1 AT_BANNER([ovn_controller_vtep])
3 # OVN_CONTROLLER_VTEP_START
5 # Starts the test with a setup with vtep device. Each test case must first
8 # Uses vtep-ovs to simulate the vtep switch 'br-vtep' with two physical ports
11 # Configures ovn-nb with a logical switch 'br-test'.
14 m4_define([OVN_CONTROLLER_VTEP_START],
16 # this will cause skip when 'make check' using Windows setup.
17 AT_SKIP_IF([test $HAVE_PYTHON = no])
19 dnl Create databases (ovn-nb, ovn-sb, vtep).
20 AT_CHECK([ovsdb-tool create vswitchd.db $abs_top_srcdir/vswitchd/vswitch.ovsschema])
21 for daemon in ovn-nb ovn-sb vtep; do
22 AT_CHECK([ovsdb-tool create $daemon.db $abs_top_srcdir/${daemon%%-*}/${daemon}.ovsschema])
25 dnl Start ovsdb-server.
26 AT_CHECK([ovsdb-server --detach --no-chdir --pidfile --log-file --remote=punix:$OVS_RUNDIR/db.sock vswitchd.db vtep.db ovn-nb.db ovn-sb.db], [0], [], [stderr])
27 on_exit "kill `cat ovsdb-server.pid`"
28 AT_CHECK([[sed < stderr '
29 /vlog|INFO|opened log file/d
30 /ovsdb_server|INFO|ovsdb-server (Open vSwitch)/d']])
31 AT_CAPTURE_FILE([ovsdb-server.log])
33 dnl Start ovs-vswitchd.
34 AT_CHECK([ovs-vswitchd --enable-dummy --disable-system --detach --no-chdir --pidfile --log-file -vvconn -vofproto_dpif], [0], [], [stderr])
35 AT_CAPTURE_FILE([ovs-vswitchd.log])
36 on_exit "kill `cat ovs-vswitchd.pid`"
37 AT_CHECK([[sed < stderr '
38 /ovs_numa|INFO|Discovered /d
39 /vlog|INFO|opened log file/d
40 /vswitchd|INFO|ovs-vswitchd (Open vSwitch)/d
42 /ofproto|INFO|using datapath ID/d
43 /ofproto|INFO|datapath ID changed to fedcba9876543210/d']])
44 AT_CHECK([ovs-vsctl -- add-br br-vtep \
45 -- set bridge br-vtep datapath-type=dummy other-config:datapath-id=fedcba9876543210 other-config:hwaddr=aa:55:aa:55:00:00 protocols=[[OpenFlow10,OpenFlow11,OpenFlow12,OpenFlow13,OpenFlow14,OpenFlow15]] fail-mode=secure \
46 -- add-port br-vtep p0 -- set Interface p0 type=dummy ofport_request=1 \
47 -- add-port br-vtep p1 -- set Interface p1 type=dummy ofport_request=2])
50 AT_CHECK([vtep-ctl add-ps br-vtep -- set Physical_Switch br-vtep tunnel_ips=1.2.3.4])
51 AT_CHECK([ovs-vtep --log-file=ovs-vtep.log --pidfile=ovs-vtep.pid --detach br-vtep \], [0], [], [stderr])
52 on_exit "kill `cat ovs-vtep.pid`"
53 AT_CHECK([[sed < stderr '
54 /vlog|INFO|opened log file/d']])
55 # waits until ovs-vtep starts up.
56 OVS_WAIT_UNTIL([test -n "`vtep-ctl show | grep Physical_Port`"])
59 AT_CHECK([ovn-nbctl lswitch-add br-test])
60 AT_CHECK([ovn-northd --detach --pidfile --log-file --ovnnb-db=unix:$OVS_RUNDIR/db.sock --ovnsb-db=unix:$OVS_RUNDIR/db.sock], [0], [], [stderr])
61 on_exit "kill `cat ovn-northd.pid`"
62 AT_CHECK([[sed < stderr '
63 /vlog|INFO|opened log file/d']])
64 AT_CAPTURE_FILE([ovn-northd.log])
66 dnl Start ovn-controllger-vtep.
