]> git.proxmox.com Git - mirror_iproute2.git/blame - doc/api-ip6-flowlabels.tex
Merge branch 'master' into net-next
[mirror_iproute2.git] / doc / api-ip6-flowlabels.tex
CommitLineData
aba5acdf
SH
1\documentstyle[12pt,twoside]{article}
2\def\TITLE{IPv6 Flow Labels}
3\input preamble
4\begin{center}
5\Large\bf IPv6 Flow Labels in Linux-2.2.
6\end{center}
7
8
9\begin{center}
10{ \large Alexey~N.~Kuznetsov } \\
11\em Institute for Nuclear Research, Moscow \\
12\verb|kuznet@ms2.inr.ac.ru| \\
13\rm April 11, 1999
14\end{center}
15
16\vspace{5mm}
17
18\tableofcontents
19
20\section{Introduction.}
21
22Every IPv6 packet carries 28 bits of flow information. RFC2460 splits
23these bits to two fields: 8 bits of traffic class (or DS field, if you
24prefer this term) and 20 bits of flow label. Currently there exist
25no well-defined API to manage IPv6 flow information. In this document
26I describe an attempt to design the API for Linux-2.2 IPv6 stack.
27
28\vskip 1mm
29
30The API must solve the following tasks:
31
32\begin{enumerate}
33
34\item To allow user to set traffic class bits.
35
36\item To allow user to read traffic class bits of received packets.
37This feature is not so useful as the first one, however it will be
38necessary f.e.\ to implement ECN [RFC2481] for datagram oriented services
39or to implement receiver side of SRP or another end-to-end protocol
40using traffic class bits.
41
42\item To assign flow labels to packets sent by user.
43
44\item To get flow labels of received packets. I do not know
45any applications of this feature, but it is possible that receiver will
46want to use flow labels to distinguish sub-flows.
47
48\item To allocate flow labels in the way, compliant to RFC2460. Namely:
49
50\begin{itemize}
51\item
52Flow labels must be uniformly distributed (pseudo-)random numbers,
53so that any subset of 20 bits can be used as hash key.
54
55\item
56Flows with coinciding source address and flow label must have identical
57destination address and not-fragmentable extensions headers (i.e.\
58hop by hop options and all the headers up to and including routing header,
59if it is present.)
60
61\begin{NB}
62There is a hole in specs: some hop-by-hop options can be
63defined only on per-packet base (f.e.\ jumbo payload option).
64Essentially, it means that such options cannot present in packets
65with flow labels.
66\end{NB}
67\begin{NB}
68NB notes here and below reflect only my personal opinion,
69they should be read with smile or should not be read at all :-).
70\end{NB}
71
72
73\item
74Flow labels have finite lifetime and source is not allowed to reuse
75flow label for another flow within the maximal lifetime has expired,
76so that intermediate nodes will be able to invalidate flow state before
77the label is taken over by another flow.
78Flow state, including lifetime, is propagated along datagram path
79by some application specific methods
80(f.e.\ in RSVP PATH messages or in some hop-by-hop option).
81
82
83\end{itemize}
84
85\end{enumerate}
86
87\section{Sending/receiving flow information.}
88
89\paragraph{Discussion.}
90\addcontentsline{toc}{subsection}{Discussion}
91It was proposed (Where? I do not remember any explicit statement)
92to solve the first four tasks using
93\verb|sin6_flowinfo| field added to \verb|struct| \verb|sockaddr_in6|
94(see RFC2553).
95
96\begin{NB}
97 This method is difficult to consider as reasonable, because it
98 puts additional overhead to all the services, despite of only
99 very small subset of them (none, to be more exact) really use it.
100 It contradicts both to IETF spirit and the letter. Before RFC2553
101 one justification existed, IPv6 address alignment left 4 byte
102 hole in \verb|sockaddr_in6| in any case. Now it has no justification.
103\end{NB}
104
105We have two problems with this method. The first one is common for all OSes:
106if \verb|recvmsg()| initializes \verb|sin6_flowinfo| to flow info
107of received packet, we loose one very important property of BSD socket API,
108namely, we are not allowed to use received address for reply directly
109and have to mangle it, even if we are not interested in flowinfo subtleties.
110
111\begin{NB}
112 RFC2553 adds new requirement: to clear \verb|sin6_flowinfo|.
113 Certainly, it is not solution but rather attempt to force applications
114 to make unnecessary work. Well, as usually, one mistake in design
115 is followed by attempts to patch the hole and more mistakes...
