Commit | Line | Data |
---|---|---|
11fdf7f2 TL |
1 | # Block Device User Guide {#bdev} |
2 | ||
3 | # Introduction {#bdev_ug_introduction} | |
4 | ||
5 | The SPDK block device layer, often simply called *bdev*, is a C library | |
6 | intended to be equivalent to the operating system block storage layer that | |
7 | often sits immediately above the device drivers in a traditional kernel | |
8 | storage stack. Specifically, this library provides the following | |
9 | functionality: | |
10 | ||
11 | * A pluggable module API for implementing block devices that interface with different types of block storage devices. | |
12 | * Driver modules for NVMe, malloc (ramdisk), Linux AIO, virtio-scsi, Ceph RBD, Pmem and Vhost-SCSI Initiator and more. | |
13 | * An application API for enumerating and claiming SPDK block devices and then performing operations (read, write, unmap, etc.) on those devices. | |
14 | * Facilities to stack block devices to create complex I/O pipelines, including logical volume management (lvol) and partition support (GPT). | |
15 | * Configuration of block devices via JSON-RPC. | |
16 | * Request queueing, timeout, and reset handling. | |
17 | * Multiple, lockless queues for sending I/O to block devices. | |
18 | ||
19 | Bdev module creates abstraction layer that provides common API for all devices. | |
20 | User can use available bdev modules or create own module with any type of | |
21 | device underneath (please refer to @ref bdev_module for details). SPDK | |
22 | provides also vbdev modules which creates block devices on existing bdev. For | |
23 | example @ref bdev_ug_logical_volumes or @ref bdev_ug_gpt | |
24 | ||
25 | # Prerequisites {#bdev_ug_prerequisites} | |
26 | ||
27 | This guide assumes that you can already build the standard SPDK distribution | |
28 | on your platform. The block device layer is a C library with a single public | |
29 | header file named bdev.h. All SPDK configuration described in following | |
30 | chapters is done by using JSON-RPC commands. SPDK provides a python-based | |
31 | command line tool for sending RPC commands located at `scripts/rpc.py`. User | |
32 | can list available commands by running this script with `-h` or `--help` flag. | |
33 | Additionally user can retrieve currently supported set of RPC commands | |
9f95a23c | 34 | directly from SPDK application by running `scripts/rpc.py rpc_get_methods`. |
11fdf7f2 TL |
35 | Detailed help for each command can be displayed by adding `-h` flag as a |
36 | command parameter. | |
37 | ||
38 | # General Purpose RPCs {#bdev_ug_general_rpcs} | |
39 | ||
40 | ## get_bdevs {#bdev_ug_get_bdevs} | |
41 | ||
42 | List of currently available block devices including detailed information about | |
43 | them can be get by using `get_bdevs` RPC command. User can add optional | |
44 | parameter `name` to get details about specified by that name bdev. | |
45 | ||
46 | Example response | |
47 | ||
48 | ~~~ | |
49 | { | |
50 | "num_blocks": 32768, | |
51 | "assigned_rate_limits": { | |
52 | "rw_ios_per_sec": 10000, | |
53 | "rw_mbytes_per_sec": 20 | |
54 | }, | |
55 | "supported_io_types": { | |
56 | "reset": true, | |
57 | "nvme_admin": false, | |
58 | "unmap": true, | |
59 | "read": true, | |
60 | "write_zeroes": true, | |
61 | "write": true, | |
62 | "flush": true, | |
63 | "nvme_io": false | |
64 | }, | |
65 | "driver_specific": {}, | |
66 | "claimed": false, | |
67 | "block_size": 4096, | |
68 | "product_name": "Malloc disk", | |
69 | "name": "Malloc0" | |
70 | } | |
71 | ~~~ | |
72 | ||
