nilfs2: fix issue with counting number of bio requests for BIO_EOPNOTSUPP error detection
Fix the issue with improper counting number of flying bio requests for
BIO_EOPNOTSUPP error detection case.
The sb_nbio must be incremented exactly the same number of times as
complete() function was called (or will be called) because
nilfs_segbuf_wait() will call wail_for_completion() for the number of
times set to sb_nbio:
do {
wait_for_completion(&segbuf->sb_bio_event);
} while (--segbuf->sb_nbio > 0);
Two functions complete() and wait_for_completion() must be called the
same number of times for the same sb_bio_event. Otherwise,