mt76: mt76x02: reduce false positives in ED/CCA tx blocking
Full tx blocking (as opposed to CCA blocking) should only happen if there
is a continuous non-802.11 signal above the energy detect threshold.
Unfortunately the ED/CCA counter can't detect that, as it also counts 802.11
signals as busy.
Similar to the vendor code, implement a learning mode that waits until the AGC
gain has already been adjusted to the lowest value (due to false CCA events),
and the number of false CCA events still remains high, and the blocking
threshold is exceeded for more than 5 seconds.