73 | ## set_bdev_qos_limit {#set_bdev_qos_limit} | |
74 | ||
75 | Users can use the `set_bdev_qos_limit` RPC command to enable, adjust, and disable | |
76 | rate limits on an existing bdev. Two types of rate limits are supported: | |
77 | IOPS and bandwidth. The rate limits can be enabled, adjusted, and disabled at any | |
78 | time for the specified bdev. The bdev name is a required parameter for this | |
79 | RPC command and at least one of `rw_ios_per_sec` and `rw_mbytes_per_sec` must be | |
80 | specified. When both rate limits are enabled, the first met limit will | |
81 | take effect. The value 0 may be specified to disable the corresponding rate | |
82 | limit. Users can run this command with `-h` or `--help` for more information. | |
83 | ||
9f95a23c | 84 | ## Histograms {#rpc_bdev_histogram} |
11fdf7f2 | 85 | |
9f95a23c TL |
86 | The `enable_bdev_histogram` RPC command allows to enable or disable gathering |
87 | latency data for specified bdev. Histogram can be downloaded by the user by | |
88 | calling `get_bdev_histogram` and parsed using scripts/histogram.py script. | |
89 | ||
90 | Example command | |
91 | ||
92 | `rpc.py enable_bdev_histogram Nvme0n1 --enable` | |
93 | ||
94 | The command will enable gathering data for histogram on Nvme0n1 device. | |
95 | ||
96 | `rpc.py get_bdev_histogram Nvme0n1 | histogram.py` | |
97 | ||
98 | The command will download gathered histogram data. The script will parse | |
99 | the data and show table containing IO count for latency ranges. | |
100 | ||
101 | `rpc.py enable_bdev_histogram Nvme0n1 --disable` | |
102 | ||
103 | The command will disable histogram on Nvme0n1 device. | |
11fdf7f2 TL |
104 | |
105 | # Ceph RBD {#bdev_config_rbd} | |
106 | ||
107 | The SPDK RBD bdev driver provides SPDK block layer access to Ceph RADOS block | |
108 | devices (RBD). Ceph RBD devices are accessed via librbd and librados libraries | |
109 | to access the RADOS block device exported by Ceph. To create Ceph bdev RPC | |
110 | command `construct_rbd_bdev` should be used. | |
111 | ||
112 | Example command | |
113 | ||
114 | `rpc.py construct_rbd_bdev rbd foo 512` | |
115 | ||
116 | This command will create a bdev that represents the 'foo' image from a pool called 'rbd'. | |
117 | ||
118 | To remove a block device representation use the delete_rbd_bdev command. | |
119 | ||
120 | `rpc.py delete_rbd_bdev Rbd0` | |
121 | ||
122 | # Crypto Virtual Bdev Module {#bdev_config_crypto} | |
123 | ||
124 | The crypto virtual bdev module can be configured to provide at rest data encryption | |
125 | for any underlying bdev. The module relies on the DPDK CryptoDev Framework to provide | |
126 | all cryptographic functionality. The framework provides support for many different software | |
127 | only cryptographic modules as well hardware assisted support for the Intel QAT board. The | |
128 | framework also provides support for cipher, hash, authentication and AEAD functions. At this | |
129 | time the SPDK virtual bdev module supports cipher only as follows: | |
130 | ||
131 | - AESN-NI Multi Buffer Crypto Poll Mode Driver: RTE_CRYPTO_CIPHER_AES128_CBC | |
132 | - Intel(R) QuickAssist (QAT) Crypto Poll Mode Driver: RTE_CRYPTO_CIPHER_AES128_CBC | |
133 | (Note: QAT is functional however is marked as experimental until the hardware has | |
134 | been fully integrated with the SPDK CI system.) | |
135 | ||
136 | In order to support using the bdev block offset (LBA) as the initialization vector (IV), | |
137 | the crypto module break up all I/O into crypto operations of a size equal to the block | |
