]> git.proxmox.com Git - mirror_ubuntu-eoan-kernel.git/commit
md/raid1: read balance chooses idlest disk for SSD
authorShaohua Li <shli@kernel.org>
Tue, 31 Jul 2012 00:03:53 +0000 (10:03 +1000)
committerNeilBrown <neilb@suse.de>
Tue, 31 Jul 2012 00:03:53 +0000 (10:03 +1000)
commit9dedf60313fa4dddfd5b9b226a0ef12a512bf9dc
tree36e8f400d7c858da776bf74f40e0ca71829ecb05
parentbe4d3280b17bc51f23ec6ebb345728f302f80a0c
md/raid1: read balance chooses idlest disk for SSD

SSD hasn't spindle, distance between requests means nothing. And the original
distance based algorithm sometimes can cause severe performance issue for SSD
raid.

Considering two thread groups, one accesses file A, the other access file B.
The first group will access one disk and the second will access the other disk,
because requests are near from one group and far between groups. In this case,
read balance might keep one disk very busy but the other relative idle.  For
SSD, we should try best to distribute requests to as many disks as possible.
There isn't spindle move penality anyway.

With below patch, I can see more than 50% throughput improvement sometimes
depending on workloads.

The only exception is small requests can be merged to a big request which
typically can drive higher throughput for SSD too. Such small requests are
sequential reads. Unlike hard disk, sequential read which can't be merged (for
example direct IO, or read without readahead) can be ignored for SSD. Again
there is no spindle move penality. readahead dispatches small requests and such
requests can be merged.

Last patch can help detect sequential read well, at least if concurrent read
number isn't greater than raid disk number. In that case, distance based
algorithm doesn't work well too.

V2: For hard disk and SSD mixed raid, doesn't use distance based algorithm for
random IO too. This makes the algorithm generic for raid with SSD.

Signed-off-by: Shaohua Li <shli@fusionio.com>
Signed-off-by: NeilBrown <neilb@suse.de>
drivers/md/raid1.c