116\end{NB}
117
118Another problem is Linux specific. Historically Linux IPv6 did not
119initialize \verb|sin6_flowinfo| at all, so that, if kernel does not
120support flow labels, this field is not zero, but a random number.
121Some applications also did not take care about it.
122
123\begin{NB}
124Following RFC2553 such applications can be considered as broken,
125but I still think that they are right: clearing all the address
126before filling known fields is robust but stupid solution.
127Useless wasting CPU cycles and
128memory bandwidth is not a good idea. Such patches are acceptable
129as temporary hacks, but not as standard of the future.
130\end{NB}
131
132
133\paragraph{Implementation.}
134\addcontentsline{toc}{subsection}{Implementation}
135By default Linux IPv6 does not read \verb|sin6_flowinfo| field
136assuming that common applications are not obliged to initialize it
137and are permitted to consider it as pure alignment padding.
138In order to tell kernel that application
139is aware of this field, it is necessary to set socket option
140\verb|IPV6_FLOWINFO_SEND|.
141
142\begin{verbatim}
143 int on = 1;
144 setsockopt(sock, SOL_IPV6, IPV6_FLOWINFO_SEND,
145 (void*)&on, sizeof(on));
146\end{verbatim}
147
148Linux kernel never fills \verb|sin6_flowinfo| field, when passing
149message to user space, though the kernels which support flow labels
150initialize it to zero. If user wants to get received flowinfo, he
151will set option \verb|IPV6_FLOWINFO| and after this he will receive
152flowinfo as ancillary data object of type \verb|IPV6_FLOWINFO|
153(cf.\ RFC2292).
154
155\begin{verbatim}
156 int on = 1;
157 setsockopt(sock, SOL_IPV6, IPV6_FLOWINFO, (void*)&on, sizeof(on));
158\end{verbatim}
159
160Flowinfo received and latched by a connected TCP socket also may be fetched
161with \verb|getsockopt()| \verb|IPV6_PKTOPTIONS| together with
162another optional information.
163
164Besides that, in the spirit of RFC2292 the option \verb|IPV6_FLOWINFO|
165may be used as alternative way to send flowinfo with \verb|sendmsg()| or
166to latch it with \verb|IPV6_PKTOPTIONS|.
167
168\paragraph{Note about IPv6 options and destination address.}
169\addcontentsline{toc}{subsection}{IPv6 options and destination address}
170If \verb|sin6_flowinfo| does contain not zero flow label,
171destination address in \verb|sin6_addr| and non-fragmentable
172extension headers are ignored. Instead, kernel uses the values
173cached at flow setup (see below). However, for connected sockets
174kernel prefers the values set at connection time.
175
176\paragraph{Example.}
177\addcontentsline{toc}{subsection}{Example}
178After setting socket option \verb|IPV6_FLOWINFO|
179flowlabel and DS field are received as ancillary data object
180of type \verb|IPV6_FLOWINFO| and level \verb|SOL_IPV6|.
181In the cases when it is convenient to use \verb|recvfrom(2)|,
182it is possible to replace library variant with your own one,
183sort of:
184
185\begin{verbatim}
186#include <sys/socket.h>
187#include <netinet/in6.h>
188
189size_t recvfrom(int fd, char *buf, size_t len, int flags,
190 struct sockaddr *addr, int *addrlen)
191{
192 size_t cc;
193 char cbuf[128];
194 struct cmsghdr *c;
195 struct iovec iov = { buf, len };
196 struct msghdr msg = { addr, *addrlen,
197 &iov, 1,
198 cbuf, sizeof(cbuf),
199 0 };
200
201 cc = recvmsg(fd, &msg, flags);
202 if (cc < 0)
203 return cc;
204 ((struct sockaddr_in6*)addr)->sin6_flowinfo = 0;
205 *addrlen = msg.msg_namelen;
206 for (c=CMSG_FIRSTHDR(&msg); c; c = CMSG_NEXTHDR(&msg, c)) {
207 if (c->cmsg_level != SOL_IPV6 ||
208 c->cmsg_type != IPV6_FLOWINFO)
209 continue;
210 ((struct sockaddr_in6*)addr)->sin6_flowinfo = *(__u32*)CMSG_DATA(c);
211 }
212 return cc;
213}
214\end{verbatim}
215
216
217
218\section{Flow label management.}
219
220\paragraph{Discussion.}
221\addcontentsline{toc}{subsection}{Discussion}
222Requirements of RFC2460 are pretty tough. Particularly, lifetimes
223longer than boot time require to store allocated labels at stable
224storage, so that the full implementation necessarily includes user space flow
225label manager. There are at least three different approaches:
226
227\begin{enumerate}
228\item {\bf ``Cooperative''. } We could leave flow label allocation wholly
229to user space. When user needs label he requests manager directly. The approach
230is valid, but as any ``cooperative'' approach it suffers of security problems.
