]> git.proxmox.com Git - mirror_ubuntu-bionic-kernel.git/blob - drivers/scsi/Kconfig
Merge tag 'armsoc-dt64' of git://git.kernel.org/pub/scm/linux/kernel/git/arm/arm-soc
[mirror_ubuntu-bionic-kernel.git] / drivers / scsi / Kconfig
1 menu "SCSI device support"
2
3 config SCSI_MOD
4 tristate
5 default y if SCSI=n || SCSI=y
6 default m if SCSI=m
7
8 config RAID_ATTRS
9 tristate "RAID Transport Class"
10 default n
11 depends on BLOCK
12 depends on SCSI_MOD
13 ---help---
14 Provides RAID
15
16 config SCSI
17 tristate "SCSI device support"
18 depends on BLOCK
19 select SCSI_DMA if HAS_DMA
20 ---help---
21 If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
22 any other SCSI device under Linux, say Y and make sure that you know
23 the name of your SCSI host adapter (the card inside your computer
24 that "speaks" the SCSI protocol, also called SCSI controller),
25 because you will be asked for it.
26
27 You also need to say Y here if you have a device which speaks
28 the SCSI protocol. Examples of this include the parallel port
29 version of the IOMEGA ZIP drive, USB storage devices, Fibre
30 Channel, and FireWire storage.
31
32 To compile this driver as a module, choose M here and read
33 <file:Documentation/scsi/scsi.txt>.
34 The module will be called scsi_mod.
35
36 However, do not compile this as a module if your root file system
37 (the one containing the directory /) is located on a SCSI device.
38
39 config SCSI_DMA
40 bool
41 default n
42
43 config SCSI_NETLINK
44 bool
45 default n
46 depends on NET
47
48 config SCSI_MQ_DEFAULT
49 bool "SCSI: use blk-mq I/O path by default"
50 depends on SCSI
51 ---help---
52 This option enables the new blk-mq based I/O path for SCSI
53 devices by default. With the option the scsi_mod.use_blk_mq
54 module/boot option defaults to Y, without it to N, but it can
55 still be overridden either way.
56
57 If unsure say N.
58
59 config SCSI_PROC_FS
60 bool "legacy /proc/scsi/ support"
61 depends on SCSI && PROC_FS
62 default y
63 ---help---
64 This option enables support for the various files in
65 /proc/scsi. In Linux 2.6 this has been superseded by
66 files in sysfs but many legacy applications rely on this.
67
68 If unsure say Y.
69
70 comment "SCSI support type (disk, tape, CD-ROM)"
71 depends on SCSI
72
73 config BLK_DEV_SD
74 tristate "SCSI disk support"
75 depends on SCSI
76 ---help---
77 If you want to use SCSI hard disks, Fibre Channel disks,
78 Serial ATA (SATA) or Parallel ATA (PATA) hard disks,
79 USB storage or the SCSI or parallel port version of
80 the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
81 the Disk-HOWTO and the Multi-Disk-HOWTO, available from
82 <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
83 CD-ROMs.
84
85 To compile this driver as a module, choose M here and read
86 <file:Documentation/scsi/scsi.txt>.
87 The module will be called sd_mod.
88
89 Do not compile this driver as a module if your root file system
90 (the one containing the directory /) is located on a SCSI disk.
91 In this case, do not compile the driver for your SCSI host adapter
92 (below) as a module either.
93
94 config CHR_DEV_ST
95 tristate "SCSI tape support"
96 depends on SCSI
97 ---help---
98 If you want to use a SCSI tape drive under Linux, say Y and read the
99 SCSI-HOWTO, available from
100 <http://www.tldp.org/docs.html#howto>, and
101 <file:Documentation/scsi/st.txt> in the kernel source. This is NOT
102 for SCSI CD-ROMs.
103
104 To compile this driver as a module, choose M here and read
105 <file:Documentation/scsi/scsi.txt>. The module will be called st.
106
107 config CHR_DEV_OSST
108 tristate "SCSI OnStream SC-x0 tape support"
109 depends on SCSI
110 ---help---
111 The OnStream SC-x0 SCSI tape drives cannot be driven by the
112 standard st driver, but instead need this special osst driver and
113 use the /dev/osstX char device nodes (major 206). Via usb-storage,
114 you may be able to drive the USB-x0 and DI-x0 drives as well.
115 Note that there is also a second generation of OnStream
116 tape drives (ADR-x0) that supports the standard SCSI-2 commands for
117 tapes (QIC-157) and can be driven by the standard driver st.
118 For more information, you may have a look at the SCSI-HOWTO
119 <http://www.tldp.org/docs.html#howto> and
120 <file:Documentation/scsi/osst.txt> in the kernel source.
121 More info on the OnStream driver may be found on
122 <http://sourceforge.net/projects/osst/>
123 Please also have a look at the standard st docu, as most of it
124 applies to osst as well.
125
126 To compile this driver as a module, choose M here and read
127 <file:Documentation/scsi/scsi.txt>. The module will be called osst.
128
129 config BLK_DEV_SR
130 tristate "SCSI CDROM support"
131 depends on SCSI
132 ---help---
133 If you want to use a CD or DVD drive attached to your computer
134 by SCSI, FireWire, USB or ATAPI, say Y and read the SCSI-HOWTO
135 and the CDROM-HOWTO at <http://www.tldp.org/docs.html#howto>.
136
137 Make sure to say Y or M to "ISO 9660 CD-ROM file system support".
138
139 To compile this driver as a module, choose M here and read
140 <file:Documentation/scsi/scsi.txt>.
141 The module will be called sr_mod.
142
143 config BLK_DEV_SR_VENDOR
144 bool "Enable vendor-specific extensions (for SCSI CDROM)"
145 depends on BLK_DEV_SR
146 help
147 This enables the usage of vendor specific SCSI commands. This is
148 required to support multisession CDs with old NEC/TOSHIBA cdrom
149 drives (and HP Writers). If you have such a drive and get the first
150 session only, try saying Y here; everybody else says N.
151
152 config CHR_DEV_SG
153 tristate "SCSI generic support"
154 depends on SCSI
155 ---help---
156 If you want to use SCSI scanners, synthesizers or CD-writers or just
157 about anything having "SCSI" in its name other than hard disks,
158 CD-ROMs or tapes, say Y here. These won't be supported by the kernel
159 directly, so you need some additional software which knows how to
160 talk to these devices using the SCSI protocol:
161
162 For scanners, look at SANE (<http://www.sane-project.org/>). For CD
163 writer software look at Cdrtools
164 (<http://cdrecord.berlios.de/private/cdrecord.html>)
165 and for burning a "disk at once": CDRDAO
166 (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
167 quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
168 For other devices, it's possible that you'll have to write the
169 driver software yourself. Please read the file
170 <file:Documentation/scsi/scsi-generic.txt> for more information.
171
172 To compile this driver as a module, choose M here and read
173 <file:Documentation/scsi/scsi.txt>. The module will be called sg.
174
175 If unsure, say N.
176
177 config CHR_DEV_SCH
178 tristate "SCSI media changer support"
179 depends on SCSI
180 ---help---
181 This is a driver for SCSI media changers. Most common devices are
182 tape libraries and MOD/CDROM jukeboxes. *Real* jukeboxes, you
183 don't need this for those tiny 6-slot cdrom changers. Media
184 changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
185 If you have such hardware and want to use it with linux, say Y
186 here. Check <file:Documentation/scsi/scsi-changer.txt> for details.
187
188 If you want to compile this as a module ( = code which can be
189 inserted in and removed from the running kernel whenever you want),
190 say M here and read <file:Documentation/kbuild/modules.txt> and
191 <file:Documentation/scsi/scsi.txt>. The module will be called ch.o.
192 If unsure, say N.
193
194 config SCSI_ENCLOSURE
195 tristate "SCSI Enclosure Support"
196 depends on SCSI && ENCLOSURE_SERVICES
197 depends on m || SCSI_SAS_ATTRS != m
198 help
199 Enclosures are devices sitting on or in SCSI backplanes that
200 manage devices. If you have a disk cage, the chances are that
201 it has an enclosure device. Selecting this option will just allow
202 certain enclosure conditions to be reported and is not required.
203
204 config SCSI_CONSTANTS
205 bool "Verbose SCSI error reporting (kernel size +=75K)"
206 depends on SCSI
207 help
208 The error messages regarding your SCSI hardware will be easier to
209 understand if you say Y here; it will enlarge your kernel by about
210 75 KB. If in doubt, say Y.
211
212 config SCSI_LOGGING
213 bool "SCSI logging facility"
214 depends on SCSI
215 ---help---
216 This turns on a logging facility that can be used to debug a number
217 of SCSI related problems.
