/* clang-format off */
static struct log_ref ferr_zebra_err[] = {
{
- .code = ZEBRA_ERR_LM_RESPONSE,
+ .code = EC_ZEBRA_LM_RESPONSE,
.title = "Error reading response from label manager",
.description = "Zebra could not read the ZAPI header from the label manager",
.suggestion = "Wait for the error to resolve on its own. If it does not resolve, restart Zebra.",
},
{
- .code = ZEBRA_ERR_LM_NO_SUCH_CLIENT,
+ .code = EC_ZEBRA_LM_NO_SUCH_CLIENT,
.title = "Label manager could not find ZAPI client",
.description = "Zebra was unable to find a ZAPI client matching the given protocol and instance number.",
.suggestion = "Ensure clients which use the label manager are properly configured and running.",
},
{
- .code = ZEBRA_ERR_LM_RELAY_FAILED,
+ .code = EC_ZEBRA_LM_RELAY_FAILED,
.title = "Zebra could not relay label manager response",
.description = "Zebra found the client and instance to relay the label manager response or request to, but was not able to do so, possibly because the connection was closed.",
.suggestion = "Ensure clients which use the label manager are properly configured and running.",
},
{
- .code = ZEBRA_ERR_LM_BAD_INSTANCE,
+ .code = EC_ZEBRA_LM_BAD_INSTANCE,
.title = "Mismatch between ZAPI instance and encoded message instance",
.description = "While relaying a request to the external label manager, Zebra noticed that the instance number encoded in the message did not match the client instance number.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_LM_EXHAUSTED_LABELS,
+ .code = EC_ZEBRA_LM_EXHAUSTED_LABELS,
.title = "Zebra label manager used all available labels",
.description = "Zebra is unable to assign additional label chunks because it has exhausted its assigned label range.",
.suggestion = "Make the label range bigger and restart Zebra.",
},
{
- .code = ZEBRA_ERR_LM_DAEMON_MISMATCH,
+ .code = EC_ZEBRA_LM_DAEMON_MISMATCH,
.title = "Daemon mismatch when releasing label chunks",
.description = "Zebra noticed a mismatch between a label chunk and a protocol daemon number or instance when releasing unused label chunks.",
.suggestion = "Ignore this error.",
},
{
- .code = ZEBRA_ERR_LM_UNRELEASED_CHUNK,
+ .code = EC_ZEBRA_LM_UNRELEASED_CHUNK,
.title = "Zebra did not free any label chunks",
.description = "Zebra's chunk cleanup procedure ran, but no label chunks were released.",
.suggestion = "Ignore this error.",
},
{
- .code = ZEBRA_ERR_DP_INVALID_RC,
+ .code = EC_ZEBRA_DP_INVALID_RC,
.title = "Dataplane returned invalid status code",
.description = "The underlying dataplane responded to a Zebra message or other interaction with an unrecognized, unknown or invalid status code.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_WQ_NONEXISTENT,
+ .code = EC_ZEBRA_WQ_NONEXISTENT,
.title = "A necessary work queue does not exist.",
.description = "A necessary work queue does not exist.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_FEC_ADD_FAILED,
+ .code = EC_ZEBRA_FEC_ADD_FAILED,
.title = "Failed to add FEC for MPLS client",
.description = "A client requested a label binding for a new FEC, but Zebra was unable to add the FEC to its internal table.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_FEC_RM_FAILED,
+ .code = EC_ZEBRA_FEC_RM_FAILED,
.title = "Failed to remove FEC for MPLS client",
.description = "Zebra was unable to find and remove a FEC in its internal table.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_IRDP_LEN_MISMATCH,
+ .code = EC_ZEBRA_IRDP_LEN_MISMATCH,
.title = "IRDP message length mismatch",
.description = "The length encoded in the IP TLV does not match the length of the packet received.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_RNH_UNKNOWN_FAMILY,
