]> git.proxmox.com Git - mirror_ubuntu-bionic-kernel.git/commitdiff
thermal: exynos: Reading temperature makes sense only when TMU is turned on
authorMarek Szyprowski <m.szyprowski@samsung.com>
Mon, 16 Apr 2018 10:11:52 +0000 (12:11 +0200)
committerStefan Bader <stefan.bader@canonical.com>
Tue, 14 Aug 2018 10:26:10 +0000 (12:26 +0200)
BugLink: http://bugs.launchpad.net/bugs/1780499
commit 88fc6f73fddf64eb507b04f7b2bd01d7291db514 upstream.

When thermal sensor is not yet enabled, reading temperature might return
random value. This might even result in stopping system booting when such
temperature is higher than the critical value. Fix this by checking if TMU
has been actually enabled before reading the temperature.

This change fixes booting of Exynos4210-based board with TMU enabled (for
example Samsung Trats board), which was broken since v4.4 kernel release.

Signed-off-by: Marek Szyprowski <m.szyprowski@samsung.com>
Fixes: 9e4249b40340 ("thermal: exynos: Fix first temperature read after registering sensor")
CC: stable@vger.kernel.org # v4.6+
Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Signed-off-by: Kamal Mostafa <kamal@canonical.com>
Signed-off-by: Khalid Elmously <khalid.elmously@canonical.com>
drivers/thermal/samsung/exynos_tmu.c

index ed805c7c5ace3a121be27359bb4d08ee42634a4d..986cbd01aaaa751cc31923823f4d9babd3aa9ec7 100644 (file)
  * @regulator: pointer to the TMU regulator structure.
  * @reg_conf: pointer to structure to register with core thermal.
  * @ntrip: number of supported trip points.
+ * @enabled: current status of TMU device
  * @tmu_initialize: SoC specific TMU initialization method
  * @tmu_control: SoC specific TMU control method
  * @tmu_read: SoC specific TMU temperature read method
@@ -205,6 +206,7 @@ struct exynos_tmu_data {
        struct regulator *regulator;
        struct thermal_zone_device *tzd;
        unsigned int ntrip;
+       bool enabled;
 
        int (*tmu_initialize)(struct platform_device *pdev);
        void (*tmu_control)(struct platform_device *pdev, bool on);
@@ -398,6 +400,7 @@ static void exynos_tmu_control(struct platform_device *pdev, bool on)
        mutex_lock(&data->lock);
        clk_enable(data->clk);
        data->tmu_control(pdev, on);
+       data->enabled = on;
        clk_disable(data->clk);
        mutex_unlock(&data->lock);
 }
@@ -890,7 +893,7 @@ static int exynos_get_temp(void *p, int *temp)
 {
        struct exynos_tmu_data *data = p;
 
-       if (!data || !data->tmu_read)
+       if (!data || !data->tmu_read || !data->enabled)
                return -EINVAL;
 
        mutex_lock(&data->lock);