__ieee80211_scan_completed is called from a worker. This
means that the following flow is possible.
* driver calls ieee80211_scan_completed
* mac80211 cancels the scan (that is already complete)
* __ieee80211_scan_completed runs
When scan_work will finally run, it will see that the scan
hasn't been aborted and might even trigger another scan on
another band. This leads to a situation where cfg80211's
scan is not done and no further scan can be issued.
Fix this by setting a new flag when a HW scan is being
cancelled so that no other scan will be triggered.
Cc: stable@vger.kernel.org Signed-off-by: Emmanuel Grumbach <emmanuel.grumbach@intel.com> Signed-off-by: Johannes Berg <johannes.berg@intel.com>