]> git.proxmox.com Git - mirror_ovs.git/blob - INSTALL.DPDK.md
datapath-windows: Fix IP fragmentation
[mirror_ovs.git] / INSTALL.DPDK.md
1 Using Open vSwitch with DPDK
2 ============================
3
4 Open vSwitch can use Intel(R) DPDK lib to operate entirely in
5 userspace. This file explains how to install and use Open vSwitch in
6 such a mode.
7
8 The DPDK support of Open vSwitch is considered experimental.
9 It has not been thoroughly tested.
10
11 This version of Open vSwitch should be built manually with `configure`
12 and `make`.
13
14 OVS needs a system with 1GB hugepages support.
15
16 Building and Installing:
17 ------------------------
18
19 Required: DPDK 2.1
20 Optional (if building with vhost-cuse): `fuse`, `fuse-devel` (`libfuse-dev`
21 on Debian/Ubuntu)
22
23 1. Configure build & install DPDK:
24 1. Set `$DPDK_DIR`
25
26 ```
27 export DPDK_DIR=/usr/src/dpdk-2.1
28 cd $DPDK_DIR
29 ```
30
31 2. Update `config/common_linuxapp` so that DPDK generate single lib file.
32 (modification also required for IVSHMEM build)
33
34 `CONFIG_RTE_BUILD_COMBINE_LIBS=y`
35
36 Then run `make install` to build and install the library.
37 For default install without IVSHMEM:
38
39 `make install T=x86_64-native-linuxapp-gcc`
40
41 To include IVSHMEM (shared memory):
42
43 `make install T=x86_64-ivshmem-linuxapp-gcc`
44
45 For further details refer to http://dpdk.org/
46
47 2. Configure & build the Linux kernel:
48
49 Refer to intel-dpdk-getting-started-guide.pdf for understanding
50 DPDK kernel requirement.
51
52 3. Configure & build OVS:
53
54 * Non IVSHMEM:
55
56 `export DPDK_BUILD=$DPDK_DIR/x86_64-native-linuxapp-gcc/`
57
58 * IVSHMEM:
59
60 `export DPDK_BUILD=$DPDK_DIR/x86_64-ivshmem-linuxapp-gcc/`
61
62 ```
63 cd $(OVS_DIR)/openvswitch
64 ./boot.sh
65 ./configure --with-dpdk=$DPDK_BUILD [CFLAGS="-g -O2 -Wno-cast-align"]
66 make
67 ```
68
69 Note: 'clang' users may specify the '-Wno-cast-align' flag to suppress DPDK cast-align warnings.
70
71 To have better performance one can enable aggressive compiler optimizations and
72 use the special instructions(popcnt, crc32) that may not be available on all
73 machines. Instead of typing `make`, type:
74
75 `make CFLAGS='-O3 -march=native'`
76
77 Refer to [INSTALL.userspace.md] for general requirements of building userspace OVS.
78
79 Using the DPDK with ovs-vswitchd:
80 ---------------------------------
81
82 1. Setup system boot
83 Add the following options to the kernel bootline:
84
85 `default_hugepagesz=1GB hugepagesz=1G hugepages=1`
86
87 2. Setup DPDK devices:
88
89 DPDK devices can be setup using either the VFIO (for DPDK 1.7+) or UIO
90 modules. UIO requires inserting an out of tree driver igb_uio.ko that is
91 available in DPDK. Setup for both methods are described below.
92
93 * UIO:
94 1. insert uio.ko: `modprobe uio`
95 2. insert igb_uio.ko: `insmod $DPDK_BUILD/kmod/igb_uio.ko`
96 3. Bind network device to igb_uio:
97 `$DPDK_DIR/tools/dpdk_nic_bind.py --bind=igb_uio eth1`
98
99 * VFIO:
100
101 VFIO needs to be supported in the kernel and the BIOS. More information
102 can be found in the [DPDK Linux GSG].
103
104 1. Insert vfio-pci.ko: `modprobe vfio-pci`
105 2. Set correct permissions on vfio device: `sudo /usr/bin/chmod a+x /dev/vfio`
106 and: `sudo /usr/bin/chmod 0666 /dev/vfio/*`
107 3. Bind network device to vfio-pci:
108 `$DPDK_DIR/tools/dpdk_nic_bind.py --bind=vfio-pci eth1`
109
110 3. Mount the hugetable filesystem
111
112 `mount -t hugetlbfs -o pagesize=1G none /dev/hugepages`
113
114 Ref to http://www.dpdk.org/doc/quick-start for verifying DPDK setup.
115
116 4. Follow the instructions in [INSTALL.md] to install only the
117 userspace daemons and utilities (via 'make install').
