]> git.proxmox.com Git - mirror_ubuntu-kernels.git/commitdiff
Bluetooth: use the proper scan params when conn is pending
authorAlain Michaud <alainm@chromium.org>
Fri, 31 Jul 2020 01:05:34 +0000 (01:05 +0000)
committerMarcel Holtmann <marcel@holtmann.org>
Fri, 31 Jul 2020 06:28:23 +0000 (08:28 +0200)
When an LE connection is requested and an RPA update is needed via
hci_connect_le_scan, the default scanning parameters are used rather
than the connect parameters.  This leads to significant delays in the
connection establishment process when using lower duty cycle scanning
parameters.

The patch simply looks at the pended connection list when trying to
determine which scanning parameters should be used.

Before:
< HCI Command: LE Set Extended Scan Parameters (0x08|0x0041) plen 8
                            #378 [hci0] 1659.247156
        Own address type: Public (0x00)
        Filter policy: Ignore not in white list (0x01)
        PHYs: 0x01
        Entry 0: LE 1M
          Type: Passive (0x00)
          Interval: 367.500 msec (0x024c)
          Window: 37.500 msec (0x003c)

After:
< HCI Command: LE Set Extended Scan Parameters (0x08|0x0041) plen 8
                               #39 [hci0] 7.422109
        Own address type: Public (0x00)
        Filter policy: Ignore not in white list (0x01)
        PHYs: 0x01
        Entry 0: LE 1M
          Type: Passive (0x00)
          Interval: 60.000 msec (0x0060)
          Window: 60.000 msec (0x0060)

Signed-off-by: Alain Michaud <alainm@chromium.org>
Reviewed-by: Abhishek Pandit-Subedi <abhishekpandit@chromium.org>
Reviewed-by: Yu Liu <yudiliu@google.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
net/bluetooth/hci_request.c

index 435400a43a78834896e784f0ea95725feb2ab002..e0269192f2e5364fdddc0d093d42901a0bf3eafc 100644 (file)
@@ -953,6 +953,27 @@ static void hci_req_start_scan(struct hci_request *req, u8 type, u16 interval,
        }
 }
 
+/* Returns true if an le connection is in the scanning state */
+static inline bool hci_is_le_conn_scanning(struct hci_dev *hdev)
+{
+       struct hci_conn_hash *h = &hdev->conn_hash;
+       struct hci_conn  *c;
+
+       rcu_read_lock();
+
+       list_for_each_entry_rcu(c, &h->list, list) {
+               if (c->type == LE_LINK && c->state == BT_CONNECT &&
+                   test_bit(HCI_CONN_SCANNING, &c->flags)) {
+                       rcu_read_unlock();
+                       return true;
+               }
+       }
+
+       rcu_read_unlock();
+
+       return false;
+}
+
 /* Ensure to call hci_req_add_le_scan_disable() first to disable the
  * controller based address resolution to be able to reconfigure
  * resolving list.
@@ -1003,6 +1024,9 @@ void hci_req_add_le_passive_scan(struct hci_request *req)
        if (hdev->suspended) {
                window = hdev->le_scan_window_suspend;
                interval = hdev->le_scan_int_suspend;
+       } else if (hci_is_le_conn_scanning(hdev)) {
+               window = hdev->le_scan_window_connect;
+               interval = hdev->le_scan_int_connect;
        } else {
                window = hdev->le_scan_window;
                interval = hdev->le_scan_interval;