Observed Auto mode in the HBA side while doing manual D-Port test on the
switch side. Mode is not passed to BFA from firmware when the test is
triggered by switch side. BFA just blindly using Auto mode.
Signed-off-by: Vijaya Mohan Guvva <vmohan@brocade.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
dport->rp_pwwn = msg->info.teststart.pwwn;
dport->rp_nwwn = msg->info.teststart.nwwn;
dport->lpcnt = cpu_to_be32(msg->info.teststart.numfrm);
- bfa_dport_result_start(dport, BFA_DPORT_OPMODE_AUTO);
+ bfa_dport_result_start(dport, msg->info.teststart.mode);
break;
case BFI_DPORT_SCN_SUBTESTSTART:
wwn_t pwwn; /* switch port wwn. 8 bytes */
wwn_t nwwn; /* switch node wwn. 8 bytes */
u8 type; /* bfa_diag_dport_test_type_e */
- u8 rsvd[3];
+ u8 mode; /* bfa_diag_dport_test_opmode */
+ u8 rsvd[2];
u32 numfrm; /* from switch uint in 1M */
};