118 1. First time only db creation (or clearing):
119
120 ```
121 mkdir -p /usr/local/etc/openvswitch
122 mkdir -p /usr/local/var/run/openvswitch
123 rm /usr/local/etc/openvswitch/conf.db
124 ovsdb-tool create /usr/local/etc/openvswitch/conf.db \
125 /usr/local/share/openvswitch/vswitch.ovsschema
126 ```
127
128 2. Start ovsdb-server
129
130 ```
131 ovsdb-server --remote=punix:/usr/local/var/run/openvswitch/db.sock \
132 --remote=db:Open_vSwitch,Open_vSwitch,manager_options \
133 --private-key=db:Open_vSwitch,SSL,private_key \
134 --certificate=Open_vSwitch,SSL,certificate \
135 --bootstrap-ca-cert=db:Open_vSwitch,SSL,ca_cert --pidfile --detach
136 ```
137
138 3. First time after db creation, initialize:
139
140 ```
141 ovs-vsctl --no-wait init
142 ```
143
144 5. Start vswitchd:
145
146 DPDK configuration arguments can be passed to vswitchd via `--dpdk`
147 argument. This needs to be first argument passed to vswitchd process.
148 dpdk arg -c is ignored by ovs-dpdk, but it is a required parameter
149 for dpdk initialization.
150
151 ```
152 export DB_SOCK=/usr/local/var/run/openvswitch/db.sock
153 ovs-vswitchd --dpdk -c 0x1 -n 4 -- unix:$DB_SOCK --pidfile --detach
154 ```
155
156 If allocated more than one GB hugepage (as for IVSHMEM), set amount and
157 use NUMA node 0 memory:
158
159 ```
160 ovs-vswitchd --dpdk -c 0x1 -n 4 --socket-mem 1024,0 \
161 -- unix:$DB_SOCK --pidfile --detach
162 ```
163
164 6. Add bridge & ports
165
166 To use ovs-vswitchd with DPDK, create a bridge with datapath_type
167 "netdev" in the configuration database. For example:
168
169 `ovs-vsctl add-br br0 -- set bridge br0 datapath_type=netdev`
170
171 Now you can add dpdk devices. OVS expects DPDK device names to start with
172 "dpdk" and end with a portid. vswitchd should print (in the log file) the
173 number of dpdk devices found.
174
175 ```
176 ovs-vsctl add-port br0 dpdk0 -- set Interface dpdk0 type=dpdk
177 ovs-vsctl add-port br0 dpdk1 -- set Interface dpdk1 type=dpdk
178 ```
179
180 Once first DPDK port is added to vswitchd, it creates a Polling thread and
181 polls dpdk device in continuous loop. Therefore CPU utilization
182 for that thread is always 100%.
183
184 Note: creating bonds of DPDK interfaces is slightly different to creating
185 bonds of system interfaces. For DPDK, the interface type must be explicitly
186 set, for example:
187
188 ```
189 ovs-vsctl add-bond br0 dpdkbond dpdk0 dpdk1 -- set Interface dpdk0 type=dpdk -- set Interface dpdk1 type=dpdk
190 ```
191
192 7. Add test flows
193
194 Test flow script across NICs (assuming ovs in /usr/src/ovs):
195 Execute script:
196
197 ```
198 #! /bin/sh
199 # Move to command directory
200 cd /usr/src/ovs/utilities/
201
202 # Clear current flows
203 ./ovs-ofctl del-flows br0
204
205 # Add flows between port 1 (dpdk0) to port 2 (dpdk1)
206 ./ovs-ofctl add-flow br0 in_port=1,action=output:2
207 ./ovs-ofctl add-flow br0 in_port=2,action=output:1
208 ```
209
210 Performance Tuning:
211 -------------------
212
213 1. PMD affinitization
214
215 A poll mode driver (pmd) thread handles the I/O of all DPDK
216 interfaces assigned to it. A pmd thread will busy loop through
217 the assigned port/rxq's polling for packets, switch the packets
218 and send to a tx port if required. Typically, it is found that
219 a pmd thread is CPU bound, meaning that the greater the CPU
220 occupancy the pmd thread can get, the better the performance. To
221 that end, it is good practice to ensure that a pmd thread has as
222 many cycles on a core available to it as possible. This can be
223 achieved by affinitizing the pmd thread with a core that has no
224 other workload. See section 7 below for a description of how to
225 isolate cores for this purpose also.
226
227 The following command can be used to specify the affinity of the
228 pmd thread(s).
