ALSA: usb: Add quirk for 192KHz recording on E-Mu devices
When recording at 176.2KHz or 192Khz, the device adds a 32-bit length
header to the capture packets, which obviously needs to be ignored for
recording to work properly.
Also, the last byte of the length header being interpreted as L0 of
the first sample caused spikes every 0.5ms, resulting in a loud 16KHz
tone (about the highest 'B' on a piano) being present throughout
captures.
Tested at all sample rates on an E-Mu 0404USB, and tested for
regressions on a generic USB headset.