]> git.proxmox.com Git - mirror_ubuntu-kernels.git/commit
cpumask: fix incorrect cpumask scanning result checks
authorLinus Torvalds <torvalds@linux-foundation.org>
Mon, 6 Mar 2023 20:15:13 +0000 (12:15 -0800)
committerLinus Torvalds <torvalds@linux-foundation.org>
Mon, 6 Mar 2023 20:15:13 +0000 (12:15 -0800)
commit8ca09d5fa3549d142c2080a72a4c70ce389163cd
treed6b82f95f9a1410debe67cd465d0fac7efb6d598
parent80c16b2b121fbc3380dbffa9bab7559acbaaa2ed
cpumask: fix incorrect cpumask scanning result checks

It turns out that commit 596ff4a09b89 ("cpumask: re-introduce
constant-sized cpumask optimizations") exposed a number of cases of
drivers not checking the result of "cpumask_next()" and friends
correctly.

The documented correct check for "no more cpus in the cpumask" is to
check for the result being equal or larger than the number of possible
CPU ids, exactly _because_ we've always done those constant-sized
cpumask scans using a widened type before.  So the return value of a
cpumask scan should be checked with

if (cpu >= nr_cpu_ids)
...

because the cpumask scan did not necessarily stop exactly *at* that
maximum CPU id.

But a few cases ended up instead using checks like

if (cpu == nr_cpumask_bits)
...

which used that internal "widened" number of bits.  And that used to
work pretty much by accident (ok, in this case "by accident" is simply
because it matched the historical internal implementation of the cpumask
scanning, so it was more of a "intentionally using implementation
details rather than an accident").

But the extended constant-sized optimizations then did that internal
implementation differently, and now that code that did things wrong but
matched the old implementation no longer worked at all.

Which then causes subsequent odd problems due to using what ends up
being an invalid CPU ID.

Most of these cases require either unusual hardware or special uses to
hit, but the random.c one triggers quite easily.

All you really need is to have a sufficiently small CONFIG_NR_CPUS value
for the bit scanning optimization to be triggered, but not enough CPUs
to then actually fill that widened cpumask.  At that point, the cpumask
scanning will return the NR_CPUS constant, which is _not_ the same as
nr_cpumask_bits.

This just does the mindless fix with

   sed -i 's/== nr_cpumask_bits/>= nr_cpu_ids/'

to fix the incorrect uses.

The ones in the SCSI lpfc driver in particular could probably be fixed
more cleanly by just removing that repeated pattern entirely, but I am
not emptionally invested enough in that driver to care.

Reported-and-tested-by: Guenter Roeck <linux@roeck-us.net>
Link: https://lore.kernel.org/lkml/481b19b5-83a0-4793-b4fd-194ad7b978c3@roeck-us.net/
Reported-and-tested-by: Geert Uytterhoeven <geert+renesas@glider.be>
Link: https://lore.kernel.org/lkml/CAMuHMdUKo_Sf7TjKzcNDa8Ve+6QrK+P8nSQrSQ=6LTRmcBKNww@mail.gmail.com/
Reported-by: Vernon Yang <vernon2gm@gmail.com>
Link: https://lore.kernel.org/lkml/20230306160651.2016767-1-vernon2gm@gmail.com/
Cc: Yury Norov <yury.norov@gmail.com>
Cc: Jason A. Donenfeld <Jason@zx2c4.com>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
arch/powerpc/xmon/xmon.c
drivers/char/random.c
drivers/net/wireguard/queueing.h
drivers/scsi/lpfc/lpfc_init.c