229
230 `ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=<hex string>`
231
232 By setting a bit in the mask, a pmd thread is created and pinned
233 to the corresponding CPU core. e.g. to run a pmd thread on core 1
234
235 `ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=2`
236
237 For more information, please refer to the Open_vSwitch TABLE section in
238
239 `man ovs-vswitchd.conf.db`
240
241 Note, that a pmd thread on a NUMA node is only created if there is
242 at least one DPDK interface from that NUMA node added to OVS.
243
244 2. Multiple poll mode driver threads
245
246 With pmd multi-threading support, OVS creates one pmd thread
247 for each NUMA node by default. However, it can be seen that in cases
248 where there are multiple ports/rxq's producing traffic, performance
249 can be improved by creating multiple pmd threads running on separate
250 cores. These pmd threads can then share the workload by each being
251 responsible for different ports/rxq's. Assignment of ports/rxq's to
252 pmd threads is done automatically.
253
254 The following command can be used to specify the affinity of the
255 pmd threads.
256
257 `ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=<hex string>`
258
259 A set bit in the mask means a pmd thread is created and pinned
260 to the corresponding CPU core. e.g. to run pmd threads on core 1 and 2
261
262 `ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=6`
263
264 For more information, please refer to the Open_vSwitch TABLE section in
265
266 `man ovs-vswitchd.conf.db`
267
268 For example, when using dpdk and dpdkvhostuser ports in a bi-directional
269 VM loopback as shown below, spreading the workload over 2 or 4 pmd
270 threads shows significant improvements as there will be more total CPU
271 occupancy available.
272
273 NIC port0 <-> OVS <-> VM <-> OVS <-> NIC port 1
274
275 The OVS log can be checked to confirm that the port/rxq assignment to
276 pmd threads is as required. This can also be checked with the following
277 commands:
278
279 ```
280 top -H
281 taskset -p <pid_of_pmd>
282 ```
283
284 To understand where most of the pmd thread time is spent and whether the
285 caches are being utilized, these commands can be used:
286
287 ```
288 # Clear previous stats
289 ovs-appctl dpif-netdev/pmd-stats-clear
290
291 # Check current stats
292 ovs-appctl dpif-netdev/pmd-stats-show
293 ```
294
295 3. DPDK port Rx Queues
296
297 `ovs-vsctl set Open_vSwitch . other_config:n-dpdk-rxqs=<integer>`
298
299 The command above sets the number of rx queues for each DPDK interface.
300 The rx queues are assigned to pmd threads on the same NUMA node in a
301 round-robin fashion. For more information, please refer to the
302 Open_vSwitch TABLE section in
303
304 `man ovs-vswitchd.conf.db`
305
306 4. Exact Match Cache
307
308 Each pmd thread contains one EMC. After initial flow setup in the
309 datapath, the EMC contains a single table and provides the lowest level
310 (fastest) switching for DPDK ports. If there is a miss in the EMC then
311 the next level where switching will occur is the datapath classifier.
312 Missing in the EMC and looking up in the datapath classifier incurs a
313 significant performance penalty. If lookup misses occur in the EMC
314 because it is too small to handle the number of flows, its size can
315 be increased. The EMC size can be modified by editing the define
316 EM_FLOW_HASH_SHIFT in lib/dpif-netdev.c.
317
318 As mentioned above an EMC is per pmd thread. So an alternative way of
319 increasing the aggregate amount of possible flow entries in EMC and
320 avoiding datapath classifier lookups is to have multiple pmd threads
321 running. This can be done as described in section 2.
322
323 5. Compiler options
324
325 The default compiler optimization level is '-O2'. Changing this to
326 more aggressive compiler optimizations such as '-O3' or
327 '-Ofast -march=native' with gcc can produce performance gains.
328
329 6. Simultaneous Multithreading (SMT)
330
331 With SMT enabled, one physical core appears as two logical cores
332 which can improve performance.
333
334 SMT can be utilized to add additional pmd threads without consuming
335 additional physical cores. Additional pmd threads may be added in the
336 same manner as described in section 2. If trying to minimize the use
337 of physical cores for pmd threads, care must be taken to set the
338 correct bits in the pmd-cpu-mask to ensure that the pmd threads are
339 pinned to SMT siblings.
340
341 For example, when using 2x 10 core processors in a dual socket system
342 with HT enabled, /proc/cpuinfo will report 40 logical cores. To use
343 two logical cores which share the same physical core for pmd threads,
344 the following command can be used to identify a pair of logical cores.
345
346 `cat /sys/devices/system/cpu/cpuN/topology/thread_siblings_list`
347
348 where N is the logical core number. In this example, it would show that
349 cores 1 and 21 share the same physical core. The pmd-cpu-mask to enable
350 two pmd threads running on these two logical cores (one physical core)
351 is.
