discharging (i.e. powering a load), etc.). This corresponds to
BATTERY_STATUS_* values, as defined in battery.h.
+CHARGE_TYPE - batteries can typically charge at different rates.
+This defines trickle and fast charges. For batteries that
+are already charged or discharging, 'n/a' can be displayed (or
+'unknown', if the status is not known).
+
HEALTH - represents health of the battery, values corresponds to
POWER_SUPPLY_HEALTH_*, defined in battery.h.
if (ret)
return ret;
break;
+ case POWER_SUPPLY_PROP_CHARGE_TYPE:
+ if (ec_byte & BAT_STAT_TRICKLE)
+ val->intval = POWER_SUPPLY_CHARGE_TYPE_TRICKLE;
+ else if (ec_byte & BAT_STAT_CHARGING)
+ val->intval = POWER_SUPPLY_CHARGE_TYPE_FAST;
+ else
+ val->intval = POWER_SUPPLY_CHARGE_TYPE_NONE;
+ break;
case POWER_SUPPLY_PROP_PRESENT:
val->intval = !!(ec_byte & (BAT_STAT_PRESENT |
BAT_STAT_TRICKLE));
static enum power_supply_property olpc_bat_props[] = {
POWER_SUPPLY_PROP_STATUS,
+ POWER_SUPPLY_PROP_CHARGE_TYPE,
POWER_SUPPLY_PROP_PRESENT,
POWER_SUPPLY_PROP_HEALTH,
POWER_SUPPLY_PROP_TECHNOLOGY,
static char *status_text[] = {
"Unknown", "Charging", "Discharging", "Not charging", "Full"
};
+ static char *charge_type[] = {
+ "Unknown", "N/A", "Trickle", "Fast"
+ };
static char *health_text[] = {
"Unknown", "Good", "Overheat", "Dead", "Over voltage",
"Unspecified failure", "Cold",
if (off == POWER_SUPPLY_PROP_STATUS)
return sprintf(buf, "%s\n", status_text[value.intval]);
+ else if (off == POWER_SUPPLY_PROP_CHARGE_TYPE)
+ return sprintf(buf, "%s\n", charge_type[value.intval]);
else if (off == POWER_SUPPLY_PROP_HEALTH)
return sprintf(buf, "%s\n", health_text[value.intval]);
else if (off == POWER_SUPPLY_PROP_TECHNOLOGY)
static struct device_attribute power_supply_attrs[] = {
/* Properties of type `int' */
POWER_SUPPLY_ATTR(status),
+ POWER_SUPPLY_ATTR(charge_type),
POWER_SUPPLY_ATTR(health),
POWER_SUPPLY_ATTR(present),
POWER_SUPPLY_ATTR(online),
POWER_SUPPLY_STATUS_FULL,
};
+enum {
+ POWER_SUPPLY_CHARGE_TYPE_UNKNOWN = 0,
+ POWER_SUPPLY_CHARGE_TYPE_NONE,
+ POWER_SUPPLY_CHARGE_TYPE_TRICKLE,
+ POWER_SUPPLY_CHARGE_TYPE_FAST,
+};
+
enum {
POWER_SUPPLY_HEALTH_UNKNOWN = 0,
POWER_SUPPLY_HEALTH_GOOD,
enum power_supply_property {
/* Properties of type `int' */
POWER_SUPPLY_PROP_STATUS = 0,
+ POWER_SUPPLY_PROP_CHARGE_TYPE,
POWER_SUPPLY_PROP_HEALTH,
POWER_SUPPLY_PROP_PRESENT,
POWER_SUPPLY_PROP_ONLINE,