Rename this function so it has namespace associated with the driver.
The cmd->scan_begin_src is always TRIG_FOLLOW and the only valid
cmd->convert_src is TRIG_TIMER or TRIG_EXT so pcl818_ai_cmd_mode()
is always called with a 'mode' of 1 or 3. The 'mode' actually indicates
the trigger source.
Absorb pcl818_ai_cmd_mode() into this function and simplify the code.
This also removes the need for a forward declaration.
Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com> Reviewed-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>