67 AT_CHECK([ovn-controller-vtep --detach --pidfile --log-file --vtep-db=unix:$OVS_RUNDIR/db.sock --ovnsb-db=unix:$OVS_RUNDIR/db.sock], [0], [], [stderr])
68 AT_CAPTURE_FILE([ovn-controller-vtep.log])
69 on_exit "kill `cat ovn-controller-vtep.pid`"
70 AT_CHECK([[sed < stderr '
71 /vlog|INFO|opened log file/d
72 /reconnect|INFO|/d']])
75 # OVN_CONTROLLER_VTEP_STOP
77 # So many exits... Yeah, we started a lot daemons~
79 m4_define([OVN_CONTROLLER_VTEP_STOP],
80 [# removes all 'Broken pipe' warning logs from ovsdb-server.log. this is in
81 # that *ctl command (e.g. ovn-nbctl) exits right after committing the change
82 # to database. however, in reaction, some daemon (e.g. ovn-controller-vtep)
83 # may immediately update the database. this later update may cause database
84 # sending update back to *ctl command if *ctl has not proceeded to exit yet.
85 # and if *ctl command exits before database calling send, the send from
86 # database will fail with 'Broken pipe' error.
87 AT_CHECK([check_logs "$1
89 AT_CHECK([ovs-appctl -t ovs-vtep exit])
90 AT_CHECK([ovs-appctl -t ovn-northd exit])
91 AT_CHECK([ovs-appctl -t ovn-controller-vtep exit])
92 # makes sure ovn-controller-vtep exits.
93 OVS_WAIT_UNTIL([test ! -f ovn-controller-vtep.pid])
94 AT_CHECK([ovs-appctl -t ovsdb-server exit])
95 AT_CHECK([ovs-appctl -t ovs-vswitchd exit])])
97 # Adds logical port for a vtep gateway chassis in ovn-nb database.
99 # $1: logical switch name in ovn-nb database
100 # $2: logical port name
101 # $3: physical vtep gateway name
102 # $4: logical switch name on vtep gateway chassis
103 m4_define([OVN_NB_ADD_VTEP_PORT], [
104 AT_CHECK([ovn-nbctl lport-add $1 $2])
105 AT_CHECK([ovn-nbctl lport-set-type $2 vtep])
106 AT_CHECK([ovn-nbctl lport-set-options $2 vtep-physical-switch=$3 vtep-logical-switch=$4])
109 ##############################################
111 # tests chassis related updates.
112 AT_SETUP([ovn-controller-vtep - test chassis])
113 OVN_CONTROLLER_VTEP_START
115 # verifies the initial ovn-sb db configuration.
116 OVS_WAIT_UNTIL([test -n "`ovn-sbctl show | grep Chassis`"])
117 AT_CHECK([ovn-sbctl show], [0], [dnl
123 # deletes the chassis via ovn-sbctl and check that it is readded back
125 AT_CHECK([ovn-sbctl chassis-del br-vtep])
126 OVS_WAIT_UNTIL([test -n "`grep WARN ovn-controller-vtep.log`"])
127 AT_CHECK([sed -n 's/^.*\(|WARN|.*\)$/\1/p' ovn-controller-vtep.log], [0], [dnl
128 |WARN|Chassis for VTEP physical switch (br-vtep) disappears, maybe deleted by ovn-sbctl, adding it back
131 # changes the tunnel_ip on physical switch, watches the update of chassis's
133 AT_CHECK([vtep-ctl set Physical_Switch br-vtep tunnel_ips=1.2.3.5])
134 OVS_WAIT_UNTIL([test -n "`ovn-sbctl show | grep 1\.2\.3\.5`"])
135 AT_CHECK([ovn-sbctl --columns=ip list Encap | cut -d ':' -f2 | tr -d ' '], [0], [dnl
139 # adds vlan_bindings to physical ports.
140 AT_CHECK([vtep-ctl add-ls lswitch0 -- bind-ls br-vtep p0 100 lswitch0 -- bind-ls br-vtep p0 200 lswitch0 -- bind-ls br-vtep p1 300 lswitch0])
141 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Chassis | grep -- lswitch0`"])
142 AT_CHECK([ovn-sbctl --columns=vtep_logical_switches list Chassis | cut -d ':' -f2 | tr -d ' ' ], [0], [dnl
146 # adds another logical switch and new vlan_bindings.