+ .code = EC_ZEBRA_RNH_UNKNOWN_FAMILY,
.title = "Attempted to perform nexthop update for unknown address family",
.description = "Zebra attempted to perform a nexthop update for unknown address family",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_DP_INSTALL_FAIL,
+ .code = EC_ZEBRA_DP_INSTALL_FAIL,
.title = "Dataplane installation failure",
.description = "Installation of routes to underlying dataplane failed.",
.suggestion = "Check all configuration parameters for correctness.",
},
{
- .code = ZEBRA_ERR_TABLE_LOOKUP_FAILED,
+ .code = EC_ZEBRA_DP_DELETE_FAIL,
+ .title = "Dataplane deletion failure",
+ .description = "Deletion of routes from underlying dataplane failed.",
+ .suggestion = "Check all configuration parameters for correctness.",
+ },
+ {
+ .code = EC_ZEBRA_TABLE_LOOKUP_FAILED,
.title = "Zebra table lookup failed",
.description = "Zebra attempted to look up a table for a particular address family and subsequent address family, but didn't find anything.",
.suggestion = "If you entered a command to trigger this error, make sure you entered the arguments correctly. Check your config file for any potential errors. If these look correct, seek help.",
},
{
- .code = ZEBRA_ERR_NETLINK_NOT_AVAILABLE,
+ .code = EC_ZEBRA_NETLINK_NOT_AVAILABLE,
.title = "Netlink backend not available",
.description = "FRR was not compiled with support for Netlink. Any operations that require Netlink will fail.",
.suggestion = "Recompile FRR with Netlink, or install a package that supports this feature.",
},
{
- .code = ZEBRA_ERR_PROTOBUF_NOT_AVAILABLE,
+ .code = EC_ZEBRA_PROTOBUF_NOT_AVAILABLE,
.title = "Protocol Buffers backend not available",
.description = "FRR was not compiled with support for Protocol Buffers. Any operations that require Protobuf will fail.",
.suggestion = "Recompile FRR with Protobuf support, or install a package that supports this feature.",
},
{
- .code = ZEBRA_ERR_TM_EXHAUSTED_IDS,
+ .code = EC_ZEBRA_TM_EXHAUSTED_IDS,
.title = "Table manager used all available IDs",
.description = "Zebra's table manager used up all IDs available to it and can't assign any more.",
.suggestion = "Reconfigure Zebra with a larger range of table IDs.",
},
{
- .code = ZEBRA_ERR_TM_DAEMON_MISMATCH,
+ .code = EC_ZEBRA_TM_DAEMON_MISMATCH,
.title = "Daemon mismatch when releasing table chunks",
.description = "Zebra noticed a mismatch between a table ID chunk and a protocol daemon number instance when releasing unused table chunks.",
.suggestion = "Ignore this error.",
},
{
- .code = ZEBRA_ERR_TM_UNRELEASED_CHUNK,
+ .code = EC_ZEBRA_TM_UNRELEASED_CHUNK,
.title = "Zebra did not free any table chunks",
.description = "Zebra's table chunk cleanup procedure ran, but no table chunks were released.",
.suggestion = "Ignore this error.",
},
{
- .code = ZEBRA_ERR_UNKNOWN_FAMILY,
+ .code = EC_ZEBRA_UNKNOWN_FAMILY,
.title = "Address family specifier unrecognized",
.description = "Zebra attempted to process information from somewhere that included an address family specifier, but did not recognize the provided specifier.",
.suggestion = "Ensure that your configuration is correct. If it is, notify a developer.",
},
{
- .code = ZEBRA_ERR_TM_WRONG_PROTO,
+ .code = EC_ZEBRA_TM_WRONG_PROTO,
.title = "Incorrect protocol for table manager client",
.description = "Zebra's table manager only accepts connections from daemons managing dynamic routing protocols, but received a connection attempt from a daemon that does not meet this criterion.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_PROTO_OR_INSTANCE_MISMATCH,
+ .code = EC_ZEBRA_PROTO_OR_INSTANCE_MISMATCH,