138 | size of the underlying bdev. For example, a 4K I/O to a bdev with a 512B block size, | |
139 | would result in 8 cryptographic operations. | |
140 | ||
141 | For reads, the buffer provided to the crypto module will be used as the destination buffer | |
142 | for unencrypted data. For writes, however, a temporary scratch buffer is used as the | |
143 | destination buffer for encryption which is then passed on to the underlying bdev as the | |
144 | write buffer. This is done to avoid encrypting the data in the original source buffer which | |
145 | may cause problems in some use cases. | |
146 | ||
147 | Example command | |
148 | ||
149 | `rpc.py construct_crypto_bdev -b NVMe1n1 -c CryNvmeA -d crypto_aesni_mb -k 0123456789123456` | |
150 | ||
151 | This command will create a crypto vbdev called 'CryNvmeA' on top of the NVMe bdev | |
152 | 'NVMe1n1' and will use the DPDK software driver 'crypto_aesni_mb' and the key | |
153 | '0123456789123456'. | |
154 | ||
155 | To remove the vbdev use the delete_crypto_bdev command. | |
156 | ||
157 | `rpc.py delete_crypto_bdev CryNvmeA` | |
158 | ||
159 | # GPT (GUID Partition Table) {#bdev_config_gpt} | |
160 | ||
161 | The GPT virtual bdev driver is enabled by default and does not require any configuration. | |
162 | It will automatically detect @ref bdev_ug_gpt on any attached bdev and will create | |
163 | possibly multiple virtual bdevs. | |
164 | ||
165 | ## SPDK GPT partition table {#bdev_ug_gpt} | |
166 | ||
167 | The SPDK partition type GUID is `7c5222bd-8f5d-4087-9c00-bf9843c7b58c`. Existing SPDK bdevs | |
168 | can be exposed as Linux block devices via NBD and then ca be partitioned with | |
169 | standard partitioning tools. After partitioning, the bdevs will need to be deleted and | |
170 | attached again for the GPT bdev module to see any changes. NBD kernel module must be | |
171 | loaded first. To create NBD bdev user should use `start_nbd_disk` RPC command. | |
172 | ||
173 | Example command | |
174 | ||
175 | `rpc.py start_nbd_disk Malloc0 /dev/nbd0` | |
176 | ||
177 | This will expose an SPDK bdev `Malloc0` under the `/dev/nbd0` block device. | |
178 | ||
179 | To remove NBD device user should use `stop_nbd_disk` RPC command. | |
180 | ||
181 | Example command | |
182 | ||
183 | `rpc.py stop_nbd_disk /dev/nbd0` | |
184 | ||
185 | To display full or specified nbd device list user should use `get_nbd_disks` RPC command. | |
186 | ||
187 | Example command | |
188 | ||
189 | `rpc.py stop_nbd_disk -n /dev/nbd0` | |
190 | ||
191 | ## Creating a GPT partition table using NBD {#bdev_ug_gpt_create_part} | |
192 | ||
193 | ~~~ | |
194 | # Expose bdev Nvme0n1 as kernel block device /dev/nbd0 by JSON-RPC | |
195 | rpc.py start_nbd_disk Nvme0n1 /dev/nbd0 | |
196 | ||
197 | # Create GPT partition table. | |
198 | parted -s /dev/nbd0 mklabel gpt | |
199 | ||
200 | # Add a partition consuming 50% of the available space. | |
201 | parted -s /dev/nbd0 mkpart MyPartition '0%' '50%' | |
202 | ||
203 | # Change the partition type to the SPDK GUID. | |
204 | # sgdisk is part of the gdisk package. | |
205 | sgdisk -t 1:7c5222bd-8f5d-4087-9c00-bf9843c7b58c /dev/nbd0 | |
206 | ||
207 | # Stop the NBD device (stop exporting /dev/nbd0). | |
208 | rpc.py stop_nbd_disk /dev/nbd0 | |
209 | ||
210 | # Now Nvme0n1 is configured with a GPT partition table, and | |
211 | # the first partition will be automatically exposed as | |
212 | # Nvme0n1p1 in SPDK applications. | |
213 | ~~~ | |
214 | ||
215 | # iSCSI bdev {#bdev_config_iscsi} | |