147 AT_CHECK([vtep-ctl add-ls lswitch1 -- bind-ls br-vtep p0 300 lswitch1])
148 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Chassis | grep -- lswitch1`"])
149 AT_CHECK([ovn-sbctl --columns=vtep_logical_switches list Chassis | cut -d ':' -f2 | tr -d ' '], [0], [dnl
150 [["lswitch0","lswitch1"]]
153 # unbinds one port from lswitch0, nothing should change.
154 AT_CHECK([vtep-ctl unbind-ls br-vtep p0 200])
155 OVS_WAIT_UNTIL([test -z "`vtep-ctl --columns=vlan_bindings list physical_port p0 | grep -- '200='`"])
156 AT_CHECK([ovn-sbctl --columns=vtep_logical_switches list Chassis | cut -d ':' -f2 | tr -d ' ' ], [0], [dnl
157 [["lswitch0","lswitch1"]]
160 # unbinds all ports from lswitch0.
161 AT_CHECK([vtep-ctl unbind-ls br-vtep p0 100 -- unbind-ls br-vtep p1 300])
162 OVS_WAIT_UNTIL([test -z "`ovn-sbctl list Chassis | grep -- br-vtep_lswitch0`"])
163 AT_CHECK([ovn-sbctl --columns=vtep_logical_switches list Chassis | cut -d ':' -f2 | tr -d ' ' ], [0], [dnl
167 # unbinds all ports from lswitch1.
168 AT_CHECK([vtep-ctl unbind-ls br-vtep p0 300])
169 OVS_WAIT_UNTIL([test -z "`ovn-sbctl list Chassis | grep -- br-vtep_lswitch1`"])
170 AT_CHECK([ovn-sbctl --columns=vtep_logical_switches list Chassis | cut -d ':' -f2 | tr -d ' '], [0], [dnl
174 OVN_CONTROLLER_VTEP_STOP([/Chassis for VTEP physical switch (br-vtep) disappears/d])
178 # Tests binding updates.
179 AT_SETUP([ovn-controller-vtep - test binding 1])
180 OVN_CONTROLLER_VTEP_START
182 # adds logical switch 'lswitch0' and vlan_bindings.
183 AT_CHECK([vtep-ctl add-ls lswitch0 -- bind-ls br-vtep p0 100 lswitch0 -- bind-ls br-vtep p1 300 lswitch0])
184 # adds lport in ovn-nb database, and sets the type and options.
185 OVN_NB_ADD_VTEP_PORT([br-test], [br-vtep_lswitch0], [br-vtep], [lswitch0])
186 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Port_Binding | grep br-vtep_lswitch0`"])
187 # should see one binding, associated to chassis of 'br-vtep'.
188 chassis_uuid=$(ovn-sbctl --columns=_uuid list Chassis br-vtep | cut -d ':' -f2 | tr -d ' ')
189 AT_CHECK_UNQUOTED([ovn-sbctl --columns=chassis list Port_Binding br-vtep_lswitch0 | cut -d ':' -f2 | tr -d ' '], [0], [dnl
193 # adds another logical switch 'lswitch1' and vlan_bindings.
194 AT_CHECK([vtep-ctl add-ls lswitch1 -- bind-ls br-vtep p0 200 lswitch1])
195 # adds lport in ovn-nb database for lswitch1.
196 OVN_NB_ADD_VTEP_PORT([br-test], [br-vtep_lswitch1], [br-vtep], [lswitch1])
197 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Port_Binding | grep -- br-vtep_lswitch1`"])
198 # This is allowed, but not recommended, to have two vlan_bindings (to different vtep logical switches)
199 # from one vtep gateway physical port in one ovn-nb logical swithch.
200 AT_CHECK_UNQUOTED([ovn-sbctl --columns=chassis list Port_Binding | cut -d ':' -f2 | tr -d ' ' | sort -d], [0], [dnl
206 # adds another lport in ovn-nb database for lswitch0.