.title = "Mismatch between message and client protocol and/or instance",
.description = "Zebra detected a mismatch between a client's protocol and/or instance numbers versus those stored in a message transiting its socket.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_LM_CANNOT_ASSIGN_CHUNK,
+ .code = EC_ZEBRA_LM_CANNOT_ASSIGN_CHUNK,
.title = "Label manager unable to assign label chunk",
.description = "Zebra's label manager was unable to assign a label chunk to client.",
.suggestion = "Ensure that Zebra has a sufficient label range available and that there is not a range collision.",
},
{
- .code = ZEBRA_ERR_LM_ALIENS,
+ .code = EC_ZEBRA_LM_ALIENS,
.title = "Label request from unidentified client",
.description = "Zebra's label manager received a label request from an unidentified client.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_TM_CANNOT_ASSIGN_CHUNK,
+ .code = EC_ZEBRA_TM_CANNOT_ASSIGN_CHUNK,
.title = "Table manager unable to assign table chunk",
.description = "Zebra's table manager was unable to assign a table chunk to a client.",
.suggestion = "Ensure that Zebra has sufficient table ID range available and that there is not a range collision.",
},
{
- .code = ZEBRA_ERR_TM_ALIENS,
+ .code = EC_ZEBRA_TM_ALIENS,
.title = "Table request from unidentified client",
.description = "Zebra's table manager received a table request from an unidentified client.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_RECVBUF,
+ .code = EC_ZEBRA_RECVBUF,
.title = "Cannot set receive buffer size",
.description = "Socket receive buffer size could not be set in the kernel",
.suggestion = "Ignore this error.",
},
{
- .code = ZEBRA_ERR_UNKNOWN_NLMSG,
+ .code = EC_ZEBRA_UNKNOWN_NLMSG,
.title = "Unknown Netlink message type",
.description = "Zebra received a Netlink message with an unrecognized type field.",
.suggestion = "Verify that you are running the latest version of FRR to ensure kernel compatibility. If the problem persists, notify a developer.",
},
{
- .code = ZEBRA_ERR_RECVMSG_OVERRUN,
+ .code = EC_ZEBRA_RECVMSG_OVERRUN,
.title = "Receive buffer overrun",
.description = "The kernel's buffer for a socket has been overrun, rendering the socket invalid.",
.suggestion = "Zebra will restart itself. Notify a developer if this issue shows up frequently.",
},
{
- .code = ZEBRA_ERR_NETLINK_LENGTH_ERROR,
+ .code = EC_ZEBRA_NETLINK_LENGTH_ERROR,
.title = "Netlink message length mismatch",
.description = "Zebra received a Netlink message with incorrect length fields.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_NETLINK_LENGTH_ERROR,
+ .code = EC_ZEBRA_NETLINK_LENGTH_ERROR,
.title = "Netlink message length mismatch",
.description = "Zebra received a Netlink message with incorrect length fields.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_UNEXPECTED_MESSAGE,
+ .code = EC_ZEBRA_UNEXPECTED_MESSAGE,
.title = "Received unexpected response from kernel",
.description = "Received unexpected response from the kernel via Netlink.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_NETLINK_BAD_SEQUENCE,
+ .code = EC_ZEBRA_NETLINK_BAD_SEQUENCE,
.title = "Bad sequence number in Netlink message",
.description = "Zebra received a Netlink message with a bad sequence number.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_BAD_MULTIPATH_NUM,
+ .code = EC_ZEBRA_BAD_MULTIPATH_NUM,
.title = "Multipath number was out of valid range",
.description = "Multipath number specified to Zebra must be in the appropriate range",
.suggestion = "Provide a multipath number that is within its accepted range",
},
{
- .code = ZEBRA_ERR_PREFIX_PARSE_ERROR,
+ .code = EC_ZEBRA_PREFIX_PARSE_ERROR,