352
353 `ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=100002`
354
355 Note that SMT is enabled by the Hyper-Threading section in the
356 BIOS, and as such will apply to the whole system. So the impact of
357 enabling/disabling it for the whole system should be considered
358 e.g. If workloads on the system can scale across multiple cores,
359 SMT may very beneficial. However, if they do not and perform best
360 on a single physical core, SMT may not be beneficial.
361
362 7. The isolcpus kernel boot parameter
363
364 isolcpus can be used on the kernel bootline to isolate cores from the
365 kernel scheduler and hence dedicate them to OVS or other packet
366 forwarding related workloads. For example a Linux kernel boot-line
367 could be:
368
369 'GRUB_CMDLINE_LINUX_DEFAULT="quiet hugepagesz=1G hugepages=4 default_hugepagesz=1G 'intel_iommu=off' isolcpus=1-19"'
370
371 8. NUMA/Cluster On Die
372
373 Ideally inter NUMA datapaths should be avoided where possible as packets
374 will go across QPI and there may be a slight performance penalty when
375 compared with intra NUMA datapaths. On Intel Xeon Processor E5 v3,
376 Cluster On Die is introduced on models that have 10 cores or more.
377 This makes it possible to logically split a socket into two NUMA regions
378 and again it is preferred where possible to keep critical datapaths
379 within the one cluster.
380
381 It is good practice to ensure that threads that are in the datapath are
382 pinned to cores in the same NUMA area. e.g. pmd threads and QEMU vCPUs
383 responsible for forwarding.
384
385 9. Rx Mergeable buffers
386
387 Rx Mergeable buffers is a virtio feature that allows chaining of multiple
388 virtio descriptors to handle large packet sizes. As such, large packets
389 are handled by reserving and chaining multiple free descriptors
390 together. Mergeable buffer support is negotiated between the virtio
391 driver and virtio device and is supported by the DPDK vhost library.
392 This behavior is typically supported and enabled by default, however
393 in the case where the user knows that rx mergeable buffers are not needed
394 i.e. jumbo frames are not needed, it can be forced off by adding
395 rx_mrgbuf=off to the QEMU command line options. By not reserving multiple
396 chains of descriptors it will make more individual virtio descriptors
397 available for rx to the guest using dpdkvhost ports and this can improve
398 performance.
399
400 10. Packet processing in the guest
401
402 It is good practice whether simply forwarding packets from one
403 interface to another or more complex packet processing in the guest,
404 to ensure that the thread performing this work has as much CPU
405 occupancy as possible. For example when the DPDK sample application
406 `testpmd` is used to forward packets in the guest, multiple QEMU vCPU
407 threads can be created. Taskset can then be used to affinitize the
408 vCPU thread responsible for forwarding to a dedicated core not used
409 for other general processing on the host system.
410
411 11. DPDK virtio pmd in the guest
412
413 dpdkvhostcuse or dpdkvhostuser ports can be used to accelerate the path
414 to the guest using the DPDK vhost library. This library is compatible with
415 virtio-net drivers in the guest but significantly better performance can
416 be observed when using the DPDK virtio pmd driver in the guest. The DPDK
417 `testpmd` application can be used in the guest as an example application
418 that forwards packet from one DPDK vhost port to another. An example of
419 running `testpmd` in the guest can be seen here.
420
421 `./testpmd -c 0x3 -n 4 --socket-mem 512 -- --burst=64 -i --txqflags=0xf00 --disable-hw-vlan --forward-mode=io --auto-start`
422
423 See below information on dpdkvhostcuse and dpdkvhostuser ports.
424 See [DPDK Docs] for more information on `testpmd`.
425
426
427
428 DPDK Rings :
429 ------------
430
431 Following the steps above to create a bridge, you can now add dpdk rings
432 as a port to the vswitch. OVS will expect the DPDK ring device name to
433 start with dpdkr and end with a portid.
434
435 `ovs-vsctl add-port br0 dpdkr0 -- set Interface dpdkr0 type=dpdkr`
436
437 DPDK rings client test application
438
439 Included in the test directory is a sample DPDK application for testing
440 the rings. This is from the base dpdk directory and modified to work
441 with the ring naming used within ovs.
442
443 location tests/ovs_client
444
445 To run the client :
446
447 ```
448 cd /usr/src/ovs/tests/
449 ovsclient -c 1 -n 4 --proc-type=secondary -- -n "port id you gave dpdkr"
450 ```
451
452 In the case of the dpdkr example above the "port id you gave dpdkr" is 0.
453
454 It is essential to have --proc-type=secondary
455
456 The application simply receives an mbuf on the receive queue of the
457 ethernet ring and then places that same mbuf on the transmit ring of
458 the ethernet ring. It is a trivial loopback application.
