BugLink: http://bugs.launchpad.net/bugs/1673118
commit
1c9c858e2ff8ae8024a3d75d2ed080063af43754 upstream.
The MKS Instruments SCOM-0800 and SCOM-0801 cards (originally by Tenta
Technologies) are 3U CompactPCI serial cards with 4 and 8 serial ports,
respectively. The first 4 ports are implemented by an OX16PCI954 chip,
and the second 4 ports are implemented by an OX16C954 chip on a local
bus, bridged by the second PCI function of the OX16PCI954. The ports
are jumper-selectable as RS-232 and RS-422/485, and the UARTs use a
non-standard oscillator frequency of 20 MHz (base_baud =
1250000).
Signed-off-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Signed-off-by: Tim Gardner <tim.gardner@canonical.com>
pbn_b0_4_1152000_200,
pbn_b0_8_1152000_200,
+ pbn_b0_4_1250000,
+
pbn_b0_2_1843200,
pbn_b0_4_1843200,
.uart_offset = 0x200,
},
+ [pbn_b0_4_1250000] = {
+ .flags = FL_BASE0,
+ .num_ports = 4,
+ .base_baud = 1250000,
+ .uart_offset = 8,
+ },
+
[pbn_b0_2_1843200] = {
.flags = FL_BASE0,
.num_ports = 2,
{ PCI_DEVICE(0x1c29, 0x1108), .driver_data = pbn_fintek_8 },
{ PCI_DEVICE(0x1c29, 0x1112), .driver_data = pbn_fintek_12 },
+ /* MKS Tenta SCOM-080x serial cards */
+ { PCI_DEVICE(0x1601, 0x0800), .driver_data = pbn_b0_4_1250000 },
+ { PCI_DEVICE(0x1601, 0xa801), .driver_data = pbn_b0_4_1250000 },
+
/*
* These entries match devices with class COMMUNICATION_SERIAL,
* COMMUNICATION_MODEM or COMMUNICATION_MULTISERIAL