231
232\begin{NB}
233One idea is to disallow not privileged user to allocate flow
234labels, but instead to pass the socket to manager via \verb|SCM_RIGHTS|
235control message, so that it will allocate label and assign it to socket
236itself. Hmm... the idea is interesting.
237\end{NB}
238
239\item {\bf ``Indirect''.} Kernel redirects requests to user level daemon
240and does not install label until the daemon acknowledged the request.
241The approach is the most promising, it is especially pleasant to recognize
242parallel with IPsec API [RFC2367,Craig]. Actually, it may share API with
243IPsec.
244
245\item {\bf ``Stupid''.} To allocate labels in kernel space. It is the simplest
246method, but it suffers of two serious flaws: the first,
247we cannot lease labels with lifetimes longer than boot time, the second,
248it is sensitive to DoS attacks. Kernel have to remember all the obsolete
249labels until their expiration and malicious user may fastly eat all the
250flow label space.
251
252\end{enumerate}
253
254Certainly, I choose the most ``stupid'' method. It is the cheapest one
255for implementor (i.e.\ me), and taking into account that flow labels
256still have no serious applications it is not useful to work on more
257advanced API, especially, taking into account that eventually we
258will get it for no fee together with IPsec.
259
260
261\paragraph{Implementation.}
262\addcontentsline{toc}{subsection}{Implementation}
263Socket option \verb|IPV6_FLOWLABEL_MGR| allows to
264request flow label manager to allocate new flow label, to reuse
265already allocated one or to delete old flow label.
266Its argument is \verb|struct| \verb|in6_flowlabel_req|:
267
268\begin{verbatim}
269struct in6_flowlabel_req
270{
271 struct in6_addr flr_dst;
272 __u32 flr_label;
273 __u8 flr_action;
274 __u8 flr_share;
275 __u16 flr_flags;
276 __u16 flr_expires;
277 __u16 flr_linger;
278 __u32 __flr_reserved;
279 /* Options in format of IPV6_PKTOPTIONS */
280};
281\end{verbatim}
282
283\begin{itemize}
284
285\item \verb|dst| is IPv6 destination address associated with the label.
286
287\item \verb|label| is flow label value in network byte order. If it is zero,
288kernel will allocate new pseudo-random number. Otherwise, kernel will try
289to lease flow label ordered by user. In this case, it is user task to provide
290necessary flow label randomness.
291
292\item \verb|action| is requested operation. Currently, only three operations
293are defined:
294
295\begin{verbatim}
296#define IPV6_FL_A_GET 0 /* Get flow label */
297#define IPV6_FL_A_PUT 1 /* Release flow label */
298#define IPV6_FL_A_RENEW 2 /* Update expire time */
299\end{verbatim}
300
301\item \verb|flags| are optional modifiers. Currently
302only \verb|IPV6_FL_A_GET| has modifiers:
303
304\begin{verbatim}
305#define IPV6_FL_F_CREATE 1 /* Allowed to create new label */
306#define IPV6_FL_F_EXCL 2 /* Do not create new label */
307\end{verbatim}
308
309
310\item \verb|share| defines who is allowed to reuse the same flow label.
311
312\begin{verbatim}
313#define IPV6_FL_S_NONE 0 /* Not defined */
314#define IPV6_FL_S_EXCL 1 /* Label is private */
315#define IPV6_FL_S_PROCESS 2 /* May be reused by this process */
316#define IPV6_FL_S_USER 3 /* May be reused by this user */
317#define IPV6_FL_S_ANY 255 /* Anyone may reuse it */
318\end{verbatim}
319
320\item \verb|linger| is time in seconds. After the last user releases flow
321label, it will not be reused with different destination and options at least
322during this time. If \verb|share| is not \verb|IPV6_FL_S_EXCL| the label
323still can be shared by another sockets. Current implementation does not allow
324unprivileged user to set linger longer than 60 sec.
