Patch 5879/1: ep93xx: define magic numbers for pll1 and pll2 broke
the ep93xx build due to one missing rename of EP93XX_SYSCON_CLOCK_SET2.
The correct name should be EP93XX_SYSCON_CLKSET2.
Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Acked-by: Ryan Mallon <ryan@bluewatersys.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
ep93xx_dma_clock_init();
/* Determine the bootloader configured pll2 rate */
- value = __raw_readl(EP93XX_SYSCON_CLOCK_SET2);
+ value = __raw_readl(EP93XX_SYSCON_CLKSET2);
if (!(value & EP93XX_SYSCON_CLKSET2_NBYP2))
clk_pll2.rate = clk_xtali.rate;
else if (value & EP93XX_SYSCON_CLKSET2_PLL2_EN)