207 OVN_NB_ADD_VTEP_PORT([br-test], [br-vtep_lswitch0_dup], [br-vtep], [lswitch0])
208 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Port_Binding | grep -- br-vtep_lswitch0_dup`"])
209 # it is not allowed to have more than one ovn-nb logical port for the same
210 # vtep logical switch on a vtep gateway chassis, so should still see only
211 # two port_binding entries bound.
212 AT_CHECK_UNQUOTED([ovn-sbctl --columns=chassis list Port_Binding | cut -d ':' -f2 | tr -d ' ' | sort -d], [0], [dnl
219 # confirms the warning log.
220 AT_CHECK([sed -n 's/^.*\(|WARN|.*\)$/\1/p' ovn-controller-vtep.log | sed 's/([[-_0-9a-z]][[-_0-9a-z]]*)/()/g' | uniq], [0], [dnl
221 |WARN|logical switch (), on vtep gateway chassis () has already been associated with logical port (), ignore logical port ()
224 # deletes physical ports from vtep.
225 AT_CHECK([ovs-vsctl del-port p0 -- del-port p1])
226 AT_CHECK([vtep-ctl del-port br-vtep p0 -- del-port br-vtep p1])
227 OVS_WAIT_UNTIL([test -z "`ovn-sbctl list Chassis | grep -- br-vtep_lswitch`"])
228 # should see empty chassis column in both binding entries.
229 AT_CHECK_UNQUOTED([ovn-sbctl --columns=chassis list Port_Binding | cut -d ':' -f2 | tr -d ' ' | sort], [0], [dnl
237 OVN_CONTROLLER_VTEP_STOP([/has already been associated with logical port/d])
241 # Tests corner case: Binding the vtep logical switch from two different
243 AT_SETUP([ovn-controller-vtep - test binding 2])
244 OVN_CONTROLLER_VTEP_START
246 # adds logical switch 'lswitch0' and vlan_bindings.
247 AT_CHECK([vtep-ctl add-ls lswitch0 -- bind-ls br-vtep p0 100 lswitch0])
248 # adds lport in ovn-nb database, and sets the type and options.
249 OVN_NB_ADD_VTEP_PORT([br-test], [br-vtep_lswitch0], [br-vtep], [lswitch0])
250 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Port_Binding | grep br-vtep_lswitch0`"])
252 # adds another lswitch 'br-void' in ovn-nb database.
253 AT_CHECK([ovn-nbctl lswitch-add br-void])
254 # adds another vtep pswitch 'br-vtep-void' in vtep database.
255 AT_CHECK([vtep-ctl add-ps br-vtep-void -- add-port br-vtep-void p0-void -- bind-ls br-vtep-void p0-void 100 lswitch0])
256 # adds a conflicting logical port (both br-vtep_lswitch0 and br-vtep-void_lswitch0
257 # are bound to the same logical switch, but they are on different datapath).
258 OVN_NB_ADD_VTEP_PORT([br-void], [br-vtep-void_lswitch0], [br-vtep-void], [lswitch0])
259 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Port_Binding | grep br-vtep-void_lswitch0`"])
260 OVS_WAIT_UNTIL([test -n "`grep WARN ovn-controller-vtep.log`"])
261 # confirms the warning log.
262 AT_CHECK([sed -n 's/^.*\(|WARN|.*\)$/\1/p' ovn-controller-vtep.log | sed 's/([[-_0-9a-z]][[-_0-9a-z]]*)/()/g;s/(with tunnel key [[0-9]][[0-9]]*)/()/g' | uniq], [0], [dnl
263 |WARN|logical switch (), on vtep gateway chassis () has already been associated with logical datapath (), ignore logical port () which belongs to logical datapath ()
266 # then deletes 'br-void' and 'br-vtep-void', should see 'br-vtep_lswitch0'
268 AT_CHECK([ovn-nbctl lswitch-del br-void])
269 # adds another vtep pswitch 'br-vtep-void' in vtep database.
