * fix netmask bug | |
1073 | ||
1074 | * use 'udevadm info' to detect disks | |
1075 | ||
1076 | -- Proxmox Support Team <support@proxmox.com> Fri, 22 Jan 2010 13:13:11 +0100 | |
1077 | ||
1078 | pve-installer (1.0-8) unstable; urgency=low | |
1079 | ||
1080 | * use UUID= for /boot in fstab | |
1081 | ||
1082 | -- Proxmox Support Team <support@proxmox.com> Fri, 22 Jan 2010 13:11:58 +0100 | |
1083 | ||
1084 | pve-installer (1.0-7) unstable; urgency=low | |
1085 | ||
1086 | * unconfigured.sh: use -q flag for modprobe | |
1087 | ||
1088 | * proxinstall: use 'removable' flag on older kernels (instead | |
1089 | of 'capability') to detect cdroms. | |
1090 | ||
1091 | -- Proxmox Support Team <support@proxmox.com> Fri, 04 Dec 2009 18:03:59 +0100 | |
1092 | ||
1093 | pve-installer (1.0-6) unstable; urgency=low | |
1094 | ||
1095 | * pass --no-floppy to grub-install (some users reported delays) | |
1096 | ||
1097 | -- Proxmox Support Team <support@proxmox.com> Fri, 19 Jun 2009 10:48:37 +0200 | |
1098 | ||
1099 | pve-installer (1.0-5) unstable; urgency=low | |
1100 | ||
1101 | * fixes for debian lenny | |
1102 | ||
1103 | * support dynamically allocated virtio blk devices | |
1104 | ||
1105 | -- Proxmox Support Team <support@proxmox.com> Fri, 08 May 2009 16:53:42 +0200 | |
1106 | ||
1107 | pve-installer (1.0-4) unstable; urgency=low | |
1108 | ||
1109 | * proxinstall: better postfix configuration | |
1110 | ||
1111 | -- Proxmox Support Team <support@proxmox.com> Mon, 12 Jan 2009 12:21:13 +0100 | |
1112 | ||
1113 | pve-installer (1.0-3) unstable; urgency=low | |
1114 | ||
1115 | * ause grub instead of lilo | |
1116 | ||
1117 | -- Proxmox Support Team <support@proxmox.com> Wed, 20 Aug 2008 14:39:57 +0200 | |
1118 | ||
1119 | pve-installer (1.0-2) stable; urgency=low | |
1120 | ||
1121 | * proxinstall (extract_data): added maxroot and swapsize boot parameters, | |
1122 | set bridge parameters (stp = on, fd = 0) | |
1123 | ||
1124 | -- Proxmox Support Team <support@proxmox.com> Tue, 8 Jul 2008 06:54:03 +0200 | |
1125 | ||
1126 | pve-installer (1.0-1) stable; urgency=low | |
1127 | ||
1128 | * initial release | |
1129 | ||
1130 | -- Proxmox Support Team <support@proxmox.com> Mon, 19 Nov 2007 15:48:05 +0100 | |
1131 |