]> git.proxmox.com Git - mirror_ubuntu-zesty-kernel.git/blame - drivers/thermal/Kconfig
thermal: Add QPNP PMIC temperature alarm driver
[mirror_ubuntu-zesty-kernel.git] / drivers / thermal / Kconfig
CommitLineData
203d3d4a
ZR
1#
2# Generic thermal sysfs drivers configuration
3#
4
5menuconfig THERMAL
63c4ec90 6 tristate "Generic Thermal sysfs driver"
203d3d4a
ZR
7 help
8 Generic Thermal Sysfs driver offers a generic mechanism for
9 thermal management. Usually it's made up of one or more thermal
10 zone and cooling device.
543a9561 11 Each thermal zone contains its own temperature, trip points,
203d3d4a
ZR
12 cooling devices.
13 All platforms with ACPI thermal support can use this driver.
63c4ec90 14 If you want this support, you should say Y or M here.
16d75239 15
72e19897
ZR
16if THERMAL
17
16d75239 18config THERMAL_HWMON
ab92402a 19 bool
0dd88793 20 prompt "Expose thermal sensors as hwmon device"
16d75239 21 depends on HWMON=y || HWMON=THERMAL
ab92402a 22 default y
0dd88793
EV
23 help
24 In case a sensor is registered with the thermal
25 framework, this option will also register it
26 as a hwmon. The sensor will then have the common
27 hwmon sysfs interface.
28
29 Say 'Y' here if you want all thermal sensors to
30 have hwmon sysfs interface too.
6a92c366 31
4e5e4705
EV
32config THERMAL_OF
33 bool
34 prompt "APIs to parse thermal data out of device tree"
35 depends on OF
36 default y
37 help
38 This options provides helpers to add the support to
39 read and parse thermal data definitions out of the
40 device tree blob.
41
42 Say 'Y' here if you need to build thermal infrastructure
43 based on device tree.
44
72e19897
ZR
45choice
46 prompt "Default Thermal governor"
47 default THERMAL_DEFAULT_GOV_STEP_WISE
48 help
49 This option sets which thermal governor shall be loaded at
50 startup. If in doubt, select 'step_wise'.
51
52config THERMAL_DEFAULT_GOV_STEP_WISE
53 bool "step_wise"
9d185d04 54 select THERMAL_GOV_STEP_WISE
72e19897
ZR
55 help
56 Use the step_wise governor as default. This throttles the
57 devices one step at a time.
58
59config THERMAL_DEFAULT_GOV_FAIR_SHARE
60 bool "fair_share"
9d185d04 61 select THERMAL_GOV_FAIR_SHARE
72e19897
ZR
62 help
63 Use the fair_share governor as default. This throttles the
64 devices based on their 'contribution' to a zone. The
65 contribution should be provided through platform data.
66
67config THERMAL_DEFAULT_GOV_USER_SPACE
68 bool "user_space"
9d185d04 69 select THERMAL_GOV_USER_SPACE
72e19897
ZR
70 help
71 Select this if you want to let the user space manage the
ece238fe 72 platform thermals.
72e19897
ZR
73
74endchoice
75
9d185d04 76config THERMAL_GOV_FAIR_SHARE
72e19897
ZR
77 bool "Fair-share thermal governor"
78 help
79 Enable this to manage platform thermals using fair-share governor.
80
9d185d04 81config THERMAL_GOV_STEP_WISE
72e19897
ZR
82 bool "Step_wise thermal governor"
83 help
84 Enable this to manage platform thermals using a simple linear
a8227948 85 governor.
72e19897 86
e4dbf98f
PF
87config THERMAL_GOV_BANG_BANG
88 bool "Bang Bang thermal governor"
89 default n
90 help
91 Enable this to manage platform thermals using bang bang governor.
92
93 Say 'Y' here if you want to use two point temperature regulation
94 used for fans without throttling. Some fan drivers depend on this
95 governor to be enabled (e.g. acerhdf).
96
9d185d04 97config THERMAL_GOV_USER_SPACE
72e19897
ZR
98 bool "User_space thermal governor"
99 help
100 Enable this to let the user space manage the platform thermals.
101
02361418 102config CPU_THERMAL
bbf7fc88 103 bool "generic cpu cooling support"
72e19897 104 depends on CPU_FREQ
39d99cff 105 depends on THERMAL_OF
02361418
ADK
106 help
107 This implements the generic cpu cooling mechanism through frequency
f7188b3d
EV
108 reduction. An ACPI version of this already exists
109 (drivers/acpi/processor_thermal.c).
