can: sja1000: of: add compatibility with Technologic Systems version
Technologic Systems provides an IP compatible with the SJA1000,
instantiated in an FPGA. Because of some bus widths issue, access to
registers is made through a "window" that works like this:
base + 0x0: address to read/write
base + 0x2: 8-bit register value
This commit adds a new compatible device, "technologic,sja1000", with
read and write functions using the window mechanism.
Signed-off-by: Damien Riegel <damien.riegel@savoirfairelinux.com> Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>