Added default output data rate setting to platform data.
If default rate is 0, reset default value is used.
Added control for duration via platform data.
Added possibility to configure interrupts to trig on
both rising and falling edge. The lis3 WU unit can be
configured quite many ways and with some configurations it
is quite handy to get coordinate refresh when some
event trigs and when it reason goes away.
Signed-off-by: Samu Onkalo <samu.p.onkalo@nokia.com> Acked-by: Jonathan Cameron <jic23@cam.ac.uk> Acked-by: Eric Piel <eric.piel@tremplin-utc.net> Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>