Btrfs: fix fsync when extend references are added to an inode
If we added an extended reference to an inode and fsync'ed it, the log
replay code would make our inode have an incorrect link count, which
was lower then the expected/correct count.
This resulted in stale directory index entries after deleting some of
the hard links, and any access to the dangling directory entries resulted
in -ESTALE errors because the entries pointed to inode items that don't
exist anymore.
This is easy to reproduce with the test case I made for xfstests, and
the bulk of that test is:
# Create a test file with 3001 hard links. This number is large enough to
# make btrfs start using extrefs at some point even if the fs has the maximum
# possible leaf/node size (64Kb).
echo "hello world" > $SCRATCH_MNT/foo
for i in `seq 1 3000`; do
ln $SCRATCH_MNT/foo $SCRATCH_MNT/foo_link_`printf "%04d" $i`
done
# Make sure all metadata and data are durably persisted.
sync
# Add one more link to the inode that ends up being a btrfs extref and fsync
# the inode.
ln $SCRATCH_MNT/foo $SCRATCH_MNT/foo_link_3001
$XFS_IO_PROG -c "fsync" $SCRATCH_MNT/foo
# Simulate a crash/power loss. This makes sure the next mount
# will see an fsync log and will replay that log.
# Now after the fsync log replay btrfs left our inode with a wrong link count N,
# which was smaller than the correct link count M (N < M).
# So after removing N hard links, the remaining M - N directory entries were
# still visible to user space but it was impossible to do anything with them
# because they pointed to an inode that didn't exist anymore. This resulted in
# stale file handle errors (-ESTALE) when accessing those dentries for example.
#
# So remove all hard links except the first one and then attempt to read the
# file, to verify we don't get an -ESTALE error when accessing the inodel
#
# The btrfs fsck tool also detected the incorrect inode link count and it
# reported an error message like the following:
#
# root 5 inode 257 errors 2001, no inode item, link count wrong
# unresolved ref dir 256 index 2978 namelen 13 name foo_link_2976 filetype 1 errors 4, no inode ref
#
# The fstests framework automatically calls fsck after a test is run, so we
# don't need to call fsck explicitly here.
So make sure an fsync always flushes the delayed inode item, so that the
fsync log contains it (needed in order to trigger the link count fixup
code) and fix the extref counting function, which always return -ENOENT
to its caller (and made it assume there were always 0 extrefs).
This issue has been present since the introduction of the extrefs feature
(2012).
A test case for xfstests follows soon.
Signed-off-by: Filipe Manana <fdmanana@suse.com> Signed-off-by: Chris Mason <clm@fb.com>