Fix the MCP2515 SPI CAN controller interrupt polarity which according
to its datasheet defaults to low-active aka falling edge.
Signed-off-by: Marcel Ziswiler <marcel.ziswiler@toradex.com>
Signed-off-by: Thierry Reding <treding@nvidia.com>
reg = <1>;
clocks = <&clk16m>;
interrupt-parent = <&gpio>;
- interrupts = <TEGRA_GPIO(W, 3) IRQ_TYPE_EDGE_RISING>;
+ interrupts = <TEGRA_GPIO(W, 3) IRQ_TYPE_EDGE_FALLING>;
spi-max-frequency = <10000000>;
};
};
reg = <0>;
clocks = <&clk16m>;
interrupt-parent = <&gpio>;
- interrupts = <TEGRA_GPIO(W, 2) IRQ_TYPE_EDGE_RISING>;
+ interrupts = <TEGRA_GPIO(W, 2) IRQ_TYPE_EDGE_FALLING>;
spi-max-frequency = <10000000>;
};
};