.title = "String could not be parsed as IP prefix",
.description = "There was an attempt to parse a string as an IPv4 or IPv6 prefix, but the string could not be parsed and this operation failed.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_MAC_ADD_FAILED,
+ .code = EC_ZEBRA_MAC_ADD_FAILED,
.title = "Failed to add MAC address to interface",
.description = "Zebra attempted to assign a MAC address to a vxlan interface but failed",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_VNI_DEL_FAILED,
+ .code = EC_ZEBRA_VNI_DEL_FAILED,
.title = "Failed to delete VNI",
.description = "Zebra attempted to delete a VNI entry and failed",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_VTEP_ADD_FAILED,
+ .code = EC_ZEBRA_VTEP_ADD_FAILED,
.title = "Adding remote VTEP failed",
.description = "Zebra attempted to add a remote VTEP and failed.",
.suggestion = "Notify a developer.",
},
{
- .code = ZEBRA_ERR_VNI_ADD_FAILED,
+ .code = EC_ZEBRA_VNI_ADD_FAILED,
.title = "Adding VNI failed",
.description = "Zebra attempted to add a VNI hash to an interface and failed",
.suggestion = "Notify a developer.",
},
+ {
+ .code = EC_ZEBRA_NS_NOTIFY_READ,
+ .title = "Zebra failed to read namespace inotify information",
+ .description = "Zebra received an event from inotify, but failed to read what it was.",
+ .suggestion = "Notify a developer.",
+ },
+ /* Warnings */
+ {
+ .code = EC_ZEBRAING_LM_PROTO_MISMATCH,
+ .title =
+ "Zebra label manager received malformed label request",
+ .description =
+ "Zebra's label manager received a label request from a client whose protocol type does not match the protocol field received in the message.",
+ .suggestion =
+ "This is a bug. Please report it.",
+ },
+ {
+ .code = EC_ZEBRA_LSP_INSTALL_FAILURE,
+ .title =
+ "Zebra failed to install LSP into the kernel",
+ .description =
+ "Zebra made an attempt to install a label switched path, but the kernel indicated that the installation was not successful.",
+ .suggestion =
+ "Wait for Zebra to reattempt installation.",
+ },
+ {
+ .code = EC_ZEBRA_LSP_DELETE_FAILURE,
+ .title =
+ "Zebra failed to remove LSP from the kernel",
+ .description =
+ "Zebra made an attempt to remove a label switched path, but the kernel indicated that the deletion was not successful.",
+ .suggestion =
+ "Wait for Zebra to reattempt deletion.",
+ },
+ {
+ .code = EC_ZEBRA_MPLS_SUPPORT_DISABLED,
+ .title =
+ "Zebra will not run with MPLS support",
+ .description =
+ "Zebra noticed that the running kernel does not support MPLS, so it disabled MPLS support.",
+ .suggestion =
+ "If you want MPLS support, upgrade the kernel to a version that provides MPLS support.",
+ },
+ {
+ .code = EC_ZEBRA_SYSCTL_FAILED,
+ .title = "A call to sysctl() failed",
+ .description =
+ "sysctl() returned a nonzero exit code, indicating an error.",
+ .suggestion =
+ "The log message should contain further details on the specific error that occurred; investigate the reported error.",
+ },
+ {
+ .code = EC_ZEBRA_NS_VRF_CREATION_FAILED,
+ .title =
+ "Zebra failed to create namespace VRF",
+ .description =
+ "Zebra failed to create namespace VRF",
+ .suggestion = "",
+ },
+ {
+ .code = EC_ZEBRA_NS_DELETION_FAILED_NO_VRF,
+ .title =
+ "Zebra attempted to delete nonexistent namespace",
+ .description =
+ "Zebra attempted to delete a particular namespace, but no VRF associated with that namespace could be found to delete.",
+ .suggestion = "Please report this bug.",
+ },
+ {
+ .code = EC_ZEBRA_IFLIST_FAILED,
+ .title =
+ "Zebra interface listing failed",
+ .description =
+ "Zebra encountered an error attempting to query sysctl for a list of interfaces on the system.",
