According to figure 39 in PEB3086 data sheet, version 1.4 this indication
replaces DR when layer 1 transition source state is F6.
This fixes mISDN layer 1 getting stuck in F6 state in TE mode on
Dialogic Diva 2.02 card (and possibly others) when NT deactivates it.
Signed-off-by: Maciej S. Szmigiero <mail@maciej.szmigiero.name>
Acked-by: Karsten Keil <keil@b1-systems.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
#define ISAC_IND_SD 0x2
#define ISAC_IND_DIS 0x3
#define ISAC_IND_RSY 0x4
+#define ISAC_IND_DR6 0x5
#define ISAC_IND_EI 0x6
#define ISAC_IND_PU 0x7
#define ISAC_IND_ARD 0x8
l1_event(dch->l1, HW_DEACT_CNF);
break;
case ISAC_IND_DR:
+ case ISAC_IND_DR6:
dch->state = 3;
l1_event(dch->l1, HW_DEACT_IND);
break;
spin_lock_irqsave(isac->hwlock, flags);
if ((isac->state == ISAC_IND_EI) ||
(isac->state == ISAC_IND_DR) ||
+ (isac->state == ISAC_IND_DR6) ||
(isac->state == ISAC_IND_RS))
ph_command(isac, ISAC_CMD_TIM);
else