02361418
ADK
110 This will be useful for platforms using the generic thermal interface
111 and not the ACPI interface.
f7188b3d 112
02361418
ADK
113 If you want this support, you should say Y here.
114
f9df89d8
EV
115config CLOCK_THERMAL
116 bool "Generic clock cooling support"
117 depends on COMMON_CLK
118 depends on PM_OPP
119 help
120 This entry implements the generic clock cooling mechanism through
121 frequency clipping. Typically used to cool off co-processors. The
122 device that is configured to use this cooling mechanism will be
123 controlled to reduce clock frequency whenever temperature is high.
124
125 If you want this support, you should say Y here.
126
e6e238c3
ADK
127config THERMAL_EMULATION
128 bool "Thermal emulation mode support"
129 help
130 Enable this option to make a emul_temp sysfs node in thermal zone
131 directory to support temperature emulation. With emulation sysfs node,
132 user can manually input temperature and test the different trip
133 threshold behaviour for simulation purpose.
134
8837295a
EV
135 WARNING: Be careful while enabling this option on production systems,
136 because userland can easily disable the thermal policy by simply
137 flooding this sysfs node with low temperature values.
138
ca3de46b
SG
139config IMX_THERMAL
140 tristate "Temperature sensor driver for Freescale i.MX SoCs"
141 depends on CPU_THERMAL
142 depends on MFD_SYSCON
143 depends on OF
144 help
145 Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
146 It supports one critical trip point and one passive trip point. The
147 cpufreq is used as the cooling device to throttle CPUs when the
148 passive trip is crossed.
149
6a92c366
VF
150config SPEAR_THERMAL
151 bool "SPEAr thermal sensor driver"
6a92c366 152 depends on PLAT_SPEAR
b9c7aff4 153 depends on OF
6a92c366
VF
154 help
155 Enable this to plug the SPEAr thermal sensor driver into the Linux
a8227948 156 thermal framework.
1e426ffd 157
cbac8f63
CW
158config ROCKCHIP_THERMAL
159 tristate "Rockchip thermal driver"
160 depends on ARCH_ROCKCHIP
161 depends on RESET_CONTROLLER
162 help
163 Rockchip thermal driver provides support for Temperature sensor
164 ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
165 trip point. Cpufreq is used as the cooling device and will throttle
166 CPUs when the Temperature crosses the passive trip point.
167
1e426ffd
KM
168config RCAR_THERMAL
169 tristate "Renesas R-Car thermal driver"
beeb5a1e 170 depends on ARCH_SHMOBILE || COMPILE_TEST
d1c8b041 171 depends on HAS_IOMEM
1e426ffd
KM
172 help
173 Enable this to plug the R-Car thermal sensor driver into the Linux
a8227948 174 thermal framework.
c48cbba6 175
7060aa36
NI
176config KIRKWOOD_THERMAL
177 tristate "Temperature sensor on Marvell Kirkwood SoCs"
575be653 178 depends on MACH_KIRKWOOD
7060aa36
NI
179 depends on OF
180 help
181 Support for the Kirkwood thermal sensor driver into the Linux thermal
182 framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
183
74ffa64c
AL
184config DOVE_THERMAL
185 tristate "Temperature sensor on Marvell Dove SoCs"
b3dee390 186 depends on ARCH_DOVE || MACH_DOVE
74ffa64c
AL
187 depends on OF
188 help
189 Support for the Dove thermal sensor driver in the Linux thermal
190 framework.
191
aa1acb04 192config DB8500_THERMAL
193 bool "DB8500 thermal management"
194 depends on ARCH_U8500
195 default y
196 help
197 Adds DB8500 thermal management implementation according to the thermal
198 management framework. A thermal zone with several trip points will be
199 created. Cooling devices can be bound to the trip points to cool this
200 thermal zone if trip points reached.
201
fa0d654c
EG
202config ARMADA_THERMAL
203 tristate "Armada 370/XP thermal management"
204 depends on ARCH_MVEBU
205 depends on OF
206 help
207 Enable this option if you want to have support for thermal management
208 controller present in Armada 370 and Armada XP SoC.