459
460 DPDK rings in VM (IVSHMEM shared memory communications)
461 -------------------------------------------------------
462
463 In addition to executing the client in the host, you can execute it within
464 a guest VM. To do so you will need a patched qemu. You can download the
465 patch and getting started guide at :
466
467 https://01.org/packet-processing/downloads
468
469 A general rule of thumb for better performance is that the client
470 application should not be assigned the same dpdk core mask "-c" as
471 the vswitchd.
472
473 DPDK vhost:
474 -----------
475
476 DPDK 2.1 supports two types of vhost:
477
478 1. vhost-user
479 2. vhost-cuse
480
481 Whatever type of vhost is enabled in the DPDK build specified, is the type
482 that will be enabled in OVS. By default, vhost-user is enabled in DPDK.
483 Therefore, unless vhost-cuse has been enabled in DPDK, vhost-user ports
484 will be enabled in OVS.
485 Please note that support for vhost-cuse is intended to be deprecated in OVS
486 in a future release.
487
488 DPDK vhost-user:
489 ----------------
490
491 The following sections describe the use of vhost-user 'dpdkvhostuser' ports
492 with OVS.
493
494 DPDK vhost-user Prerequisites:
495 -------------------------
496
497 1. DPDK 2.1 with vhost support enabled as documented in the "Building and
498 Installing section"
499
500 2. QEMU version v2.1.0+
501
502 QEMU v2.1.0 will suffice, but it is recommended to use v2.2.0 if providing
503 your VM with memory greater than 1GB due to potential issues with memory
504 mapping larger areas.
505
506 Adding DPDK vhost-user ports to the Switch:
507 --------------------------------------
508
509 Following the steps above to create a bridge, you can now add DPDK vhost-user
510 as a port to the vswitch. Unlike DPDK ring ports, DPDK vhost-user ports can
511 have arbitrary names.
512
513 - For vhost-user, the name of the port type is `dpdkvhostuser`
514
515 ```
516 ovs-vsctl add-port br0 vhost-user-1 -- set Interface vhost-user-1
517 type=dpdkvhostuser
518 ```
519
520 This action creates a socket located at
521 `/usr/local/var/run/openvswitch/vhost-user-1`, which you must provide
522 to your VM on the QEMU command line. More instructions on this can be
523 found in the next section "DPDK vhost-user VM configuration"
524 Note: If you wish for the vhost-user sockets to be created in a
525 directory other than `/usr/local/var/run/openvswitch`, you may specify
526 another location on the ovs-vswitchd command line like so:
527
528 `./vswitchd/ovs-vswitchd --dpdk -vhost_sock_dir /my-dir -c 0x1 ...`
529
530 DPDK vhost-user VM configuration:
531 ---------------------------------
532 Follow the steps below to attach vhost-user port(s) to a VM.
533
534 1. Configure sockets.
535 Pass the following parameters to QEMU to attach a vhost-user device:
536
537 ```
538 -chardev socket,id=char1,path=/usr/local/var/run/openvswitch/vhost-user-1
539 -netdev type=vhost-user,id=mynet1,chardev=char1,vhostforce
540 -device virtio-net-pci,mac=00:00:00:00:00:01,netdev=mynet1
541 ```
542
543 ...where vhost-user-1 is the name of the vhost-user port added
544 to the switch.
545 Repeat the above parameters for multiple devices, changing the
546 chardev path and id as necessary. Note that a separate and different
547 chardev path needs to be specified for each vhost-user device. For
548 example you have a second vhost-user port named 'vhost-user-2', you
549 append your QEMU command line with an additional set of parameters:
550
551 ```
552 -chardev socket,id=char2,path=/usr/local/var/run/openvswitch/vhost-user-2
553 -netdev type=vhost-user,id=mynet2,chardev=char2,vhostforce
554 -device virtio-net-pci,mac=00:00:00:00:00:02,netdev=mynet2
555 ```
556
557 2. Configure huge pages.
558 QEMU must allocate the VM's memory on hugetlbfs. vhost-user ports access
559 a virtio-net device's virtual rings and packet buffers mapping the VM's
560 physical memory on hugetlbfs. To enable vhost-user ports to map the VM's
561 memory into their process address space, pass the following paramters
562 to QEMU:
563
564 ```
565 -object memory-backend-file,id=mem,size=4096M,mem-path=/dev/hugepages,
566 share=on
567 -numa node,memdev=mem -mem-prealloc
568 ```
569
570 DPDK vhost-cuse:
571 ----------------
572
573 The following sections describe the use of vhost-cuse 'dpdkvhostcuse' ports
574 with OVS.
