]> git.proxmox.com Git - mirror_ubuntu-eoan-kernel.git/commitdiff
ALSA: oxygen: fix analog capture on Claro halo cards
authorErik J. Staab <ejs@insightbb.com>
Wed, 22 Sep 2010 09:07:41 +0000 (11:07 +0200)
committerTakashi Iwai <tiwai@suse.de>
Wed, 22 Sep 2010 08:04:08 +0000 (10:04 +0200)
On the HT-Omega Claro halo card, the ADC data must be captured from the
second I2S input.  Using the default first input, which isn't connected
to anything, would result in silence.

Signed-off-by: Erik J. Staab <ejs@insightbb.com>
Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Cc: <stable@kernel.org>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
sound/pci/oxygen/oxygen.c

index 289cb4dacfc79ec012b6efb174054efaa0afe855..6c0a11adb2a84511b83b23b69d5efce9fb2085c6 100644 (file)
@@ -543,6 +543,10 @@ static int __devinit get_oxygen_model(struct oxygen *chip,
                chip->model.suspend = claro_suspend;
                chip->model.resume = claro_resume;
                chip->model.set_adc_params = set_ak5385_params;
+               chip->model.device_config = PLAYBACK_0_TO_I2S |
+                                           PLAYBACK_1_TO_SPDIF |
+                                           CAPTURE_0_FROM_I2S_2 |
+                                           CAPTURE_1_FROM_SPDIF;
                break;
        }
        if (id->driver_data == MODEL_MERIDIAN ||