+ .suggestion =
+ "Check that Zebra is running with the appropriate permissions. If it is, please report this as a bug.",
+ },
+ {
+ .code = EC_ZEBRA_IRDP_BAD_CHECKSUM,
+ .title =
+ "Zebra received ICMP packet with invalid checksum",
+ .description =
+ "Zebra received an ICMP packet with a bad checksum and has silently ignored it.",
+ .suggestion =
+ "If the problem continues to occur, investigate the source of the bad ICMP packets.",
+ },
+ {
+ .code = EC_ZEBRA_IRDP_BAD_TYPE_CODE,
+ .title =
+ "Zebra received ICMP packet with bad type code",
+ .description =
+ "Zebra received an ICMP packet with a bad code for the message type and has silently ignored it.",
+ .suggestion =
+ "If the problem continues to occur, investigate the source of the bad ICMP packets.",
+ },
+ {
+ .code = EC_ZEBRA_IRDP_BAD_RX_FLAGS,
+ .title =
+ "Zebra received IRDP packet while operating in wrong mode",
+ .description =
+ "Zebra received a multicast IRDP packet while operating in unicast mode, or vice versa.",
+ .suggestion =
+ "If you wish to receive the messages, change your IRDP settings accordingly.",
+ },
+ {
+ .code = EC_ZEBRA_IRDP_BAD_TYPE,
+ .title =
+ "Zebra received IRDP packet with bad type",
+ .description =
+ "THIS IS BULLSHIT REMOVE ME",
+ .suggestion = "asdf",
+ },
+ {
+ .code = EC_ZEBRA_RNH_NO_TABLE,
+ .title =
+ "Zebra could not find table for next hop",
+ .description =
+ "Zebra attempted to add a next hop but could not find the appropriate table to install it in.",
+ .suggestion = "Please report this bug.",
+ },
+ {
+ .code = EC_ZEBRA_FPM_FORMAT_UNKNOWN,
+ .title =
+ "Unknown message format for Zebra's FPM module",
+ .description =
+ "Zebra's FPM module takes an argument which specifies the message format to use, but the format was either not provided or was not a valid format. The FPM interface will be disabled.",
+ .suggestion =
+ "Provide or correct the module argument to provide a valid format. See documentation for further information.",
+ },
+ {
+ .code = EC_ZEBRA_CLIENT_IO_ERROR,
+ .title =
+ "Zebra client connection failed",
+ .description =
+ "A Zebra client encountered an I/O error and is shutting down. This can occur under normal circumstances, such as when FRR is restarting or shutting down; it can also happen if the daemon crashed. Usually this warning can be ignored.",
+ .suggestion =
+ "Ignore this warning, it is mostly informational.",
+ },
+ {
+ .code = EC_ZEBRA_CLIENT_WRITE_FAILED,
+ .title =
+ "Zebra failed to send message to client",
+ .description =
+ "Zebra attempted to send a message to one of its clients, but the write operation failed. The connection will be closed.",
+ .suggestion =
+ "Ignore this warning, it is mostly informational.",
+ },
+ {
+ .code = EC_ZEBRA_NETLINK_INVALID_AF,
+ .title =
+ "Zebra received Netlink message with invalid family",
+ .description =
+ "Zebra received a Netlink message with an invalid address family.",
+ .suggestion =
+ "Inspect the logged address family and submit it with a bug report.",
+ },
+ {
+ .code = EC_ZEBRA_REMOVE_ADDR_UNKNOWN_SUBNET,
+ .title =
+ "Zebra tried to remove address from unknown subnet",
+ .description =
+ "Zebra attempted to remove an address from an unknown subnet.",
+ .suggestion =
+ "This is a bug, please report it.",
+ },
+ {
+ .code = EC_ZEBRA_REMOVE_UNREGISTERED_ADDR,
+ .title =
+ "Zebra tried to remove unregistered address",
+ .description =
+ "Zebra attempted to remove an address from a subnet it was not registered on.",
+ .suggestion =
+ "This is a bug, please report it.",
+ },
+ {
+ .code = EC_ZEBRA_PTM_NOT_READY,
+ .title =
+ "Interface is up but PTM check has not completed",