209
66fb8480
MP
210config TEGRA_SOCTHERM
211 tristate "Tegra SOCTHERM thermal management"
212 depends on ARCH_TEGRA
213 help
214 Enable this option for integrated thermal management support on NVIDIA
215 Tegra124 systems-on-chip. The driver supports four thermal zones
216 (CPU, GPU, MEM, PLLX). Cooling devices can be bound to the thermal
217 zones to manage temperatures. This option is also required for the
218 emergency thermal reset (thermtrip) feature to function.
219
aa1acb04 220config DB8500_CPUFREQ_COOLING
221 tristate "DB8500 cpufreq cooling"
222 depends on ARCH_U8500
223 depends on CPU_THERMAL
224 default y
225 help
226 Adds DB8500 cpufreq cooling devices, and these cooling devices can be
227 bound to thermal zone trip points. When a trip point reached, the
228 bound cpufreq cooling device turns active to set CPU frequency low to
229 cool down the CPU.
a56757af 230
d6d71ee4
JP
231config INTEL_POWERCLAMP
232 tristate "Intel PowerClamp idle injection driver"
233 depends on THERMAL
234 depends on X86
235 depends on CPU_SUP_INTEL
236 help
237 Enable this to enable Intel PowerClamp idle injection driver. This
238 enforce idle time which results in more package C-state residency. The
239 user interface is exposed via generic thermal framework.
240
f1a18a10
SP
241config X86_PKG_TEMP_THERMAL
242 tristate "X86 package temperature thermal driver"
b3ba0206 243 depends on X86_THERMAL_VECTOR
f1a18a10
SP
244 select THERMAL_GOV_USER_SPACE
245 default m
246 help
247 Enable this to register CPU digital sensor for package temperature as
248 thermal zone. Each package will have its own thermal zone. There are
249 two trip points which can be set by user to get notifications via thermal
250 notification methods.
251
bc40b5e3
SP
252config INTEL_SOC_DTS_THERMAL
253 tristate "Intel SoCs DTS thermal driver"
254 depends on X86 && IOSF_MBI
255 help
256 Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
257 temperature sensor (DTS). These SoCs have two additional DTSs in
258 addition to DTSs on CPU cores. Each DTS will be registered as a
259 thermal zone. There are two trip points. One of the trip point can
260 be set by user mode programs to get notifications via Linux thermal
261 notification methods.The other trip is a critical trip point, which
262 was set by the driver based on the TJ MAX temperature.
263
3230bbfc 264config INT340X_THERMAL
816cab93 265 tristate "ACPI INT340X thermal drivers"
3230bbfc 266 depends on X86 && ACPI
0ab15365 267 select THERMAL_GOV_USER_SPACE
52b1c69d 268 select ACPI_THERMAL_REL
d8054749 269 select ACPI_FAN
3230bbfc
ZR
270 help
271 Newer laptops and tablets that use ACPI may have thermal sensors and
272 other devices with thermal control capabilities outside the core
273 CPU/SOC, for thermal safety reasons.
274 They are exposed for the OS to use via the INT3400 ACPI device object
275 as the master, and INT3401~INT340B ACPI device objects as the slaves.
276 Enable this to expose the temperature information and cooling ability
277 from these objects to userspace via the normal thermal framework.
278 This means that a wide range of applications and GUI widgets can show
279 the information to the user or use this information for making
280 decisions. For example, the Intel Thermal Daemon can use this
281 information to allow the user to select his laptop to run without
282 turning on the fans.
283
52b1c69d
JP
284config ACPI_THERMAL_REL
285 tristate
286 depends on ACPI
287
eb982001
EV
288menu "Texas Instruments thermal drivers"
289source "drivers/thermal/ti-soc-thermal/Kconfig"
290endmenu
f157f596 291
c6821378 292menu "Samsung thermal drivers"
4de45817 293depends on ARCH_EXYNOS
c6821378
ADK
294source "drivers/thermal/samsung/Kconfig"
295endmenu
296
60aef7ce
LJ
297menu "STMicroelectronics thermal drivers"
298depends on ARCH_STI && OF
299source "drivers/thermal/st/Kconfig"
300endmenu
301
c610afaa
II
302config QCOM_SPMI_TEMP_ALARM
303 tristate "Qualcomm SPMI PMIC Temperature Alarm"
304 depends on OF && SPMI && IIO
305 select REGMAP_SPMI
306 help
307 This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
308 PMIC devices. It shows up in sysfs as a thermal sensor with multiple
309 trip points. The temperature reported by the thermal sensor reflects the
310 real time die temperature if an ADC is present or an estimate of the
311 temperature based upon the over temperature stage value.
312
72e19897 313endif