270 AT_CHECK([vtep-ctl del-ps br-vtep-void])
271 OVS_WAIT_UNTIL([test -z "`ovn-sbctl list Port_Binding | grep br-vtep-void_lswitch0`"])
272 chassis_uuid=$(ovn-sbctl --columns=_uuid list Chassis br-vtep | cut -d ':' -f2 | tr -d ' ')
273 AT_CHECK_UNQUOTED([ovn-sbctl --columns=chassis list Port_Binding br-vtep_lswitch0 | cut -d ':' -f2 | tr -d ' '], [0], [dnl
277 OVN_CONTROLLER_VTEP_STOP([/has already been associated with logical datapath/d])
281 # Tests vtep module vtep logical switch tunnel key update.
282 AT_SETUP([ovn-controller-vtep - test vtep-lswitch])
283 OVN_CONTROLLER_VTEP_START
285 # creates the logical switch in vtep and adds the corresponding logical
287 AT_CHECK([vtep-ctl add-ls lswitch0 -- bind-ls br-vtep p0 100 lswitch0])
288 OVN_NB_ADD_VTEP_PORT([br-test], [br-vtep_lswitch0], [br-vtep], [lswitch0])
289 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Port_Binding | grep -- br-vtep_lswitch0`"])
291 # retrieves the expected tunnel key.
292 datapath_uuid=$(ovn-sbctl --columns=datapath list Port_Binding br-vtep_lswitch0 | cut -d ':' -f2 | tr -d ' ')
293 tunnel_key=$(ovn-sbctl --columns=tunnel_key list Datapath_Binding ${datapath_uuid} | cut -d ':' -f2 | tr -d ' ')
294 OVS_WAIT_UNTIL([test -z "`vtep-ctl --columns=tunnel_key list Logical_Switch | grep 0`"])
295 # checks the vtep logical switch tunnel key configuration.
296 AT_CHECK_UNQUOTED([vtep-ctl --columns=tunnel_key list Logical_Switch | cut -d ':' -f2 | tr -d ' '], [0], [dnl
300 # creates a second physical switch in vtep database, and binds its p0 vlan-100
301 # to the same logical switch 'lswitch0'.
302 AT_CHECK([vtep-ctl add-ps br-vtep-void -- add-port br-vtep-void p0 -- bind-ls br-vtep-void p0 100 lswitch0])
303 OVS_WAIT_UNTIL([test -n "`ovn-sbctl --columns=name list Chassis | grep -- br-vtep-void`"])
304 OVN_NB_ADD_VTEP_PORT([br-test], [br-vtep-void_lswitch0], [br-vtep-void], [lswitch0])
305 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Port_Binding | grep -- br-vtep-void_lswitch0`"])
307 # checks the vtep logical switch tunnel key configuration.
308 AT_CHECK_UNQUOTED([vtep-ctl --columns=tunnel_key list Logical_Switch | cut -d ':' -f2 | tr -d ' '], [0], [dnl
312 # now, deletes br-vtep-void.
313 AT_CHECK([vtep-ctl del-ps br-vtep-void])
314 OVS_WAIT_UNTIL([test -z "`ovn-sbctl --columns=name list Chassis | grep -- br-vtep-void`"])
315 # checks the vtep logical switch tunnel key configuration.
316 AT_CHECK_UNQUOTED([vtep-ctl --columns=tunnel_key list Logical_Switch | cut -d ':' -f2 | tr -d ' '], [0], [dnl
320 # changes the ovn-nb logical port type so that it is no longer
322 AT_CHECK([ovn-nbctl lport-set-type br-vtep_lswitch0 void])
323 OVS_WAIT_UNTIL([test -z "`vtep-ctl --columns=tunnel_key list Logical_Switch | grep 1`"])
324 # now should see the tunnel key reset.
325 AT_CHECK([vtep-ctl --columns=tunnel_key list Logical_Switch | cut -d ':' -f2 | tr -d ' '], [0], [dnl
329 OVN_CONTROLLER_VTEP_STOP
333 # Tests vtep module 'Ucast_Macs_Remote's.