+ .description =
+ "Zebra noticed that an interface came up and attempted to perform its usual setup procedures, but the PTM check failed and the operation was aborted.",
+ .suggestion =
+ "If the problem persists, ensure that the interface is actually up and that PTM is functioning properly.",
+ },
+ {
+ .code = EC_ZEBRA_UNSUPPORTED_V4_SRCDEST,
+ .title =
+ "Kernel rejected sourcedest route",
+ .description =
+ "Zebra attempted to install a sourcedest route into the kernel, but the kernel did not acknowledge its installation. The route is unsupported.",
+ .suggestion =
+ "Check configuration values for correctness",
+ },
+ {
+ .code = EC_ZEBRA_UNKNOWN_INTERFACE,
+ .title =
+ "Zebra encountered an unknown interface specifier",
+ .description =
+ "Zebra was asked to look up an interface with a given name or index, but could not find the interface corresponding to the given name or index.",
+ .suggestion =
+ "Check configuration values for correctness.",
+ },
+ {
+ .code = EC_ZEBRA_VRF_NOT_FOUND,
+ .title =
+ "Zebra could not find the specified VRF",
+ .description =
+ "Zebra tried to look up a VRF, either by name or ID, and could not find it. This could be due to internal inconsistency (a bug) or a configuration error.",
+ .suggestion =
+ "Check configuration values for correctness. If values are correct, please file a bug report.",
+ },
+ {
+ .code = EC_ZEBRA_MORE_NH_THAN_MULTIPATH,
+ .title =
+ "More nexthops were provided than the configured multipath limit",
+ .description =
+ "A route with multiple nexthops was given, but the number of nexthops exceeded the configured multipath limit.",
+ .suggestion =
+ "Reduce the number of nexthops, or increase the multipath limit.",
+ },
+ {
+ .code = EC_ZEBRA_NEXTHOP_CREATION_FAILED,
+ .title =
+ "Zebra failed to create one or more nexthops",
+ .description =
+ "While attempting to create nexthops for a route installation operation, Zebra found that it was unable to create one or more of the given nexthops.",
+ .suggestion =
+ "Check configuration values for correctness. If they are correct, report this as a bug.",
+ },
+ {
+ .code = EC_ZEBRA_RX_SRCDEST_WRONG_AFI,
+ .title =
+ "Zebra received sourcedest route install without IPv6 address family",
+ .description =
+ "Zebra received a message from a client requesting a sourcedest route installation, but the address family was not set to IPv6. Only IPv6 is supported for sourcedest routing.",
+ .suggestion =
+ "This is a bug; please report it.",
+ },
+ {
+ .code = EC_ZEBRA_PSEUDOWIRE_EXISTS,
+ .title =
+ "Zebra received an installation / creation request for a pseudowire that already exists",
+ .description =
+ "Zebra received an installation or creation request for a pseudowire that already exists, so the installation / creation has been skipped.",
+ .suggestion =
+ "This message is informational.",
+ },
+ {
+ .code = EC_ZEBRA_PSEUDOWIRE_NONEXISTENT,
+ .title =
+ "Zebra received an uninstallation / deletion request for a pseudowire that already exists",
+ .description =
+ "Zebra received an uninstallation / deletion request for a pseudowire that doesn't exist, so the uninstallation / deletion has been skipped.",
+ .suggestion =
+ "This message is informational.",
+ },
+ {
+ .code = EC_ZEBRA_PSEUDOWIRE_UNINSTALL_NOT_FOUND,
+ .title =
+ "Zebra received uninstall request for a pseudowire that doesn't exist",
+ .description =
+ "Zebra received an uninstall request for a pseudowire that doesn't exist, so the uninstallation has been skipped.",
+ .suggestion =
+ "This message is informational.",
+ },
+ {
+ .code = EC_ZEBRA_NO_IFACE_ADDR,
+ .title = "No address on interface",
