]> git.proxmox.com Git - pve-network.git/blame - PVE/Network/SDN/Zones/QinQPlugin.pm
d/control: fix description
[pve-network.git] / PVE / Network / SDN / Zones / QinQPlugin.pm
CommitLineData
f5eabba0 1package PVE::Network::SDN::Zones::QinQPlugin;
20e19696
AD
2
3use strict;
4use warnings;
3dfdc684 5use PVE::Network::SDN::Zones::Plugin;
1d44ce70 6use PVE::Exception qw(raise raise_param_exc);
20e19696 7
3dfdc684 8use base('PVE::Network::SDN::Zones::Plugin');
20e19696
AD
9
10sub type {
11 return 'qinq';
12}
13
20e19696
AD
14sub properties {
15 return {
1c95991c
TL
16 tag => {
17 type => 'integer',
18 minimum => 0,
19 description => "Service-VLAN Tag",
20 },
823f2e2a
AD
21 mtu => {
22 type => 'integer',
1c95991c 23 description => "MTU",
823f2e2a
AD
24 optional => 1,
25 },
3dfdc684
AD
26 'vlan-protocol' => {
27 type => 'string',
28 enum => ['802.1q', '802.1ad'],
29 default => '802.1q',
30 optional => 1,
31 }
20e19696
AD
32 };
33}
34
35sub options {
36
37 return {
c2b9c173 38 nodes => { optional => 1},
20e19696 39 'tag' => { optional => 0 },
938ebef7 40 'bridge' => { optional => 0 },
823f2e2a 41 'mtu' => { optional => 1 },
3dfdc684 42 'vlan-protocol' => { optional => 1 },
4ad78442
AD
43 dns => { optional => 1 },
44 reversedns => { optional => 1 },
45 dnszone => { optional => 1 },
57a335c4 46 ipam => { optional => 1 },
20e19696
AD
47 };
48}
49
50# Plugin implementation
51sub generate_sdn_config {
efffa0ff 52 my ($class, $plugin_config, $zoneid, $vnetid, $vnet, $controller, $controller_cfg, $subnet_cfg, $interfaces_config, $config) = @_;
20e19696 53
3dfdc684 54 my $stag = $plugin_config->{tag};
938ebef7
AD
55 my $mtu = $plugin_config->{mtu};
56 my $bridge = $plugin_config->{'bridge'};
3dfdc684
AD
57 my $vlanprotocol = $plugin_config->{'vlan-protocol'};
58 my $ctag = $vnet->{tag};
59 my $alias = $vnet->{alias};
20e19696 60
fdf22d5f
AD
61 PVE::Network::SDN::Zones::Plugin::find_bridge($bridge);
62
63 my $vlan_aware = PVE::Network::SDN::Zones::Plugin::is_vlanaware($bridge);
64 my $is_ovs = PVE::Network::SDN::Zones::Plugin::is_ovs($bridge);
20e19696 65
3dfdc684
AD
66 my @iface_config = ();
67 my $vnet_bridge_ports = "";
68
69 if($is_ovs) {
70
71 #ovs--->ovsintport(dot1q-tunnel tag)------->vlanawarebrige-----(tag)--->vnet
72
73 $vlanprotocol = "802.1q" if !$vlanprotocol;
74 my $svlan_iface = "sv_".$zoneid;
75 my $zone = "z_$zoneid";
76
77 #ovs dot1q-tunnel port
78 @iface_config = ();
79 push @iface_config, "ovs_type OVSIntPort";
80 push @iface_config, "ovs_bridge $bridge";
82159388 81 push @iface_config, "ovs_mtu $mtu" if $mtu;
3dfdc684
AD
82 push @iface_config, "ovs_options vlan_mode=dot1q-tunnel tag=$stag other_config:qinq-ethtype=$vlanprotocol";
83 push(@{$config->{$svlan_iface}}, @iface_config) if !$config->{$svlan_iface};
84
d8c88170
AD
85 #redefine main ovs bridge, ifupdown2 will merge ovs_ports
86 @{$config->{$bridge}}[0] = "ovs_ports" if !@{$config->{$bridge}}[0];
87 my @ovs_ports = split / / , @{$config->{$bridge}}[0];
88 @{$config->{$bridge}}[0] .= " $svlan_iface" if !grep( $_ eq $svlan_iface, @ovs_ports );
3dfdc684
AD
89
90 #zone vlan aware bridge
91 @iface_config = ();
938ebef7
AD
92 push @iface_config, "mtu $mtu" if $mtu;
93 push @iface_config, "bridge-stp off";
3dfdc684 94 push @iface_config, "bridge-ports $svlan_iface";
938ebef7
AD
95 push @iface_config, "bridge-fd 0";
96 push @iface_config, "bridge-vlan-aware yes";
97 push @iface_config, "bridge-vids 2-4094";
3dfdc684
AD
98 push(@{$config->{$zone}}, @iface_config) if !$config->{$zone};
99
100 $vnet_bridge_ports = "$zone.$ctag";
101
102 } elsif ($vlan_aware) {
103
104 #vlanawarebrige-(tag)----->vlanwarebridge-(tag)----->vnet
938ebef7 105
3dfdc684
AD
106 my $zone = "z_$zoneid";
107
108 if($vlanprotocol) {
109 @iface_config = ();
110 push @iface_config, "bridge-vlan-protocol $vlanprotocol";
111 push(@{$config->{$bridge}}, @iface_config) if !$config->{$bridge};
112 }
113
114 #zone vlan bridge
938ebef7 115 @iface_config = ();
3dfdc684
AD
116 push @iface_config, "mtu $mtu" if $mtu;