575
576 DPDK vhost-cuse Prerequisites:
577 -------------------------
578
579 1. DPDK 2.1 with vhost support enabled as documented in the "Building and
580 Installing section"
581 As an additional step, you must enable vhost-cuse in DPDK by setting the
582 following additional flag in `config/common_linuxapp`:
583
584 `CONFIG_RTE_LIBRTE_VHOST_USER=n`
585
586 Following this, rebuild DPDK as per the instructions in the "Building and
587 Installing" section. Finally, rebuild OVS as per step 3 in the "Building
588 and Installing" section - OVS will detect that DPDK has vhost-cuse libraries
589 compiled and in turn will enable support for it in the switch and disable
590 vhost-user support.
591
592 2. Insert the Cuse module:
593
594 `modprobe cuse`
595
596 3. Build and insert the `eventfd_link` module:
597
598 ```
599 cd $DPDK_DIR/lib/librte_vhost/eventfd_link/
600 make
601 insmod $DPDK_DIR/lib/librte_vhost/eventfd_link.ko
602 ```
603
604 4. QEMU version v2.1.0+
605
606 vhost-cuse will work with QEMU v2.1.0 and above, however it is recommended to
607 use v2.2.0 if providing your VM with memory greater than 1GB due to potential
608 issues with memory mapping larger areas.
609 Note: QEMU v1.6.2 will also work, with slightly different command line parameters,
610 which are specified later in this document.
611
612 Adding DPDK vhost-cuse ports to the Switch:
613 --------------------------------------
614
615 Following the steps above to create a bridge, you can now add DPDK vhost-cuse
616 as a port to the vswitch. Unlike DPDK ring ports, DPDK vhost-cuse ports can have
617 arbitrary names.
618
619 - For vhost-cuse, the name of the port type is `dpdkvhostcuse`
620
621 ```
622 ovs-vsctl add-port br0 vhost-cuse-1 -- set Interface vhost-cuse-1
623 type=dpdkvhostcuse
624 ```
625
626 When attaching vhost-cuse ports to QEMU, the name provided during the
627 add-port operation must match the ifname parameter on the QEMU command
628 line. More instructions on this can be found in the next section.
629
630 DPDK vhost-cuse VM configuration:
631 ---------------------------------
632
633 vhost-cuse ports use a Linux* character device to communicate with QEMU.
634 By default it is set to `/dev/vhost-net`. It is possible to reuse this
635 standard device for DPDK vhost, which makes setup a little simpler but it
636 is better practice to specify an alternative character device in order to
637 avoid any conflicts if kernel vhost is to be used in parallel.
638
639 1. This step is only needed if using an alternative character device.
640
641 The new character device filename must be specified on the vswitchd
642 commandline:
643
644 `./vswitchd/ovs-vswitchd --dpdk --cuse_dev_name my-vhost-net -c 0x1 ...`
645
646 Note that the `--cuse_dev_name` argument and associated string must be the first
647 arguments after `--dpdk` and come before the EAL arguments. In the example
648 above, the character device to be used will be `/dev/my-vhost-net`.
649
650 2. This step is only needed if reusing the standard character device. It will
651 conflict with the kernel vhost character device so the user must first
652 remove it.
653
654 `rm -rf /dev/vhost-net`
655
656 3a. Configure virtio-net adaptors:
657 The following parameters must be passed to the QEMU binary:
658
659 ```
660 -netdev tap,id=<id>,script=no,downscript=no,ifname=<name>,vhost=on
661 -device virtio-net-pci,netdev=net1,mac=<mac>
662 ```
663
664 Repeat the above parameters for multiple devices.
665
666 The DPDK vhost library will negiotiate its own features, so they
667 need not be passed in as command line params. Note that as offloads are
668 disabled this is the equivalent of setting:
669
670 `csum=off,gso=off,guest_tso4=off,guest_tso6=off,guest_ecn=off`
671
672 3b. If using an alternative character device. It must be also explicitly
673 passed to QEMU using the `vhostfd` argument:
674
675 ```
676 -netdev tap,id=<id>,script=no,downscript=no,ifname=<name>,vhost=on,
677 vhostfd=<open_fd>
678 -device virtio-net-pci,netdev=net1,mac=<mac>
679 ```
680
681 The open file descriptor must be passed to QEMU running as a child
682 process. This could be done with a simple python script.
683
684 ```
685 #!/usr/bin/python
686 fd = os.open("/dev/usvhost", os.O_RDWR)
687 subprocess.call("qemu-system-x86_64 .... -netdev tap,id=vhostnet0,\
688 vhost=on,vhostfd=" + fd +"...", shell=True)
689
690 Alternatively the `qemu-wrap.py` script can be used to automate the
691 requirements specified above and can be used in conjunction with libvirt if
692 desired. See the "DPDK vhost VM configuration with QEMU wrapper" section
693 below.
