[Why]
In certain instances, there was a reliance on pipe indexing being accurate. However, this
assumption fails with harvesting of pipes 1 or 2, which can occur in production B6 parts.
HW hang would occur as a result.
[How]
Use hubp index for mpcc, and do mpc_init for all theoretical pipes (including disabled ones).
Signed-off-by: Noah Abradjian <noah.abradjian@amd.com>
Reviewed-by: Yongqiang Sun <yongqiang.sun@amd.com>
Acked-by: Rodrigo Siqueira <Rodrigo.Siqueira@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
}
}
- for (i = 0; i < dc->res_pool->pipe_count; i++) {
+ /* num_opp will be equal to number of mpcc */
+ for (i = 0; i < dc->res_pool->res_cap->num_opp; i++) {
struct pipe_ctx *pipe_ctx = &context->res_ctx.pipe_ctx[i];
/* Cannot reset the MPC mux if seamless boot */
|| plane_state->update_flags.bits.global_alpha_change
|| plane_state->update_flags.bits.per_pixel_alpha_change) {
// MPCC inst is equal to pipe index in practice
- int mpcc_inst = pipe_ctx->pipe_idx;
+ int mpcc_inst = hubp->inst;
int opp_inst;
int opp_count = dc->res_pool->pipe_count;