* Locally, the range is stored as a table index.
*/
-static const int stk8ba50_scale_table[][2] = {
+static const struct {
+ u8 reg_val;
+ u32 scale_val;
+} stk8ba50_scale_table[] = {
{3, 38400}, {5, 76700}, {8, 153400}, {12, 306900}
};
return IIO_VAL_INT;
case IIO_CHAN_INFO_SCALE:
*val = 0;
- *val2 = stk8ba50_scale_table[data->range][1];
+ *val2 = stk8ba50_scale_table[data->range].scale_val;
return IIO_VAL_INT_PLUS_MICRO;
}
return -EINVAL;
for (i = 0; i < ARRAY_SIZE(stk8ba50_scale_table); i++)
- if (val2 == stk8ba50_scale_table[i][1]) {
+ if (val2 == stk8ba50_scale_table[i].scale_val) {
index = i;
break;
}
ret = i2c_smbus_write_byte_data(data->client,
STK8BA50_REG_RANGE,
- stk8ba50_scale_table[index][0]);
+ stk8ba50_scale_table[index].reg_val);
if (ret < 0)
dev_err(&data->client->dev,
"failed to set measurement range\n");