218
219 If you say Y here, no logging output will appear by default, but you
220 can enable logging by saying Y to "/proc file system support" and
221 "Sysctl support" below and executing the command
222
223 echo <bitmask> > /proc/sys/dev/scsi/logging_level
224
225 where <bitmask> is a four byte value representing the logging type
226 and logging level for each type of logging selected.
227
228 There are a number of logging types and you can find them in the
229 source at <file:drivers/scsi/scsi_logging.h>. The logging levels
230 are also described in that file and they determine the verbosity of
231 the logging for each logging type.
232
233 If you say N here, it may be harder to track down some types of SCSI
234 problems. If you say Y here your kernel will be somewhat larger, but
235 there should be no noticeable performance impact as long as you have
236 logging turned off.
237
238 config SCSI_SCAN_ASYNC
239 bool "Asynchronous SCSI scanning"
240 depends on SCSI
241 help
242 The SCSI subsystem can probe for devices while the rest of the
243 system continues booting, and even probe devices on different
244 busses in parallel, leading to a significant speed-up.
245
246 You can override this choice by specifying "scsi_mod.scan=sync"
247 or async on the kernel's command line.
248
249 Note that this setting also affects whether resuming from
250 system suspend will be performed asynchronously.
251
252 menu "SCSI Transports"
253 depends on SCSI
254
255 config SCSI_SPI_ATTRS
256 tristate "Parallel SCSI (SPI) Transport Attributes"
257 depends on SCSI
258 help
259 If you wish to export transport-specific information about
260 each attached SCSI device to sysfs, say Y. Otherwise, say N.
261
262 config SCSI_FC_ATTRS
263 tristate "FiberChannel Transport Attributes"
264 depends on SCSI && NET
265 select SCSI_NETLINK
266 help
267 If you wish to export transport-specific information about
268 each attached FiberChannel device to sysfs, say Y.
269 Otherwise, say N.
270
271 config SCSI_ISCSI_ATTRS
272 tristate "iSCSI Transport Attributes"
273 depends on SCSI && NET
274 select BLK_DEV_BSGLIB
275 help
276 If you wish to export transport-specific information about
277 each attached iSCSI device to sysfs, say Y.
278 Otherwise, say N.
279
280 config SCSI_SAS_ATTRS
281 tristate "SAS Transport Attributes"
282 depends on SCSI
283 select BLK_DEV_BSG
284 help
285 If you wish to export transport-specific information about
286 each attached SAS device to sysfs, say Y.
287
288 source "drivers/scsi/libsas/Kconfig"
289
290 config SCSI_SRP_ATTRS
291 tristate "SRP Transport Attributes"
292 depends on SCSI
293 help
294 If you wish to export transport-specific information about
295 each attached SRP device to sysfs, say Y.
296
297 endmenu
298
299 menuconfig SCSI_LOWLEVEL
300 bool "SCSI low-level drivers"
301 depends on SCSI!=n
302 default y
303
304 if SCSI_LOWLEVEL && SCSI
305
306 config ISCSI_TCP
307 tristate "iSCSI Initiator over TCP/IP"
308 depends on SCSI && INET
309 select CRYPTO
310 select CRYPTO_MD5
311 select CRYPTO_CRC32C
312 select SCSI_ISCSI_ATTRS
313 help
314 The iSCSI Driver provides a host with the ability to access storage
315 through an IP network. The driver uses the iSCSI protocol to transport
316 SCSI requests and responses over a TCP/IP network between the host
317 (the "initiator") and "targets". Architecturally, the iSCSI driver
318 combines with the host's TCP/IP stack, network drivers, and Network
319 Interface Card (NIC) to provide the same functions as a SCSI or a
320 Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
321
322 To compile this driver as a module, choose M here: the
323 module will be called iscsi_tcp.
324
325 The userspace component needed to initialize the driver, documentation,
326 and sample configuration files can be found here:
327
328 http://open-iscsi.org
329
330 config ISCSI_BOOT_SYSFS
331 tristate "iSCSI Boot Sysfs Interface"
332 default n
333 help
334 This option enables support for exposing iSCSI boot information
335 via sysfs to userspace. If you wish to export this information,
336 say Y. Otherwise, say N.
337
338 source "drivers/scsi/cxgbi/Kconfig"
339 source "drivers/scsi/bnx2i/Kconfig"
340 source "drivers/scsi/bnx2fc/Kconfig"
341 source "drivers/scsi/be2iscsi/Kconfig"
342 source "drivers/scsi/cxlflash/Kconfig"
343
344 config SGIWD93_SCSI
345 tristate "SGI WD93C93 SCSI Driver"
346 depends on SGI_HAS_WD93 && SCSI
347 help
348 If you have a Western Digital WD93 SCSI controller on
349 an SGI MIPS system, say Y. Otherwise, say N.
350
351 config BLK_DEV_3W_XXXX_RAID
352 tristate "3ware 5/6/7/8xxx ATA-RAID support"
353 depends on PCI && SCSI
354 help
355 3ware is the only hardware ATA-Raid product in Linux to date.
356 This card is 2,4, or 8 channel master mode support only.
357 SCSI support required!!!
358
359 <http://www.3ware.com/>
360
361 Please read the comments at the top of
362 <file:drivers/scsi/3w-xxxx.c>.
363
364 config SCSI_HPSA
365 tristate "HP Smart Array SCSI driver"
366 depends on PCI && SCSI
367 select CHECK_SIGNATURE
368 select SCSI_SAS_ATTRS
369 help
370 This driver supports HP Smart Array Controllers (circa 2009).
371 It is a SCSI alternative to the cciss driver, which is a block
372 driver. Anyone wishing to use HP Smart Array controllers who
373 would prefer the devices be presented to linux as SCSI devices,
374 rather than as generic block devices should say Y here.
375
376 config SCSI_3W_9XXX
377 tristate "3ware 9xxx SATA-RAID support"
378 depends on PCI && SCSI
379 help
380 This driver supports the 9000 series 3ware SATA-RAID cards.
381
382 <http://www.amcc.com>
383
384 Please read the comments at the top of
385 <file:drivers/scsi/3w-9xxx.c>.
386
387 config SCSI_3W_SAS
388 tristate "3ware 97xx SAS/SATA-RAID support"
389 depends on PCI && SCSI
390 help
391 This driver supports the LSI 3ware 9750 6Gb/s SAS/SATA-RAID cards.
392
393 <http://www.lsi.com>
394
395 Please read the comments at the top of
396 <file:drivers/scsi/3w-sas.c>.
397
398 config SCSI_7000FASST
399 tristate "7000FASST SCSI support"
400 depends on ISA && SCSI && ISA_DMA_API
401 select CHECK_SIGNATURE
402 help
403 This driver supports the Western Digital 7000 SCSI host adapter
404 family. Some information is in the source:
405 <file:drivers/scsi/wd7000.c>.
406
407 To compile this driver as a module, choose M here: the
408 module will be called wd7000.
409
410 config SCSI_ACARD
411 tristate "ACARD SCSI support"
412 depends on PCI && SCSI
413 help
414 This driver supports the ACARD SCSI host adapter.
415 Support Chip <ATP870 ATP876 ATP880 ATP885>
416 To compile this driver as a module, choose M here: the
417 module will be called atp870u.
418
419 config SCSI_AHA152X
420 tristate "Adaptec AHA152X/2825 support"
421 depends on ISA && SCSI
422 select SCSI_SPI_ATTRS
423 select CHECK_SIGNATURE
424 ---help---
425 This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
426 SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
427 must be manually specified in this case.
428
429 It is explained in section 3.3 of the SCSI-HOWTO, available from
430 <http://www.tldp.org/docs.html#howto>. You might also want to
431 read the file <file:Documentation/scsi/aha152x.txt>.
432
433 To compile this driver as a module, choose M here: the
434 module will be called aha152x.
435
436 config SCSI_AHA1542
437 tristate "Adaptec AHA1542 support"
438 depends on ISA && SCSI && ISA_DMA_API
439 ---help---
440 This is support for a SCSI host adapter. It is explained in section
441 3.4 of the SCSI-HOWTO, available from
442 <http://www.tldp.org/docs.html#howto>. Note that Trantor was
443 purchased by Adaptec, and some former Trantor products are being
444 sold under the Adaptec name. If it doesn't work out of the box, you
445 may have to change some settings in <file:drivers/scsi/aha1542.h>.
446
447 To compile this driver as a module, choose M here: the
448 module will be called aha1542.