+ .description =
+ "Zebra attempted to retrieve a connected address for an interface, but the interface had no connected addresses.",
+ .suggestion =
+ "This warning is situational; it is usually informative but can indicate a misconfiguration.",
+ },
+ {
+ .code = EC_ZEBRA_IFACE_ADDR_ADD_FAILED,
+ .title =
+ "Zebra failed to add address to interface",
+ .description =
+ "Zebra attempted to add an address to an interface but was unsuccessful.",
+ .suggestion =
+ "Check configuration values for correctness.",
+ },
+ {
+ .code = EC_ZEBRA_IRDP_CANNOT_ACTIVATE_IFACE,
+ .title =
+ "Zebra could not enable IRDP on interface",
+ .description =
+ "Zebra attempted to enable IRDP on an interface, but could not create the IRDP socket. The system may be out of socket resources, or privilege elevation may have failed.",
+ .suggestion =
+ "Verify that Zebra has the appropriate privileges and that the system has sufficient socket resources.",
+ },
+ {
+ .code = EC_ZEBRA_IRDP_IFACE_DOWN,
+ .title =
+ "Zebra attempted to enable IRDP on an interface, but the interface was down",
+ .description = "Zebra attempted to enable IRDP on an interface, but the interface was down.",
+ .suggestion =
+ "Bring up the interface that IRDP is desired on.",
+ },
+ {
+ .code = EC_ZEBRA_IRDP_IFACE_MCAST_DISABLED,
+ .title =
+ "Zebra cannot enable IRDP on interface because multicast is disabled",
+ .description =
+ "Zebra attempted to enable IRDP on an interface, but multicast functionality was not enabled on the interface.",
+ .suggestion =
+ "Enable multicast on the interface.",
+ },
+ {
+ .code = EC_ZEBRA_NETLINK_EXTENDED_WARNING,
+ .title =
+ "Zebra received warning message from Netlink",
+ .description =
+ "Zebra received a warning message from Netlink",
+ .suggestion =
+ "This message is informational. See the Netlink error message for details.",
+ },
+ {
+ .code = EC_ZEBRA_NAMESPACE_DIR_INACCESSIBLE,
+ .title =
+ "Zebra could not access /var/run/netns",
+ .description =
+ "Zebra tried to verify that the run directory for Linux network namespaces existed, but this test failed.",
+ .suggestion =
+ "Ensure that Zebra has the proper privileges to access this directory.",
+ },
+ {
+ .code = EC_ZEBRA_CONNECTED_AFI_UNKNOWN,
+ .title =
+ "Zebra received unknown address family on interface",
+ .description =
+ "Zebra received a notification of a connected prefix on an interface but did not recognize the address family as IPv4 or IPv6",
+ .suggestion =
+ "This message is informational.",
+ },
+ {
+ .code = EC_ZEBRA_IFACE_SAME_LOCAL_AS_PEER,
+ .title =
+ "Zebra route has same destination address as local interface",
+ .description =
+ "Zebra noticed that a route on an interface has the same destination address as an address on the interface itself, which may cause issues with routing protocols.",
+ .suggestion =
+ "Investigate the source of the route to determine why the destination and interface addresses are the same.",
+ },
+ {
+ .code = EC_ZEBRA_BCAST_ADDR_MISMATCH,
+ .title =
+ "Zebra broadcast address sanity check failed",
+ .description =
+ "Zebra computed the broadcast address for a connected prefix based on the netmask and found that it did not match the broadcast address it received for the prefix on that interface",
+ .suggestion =
+ "Investigate the source of the broadcast address to determine why it does not match the computed address.",
+ },
+ {
+ .code = EC_ZEBRA_REDISTRIBUTE_UNKNOWN_AF,
+ .title =
+ "Zebra encountered unknown address family during redistribution",
+ .description =
+ "During a redistribution operation Zebra encountered an unknown address family.",
+ .suggestion =