334 AT_SETUP([ovn-controller-vtep - test vtep-macs 1])
335 OVN_CONTROLLER_VTEP_START
337 # creates a simple logical network with the vtep device and a fake hv chassis
339 AT_CHECK([ovn-nbctl lport-add br-test vif0])
340 AT_CHECK([ovn-nbctl lport-set-addresses vif0 f0:ab:cd:ef:01:02])
341 AT_CHECK([ovn-sbctl chassis-add ch0 vxlan 1.2.3.5])
342 AT_CHECK([ovn-sbctl lport-bind vif0 ch0])
344 # creates the logical switch in vtep and adds the corresponding logical
346 AT_CHECK([vtep-ctl add-ls lswitch0 -- bind-ls br-vtep p0 100 lswitch0])
347 OVN_NB_ADD_VTEP_PORT([br-test], [br-vtep_lswitch0], [br-vtep], [lswitch0])
348 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Port_Binding | grep br-vtep_lswitch0`"])
350 # adds another lswitch 'br-void' in ovn-nb database.
351 AT_CHECK([ovn-nbctl lswitch-add br-void])
352 # adds fake hv chassis 'ch1'.
353 AT_CHECK([ovn-nbctl lport-add br-void vif1])
354 AT_CHECK([ovn-nbctl lport-set-addresses vif1 f0:ab:cd:ef:01:02])
355 AT_CHECK([ovn-sbctl chassis-add ch1 vxlan 1.2.3.6])
356 AT_CHECK([ovn-sbctl lport-bind vif1 ch1])
357 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Port_Binding | grep vif1`"])
359 # checks Ucast_Macs_Remote creation.
360 OVS_WAIT_UNTIL([test -n "`vtep-ctl list Ucast_Macs_Remote | grep _uuid`"])
361 AT_CHECK([vtep-ctl --columns=MAC list Ucast_Macs_Remote | cut -d ':' -f2- | tr -d ' '], [0], [dnl
365 # checks physical locator creation.
366 OVS_WAIT_UNTIL([test -n "`vtep-ctl list Physical_Locator | grep _uuid`"])
367 AT_CHECK([vtep-ctl --columns=dst_ip list Physical_Locator | cut -d ':' -f2 | tr -d ' ' | grep -v 1.2.3.4 | sed '/^$/d'], [0], [dnl
371 # checks tunnel creation by ovs-vtep.
372 OVS_WAIT_UNTIL([test -n "`ovs-vsctl list Interface bfd1.2.3.5`"])
373 AT_CHECK([ovs-vsctl --columns=options list Interface bfd1.2.3.5 | cut -d ':' -f2 | tr -d ' '], [0], [dnl
374 {remote_ip="1.2.3.5"}
377 # adds another mac to lport.
378 AT_CHECK([ovn-nbctl lport-set-addresses vif0 f0:ab:cd:ef:01:02 f0:ab:cd:ef:01:03])
379 OVS_WAIT_UNTIL([test -n "`vtep-ctl list Ucast_Macs_Remote | grep 03`"])
380 AT_CHECK([vtep-ctl --columns=MAC list Ucast_Macs_Remote | cut -d ':' -f2- | tr -d ' ' | sort], [0], [dnl
386 # removes one mac to lport.
387 AT_CHECK([ovn-nbctl lport-set-addresses vif0 f0:ab:cd:ef:01:03])
388 OVS_WAIT_UNTIL([test -z "`vtep-ctl --columns=MAC list Ucast_Macs_Remote | grep 02`"])
389 AT_CHECK([vtep-ctl --columns=MAC list Ucast_Macs_Remote | cut -d ':' -f2- | tr -d ' ' | sort], [0], [dnl
393 # migrates mac to lport vif1 on 'br-void'.
394 AT_CHECK([ovn-nbctl lport-set-addresses vif0])
395 AT_CHECK([ovn-nbctl lport-set-addresses vif1 f0:ab:cd:ef:01:03])
396 OVS_WAIT_UNTIL([test -z "`vtep-ctl --columns=MAC list Ucast_Macs_Remote | grep 03`"])
397 AT_CHECK([vtep-ctl --columns=MAC list Ucast_Macs_Remote | cut -d ':' -f2- | tr -d ' ' | sort], [0], [dnl
400 OVN_CONTROLLER_VTEP_STOP
404 # Tests vtep module 'Ucast_Macs_Remote's (corner cases).