449
450 config SCSI_AHA1740
451 tristate "Adaptec AHA1740 support"
452 depends on EISA && SCSI
453 ---help---
454 This is support for a SCSI host adapter. It is explained in section
455 3.5 of the SCSI-HOWTO, available from
456 <http://www.tldp.org/docs.html#howto>. If it doesn't work out
457 of the box, you may have to change some settings in
458 <file:drivers/scsi/aha1740.h>.
459
460 To compile this driver as a module, choose M here: the
461 module will be called aha1740.
462
463 config SCSI_AACRAID
464 tristate "Adaptec AACRAID support"
465 depends on SCSI && PCI
466 help
467 This driver supports a variety of Dell, HP, Adaptec, IBM and
468 ICP storage products. For a list of supported products, refer
469 to <file:Documentation/scsi/aacraid.txt>.
470
471 To compile this driver as a module, choose M here: the module
472 will be called aacraid.
473
474
475 source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
476 source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
477 source "drivers/scsi/aic94xx/Kconfig"
478 source "drivers/scsi/hisi_sas/Kconfig"
479 source "drivers/scsi/mvsas/Kconfig"
480
481 config SCSI_MVUMI
482 tristate "Marvell UMI driver"
483 depends on SCSI && PCI
484 help
485 Module for Marvell Universal Message Interface(UMI) driver
486
487 To compile this driver as a module, choose M here: the
488 module will be called mvumi.
489
490 config SCSI_DPT_I2O
491 tristate "Adaptec I2O RAID support "
492 depends on SCSI && PCI && VIRT_TO_BUS
493 help
494 This driver supports all of Adaptec's I2O based RAID controllers as
495 well as the DPT SmartRaid V cards. This is an Adaptec maintained
496 driver by Deanna Bonds. See <file:Documentation/scsi/dpti.txt>.
497
498 To compile this driver as a module, choose M here: the
499 module will be called dpt_i2o.
500
501 config SCSI_ADVANSYS
502 tristate "AdvanSys SCSI support"
503 depends on SCSI
504 depends on ISA || EISA || PCI
505 depends on ISA_DMA_API || !ISA
506 help
507 This is a driver for all SCSI host adapters manufactured by
508 AdvanSys. It is documented in the kernel source in
509 <file:drivers/scsi/advansys.c>.
510
511 To compile this driver as a module, choose M here: the
512 module will be called advansys.
513
514 config SCSI_IN2000
515 tristate "Always IN2000 SCSI support"
516 depends on ISA && SCSI
517 help
518 This is support for an ISA bus SCSI host adapter. You'll find more
519 information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
520 out of the box, you may have to change the jumpers for IRQ or
521 address selection.
522
523 To compile this driver as a module, choose M here: the
524 module will be called in2000.
525
526 config SCSI_ARCMSR
527 tristate "ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter"
528 depends on PCI && SCSI
529 help
530 This driver supports all of ARECA's SATA/SAS RAID controller cards.
531 This is an ARECA-maintained driver by Erich Chen.
532 If you have any problems, please mail to: <erich@areca.com.tw>.
533 Areca supports Linux RAID config tools.
534 Please link <http://www.areca.com.tw>
535
536 To compile this driver as a module, choose M here: the
537 module will be called arcmsr (modprobe arcmsr).
538
539 source "drivers/scsi/esas2r/Kconfig"
540 source "drivers/scsi/megaraid/Kconfig.megaraid"
541 source "drivers/scsi/mpt3sas/Kconfig"
542 source "drivers/scsi/ufs/Kconfig"
543
544 config SCSI_HPTIOP
545 tristate "HighPoint RocketRAID 3xxx/4xxx Controller support"
546 depends on SCSI && PCI
547 help
548 This option enables support for HighPoint RocketRAID 3xxx/4xxx
549 controllers.
550
551 To compile this driver as a module, choose M here; the module
552 will be called hptiop. If unsure, say N.
553
554 config SCSI_BUSLOGIC
555 tristate "BusLogic SCSI support"
556 depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API && VIRT_TO_BUS
557 ---help---
558 This is support for BusLogic MultiMaster and FlashPoint SCSI Host
559 Adapters. Consult the SCSI-HOWTO, available from
560 <http://www.tldp.org/docs.html#howto>, and the files
561 <file:Documentation/scsi/BusLogic.txt> and
562 <file:Documentation/scsi/FlashPoint.txt> for more information.
563 Note that support for FlashPoint is only available for 32-bit
564 x86 configurations.
565
566 To compile this driver as a module, choose M here: the
567 module will be called BusLogic.
568
569 config SCSI_FLASHPOINT
570 bool "FlashPoint support"
571 depends on SCSI_BUSLOGIC && PCI
572 help
573 This option allows you to add FlashPoint support to the
574 BusLogic SCSI driver. The FlashPoint SCCB Manager code is
575 substantial, so users of MultiMaster Host Adapters may not
576 wish to include it.
577
578 config VMWARE_PVSCSI
579 tristate "VMware PVSCSI driver support"
580 depends on PCI && SCSI && X86
581 help
582 This driver supports VMware's para virtualized SCSI HBA.
583 To compile this driver as a module, choose M here: the
584 module will be called vmw_pvscsi.
585
586 config XEN_SCSI_FRONTEND
587 tristate "XEN SCSI frontend driver"
588 depends on SCSI && XEN
589 select XEN_XENBUS_FRONTEND
590 help
591 The XEN SCSI frontend driver allows the kernel to access SCSI Devices
592 within another guest OS (usually Dom0).
593 Only needed if the kernel is running in a XEN guest and generic
594 SCSI access to a device is needed.
595
596 config HYPERV_STORAGE
597 tristate "Microsoft Hyper-V virtual storage driver"
598 depends on SCSI && HYPERV
599 default HYPERV
600 help
601 Select this option to enable the Hyper-V virtual storage driver.
602
603 config LIBFC
604 tristate "LibFC module"
605 depends on SCSI_FC_ATTRS
606 select CRC32
607 ---help---
608 Fibre Channel library module
609
610 config LIBFCOE
611 tristate "LibFCoE module"
612 depends on LIBFC
613 ---help---
614 Library for Fibre Channel over Ethernet module
615
616 config FCOE
617 tristate "FCoE module"
618 depends on PCI
619 depends on LIBFCOE
620 ---help---
621 Fibre Channel over Ethernet module
622
623 config FCOE_FNIC
624 tristate "Cisco FNIC Driver"
625 depends on PCI && X86
626 depends on LIBFCOE
627 help
628 This is support for the Cisco PCI-Express FCoE HBA.
629
630 To compile this driver as a module, choose M here and read
631 <file:Documentation/scsi/scsi.txt>.
632 The module will be called fnic.
633
634 config SCSI_SNIC
635 tristate "Cisco SNIC Driver"
636 depends on PCI && SCSI
637 help
638 This is support for the Cisco PCI-Express SCSI HBA.
639
640 To compile this driver as a module, choose M here and read
641 <file:Documentation/scsi/scsi.txt>.
642 The module will be called snic.
643
644 config SCSI_SNIC_DEBUG_FS
645 bool "Cisco SNIC Driver Debugfs Support"
646 depends on SCSI_SNIC && DEBUG_FS
647 help
648 This enables to list debugging information from SNIC Driver
649 available via debugfs file system
650
651 config SCSI_DMX3191D
652 tristate "DMX3191D SCSI support"
653 depends on PCI && SCSI
654 select SCSI_SPI_ATTRS
655 help
656 This is support for Domex DMX3191D SCSI Host Adapters.
657
658 To compile this driver as a module, choose M here: the
659 module will be called dmx3191d.
660
661 config SCSI_DTC3280
662 tristate "DTC3180/3280 SCSI support"
663 depends on ISA && SCSI
664 select SCSI_SPI_ATTRS
665 select CHECK_SIGNATURE
666 help
667 This is support for DTC 3180/3280 SCSI Host Adapters. Please read
668 the SCSI-HOWTO, available from
669 <http://www.tldp.org/docs.html#howto>, and the file
670 <file:Documentation/scsi/dtc3x80.txt>.
671
672 To compile this driver as a module, choose M here: the
673 module will be called dtc.
674
675 config SCSI_EATA
676 tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
677 depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
678 ---help---
679 This driver supports all EATA/DMA-compliant SCSI host adapters. DPT
680 ISA and all EISA I/O addresses are probed looking for the "EATA"
681 signature. The addresses of all the PCI SCSI controllers reported
682 by the PCI subsystem are probed as well.
683
684 You want to read the start of <file:drivers/scsi/eata.c> and the
685 SCSI-HOWTO, available from
686 <http://www.tldp.org/docs.html#howto>.
687
688 To compile this driver as a module, choose M here: the
689 module will be called eata.