+ "This warning can be ignored; the redistribution operation will skip the unknown address family.",
+ },
+ {
+ .code = EC_ZEBRA_ADVERTISING_UNUSABLE_ADDR,
+ .title =
+ "Zebra advertising unusable interface address",
+ .description =
+ "Zebra is advertising an address on an interface that is not yet fully installed on the interface.",
+ .suggestion =
+ "This message is informational. The address should show up on the interface shortly after advertisement.",
+ },
+ {
+ .code = EC_ZEBRA_RA_PARAM_MISMATCH,
+ .title =
+ "Zebra received route advertisement with parameter mismatch",
+ .description =
+ "Zebra received a router advertisement, but one of the non-critical parameters (AdvCurHopLimit, AdvManagedFlag, AdvOtherConfigFlag, AdvReachableTime or AdvRetransTimer) does not match Zebra's local settings.",
+ .suggestion =
+ "This message is informational; the route advertisement will be processed as normal. If issues arise due to the parameter mismatch, check Zebra's router advertisement configuration.",
+ },
+ {
+ .code = EC_ZEBRA_RTM_VERSION_MISMATCH,
+ .title =
+ "Zebra received kernel message with uknown version",
+ .description =
+ "Zebra received a message from the kernel with a message version that does not match Zebra's internal version. Depending on version compatibility, this may cause issues sending and receiving messages to the kernel.",
+ .suggestion =
+ "If issues arise, check if there is a version of FRR available for your kernel version.",
+ },
+ {
+ .code = EC_ZEBRA_RTM_NO_GATEWAY,
+ .title =
+ "Zebra could not determine proper gateway for kernel route",
+ .description =
+ "Zebra attempted to install a route into the kernel, but noticed it had no gateway and no interface with a gateway could be located.",
+ .suggestion =
+ "Check configuration values for correctness.",
+ },
+ {
+ .code = EC_ZEBRA_MAX_LABELS_PUSH,
+ .title =
+ "Zebra exceeded maximum LSP labels for a single rtmsg",
+ .description =
+ "Zebra attempted to push more than one label into the kernel; the maximum on OpenBSD is 1 label.",
+ .suggestion =
+ "This message is informational.",
+ },
+ {
+ .code = EC_ZEBRA_STICKY_MAC_ALREADY_LEARNT,
+ .title =
+ "EVPN MAC already learnt as remote sticky MAC",
+ .description =
+ "Zebra tried to handle a local MAC addition but noticed that it had already learnt the MAC from a remote peer.",
+ .suggestion =
+ "Check configuration values for correctness.",
+ },
+ {
+ .code = EC_ZEBRA_UNSUPPORTED_V6_SRCDEST,
+ .title =
+ "Kernel does not support IPv6 sourcedest routes",
+ .description =
+ "Zebra attempted to install a sourcedest route into the kernel, but IPv6 sourcedest routes are not supported on the current kernel.",
+ .suggestion =
+ "Do not use v6 sourcedest routes, or upgrade your kernel.",
+ },
+ {
+ .code = EC_ZEBRA_DUP_MAC_DETECTED,
+ .title =
+ "EVPN MAC is detected duplicate",
+ .description =
+ "Zebra has hit duplicate address detection threshold which means host MAC is moving.",
+ .suggestion =
+ "Check network topology to detect duplicate host MAC for correctness.",
+ },
+ {
+ .code = EC_ZEBRA_DUP_IP_INHERIT_DETECTED,
+ .title =
+ "EVPN IP is detected duplicate by MAC",
+ .description =
+ "Zebra has hit duplicate address detection threshold which means MAC-IP pair is moving.",
+ .suggestion =
+ "Check network topology to detect duplicate host MAC for correctness.",
+ },
+ {
+ .code = EC_ZEBRA_DUP_IP_DETECTED,
+ .title =
+ "EVPN IP is detected duplicate",
+ .description =
+ "Zebra has hit duplicate address detection threshold which means host IP is moving.",
+ .suggestion =
+ "Check network topology to detect duplicate host IP for correctness.",
+ },
{
.code = END_FERR,
}