405 AT_SETUP([ovn-controller-vtep - test vtep-macs 2])
406 OVN_CONTROLLER_VTEP_START
408 # creates a simple logical network with the vtep device and a fake hv chassis
410 AT_CHECK([ovn-nbctl lport-add br-test vif0])
411 AT_CHECK([ovn-nbctl lport-set-addresses vif0 f0:ab:cd:ef:01:02])
412 AT_CHECK([ovn-sbctl chassis-add ch0 vxlan 1.2.3.5])
413 AT_CHECK([ovn-sbctl lport-bind vif0 ch0])
415 # creates another vif in the same logical switch with duplicate mac.
416 AT_CHECK([ovn-nbctl lport-add br-test vif1])
417 AT_CHECK([ovn-nbctl lport-set-addresses vif1 f0:ab:cd:ef:01:02])
418 AT_CHECK([ovn-sbctl lport-bind vif1 ch0])
420 # creates the logical switch in vtep and adds the corresponding logical
422 AT_CHECK([vtep-ctl add-ls lswitch0 -- bind-ls br-vtep p0 100 lswitch0])
423 OVN_NB_ADD_VTEP_PORT([br-test], [br-vtep_lswitch0], [br-vtep], [lswitch0])
424 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Port_Binding | grep br-vtep_lswitch0`"])
426 # checks Ucast_Macs_Remote creation. Should still only be one entry, since duplicate
427 # mac in the same logical switch is not allowed.
428 OVS_WAIT_UNTIL([test -n "`vtep-ctl list Ucast_Macs_Remote | grep _uuid`"])
429 AT_CHECK([vtep-ctl --columns=MAC list Ucast_Macs_Remote | cut -d ':' -f2- | tr -d ' '], [0], [dnl
432 # confirms the warning log.
433 OVS_WAIT_UNTIL([test -n "`grep WARN ovn-controller-vtep.log`"])
434 AT_CHECK([sed -n 's/^.*\(|WARN|.*\)$/\1/p' ovn-controller-vtep.log | sed 's/([[-_:0-9a-z]][[-_:0-9a-z]]*)/()/g' | uniq], [0], [dnl
435 |WARN|MAC address () has already been known to be on logical port () in the same logical datapath, so just ignore this logical port ()
439 AT_CHECK([ovn-nbctl lport-del vif1])
441 # adds another lswitch 'br-void' in ovn-nb database.
442 AT_CHECK([ovn-nbctl lswitch-add br-void])
443 # adds fake hv chassis 'ch1' and vif1 with same mac address as vif0.
444 AT_CHECK([ovn-nbctl lport-add br-void vif1])
445 AT_CHECK([ovn-nbctl lport-set-addresses vif1 f0:ab:cd:ef:01:02])
446 AT_CHECK([ovn-sbctl chassis-add ch1 vxlan 1.2.3.6])
447 AT_CHECK([ovn-sbctl lport-bind vif1 ch1])
448 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Port_Binding | grep vif1`"])
450 # creates another logical switch in vtep and adds the corresponding logical
452 AT_CHECK([vtep-ctl add-ls lswitch1 -- bind-ls br-vtep p0 200 lswitch1])
453 OVN_NB_ADD_VTEP_PORT([br-void], [br-void_lswitch1], [br-vtep], [lswitch1])
454 OVS_WAIT_UNTIL([test -n "`ovn-sbctl list Port_Binding | grep br-void_lswitch1`"])
456 # checks Ucast_Macs_Remote creation. Should see two entries since it is allowed
457 # to have duplicate macs in different logical switches.
458 OVS_WAIT_UNTIL([test `vtep-ctl --columns=MAC list Ucast_Macs_Remote | grep 02 | wc -l` -gt 1])
459 AT_CHECK([vtep-ctl --columns=MAC list Ucast_Macs_Remote | cut -d ':' -f2- | tr -d ' ' | sort], [0], [dnl
465 OVN_CONTROLLER_VTEP_STOP([/has already been known to be on logical port/d])