690
691 config SCSI_EATA_TAGGED_QUEUE
692 bool "enable tagged command queueing"
693 depends on SCSI_EATA
694 help
695 This is a feature of SCSI-2 which improves performance: the host
696 adapter can send several SCSI commands to a device's queue even if
697 previous commands haven't finished yet.
698 This is equivalent to the "eata=tc:y" boot option.
699
700 config SCSI_EATA_LINKED_COMMANDS
701 bool "enable elevator sorting"
702 depends on SCSI_EATA
703 help
704 This option enables elevator sorting for all probed SCSI disks and
705 CD-ROMs. It definitely reduces the average seek distance when doing
706 random seeks, but this does not necessarily result in a noticeable
707 performance improvement: your mileage may vary...
708 This is equivalent to the "eata=lc:y" boot option.
709
710 config SCSI_EATA_MAX_TAGS
711 int "maximum number of queued commands"
712 depends on SCSI_EATA
713 default "16"
714 help
715 This specifies how many SCSI commands can be maximally queued for
716 each probed SCSI device. You should reduce the default value of 16
717 only if you have disks with buggy or limited tagged command support.
718 Minimum is 2 and maximum is 62. This value is also the window size
719 used by the elevator sorting option above. The effective value used
720 by the driver for each probed SCSI device is reported at boot time.
721 This is equivalent to the "eata=mq:8" boot option.
722
723 config SCSI_EATA_PIO
724 tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
725 depends on (ISA || EISA || PCI) && SCSI && BROKEN
726 ---help---
727 This driver supports all EATA-PIO protocol compliant SCSI Host
728 Adapters like the DPT PM2001 and the PM2012A. EATA-DMA compliant
729 host adapters could also use this driver but are discouraged from
730 doing so, since this driver only supports hard disks and lacks
731 numerous features. You might want to have a look at the SCSI-HOWTO,
732 available from <http://www.tldp.org/docs.html#howto>.
733
734 To compile this driver as a module, choose M here: the
735 module will be called eata_pio.
736
737 config SCSI_FUTURE_DOMAIN
738 tristate "Future Domain 16xx SCSI/AHA-2920A support"
739 depends on (ISA || PCI) && SCSI
740 select CHECK_SIGNATURE
741 ---help---
742 This is support for Future Domain's 16-bit SCSI host adapters
743 (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
744 other adapters based on the Future Domain chipsets (Quantum
745 ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
746 It is explained in section 3.7 of the SCSI-HOWTO, available from
747 <http://www.tldp.org/docs.html#howto>.
748
749 NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
750 and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
751 controller support"). This Future Domain driver works with the older
752 Adaptec AHA-2920A boards with a Future Domain chip on them.
753
754 To compile this driver as a module, choose M here: the
755 module will be called fdomain.
756
757 config SCSI_GDTH
758 tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
759 depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
760 ---help---
761 Formerly called GDT SCSI Disk Array Controller Support.
762
763 This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI)
764 manufactured by Intel Corporation/ICP vortex GmbH. It is documented
765 in the kernel source in <file:drivers/scsi/gdth.c> and
766 <file:drivers/scsi/gdth.h>.
767
768 To compile this driver as a module, choose M here: the
769 module will be called gdth.
770
771 config SCSI_ISCI
772 tristate "Intel(R) C600 Series Chipset SAS Controller"
773 depends on PCI && SCSI
774 depends on X86
775 select SCSI_SAS_LIBSAS
776 ---help---
777 This driver supports the 6Gb/s SAS capabilities of the storage
778 control unit found in the Intel(R) C600 series chipset.
779
780 config SCSI_GENERIC_NCR5380
781 tristate "Generic NCR5380/53c400 SCSI PIO support"
782 depends on ISA && SCSI
783 select SCSI_SPI_ATTRS
784 ---help---
785 This is a driver for the old NCR 53c80 series of SCSI controllers
786 on boards using PIO. Most boards such as the Trantor T130 fit this
787 category, along with a large number of ISA 8bit controllers shipped
788 for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
789 you should select the specific driver for that card rather than
790 generic 5380 support.
791
792 It is explained in section 3.8 of the SCSI-HOWTO, available from
793 <http://www.tldp.org/docs.html#howto>. If it doesn't work out
794 of the box, you may have to change some settings in
795 <file:drivers/scsi/g_NCR5380.h>.
796
797 To compile this driver as a module, choose M here: the
798 module will be called g_NCR5380.
799
800 config SCSI_GENERIC_NCR5380_MMIO
801 tristate "Generic NCR5380/53c400 SCSI MMIO support"
802 depends on ISA && SCSI
803 select SCSI_SPI_ATTRS
804 ---help---
805 This is a driver for the old NCR 53c80 series of SCSI controllers
806 on boards using memory mapped I/O.
807 It is explained in section 3.8 of the SCSI-HOWTO, available from
808 <http://www.tldp.org/docs.html#howto>. If it doesn't work out
809 of the box, you may have to change some settings in
810 <file:drivers/scsi/g_NCR5380.h>.
811
812 To compile this driver as a module, choose M here: the
813 module will be called g_NCR5380_mmio.
814
815 config SCSI_GENERIC_NCR53C400
816 bool "Enable NCR53c400 extensions"
817 depends on SCSI_GENERIC_NCR5380
818 help
819 This enables certain optimizations for the NCR53c400 SCSI cards.
820 You might as well try it out. Note that this driver will only probe
821 for the Trantor T130B in its default configuration; you might have
822 to pass a command line option to the kernel at boot time if it does
823 not detect your card. See the file
824 <file:Documentation/scsi/g_NCR5380.txt> for details.
825
826 config SCSI_IPS
827 tristate "IBM ServeRAID support"
828 depends on PCI && SCSI
829 ---help---
830 This is support for the IBM ServeRAID hardware RAID controllers.
831 See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
832 and <http://www-947.ibm.com/support/entry/portal/docdisplay?brand=5000008&lndocid=SERV-RAID>
833 for more information. If this driver does not work correctly
834 without modification please contact the author by email at
835 <ipslinux@adaptec.com>.
836
837 To compile this driver as a module, choose M here: the
838 module will be called ips.
839
840 config SCSI_IBMVSCSI
841 tristate "IBM Virtual SCSI support"
842 depends on PPC_PSERIES
843 select SCSI_SRP_ATTRS
844 help
845 This is the IBM POWER Virtual SCSI Client
846
847 To compile this driver as a module, choose M here: the
848 module will be called ibmvscsi.
849
850 config SCSI_IBMVFC
851 tristate "IBM Virtual FC support"
852 depends on PPC_PSERIES && SCSI
853 depends on SCSI_FC_ATTRS
854 help
855 This is the IBM POWER Virtual FC Client
856
857 To compile this driver as a module, choose M here: the
858 module will be called ibmvfc.
859
860 config SCSI_IBMVFC_TRACE
861 bool "enable driver internal trace"
862 depends on SCSI_IBMVFC
863 default y
864 help
865 If you say Y here, the driver will trace all commands issued
866 to the adapter. Performance impact is minimal. Trace can be
867 dumped using /sys/class/scsi_host/hostXX/trace.
868
869 config SCSI_INITIO
870 tristate "Initio 9100U(W) support"
871 depends on PCI && SCSI
872 help
873 This is support for the Initio 91XXU(W) SCSI host adapter. Please
874 read the SCSI-HOWTO, available from
875 <http://www.tldp.org/docs.html#howto>.
876
877 To compile this driver as a module, choose M here: the
878 module will be called initio.
879
880 config SCSI_INIA100
881 tristate "Initio INI-A100U2W support"
882 depends on PCI && SCSI
883 help
884 This is support for the Initio INI-A100U2W SCSI host adapter.
885 Please read the SCSI-HOWTO, available from
886 <http://www.tldp.org/docs.html#howto>.
887
888 To compile this driver as a module, choose M here: the
889 module will be called a100u2w.
890
891 config SCSI_PPA
892 tristate "IOMEGA parallel port (ppa - older drives)"
893 depends on SCSI && PARPORT_PC
894 ---help---
895 This driver supports older versions of IOMEGA's parallel port ZIP
896 drive (a 100 MB removable media device).
897
898 Note that you can say N here if you have the SCSI version of the ZIP
899 drive: it will be supported automatically if you said Y to the
900 generic "SCSI disk support", above.
901
902 If you have the ZIP Plus drive or a more recent parallel port ZIP
903 drive (if the supplied cable with the drive is labeled "AutoDetect")
904 then you should say N here and Y to "IOMEGA parallel port (imm -
905 newer drives)", below.
906
907 For more information about this driver and how to use it you should
908 read the file <file:Documentation/scsi/ppa.txt>. You should also read
909 the SCSI-HOWTO, which is available from
910 <http://www.tldp.org/docs.html#howto>. If you use this driver,
911 you will still be able to use the parallel port for other tasks,
912 such as a printer; it is safe to compile both drivers into the
913 kernel.