216 | ||
217 | The SPDK iSCSI bdev driver depends on libiscsi and hence is not enabled by default. | |
218 | In order to use it, build SPDK with an extra `--with-iscsi-initiator` configure option. | |
219 | ||
220 | The following command creates an `iSCSI0` bdev from a single LUN exposed at given iSCSI URL | |
221 | with `iqn.2016-06.io.spdk:init` as the reported initiator IQN. | |
222 | ||
223 | `rpc.py construct_iscsi_bdev -b iSCSI0 -i iqn.2016-06.io.spdk:init --url iscsi://127.0.0.1/iqn.2016-06.io.spdk:disk1/0` | |
224 | ||
225 | The URL is in the following format: | |
226 | `iscsi://[<username>[%<password>]@]<host>[:<port>]/<target-iqn>/<lun>` | |
227 | ||
228 | # Linux AIO bdev {#bdev_config_aio} | |
229 | ||
230 | The SPDK AIO bdev driver provides SPDK block layer access to Linux kernel block | |
231 | devices or a file on a Linux filesystem via Linux AIO. Note that O_DIRECT is | |
232 | used and thus bypasses the Linux page cache. This mode is probably as close to | |
233 | a typical kernel based target as a user space target can get without using a | |
234 | user-space driver. To create AIO bdev RPC command `construct_aio_bdev` should be | |
235 | used. | |
236 | ||
237 | Example commands | |
238 | ||
239 | `rpc.py construct_aio_bdev /dev/sda aio0` | |
240 | ||
241 | This command will create `aio0` device from /dev/sda. | |
242 | ||
243 | `rpc.py construct_aio_bdev /tmp/file file 8192` | |
244 | ||
245 | This command will create `file` device with block size 8192 from /tmp/file. | |
246 | ||
247 | To delete an aio bdev use the delete_aio_bdev command. | |
248 | ||
249 | `rpc.py delete_aio_bdev aio0` | |
250 | ||
9f95a23c TL |
251 | # OCF Virtual bdev {#bdev_config_cas} |
252 | ||
253 | OCF virtual bdev module is based on [Open CAS Framework](https://github.com/Open-CAS/ocf) - a | |
254 | high performance block storage caching meta-library. | |
255 | To enable the module, configure SPDK using `--with-ocf` flag. | |
256 | OCF bdev can be used to enable caching for any underlying bdev. | |
257 | ||
258 | Below is an example command for creating OCF bdev: | |
259 | ||
260 | `rpc.py construct_ocf_bdev Cache1 wt Malloc0 Nvme0n1` | |
261 | ||
262 | This command will create new OCF bdev `Cache1` having bdev `Malloc0` as caching-device | |
263 | and `Nvme0n1` as core-device and initial cache mode `Write-Through`. | |
264 | `Malloc0` will be used as cache for `Nvme0n1`, so data written to `Cache1` will be present | |
265 | on `Nvme0n1` eventually. | |
266 | By default, OCF will be configured with cache line size equal 4KiB | |
267 | and non-volatile metadata will be disabled. | |
268 | ||
269 | To remove `Cache1`: | |
270 | ||
271 | `rpc.py delete_ocf_bdev Cache1` | |
272 | ||
273 | During removal OCF-cache will be stopped and all cached data will be written to the core device. | |
274 | ||
275 | Note that OCF has a per-device RAM requirement | |
276 | of about 56000 + _cache device size_ * 58 / _cache line size_ (in bytes). | |
277 | To get more information on OCF | |
278 | please visit [OCF documentation](https://open-cas.github.io/). | |
279 | ||
11fdf7f2 TL |
280 | # Malloc bdev {#bdev_config_malloc} |
281 | ||
282 | Malloc bdevs are ramdisks. Because of its nature they are volatile. They are created from hugepage memory given to SPDK | |
283 | application. | |
284 | ||
285 | # Null {#bdev_config_null} | |
286 | ||
287 | The SPDK null bdev driver is a dummy block I/O target that discards all writes and returns undefined | |
288 | data for reads. It is useful for benchmarking the rest of the bdev I/O stack with minimal block | |