117 push @iface_config, "bridge-stp off";
118 push @iface_config, "bridge-ports $bridge.$stag";
119 push @iface_config, "bridge-fd 0";
120 push @iface_config, "bridge-vlan-aware yes";
121 push @iface_config, "bridge-vids 2-4094";
122 push(@{$config->{$zone}}, @iface_config) if !$config->{$zone};
123
124 $vnet_bridge_ports = "$zone.$ctag";
125
126 } else {
127
128 #eth--->eth.x(svlan)--->eth.x.y(cvlan)---->vnet
129
fdf22d5f 130 my @bridge_ifaces = PVE::Network::SDN::Zones::Plugin::get_bridge_ifaces($bridge);
3dfdc684
AD
131
132 foreach my $bridge_iface (@bridge_ifaces) {
133
134 # use named vlan interface to avoid too long names
2fa5d392 135 my $svlan_iface = "sv_$zoneid";
3dfdc684
AD
136 my $cvlan_iface = "cv_$vnetid";
137
138 #svlan
139 @iface_config = ();
140 push @iface_config, "vlan-raw-device $bridge_iface";
141 push @iface_config, "vlan-id $stag";
142 push @iface_config, "vlan-protocol $vlanprotocol" if $vlanprotocol;
143 push(@{$config->{$svlan_iface}}, @iface_config) if !$config->{$svlan_iface};
144
145 #cvlan
146 @iface_config = ();
147 push @iface_config, "vlan-raw-device $svlan_iface";
148 push @iface_config, "vlan-id $ctag";
149 push(@{$config->{$cvlan_iface}}, @iface_config) if !$config->{$cvlan_iface};
150
151 $vnet_bridge_ports .= " $cvlan_iface";
152 }
153 }
154
155 #vnet bridge
156 @iface_config = ();
157 push @iface_config, "bridge_ports $vnet_bridge_ports";
158 push @iface_config, "bridge_stp off";
159 push @iface_config, "bridge_fd 0";
912fb443
AD
160 if($vnet->{vlanaware}) {
161 push @iface_config, "bridge-vlan-aware yes";
162 push @iface_config, "bridge-vids 2-4094";
163 }
3dfdc684
AD
164 push @iface_config, "mtu $mtu" if $mtu;
165 push @iface_config, "alias $alias" if $alias;
166 push(@{$config->{$vnetid}}, @iface_config) if !$config->{$vnetid};
167
20e19696
AD
168}
169
58433186 170sub status {
4d7cc94f 171 my ($class, $plugin_config, $zone, $vnetid, $vnet, $status) = @_;
58433186
AD
172
173 my $bridge = $plugin_config->{bridge};
4d7cc94f
AD
174 my $err_msg = [];
175
176 if (!-d "/sys/class/net/$bridge") {
177 push @$err_msg, "missing $bridge";
178 return $err_msg;
179 }
180
fdf22d5f
AD
181 my $vlan_aware = PVE::Network::SDN::Zones::Plugin::is_vlanaware($bridge);
182 my $is_ovs = PVE::Network::SDN::Zones::Plugin::is_ovs($bridge);
4d7cc94f
AD
183
184 my $tag = $vnet->{tag};
185 my $vnet_uplink = "ln_".$vnetid;
186 my $vnet_uplinkpeer = "pr_".$vnetid;
187
188 # ifaces to check
189 my $ifaces = [ $vnetid, $bridge ];
190 if($is_ovs) {
191 my $svlan_iface = "sv_".$zone;
192 my $zonebridge = "z_$zone";
193 push @$ifaces, $svlan_iface;
194 push @$ifaces, $zonebridge;
195 } elsif ($vlan_aware) {
196 my $zonebridge = "z_$zone";
197 push @$ifaces, $zonebridge;
58433186 198 } else {
4d7cc94f
AD
199 my $svlan_iface = "sv_$vnetid";
200 my $cvlan_iface = "cv_$vnetid";
201 push @$ifaces, $svlan_iface;
202 push @$ifaces, $cvlan_iface;
203 }
204
205 foreach my $iface (@{$ifaces}) {
206 if (!$status->{$iface}->{status}) {
207 push @$err_msg, "missing $iface";
208 } elsif ($status->{$iface}->{status} ne 'pass') {
209 push @$err_msg, "error $iface";
210 }
58433186 211 }
4d7cc94f 212 return $err_msg;
58433186
AD
213}
214
5ca07ed9 215sub vnet_update_hook {
88d9562b
AD
216 my ($class, $vnet_cfg, $vnetid, $zone_cfg) = @_;
217
218 my $vnet = $vnet_cfg->{ids}->{$vnetid};
219 my $tag = $vnet->{tag};
1d44ce70 220
5ca07ed9
AD
221 raise_param_exc({ tag => "missing vlan tag"}) if !defined($vnet->{tag});
222 raise_param_exc({ tag => "vlan tag max value is 4096"}) if $vnet->{tag} > 4096;
88d9562b
AD
223
224 # verify that tag is not already defined in another vnet on same zone
225 foreach my $id (keys %{$vnet_cfg->{ids}}) {
226 next if $id eq $vnetid;
227 my $othervnet = $vnet_cfg->{ids}->{$id};
228 my $other_tag = $othervnet->{tag};
229 next if $vnet->{zone} ne $othervnet->{zone};
230 raise_param_exc({ tag => "tag $tag already exist in vnet $id"}) if $other_tag && $tag eq $other_tag;
231 }
1d44ce70
AD
232}
233
20e19696
AD
2341;
235
236