914
915 To compile this driver as a module, choose M here: the
916 module will be called ppa.
917
918 config SCSI_IMM
919 tristate "IOMEGA parallel port (imm - newer drives)"
920 depends on SCSI && PARPORT_PC
921 ---help---
922 This driver supports newer versions of IOMEGA's parallel port ZIP
923 drive (a 100 MB removable media device).
924
925 Note that you can say N here if you have the SCSI version of the ZIP
926 drive: it will be supported automatically if you said Y to the
927 generic "SCSI disk support", above.
928
929 If you have the ZIP Plus drive or a more recent parallel port ZIP
930 drive (if the supplied cable with the drive is labeled "AutoDetect")
931 then you should say Y here; if you have an older ZIP drive, say N
932 here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
933
934 For more information about this driver and how to use it you should
935 read the file <file:Documentation/scsi/ppa.txt>. You should also read
936 the SCSI-HOWTO, which is available from
937 <http://www.tldp.org/docs.html#howto>. If you use this driver,
938 you will still be able to use the parallel port for other tasks,
939 such as a printer; it is safe to compile both drivers into the
940 kernel.
941
942 To compile this driver as a module, choose M here: the
943 module will be called imm.
944
945 config SCSI_IZIP_EPP16
946 bool "ppa/imm option - Use slow (but safe) EPP-16"
947 depends on SCSI_PPA || SCSI_IMM
948 ---help---
949 EPP (Enhanced Parallel Port) is a standard for parallel ports which
950 allows them to act as expansion buses that can handle up to 64
951 peripheral devices.
952
953 Some parallel port chipsets are slower than their motherboard, and
954 so we have to control the state of the chipset's FIFO queue every
955 now and then to avoid data loss. This will be done if you say Y
956 here.
957
958 Generally, saying Y is the safe option and slows things down a bit.
959
960 config SCSI_IZIP_SLOW_CTR
961 bool "ppa/imm option - Assume slow parport control register"
962 depends on SCSI_PPA || SCSI_IMM
963 help
964 Some parallel ports are known to have excessive delays between
965 changing the parallel port control register and good data being
966 available on the parallel port data/status register. This option
967 forces a small delay (1.0 usec to be exact) after changing the
968 control register to let things settle out. Enabling this option may
969 result in a big drop in performance but some very old parallel ports
970 (found in 386 vintage machines) will not work properly.
971
972 Generally, saying N is fine.
973
974 config SCSI_NCR53C406A
975 tristate "NCR53c406a SCSI support"
976 depends on ISA && SCSI
977 help
978 This is support for the NCR53c406a SCSI host adapter. For user
979 configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
980 in the kernel source. Also read the SCSI-HOWTO, available from
981 <http://www.tldp.org/docs.html#howto>.
982
983 To compile this driver as a module, choose M here: the
984 module will be called NCR53c406.
985
986 config SCSI_NCR_D700
987 tristate "NCR Dual 700 MCA SCSI support"
988 depends on MCA && SCSI
989 select SCSI_SPI_ATTRS
990 help
991 This is a driver for the MicroChannel Dual 700 card produced by
992 NCR and commonly used in 345x/35xx/4100 class machines. It always
993 tries to negotiate sync and uses tag command queueing.
994
995 Unless you have an NCR manufactured machine, the chances are that
996 you do not have this SCSI card, so say N.
997
998 config SCSI_LASI700
999 tristate "HP Lasi SCSI support for 53c700/710"
1000 depends on GSC && SCSI
1001 select SCSI_SPI_ATTRS
1002 help
1003 This is a driver for the SCSI controller in the Lasi chip found in
1004 many PA-RISC workstations & servers. If you do not know whether you
1005 have a Lasi chip, it is safe to say "Y" here.
1006
1007 config SCSI_SNI_53C710
1008 tristate "SNI RM SCSI support for 53c710"
1009 depends on SNI_RM && SCSI
1010 select SCSI_SPI_ATTRS
1011 select 53C700_LE_ON_BE
1012 help
1013 This is a driver for the onboard SCSI controller found in older
1014 SNI RM workstations & servers.
1015
1016 config 53C700_LE_ON_BE
1017 bool
1018 depends on SCSI_LASI700
1019 default y
1020
1021 config SCSI_STEX
1022 tristate "Promise SuperTrak EX Series support"
1023 depends on PCI && SCSI
1024 ---help---
1025 This driver supports Promise SuperTrak EX series storage controllers.
1026
1027 Promise provides Linux RAID configuration utility for these
1028 controllers. Please visit <http://www.promise.com> to download.
1029
1030 To compile this driver as a module, choose M here: the
1031 module will be called stex.
1032
1033 config 53C700_BE_BUS
1034 bool
1035 depends on SCSI_A4000T || SCSI_ZORRO7XX || MVME16x_SCSI || BVME6000_SCSI
1036 default y
1037
1038 config SCSI_SYM53C8XX_2
1039 tristate "SYM53C8XX Version 2 SCSI support"
1040 depends on PCI && SCSI
1041 select SCSI_SPI_ATTRS
1042 ---help---
1043 This driver supports the whole NCR53C8XX/SYM53C8XX family of
1044 PCI-SCSI controllers. It also supports the subset of LSI53C10XX
1045 Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
1046 language. It does not support LSI53C10XX Ultra-320 PCI-X SCSI
1047 controllers; you need to use the Fusion MPT driver for that.
1048
1049 Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
1050 information.
1051
1052 config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
1053 int "DMA addressing mode"
1054 depends on SCSI_SYM53C8XX_2
1055 default "1"
1056 ---help---
1057 This option only applies to PCI-SCSI chips that are PCI DAC
1058 capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
1059
1060 When set to 0, the driver will program the chip to only perform
1061 32-bit DMA. When set to 1, the chip will be able to perform DMA
1062 to addresses up to 1TB. When set to 2, the driver supports the
1063 full 64-bit DMA address range, but can only address 16 segments
1064 of 4 GB each. This limits the total addressable range to 64 GB.
1065
1066 Most machines with less than 4GB of memory should use a setting
1067 of 0 for best performance. If your machine has 4GB of memory
1068 or more, you should set this option to 1 (the default).
1069
1070 The still experimental value 2 (64 bit DMA addressing with 16
1071 x 4GB segments limitation) can be used on systems that require
1072 PCI address bits past bit 39 to be set for the addressing of
1073 memory using PCI DAC cycles.
1074
1075 config SCSI_SYM53C8XX_DEFAULT_TAGS
1076 int "Default tagged command queue depth"
1077 depends on SCSI_SYM53C8XX_2
1078 default "16"
1079 help
1080 This is the default value of the command queue depth the
1081 driver will announce to the generic SCSI layer for devices
1082 that support tagged command queueing. This value can be changed
1083 from the boot command line. This is a soft limit that cannot
1084 exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
1085
1086 config SCSI_SYM53C8XX_MAX_TAGS
1087 int "Maximum number of queued commands"
1088 depends on SCSI_SYM53C8XX_2
1089 default "64"
1090 help
1091 This option allows you to specify the maximum number of commands
1092 that can be queued to any device, when tagged command queuing is
1093 possible. The driver supports up to 256 queued commands per device.
1094 This value is used as a compiled-in hard limit.
1095
1096 config SCSI_SYM53C8XX_MMIO
1097 bool "Use memory mapped IO"
1098 depends on SCSI_SYM53C8XX_2
1099 default y
1100 help
1101 Memory mapped IO is faster than Port IO. Most people should
1102 answer Y here, but some machines may have problems. If you have
1103 to answer N here, please report the problem to the maintainer.
1104
1105 config SCSI_IPR
1106 tristate "IBM Power Linux RAID adapter support"
1107 depends on PCI && SCSI && ATA
1108 select FW_LOADER
1109 ---help---
1110 This driver supports the IBM Power Linux family RAID adapters.
1111 This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
1112 as IBM iSeries 5702, 5703, 5709, and 570A.
1113
1114 config SCSI_IPR_TRACE
1115 bool "enable driver internal trace"
1116 depends on SCSI_IPR
1117 default y
1118 help
1119 If you say Y here, the driver will trace all commands issued
1120 to the adapter. Performance impact is minimal. Trace can be
1121 dumped using /sys/bus/class/scsi_host/hostXX/trace.
1122
1123 config SCSI_IPR_DUMP
1124 bool "enable adapter dump support"
1125 depends on SCSI_IPR
1126 default y
1127 help
1128 If you say Y here, the driver will support adapter crash dump.
1129 If you enable this support, the iprdump daemon can be used
1130 to capture adapter failure analysis information.