694
695 4. Configure huge pages:
696 QEMU must allocate the VM's memory on hugetlbfs. Vhost ports access a
697 virtio-net device's virtual rings and packet buffers mapping the VM's
698 physical memory on hugetlbfs. To enable vhost-ports to map the VM's
699 memory into their process address space, pass the following parameters
700 to QEMU:
701
702 `-object memory-backend-file,id=mem,size=4096M,mem-path=/dev/hugepages,
703 share=on -numa node,memdev=mem -mem-prealloc`
704
705 Note: For use with an earlier QEMU version such as v1.6.2, use the
706 following to configure hugepages instead:
707
708 `-mem-path /dev/hugepages -mem-prealloc`
709
710 DPDK vhost-cuse VM configuration with QEMU wrapper:
711 ---------------------------------------------------
712 The QEMU wrapper script automatically detects and calls QEMU with the
713 necessary parameters. It performs the following actions:
714
715 * Automatically detects the location of the hugetlbfs and inserts this
716 into the command line parameters.
717 * Automatically open file descriptors for each virtio-net device and
718 inserts this into the command line parameters.
719 * Calls QEMU passing both the command line parameters passed to the
720 script itself and those it has auto-detected.
721
722 Before use, you **must** edit the configuration parameters section of the
723 script to point to the correct emulator location and set additional
724 settings. Of these settings, `emul_path` and `us_vhost_path` **must** be
725 set. All other settings are optional.
726
727 To use directly from the command line simply pass the wrapper some of the
728 QEMU parameters: it will configure the rest. For example:
729
730 ```
731 qemu-wrap.py -cpu host -boot c -hda <disk image> -m 4096 -smp 4
732 --enable-kvm -nographic -vnc none -net none -netdev tap,id=net1,
733 script=no,downscript=no,ifname=if1,vhost=on -device virtio-net-pci,
734 netdev=net1,mac=00:00:00:00:00:01
735 ```
736
737 DPDK vhost-cuse VM configuration with libvirt:
738 ----------------------------------------------
739
740 If you are using libvirt, you must enable libvirt to access the character
741 device by adding it to controllers cgroup for libvirtd using the following
742 steps.
743
744 1. In `/etc/libvirt/qemu.conf` add/edit the following lines:
745
746 ```
747 1) clear_emulator_capabilities = 0
748 2) user = "root"
749 3) group = "root"
750 4) cgroup_device_acl = [
751 "/dev/null", "/dev/full", "/dev/zero",
752 "/dev/random", "/dev/urandom",
753 "/dev/ptmx", "/dev/kvm", "/dev/kqemu",
754 "/dev/rtc", "/dev/hpet", "/dev/net/tun",
755 "/dev/<my-vhost-device>",
756 "/dev/hugepages"]
757 ```
758
759 <my-vhost-device> refers to "vhost-net" if using the `/dev/vhost-net`
760 device. If you have specificed a different name on the ovs-vswitchd
761 commandline using the "--cuse_dev_name" parameter, please specify that
762 filename instead.
763
764 2. Disable SELinux or set to permissive mode
765
766 3. Restart the libvirtd process
767 For example, on Fedora:
768
769 `systemctl restart libvirtd.service`
770
771 After successfully editing the configuration, you may launch your
772 vhost-enabled VM. The XML describing the VM can be configured like so
773 within the <qemu:commandline> section:
774
775 1. Set up shared hugepages:
776
777 ```
778 <qemu:arg value='-object'/>
779 <qemu:arg value='memory-backend-file,id=mem,size=4096M,mem-path=/dev/hugepages,share=on'/>
780 <qemu:arg value='-numa'/>
781 <qemu:arg value='node,memdev=mem'/>
782 <qemu:arg value='-mem-prealloc'/>
783 ```
784
785 2. Set up your tap devices:
786
787 ```
788 <qemu:arg value='-netdev'/>
789 <qemu:arg value='type=tap,id=net1,script=no,downscript=no,ifname=vhost0,vhost=on'/>
790 <qemu:arg value='-device'/>
791 <qemu:arg value='virtio-net-pci,netdev=net1,mac=00:00:00:00:00:01'/>
792 ```
793
794 Repeat for as many devices as are desired, modifying the id, ifname
795 and mac as necessary.
796
797 Again, if you are using an alternative character device (other than
798 `/dev/vhost-net`), please specify the file descriptor like so:
799
800 `<qemu:arg value='type=tap,id=net3,script=no,downscript=no,ifname=vhost0,vhost=on,vhostfd=<open_fd>'/>`
801
802 Where <open_fd> refers to the open file descriptor of the character device.
803 Instructions of how to retrieve the file descriptor can be found in the
804 "DPDK vhost VM configuration" section.
