iio: adc: ad_sigma_delta: Fix IRQ issue by setting IRQ_DISABLE_UNLAZY flag
BugLink: https://bugs.launchpad.net/bugs/2029808
commit
626d312028bec44209d0ecd5beaa9b1aa8945f7d upstream.
The Sigma-Delta ADCs supported by this driver can use SDO as an interrupt
line to indicate the completion of a conversion. However, some devices
cannot properly detect the completion of a conversion by an interrupt.
This is for the reason mentioned in the following commit.
commit
e9849777d0e2 ("genirq: Add flag to force mask in
disable_irq[_nosync]()")
A read operation is performed by an extra interrupt before the completion
of a conversion. At this time, the value read from the ADC data register
is the same as the previous conversion result. This patch fixes the issue
by setting IRQ_DISABLE_UNLAZY flag.
Fixes: 0c6ef985a1fd ("iio: adc: ad7791: fix IRQ flags")
Fixes: 1a913270e57a ("iio: adc: ad7793: Fix IRQ flag")
Fixes: e081102f3077 ("iio: adc: ad7780: Fix IRQ flag")
Fixes: 89a86da5cb8e ("iio: adc: ad7192: Add IRQ flag")
Fixes: 79ef91493f54 ("iio: adc: ad7124: Set IRQ type to falling")
Signed-off-by: Masahiro Honda <honda@mechatrax.com>
Link: https://lore.kernel.org/r/20230518110816.248-1-honda@mechatrax.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Signed-off-by: Kamal Mostafa <kamal@canonical.com>
Signed-off-by: Stefan Bader <stefan.bader@canonical.com>