1131
1132 config SCSI_ZALON
1133 tristate "Zalon SCSI support"
1134 depends on GSC && SCSI
1135 select SCSI_SPI_ATTRS
1136 help
1137 The Zalon is a GSC/HSC bus interface chip that sits between the
1138 PA-RISC processor and the NCR 53c720 SCSI controller on C100,
1139 C110, J200, J210 and some D, K & R-class machines. It's also
1140 used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
1141 Say Y here if you have one of these machines or cards.
1142
1143 config SCSI_NCR_Q720
1144 tristate "NCR Quad 720 MCA SCSI support"
1145 depends on MCA && SCSI
1146 select SCSI_SPI_ATTRS
1147 help
1148 This is a driver for the MicroChannel Quad 720 card produced by
1149 NCR and commonly used in 345x/35xx/4100 class machines. It always
1150 tries to negotiate sync and uses tag command queueing.
1151
1152 Unless you have an NCR manufactured machine, the chances are that
1153 you do not have this SCSI card, so say N.
1154
1155 config SCSI_NCR53C8XX_DEFAULT_TAGS
1156 int "default tagged command queue depth"
1157 depends on SCSI_ZALON || SCSI_NCR_Q720
1158 default "8"
1159 ---help---
1160 "Tagged command queuing" is a feature of SCSI-2 which improves
1161 performance: the host adapter can send several SCSI commands to a
1162 device's queue even if previous commands haven't finished yet.
1163 Because the device is intelligent, it can optimize its operations
1164 (like head positioning) based on its own request queue. Some SCSI
1165 devices don't implement this properly; if you want to disable this
1166 feature, enter 0 or 1 here (it doesn't matter which).
1167
1168 The default value is 8 and should be supported by most hard disks.
1169 This value can be overridden from the boot command line using the
1170 'tags' option as follows (example):
1171 'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
1172 4, set queue depth to 16 for target 2 and target 3 on controller 0
1173 and set queue depth to 10 for target 0 / lun 2 on controller 1.
1174
1175 The normal answer therefore is to go with the default 8 and to use
1176 a boot command line option for devices that need to use a different
1177 command queue depth.
1178
1179 There is no safe option other than using good SCSI devices.
1180
1181 config SCSI_NCR53C8XX_MAX_TAGS
1182 int "maximum number of queued commands"
1183 depends on SCSI_ZALON || SCSI_NCR_Q720
1184 default "32"
1185 ---help---
1186 This option allows you to specify the maximum number of commands
1187 that can be queued to any device, when tagged command queuing is
1188 possible. The default value is 32. Minimum is 2, maximum is 64.
1189 Modern hard disks are able to support 64 tags and even more, but
1190 do not seem to be faster when more than 32 tags are being used.
1191
1192 So, the normal answer here is to go with the default value 32 unless
1193 you are using very large hard disks with large cache (>= 1 MB) that
1194 are able to take advantage of more than 32 tagged commands.
1195
1196 There is no safe option and the default answer is recommended.
1197
1198 config SCSI_NCR53C8XX_SYNC
1199 int "synchronous transfers frequency in MHz"
1200 depends on SCSI_ZALON || SCSI_NCR_Q720
1201 default "20"
1202 ---help---
1203 The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
1204 rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80. The numbers
1205 are respectively the maximum data transfer rates in mega-transfers
1206 per second for each class. For example, a FAST-20 Wide 16 device is
1207 able to transfer data at 20 million 16 bit packets per second for a
1208 total rate of 40 MB/s.
1209
1210 You may specify 0 if you want to only use asynchronous data
1211 transfers. This is the safest and slowest option. Otherwise, specify
1212 a value between 5 and 80, depending on the capability of your SCSI
1213 controller. The higher the number, the faster the data transfer.
1214 Note that 80 should normally be ok since the driver decreases the
1215 value automatically according to the controller's capabilities.
1216
1217 Your answer to this question is ignored for controllers with NVRAM,
1218 since the driver will get this information from the user set-up. It
1219 also can be overridden using a boot setup option, as follows
1220 (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
1221 for FAST-20 synchronous data transfer (20 mega-transfers per
1222 second).
1223
1224 The normal answer therefore is not to go with the default but to
1225 select the maximum value 80 allowing the driver to use the maximum
1226 value supported by each controller. If this causes problems with
1227 your SCSI devices, you should come back and decrease the value.
1228
1229 There is no safe option other than using good cabling, right
1230 terminations and SCSI conformant devices.
1231
1232 config SCSI_NCR53C8XX_NO_DISCONNECT
1233 bool "not allow targets to disconnect"
1234 depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
1235 help
1236 This option is only provided for safety if you suspect some SCSI
1237 device of yours to not support properly the target-disconnect
1238 feature. In that case, you would say Y here. In general however, to
1239 not allow targets to disconnect is not reasonable if there is more
1240 than 1 device on a SCSI bus. The normal answer therefore is N.
1241
1242 config SCSI_PAS16
1243 tristate "PAS16 SCSI support"
1244 depends on ISA && SCSI
1245 select SCSI_SPI_ATTRS
1246 ---help---
1247 This is support for a SCSI host adapter. It is explained in section
1248 3.10 of the SCSI-HOWTO, available from
1249 <http://www.tldp.org/docs.html#howto>. If it doesn't work out
1250 of the box, you may have to change some settings in
1251 <file:drivers/scsi/pas16.h>.
1252
1253 To compile this driver as a module, choose M here: the
1254 module will be called pas16.
1255
1256 config SCSI_QLOGIC_FAS
1257 tristate "Qlogic FAS SCSI support"
1258 depends on ISA && SCSI
1259 ---help---
1260 This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
1261 FastSCSI! cards as well as any other card based on the FASXX chip
1262 (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
1263
1264 This driver does NOT support the PCI versions of these cards. The
1265 PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
1266 SCSI support"), below.
1267
1268 Information about this driver is contained in
1269 <file:Documentation/scsi/qlogicfas.txt>. You should also read the
1270 SCSI-HOWTO, available from
1271 <http://www.tldp.org/docs.html#howto>.
1272
1273 To compile this driver as a module, choose M here: the
1274 module will be called qlogicfas.
1275
1276 config SCSI_QLOGIC_1280
1277 tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
1278 depends on PCI && SCSI
1279 help
1280 Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
1281
1282 To compile this driver as a module, choose M here: the
1283 module will be called qla1280.
1284
1285 config SCSI_QLOGICPTI
1286 tristate "PTI Qlogic, ISP Driver"
1287 depends on SBUS && SCSI
1288 help
1289 This driver supports SBUS SCSI controllers from PTI or QLogic. These
1290 controllers are known under Solaris as qpti and in the openprom as
1291 PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
1292 driven by a different driver.
1293
1294 To compile this driver as a module, choose M here: the
1295 module will be called qlogicpti.
1296
1297 source "drivers/scsi/qla2xxx/Kconfig"
1298 source "drivers/scsi/qla4xxx/Kconfig"
1299
1300 config SCSI_LPFC
1301 tristate "Emulex LightPulse Fibre Channel Support"
1302 depends on PCI && SCSI
1303 depends on SCSI_FC_ATTRS
1304 select CRC_T10DIF
1305 help
1306 This lpfc driver supports the Emulex LightPulse
1307 Family of Fibre Channel PCI host adapters.
1308
1309 config SCSI_LPFC_DEBUG_FS
1310 bool "Emulex LightPulse Fibre Channel debugfs Support"
1311 depends on SCSI_LPFC && DEBUG_FS
1312 help
1313 This makes debugging information from the lpfc driver
1314 available via the debugfs filesystem.
1315
1316 config SCSI_SIM710
1317 tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
1318 depends on (EISA || MCA) && SCSI
1319 select SCSI_SPI_ATTRS
1320 ---help---
1321 This driver is for NCR53c710 based SCSI host adapters.
1322
1323 It currently supports Compaq EISA cards and NCR MCA cards
1324
1325 config SCSI_SYM53C416
1326 tristate "Symbios 53c416 SCSI support"
1327 depends on ISA && SCSI
1328 ---help---
1329 This is support for the sym53c416 SCSI host adapter, the SCSI
1330 adapter that comes with some HP scanners. This driver requires that
1331 the sym53c416 is configured first using some sort of PnP
1332 configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
1333 are using isapnp then you need to compile this driver as a module
1334 and then load it using insmod after isapnp has run. The parameters
1335 of the configured card(s) should be passed to the driver. The format
1336 is:
1337
1338 insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
1339
1340 To compile this driver as a module, choose M here: the
1341 module will be called sym53c416.