805 Alternatively, the process is automated with the qemu-wrap.py script,
806 detailed in the next section.
807
808 Now you may launch your VM using virt-manager, or like so:
809
810 `virsh create my_vhost_vm.xml`
811
812 DPDK vhost-cuse VM configuration with libvirt and QEMU wrapper:
813 ----------------------------------------------------------
814
815 To use the qemu-wrapper script in conjuntion with libvirt, follow the
816 steps in the previous section before proceeding with the following steps:
817
818 1. Place `qemu-wrap.py` in libvirtd's binary search PATH ($PATH)
819 Ideally in the same directory that the QEMU binary is located.
820
821 2. Ensure that the script has the same owner/group and file permissions
822 as the QEMU binary.
823
824 3. Update the VM xml file using "virsh edit VM.xml"
825
826 1. Set the VM to use the launch script.
827 Set the emulator path contained in the `<emulator><emulator/>` tags.
828 For example, replace:
829
830 `<emulator>/usr/bin/qemu-kvm<emulator/>`
831
832 with:
833
834 `<emulator>/usr/bin/qemu-wrap.py<emulator/>`
835
836 4. Edit the Configuration Parameters section of the script to point to
837 the correct emulator location and set any additional options. If you are
838 using a alternative character device name, please set "us_vhost_path" to the
839 location of that device. The script will automatically detect and insert
840 the correct "vhostfd" value in the QEMU command line arguments.
841
842 5. Use virt-manager to launch the VM
843
844 Running ovs-vswitchd with DPDK backend inside a VM
845 --------------------------------------------------
846
847 Please note that additional configuration is required if you want to run
848 ovs-vswitchd with DPDK backend inside a QEMU virtual machine. Ovs-vswitchd
849 creates separate DPDK TX queues for each CPU core available. This operation
850 fails inside QEMU virtual machine because, by default, VirtIO NIC provided
851 to the guest is configured to support only single TX queue and single RX
852 queue. To change this behavior, you need to turn on 'mq' (multiqueue)
853 property of all virtio-net-pci devices emulated by QEMU and used by DPDK.
854 You may do it manually (by changing QEMU command line) or, if you use Libvirt,
855 by adding the following string:
856
857 `<driver name='vhost' queues='N'/>`
858
859 to <interface> sections of all network devices used by DPDK. Parameter 'N'
860 determines how many queues can be used by the guest.
861
862 Restrictions:
863 -------------
864
865 - Work with 1500 MTU, needs few changes in DPDK lib to fix this issue.
866 - Currently DPDK port does not make use any offload functionality.
867 - DPDK-vHost support works with 1G huge pages.
868
869 ivshmem:
870 - If you run Open vSwitch with smaller page sizes (e.g. 2MB), you may be
871 unable to share any rings or mempools with a virtual machine.
872 This is because the current implementation of ivshmem works by sharing
873 a single 1GB huge page from the host operating system to any guest
874 operating system through the Qemu ivshmem device. When using smaller
875 page sizes, multiple pages may be required to hold the ring descriptors
876 and buffer pools. The Qemu ivshmem device does not allow you to share
877 multiple file descriptors to the guest operating system. However, if you
878 want to share dpdkr rings with other processes on the host, you can do
879 this with smaller page sizes.
880
881 Platform and Network Interface:
882 - Currently it is not possible to use an Intel XL710 Network Interface as a
883 DPDK port type on a platform with more than 64 logical cores. This is
884 related to how DPDK reports the number of TX queues that may be used by
885 a DPDK application with an XL710. The maximum number of TX queues supported
886 by a DPDK application for an XL710 is 64. If a user attempts to add an
887 XL710 interface as a DPDK port type to a system as described above the
888 port addition will fail as OVS will attempt to initialize a TX queue greater
889 than 64. This issue is expected to be resolved in a future DPDK release.
890 As a workaround a user can disable hyper-threading to reduce the overall
891 core count of the system to be less than or equal to 64 when using an XL710
892 interface with DPDK.
893
894 Bug Reporting:
895 --------------
896
897 Please report problems to bugs@openvswitch.org.
898
899 [INSTALL.userspace.md]:INSTALL.userspace.md
900 [INSTALL.md]:INSTALL.md
901 [DPDK Linux GSG]: http://www.dpdk.org/doc/guides/linux_gsg/build_dpdk.html#binding-and-unbinding-network-ports-to-from-the-igb-uioor-vfio-modules
902 [DPDK Docs]: http://dpdk.org/doc