325
326\item \verb|expires| is time in seconds. Flow label will be kept at least
327for this time, but it will not be destroyed before user released it explicitly
328or closed all the sockets using it. Current implementation does not allow
329unprivileged user to set timeout longer than 60 sec. Proviledged applications
330MAY set longer lifetimes, but in this case they MUST save allocated
331labels at stable storage and restore them back after reboot before the first
332application allocates new flow.
333
334\end{itemize}
335
336This structure is followed by optional extension headers associated
337with this flow label in format of \verb|IPV6_PKTOPTIONS|. Only
338\verb|IPV6_HOPOPTS|, \verb|IPV6_RTHDR| and, if \verb|IPV6_RTHDR| presents,
339\verb|IPV6_DSTOPTS| are allowed.
340
341\paragraph{Example.}
342\addcontentsline{toc}{subsection}{Example}
343 The function \verb|get_flow_label| allocates
344private flow label.
345
346\begin{verbatim}
347int get_flow_label(int fd, struct sockaddr_in6 *dst, __u32 fl)
348{
349 int on = 1;
350 struct in6_flowlabel_req freq;
351
352 memset(&freq, 0, sizeof(freq));
353 freq.flr_label = htonl(fl);
354 freq.flr_action = IPV6_FL_A_GET;
355 freq.flr_flags = IPV6_FL_F_CREATE | IPV6_FL_F_EXCL;
356 freq.flr_share = IPV6_FL_S_EXCL;
357 memcpy(&freq.flr_dst, &dst->sin6_addr, 16);
358 if (setsockopt(fd, SOL_IPV6, IPV6_FLOWLABEL_MGR,
359 &freq, sizeof(freq)) == -1) {
360 perror ("can't lease flowlabel");
361 return -1;
362 }
363 dst->sin6_flowinfo |= freq.flr_label;
364
365 if (setsockopt(fd, SOL_IPV6, IPV6_FLOWINFO_SEND,
366 &on, sizeof(on)) == -1) {
367 perror ("can't send flowinfo");
368
369 freq.flr_action = IPV6_FL_A_PUT;
370 setsockopt(fd, SOL_IPV6, IPV6_FLOWLABEL_MGR,
371 &freq, sizeof(freq));
372 return -1;
373 }
374 return 0;
375}
376\end{verbatim}
377
378A bit more complicated example using routing header can be found
379in \verb|ping6| utility (\verb|iputils| package). Linux rsvpd backend
380contains an example of using operation \verb|IPV6_FL_A_RENEW|.
381
382\paragraph{Listing flow labels.}
383\addcontentsline{toc}{subsection}{Listing flow labels}
384List of currently allocated
385flow labels may be read from \verb|/proc/net/ip6_flowlabel|.
386
387\begin{verbatim}
388Label S Owner Users Linger Expires Dst Opt
389A1BE5 1 0 0 6 3 3ffe2400000000010a0020fffe71fb30 0
390\end{verbatim}
391
392\begin{itemize}
393\item \verb|Label| is hexadecimal flow label value.
394\item \verb|S| is sharing style.
395\item \verb|Owner| is ID of creator, it is zero, pid or uid, depending on
396 sharing style.
397\item \verb|Users| is number of applications using the label now.
398\item \verb|Linger| is \verb|linger| of this label in seconds.
399\item \verb|Expires| is time until expiration of the label in seconds. It may
400 be negative, if the label is in use.
401\item \verb|Dst| is IPv6 destination address.
402\item \verb|Opt| is length of options, associated with the label. Option
403 data are not accessible.
404\end{itemize}
405
406
407\paragraph{Flow labels and RSVP.}
408\addcontentsline{toc}{subsection}{Flow labels and RSVP}
409RSVP daemon supports IPv6 flow labels
410without any modifications to standard ISI RAPI. Sender must allocate
411flow label, fill corresponding sender template and submit it to local rsvp
412daemon. rsvpd will check the label and start to announce it in PATH
413messages. Rsvpd on sender node will renew the flow label, so that it will not
414be reused before path state expires and all the intermediate
415routers and receiver purge flow state.
416
417\verb|rtap| utility is modified to parse flow labels. F.e.\ if user allocated
418flow label \verb|0xA1234|, he may write:
419
420\begin{verbatim}
421RTAP> sender 3ffe:2400::1/FL0xA1234 <Tspec>
422\end{verbatim}
423