1342
1343 config SCSI_DC395x
1344 tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support"
1345 depends on PCI && SCSI
1346 ---help---
1347 This driver supports PCI SCSI host adapters based on the ASIC
1348 TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
1349
1350 This driver works, but is still in experimental status. So better
1351 have a bootable disk and a backup in case of emergency.
1352
1353 Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
1354
1355 To compile this driver as a module, choose M here: the
1356 module will be called dc395x.
1357
1358 config SCSI_AM53C974
1359 tristate "Tekram DC390(T) and Am53/79C974 SCSI support (new driver)"
1360 depends on PCI && SCSI
1361 select SCSI_SPI_ATTRS
1362 ---help---
1363 This driver supports PCI SCSI host adapters based on the Am53C974A
1364 chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
1365 PCscsi/PCnet (Am53/79C974) solutions.
1366 This is a new implementation base on the generic esp_scsi driver.
1367
1368 Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
1369
1370 Note that this driver does NOT support Tekram DC390W/U/F, which are
1371 based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
1372
1373 To compile this driver as a module, choose M here: the
1374 module will be called am53c974.
1375
1376 config SCSI_T128
1377 tristate "Trantor T128/T128F/T228 SCSI support"
1378 depends on ISA && SCSI
1379 select SCSI_SPI_ATTRS
1380 select CHECK_SIGNATURE
1381 ---help---
1382 This is support for a SCSI host adapter. It is explained in section
1383 3.11 of the SCSI-HOWTO, available from
1384 <http://www.tldp.org/docs.html#howto>. If it doesn't work out
1385 of the box, you may have to change some settings in
1386 <file:drivers/scsi/t128.h>. Note that Trantor was purchased by
1387 Adaptec, and some former Trantor products are being sold under the
1388 Adaptec name.
1389
1390 To compile this driver as a module, choose M here: the
1391 module will be called t128.
1392
1393 config SCSI_U14_34F
1394 tristate "UltraStor 14F/34F support"
1395 depends on ISA && SCSI && ISA_DMA_API
1396 ---help---
1397 This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
1398 The source at <file:drivers/scsi/u14-34f.c> contains some
1399 information about this hardware. If the driver doesn't work out of
1400 the box, you may have to change some settings in
1401 <file: drivers/scsi/u14-34f.c>. Read the SCSI-HOWTO, available from
1402 <http://www.tldp.org/docs.html#howto>. Note that there is also
1403 another driver for the same hardware: "UltraStor SCSI support",
1404 below. You should say Y to both only if you want 24F support as
1405 well.
1406
1407 To compile this driver as a module, choose M here: the
1408 module will be called u14-34f.
1409
1410 config SCSI_U14_34F_TAGGED_QUEUE
1411 bool "enable tagged command queueing"
1412 depends on SCSI_U14_34F
1413 help
1414 This is a feature of SCSI-2 which improves performance: the host
1415 adapter can send several SCSI commands to a device's queue even if
1416 previous commands haven't finished yet.
1417 This is equivalent to the "u14-34f=tc:y" boot option.
1418
1419 config SCSI_U14_34F_LINKED_COMMANDS
1420 bool "enable elevator sorting"
1421 depends on SCSI_U14_34F
1422 help
1423 This option enables elevator sorting for all probed SCSI disks and
1424 CD-ROMs. It definitely reduces the average seek distance when doing
1425 random seeks, but this does not necessarily result in a noticeable
1426 performance improvement: your mileage may vary...
1427 This is equivalent to the "u14-34f=lc:y" boot option.
1428
1429 config SCSI_U14_34F_MAX_TAGS
1430 int "maximum number of queued commands"
1431 depends on SCSI_U14_34F
1432 default "8"
1433 help
1434 This specifies how many SCSI commands can be maximally queued for
1435 each probed SCSI device. You should reduce the default value of 8
1436 only if you have disks with buggy or limited tagged command support.
1437 Minimum is 2 and maximum is 14. This value is also the window size
1438 used by the elevator sorting option above. The effective value used
1439 by the driver for each probed SCSI device is reported at boot time.
1440 This is equivalent to the "u14-34f=mq:8" boot option.
1441
1442 config SCSI_ULTRASTOR
1443 tristate "UltraStor SCSI support"
1444 depends on X86 && ISA && SCSI
1445 ---help---
1446 This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
1447 adapter family. This driver is explained in section 3.12 of the
1448 SCSI-HOWTO, available from
1449 <http://www.tldp.org/docs.html#howto>. If it doesn't work out
1450 of the box, you may have to change some settings in
1451 <file:drivers/scsi/ultrastor.h>.
1452
1453 Note that there is also another driver for the same hardware:
1454 "UltraStor 14F/34F support", above.
1455
1456 To compile this driver as a module, choose M here: the
1457 module will be called ultrastor.
1458
1459 config SCSI_NSP32
1460 tristate "Workbit NinjaSCSI-32Bi/UDE support"
1461 depends on PCI && SCSI && !64BIT
1462 help
1463 This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
1464 SCSI host adapter. Please read the SCSI-HOWTO, available from
1465 <http://www.tldp.org/docs.html#howto>.
1466
1467 To compile this driver as a module, choose M here: the
1468 module will be called nsp32.
1469
1470 config SCSI_WD719X
1471 tristate "Western Digital WD7193/7197/7296 support"
1472 depends on PCI && SCSI
1473 select EEPROM_93CX6
1474 ---help---
1475 This is a driver for Western Digital WD7193, WD7197 and WD7296 PCI
1476 SCSI controllers (based on WD33C296A chip).
1477
1478 config SCSI_DEBUG
1479 tristate "SCSI debugging host and device simulator"
1480 depends on SCSI
1481 select CRC_T10DIF
1482 help
1483 This pseudo driver simulates one or more hosts (SCSI initiators),
1484 each with one or more targets, each with one or more logical units.
1485 Defaults to one of each, creating a small RAM disk device. Many
1486 parameters found in the /sys/bus/pseudo/drivers/scsi_debug
1487 directory can be tweaked at run time.
1488 See <http://sg.danny.cz/sg/sdebug26.html> for more information.
1489 Mainly used for testing and best as a module. If unsure, say N.
1490
1491 config SCSI_MESH
1492 tristate "MESH (Power Mac internal SCSI) support"
1493 depends on PPC32 && PPC_PMAC && SCSI
1494 help
1495 Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
1496 SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
1497 other Power Macintoshes do). Say Y to include support for this SCSI
1498 adaptor.
1499
1500 To compile this driver as a module, choose M here: the
1501 module will be called mesh.
1502
1503 config SCSI_MESH_SYNC_RATE
1504 int "maximum synchronous transfer rate (MB/s) (0 = async)"
1505 depends on SCSI_MESH
1506 default "5"
1507 help
1508 On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
1509 drives a bus which is entirely internal to the machine (such as the
1510 7500, 7600, 8500, etc.), the MESH is capable of synchronous
1511 operation at up to 10 MB/s. On machines where the SCSI bus
1512 controlled by the MESH can have external devices connected, it is
1513 usually rated at 5 MB/s. 5 is a safe value here unless you know the
1514 MESH SCSI bus is internal only; in that case you can say 10. Say 0
1515 to disable synchronous operation.
1516
1517 config SCSI_MESH_RESET_DELAY_MS
1518 int "initial bus reset delay (ms) (0 = no reset)"
1519 depends on SCSI_MESH
1520 default "4000"
1521
1522 config SCSI_MAC53C94
1523 tristate "53C94 (Power Mac external SCSI) support"
1524 depends on PPC32 && PPC_PMAC && SCSI
1525 help
1526 On Power Macintoshes (and clones) with two SCSI buses, the external
1527 SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
1528 machines which only have one SCSI bus, such as the 7200, also use
1529 the 53C94. Say Y to include support for the 53C94.
1530
1531 To compile this driver as a module, choose M here: the
1532 module will be called mac53c94.
1533
1534 source "drivers/scsi/arm/Kconfig"
1535
1536 config JAZZ_ESP
1537 bool "MIPS JAZZ FAS216 SCSI support"
1538 depends on MACH_JAZZ && SCSI
1539 select SCSI_SPI_ATTRS
1540 help
1541 This is the driver for the onboard SCSI host adapter of MIPS Magnum
1542 4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
1543 systems.
1544
1545 config A3000_SCSI
1546 tristate "A3000 WD33C93A support"
1547 depends on AMIGA && SCSI
1548 help
1549 If you have an Amiga 3000 and have SCSI devices connected to the
1550 built-in SCSI controller, say Y. Otherwise, say N.
1551
1552 To compile this driver as a module, choose M here: the
1553 module will be called a3000.
1554
1555 config A2091_SCSI
1556 tristate "A2091/A590 WD33C93A support"
1557 depends on ZORRO && SCSI
1558 help
1559 If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
1560 say N.
