]> git.proxmox.com Git - mirror_ubuntu-hirsute-kernel.git/blob - Documentation/hwmon/tps53679.rst
Merge tag 'scsi-misc' of git://git.kernel.org/pub/scm/linux/kernel/git/jejb/scsi
[mirror_ubuntu-hirsute-kernel.git] / Documentation / hwmon / tps53679.rst
1 Kernel driver tps53679
2 ======================
3
4 Supported chips:
5
6 * Texas Instruments TPS53647
7
8 Prefix: 'tps53647'
9
10 Addresses scanned: -
11
12 Datasheet: https://www.ti.com/lit/gpn/tps53647
13
14 * Texas Instruments TPS53667
15
16 Prefix: 'tps53667'
17
18 Addresses scanned: -
19
20 Datasheet: https://www.ti.com/lit/gpn/TPS53667
21
22 * Texas Instruments TPS53679
23
24 Prefix: 'tps53679'
25
26 Addresses scanned: -
27
28 Datasheet: https://www.ti.com/lit/gpn/TPS53679 (short version)
29
30 * Texas Instruments TPS53681
31
32 Prefix: 'tps53681'
33
34 Addresses scanned: -
35
36 Datasheet: https://www.ti.com/lit/gpn/TPS53681
37
38 * Texas Instruments TPS53688
39
40 Prefix: 'tps53688'
41
42 Addresses scanned: -
43
44 Datasheet: Available under NDA
45
46
47 Authors:
48 Vadim Pasternak <vadimp@mellanox.com>
49 Guenter Roeck <linux@roeck-us.net>
50
51
52 Description
53 -----------
54
55 Chips in this series are multi-phase step-down converters with one or two
56 output channels and up to 8 phases per channel.
57
58
59 Usage Notes
60 -----------
61
62 This driver does not probe for PMBus devices. You will have to instantiate
63 devices explicitly.
64
65 Example: the following commands will load the driver for an TPS53681 at address
66 0x60 on I2C bus #1::
67
68 # modprobe tps53679
69 # echo tps53681 0x60 > /sys/bus/i2c/devices/i2c-1/new_device
70
71
72 Sysfs attributes
73 ----------------
74
75 ======================= ========================================================
76 in1_label "vin"
77
78 in1_input Measured input voltage.
79
80 in1_lcrit Critical minimum input voltage
81
82 TPS53679, TPS53681, TPS53688 only.
83
84 in1_lcrit_alarm Input voltage critical low alarm.
85
86 TPS53679, TPS53681, TPS53688 only.
87
88 in1_crit Critical maximum input voltage.
89
90 in1_crit_alarm Input voltage critical high alarm.
91
92 in[N]_label "vout[1-2]"
93
94 - TPS53647, TPS53667: N=2
95 - TPS53679, TPS53588: N=2,3
96
97 in[N]_input Measured output voltage.
98
99 in[N]_lcrit Critical minimum input voltage.
100
101 TPS53679, TPS53681, TPS53688 only.
102
103 in[N]_lcrit_alarm Critical minimum voltage alarm.
104
105 TPS53679, TPS53681, TPS53688 only.
106
107 in[N]_alarm Output voltage alarm.
108
109 TPS53647, TPS53667 only.
110
111 in[N]_crit Critical maximum output voltage.
112
113 TPS53679, TPS53681, TPS53688 only.
114
115 in[N]_crit_alarm Output voltage critical high alarm.
116
117 TPS53679, TPS53681, TPS53688 only.
118
119 temp[N]_input Measured temperature.
120
121 - TPS53647, TPS53667: N=1
122 - TPS53679, TPS53681, TPS53588: N=1,2
123
124 temp[N]_max Maximum temperature.
125
126 temp[N]_crit Critical high temperature.
127
128 temp[N]_max_alarm Temperature high alarm.
129
130 temp[N]_crit_alarm Temperature critical high alarm.
131
132 power1_label "pin".
133
134 power1_input Measured input power.
135
136 power[N]_label "pout[1-2]".
137
138 - TPS53647, TPS53667: N=2
139 - TPS53679, TPS53681, TPS53588: N=2,3
140
141 power[N]_input Measured output power.
142
143 curr1_label "iin".
144
145 curr1_input Measured input current.
146
147 curr1_max Maximum input current.
148
149 curr1_max_alarm Input current high alarm.
150
151 curr1_crit Critical input current.
152
153 curr1_crit_alarm Input current critical alarm.
154
155 curr[N]_label "iout[1-2]" or "iout1.[0-5]".
156
157 The first digit is the output channel, the second
158 digit is the phase within the channel. Per-phase
159 telemetry supported on TPS53681 only.
160
161 - TPS53647, TPS53667: N=2
162 - TPS53679, TPS53588: N=2,3
163 - TPS53681: N=2-9
164
165 curr[N]_input Measured output current.
166
167 curr[N]_max Maximum output current.
168
169 curr[N]_crit Critical high output current.
170
171 curr[N]_max_alarm Output current high alarm.
172
173 curr[N]_crit_alarm Output current critical high alarm.
174
175 Limit and alarm attributes are only available for