The voltage range remains the same, but the limits are shifted by +0.025V.
This change is provided on DA9052:MEM, DA9053:MEM and DA9053:PERI
and is a voltage difference of 0.025V, compared to those measured before
this fix is applied. The patch has the effect of decreasing *all* measured
voltages on those BUCKs when compared against the previously measured
values for the same software voltage request.
For example, with this fix applied for DA9052:MEM, DA9053:MEM and
DA9053:PERI, the following is true.
Because the previous software defined slot 0 as being 0.925V, if a request
for 0.950V was previously sent, the slot 1 voltage would have been used.
This would have corresponded to an actual measured voltage of 0.975V. But,
with this patch fix, and with slot 0 properly aligned to 0.950V, if a
voltage of 0.950V is requested by software, a measured value of 0.950V will
be provided.