]> git.proxmox.com Git - mirror_ubuntu-disco-kernel.git/commit
md/raid5: introduce configuration option rmw_level
authorMarkus Stockhausen <stockhausen@collogia.de>
Mon, 15 Dec 2014 01:57:05 +0000 (12:57 +1100)
committerNeilBrown <neilb@suse.de>
Tue, 21 Apr 2015 22:00:42 +0000 (08:00 +1000)
commitd06f191f8ecaef4d524e765fdb455f96392fbd42
tree3e83449b9fb3c910a7a6d65a776304dd158e18c4
parent584acdd49cd2472ca0f5a06adbe979db82d0b4af
md/raid5: introduce configuration option rmw_level

Depending on the available coding we allow optimized rmw logic for write
operations. To support easier testing this patch allows manual control
of the rmw/rcw descision through the interface /sys/block/mdX/md/rmw_level.

The configuration can handle three levels of control.

rmw_level=0: Disable rmw for all RAID types. Hardware assisted P/Q
calculation has no implementation path yet to factor in/out chunks of
a syndrome. Enforcing this level can be benefical for slow CPUs with
hardware syndrome support and fast SSDs.

rmw_level=1: Estimate rmw IOs and rcw IOs. Execute rmw only if we will
save IOs. This equals the "old" unpatched behaviour and will be the
default.

rmw_level=2: Execute rmw even if calculated IOs for rmw and rcw are
equal. We might have higher CPU consumption because of calculating the
parity twice but it can be benefical otherwise. E.g. RAID4 with fast
dedicated parity disk/SSD. The option is implemented just to be
forward-looking and will ONLY work with this patch!

Signed-off-by: Markus Stockhausen <stockhausen@collogia.de>
Signed-off-by: NeilBrown <neilb@suse.de>
drivers/md/raid5.c
drivers/md/raid5.h