1561
1562 To compile this driver as a module, choose M here: the
1563 module will be called a2091.
1564
1565 config GVP11_SCSI
1566 tristate "GVP Series II WD33C93A support"
1567 depends on ZORRO && SCSI
1568 ---help---
1569 If you have a Great Valley Products Series II SCSI controller,
1570 answer Y. Also say Y if you have a later model of GVP SCSI
1571 controller (such as the GVP A4008 or a Combo board). Otherwise,
1572 answer N. This driver does NOT work for the T-Rex series of
1573 accelerators from TekMagic and GVP-M.
1574
1575 To compile this driver as a module, choose M here: the
1576 module will be called gvp11.
1577
1578 config SCSI_A4000T
1579 tristate "A4000T NCR53c710 SCSI support"
1580 depends on AMIGA && SCSI
1581 select SCSI_SPI_ATTRS
1582 help
1583 If you have an Amiga 4000T and have SCSI devices connected to the
1584 built-in SCSI controller, say Y. Otherwise, say N.
1585
1586 To compile this driver as a module, choose M here: the
1587 module will be called a4000t.
1588
1589 config SCSI_ZORRO7XX
1590 tristate "Zorro NCR53c710 SCSI support"
1591 depends on ZORRO && SCSI
1592 select SCSI_SPI_ATTRS
1593 help
1594 Support for various NCR53c710-based SCSI controllers on Zorro
1595 expansion boards for the Amiga.
1596 This includes:
1597 - the Amiga 4091 Zorro III SCSI-2 controller,
1598 - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
1599 (info at
1600 <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
1601 - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
1602 accelerator card for the Amiga 1200,
1603 - the SCSI controller on the GVP Turbo 040/060 accelerator.
1604
1605 config ATARI_SCSI
1606 tristate "Atari native SCSI support"
1607 depends on ATARI && SCSI
1608 select SCSI_SPI_ATTRS
1609 select NVRAM
1610 ---help---
1611 If you have an Atari with built-in NCR5380 SCSI controller (TT,
1612 Falcon, ...) say Y to get it supported. Of course also, if you have
1613 a compatible SCSI controller (e.g. for Medusa).
1614
1615 To compile this driver as a module, choose M here: the
1616 module will be called atari_scsi.
1617
1618 This driver supports both styles of NCR integration into the
1619 system: the TT style (separate DMA), and the Falcon style (via
1620 ST-DMA, replacing ACSI). It does NOT support other schemes, like
1621 in the Hades (without DMA).
1622
1623 config ATARI_SCSI_TOSHIBA_DELAY
1624 bool "Long delays for Toshiba CD-ROMs"
1625 depends on ATARI_SCSI
1626 help
1627 This option increases the delay after a SCSI arbitration to
1628 accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
1629 use a Toshiba CD-ROM drive; otherwise, the option is not needed and
1630 would impact performance a bit, so say N.
1631
1632 config ATARI_SCSI_RESET_BOOT
1633 bool "Reset SCSI-devices at boottime"
1634 depends on ATARI_SCSI
1635 help
1636 Reset the devices on your Atari whenever it boots. This makes the
1637 boot process fractionally longer but may assist recovery from errors
1638 that leave the devices with SCSI operations partway completed.
1639
1640 config MAC_SCSI
1641 tristate "Macintosh NCR5380 SCSI"
1642 depends on MAC && SCSI=y
1643 select SCSI_SPI_ATTRS
1644 help
1645 This is the NCR 5380 SCSI controller included on most of the 68030
1646 based Macintoshes. If you have one of these say Y and read the
1647 SCSI-HOWTO, available from
1648 <http://www.tldp.org/docs.html#howto>.
1649
1650 config SCSI_MAC_ESP
1651 tristate "Macintosh NCR53c9[46] SCSI"
1652 depends on MAC && SCSI
1653 select SCSI_SPI_ATTRS
1654 help
1655 This is the NCR 53c9x SCSI controller found on most of the 68040
1656 based Macintoshes.
1657
1658 To compile this driver as a module, choose M here: the module
1659 will be called mac_esp.
1660
1661 config MVME147_SCSI
1662 bool "WD33C93 SCSI driver for MVME147"
1663 depends on MVME147 && SCSI=y
1664 select SCSI_SPI_ATTRS
1665 help
1666 Support for the on-board SCSI controller on the Motorola MVME147
1667 single-board computer.
1668
1669 config MVME16x_SCSI
1670 tristate "NCR53C710 SCSI driver for MVME16x"
1671 depends on MVME16x && SCSI
1672 select SCSI_SPI_ATTRS
1673 help
1674 The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
1675 SCSI controller chip. Almost everyone using one of these boards
1676 will want to say Y to this question.
1677
1678 config BVME6000_SCSI
1679 tristate "NCR53C710 SCSI driver for BVME6000"
1680 depends on BVME6000 && SCSI
1681 select SCSI_SPI_ATTRS
1682 help
1683 The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
1684 SCSI controller chip. Almost everyone using one of these boards
1685 will want to say Y to this question.
1686
1687 config SUN3_SCSI
1688 tristate "Sun3 NCR5380 SCSI"
1689 depends on SUN3 && SCSI
1690 select SCSI_SPI_ATTRS
1691 help
1692 This option will enable support for the OBIO (onboard io) NCR5380
1693 SCSI controller found in the Sun 3/50 and 3/60, as well as for
1694 "Sun3" type VME scsi controllers also based on the NCR5380.
1695 General Linux information on the Sun 3 series (now discontinued)
1696 is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
1697
1698 config SUN3X_ESP
1699 bool "Sun3x ESP SCSI"
1700 depends on SUN3X && SCSI=y
1701 select SCSI_SPI_ATTRS
1702 help
1703 The ESP was an on-board SCSI controller used on Sun 3/80
1704 machines. Say Y here to compile in support for it.
1705
1706 config SCSI_SUNESP
1707 tristate "Sparc ESP Scsi Driver"
1708 depends on SBUS && SCSI
1709 select SCSI_SPI_ATTRS
1710 help
1711 This is the driver for the Sun ESP SCSI host adapter. The ESP
1712 chipset is present in most SPARC SBUS-based computers and
1713 supports the Emulex family of ESP SCSI chips (esp100, esp100A,
1714 esp236, fas101, fas236) as well as the Qlogic fas366 SCSI chip.
1715
1716 To compile this driver as a module, choose M here: the
1717 module will be called sun_esp.
1718
1719 config ZFCP
1720 tristate "FCP host bus adapter driver for IBM eServer zSeries"
1721 depends on S390 && QDIO && SCSI
1722 depends on SCSI_FC_ATTRS
1723 help
1724 If you want to access SCSI devices attached to your IBM eServer
1725 zSeries by means of Fibre Channel interfaces say Y.
1726 For details please refer to the documentation provided by IBM at
1727 <http://oss.software.ibm.com/developerworks/opensource/linux390>
1728
1729 This driver is also available as a module. This module will be
1730 called zfcp. If you want to compile it as a module, say M here
1731 and read <file:Documentation/kbuild/modules.txt>.
1732
1733 config SCSI_PMCRAID
1734 tristate "PMC SIERRA Linux MaxRAID adapter support"
1735 depends on PCI && SCSI && NET
1736 ---help---
1737 This driver supports the PMC SIERRA MaxRAID adapters.
1738
1739 config SCSI_PM8001
1740 tristate "PMC-Sierra SPC 8001 SAS/SATA Based Host Adapter driver"
1741 depends on PCI && SCSI
1742 select SCSI_SAS_LIBSAS
1743 help
1744 This driver supports PMC-Sierra PCIE SAS/SATA 8x6G SPC 8001 chip
1745 based host adapters.
1746
1747 config SCSI_BFA_FC
1748 tristate "Brocade BFA Fibre Channel Support"
1749 depends on PCI && SCSI
1750 depends on SCSI_FC_ATTRS
1751 help
1752 This bfa driver supports all Brocade PCIe FC/FCOE host adapters.
1753
1754 To compile this driver as a module, choose M here. The module will
1755 be called bfa.
1756
1757 config SCSI_VIRTIO
1758 tristate "virtio-scsi support"
1759 depends on VIRTIO
1760 help
1761 This is the virtual HBA driver for virtio. If the kernel will
1762 be used in a virtual machine, say Y or M.
1763
1764 source "drivers/scsi/csiostor/Kconfig"
1765
1766 endif # SCSI_LOWLEVEL
1767
1768 source "drivers/scsi/pcmcia/Kconfig"
1769
1770 source "drivers/scsi/device_handler/Kconfig"
1771
1772 source "drivers/scsi/osd/Kconfig"
1773
1774 endmenu