289 | device overhead and for testing configurations that can't easily be created with the Malloc bdev. | |
290 | To create Null bdev RPC command `construct_null_bdev` should be used. | |
291 | ||
292 | Example command | |
293 | ||
294 | `rpc.py construct_null_bdev Null0 8589934592 4096` | |
295 | ||
296 | This command will create an 8 petabyte `Null0` device with block size 4096. | |
297 | ||
298 | To delete a null bdev use the delete_null_bdev command. | |
299 | ||
300 | `rpc.py delete_null_bdev Null0` | |
301 | ||
302 | # NVMe bdev {#bdev_config_nvme} | |
303 | ||
304 | There are two ways to create block device based on NVMe device in SPDK. First | |
305 | way is to connect local PCIe drive and second one is to connect NVMe-oF device. | |
306 | In both cases user should use `construct_nvme_bdev` RPC command to achieve that. | |
307 | ||
308 | Example commands | |
309 | ||
310 | `rpc.py construct_nvme_bdev -b NVMe1 -t PCIe -a 0000:01:00.0` | |
311 | ||
312 | This command will create NVMe bdev of physical device in the system. | |
313 | ||
314 | `rpc.py construct_nvme_bdev -b Nvme0 -t RDMA -a 192.168.100.1 -f IPv4 -s 4420 -n nqn.2016-06.io.spdk:cnode1` | |
315 | ||
316 | This command will create NVMe bdev of NVMe-oF resource. | |
317 | ||
318 | To remove a NVMe controller use the delete_nvme_controller command. | |
319 | ||
320 | `rpc.py delete_nvme_controller Nvme0` | |
321 | ||
322 | This command will remove NVMe controller named Nvme0. | |
323 | ||
324 | # Logical volumes {#bdev_ug_logical_volumes} | |
325 | ||
326 | The Logical Volumes library is a flexible storage space management system. It allows | |
327 | creating and managing virtual block devices with variable size on top of other bdevs. | |
328 | The SPDK Logical Volume library is built on top of @ref blob. For detailed description | |
329 | please refer to @ref lvol. | |
330 | ||
331 | ## Logical volume store {#bdev_ug_lvol_store} | |
332 | ||
333 | Before creating any logical volumes (lvols), an lvol store has to be created first on | |
334 | selected block device. Lvol store is lvols vessel responsible for managing underlying | |
335 | bdev space assignment to lvol bdevs and storing metadata. To create lvol store user | |
336 | should use using `construct_lvol_store` RPC command. | |
337 | ||
338 | Example command | |
339 | ||
340 | `rpc.py construct_lvol_store Malloc2 lvs -c 4096` | |
341 | ||
342 | This will create lvol store named `lvs` with cluster size 4096, build on top of | |
343 | `Malloc2` bdev. In response user will be provided with uuid which is unique lvol store | |
344 | identifier. | |
345 | ||
346 | User can get list of available lvol stores using `get_lvol_stores` RPC command (no | |
347 | parameters available). | |
348 | ||
349 | Example response | |
350 | ||
351 | ~~~ | |
352 | { | |
353 | "uuid": "330a6ab2-f468-11e7-983e-001e67edf35d", | |
354 | "base_bdev": "Malloc2", | |
355 | "free_clusters": 8190, | |
356 | "cluster_size": 8192, | |
357 | "total_data_clusters": 8190, | |
358 | "block_size": 4096, | |
359 | "name": "lvs" | |
360 | } | |
361 | ~~~ | |
362 | ||
363 | To delete lvol store user should use `destroy_lvol_store` RPC command. | |
364 | ||
365 | Example commands | |
366 | ||
367 | `rpc.py destroy_lvol_store -u 330a6ab2-f468-11e7-983e-001e67edf35d` | |
368 | ||
369 | `rpc.py destroy_lvol_store -l lvs` | |
370 | ||
371 | ## Lvols {#bdev_ug_lvols} | |
372 | ||
373 | To create lvols on existing lvol store user should use `construct_lvol_bdev` RPC command. | |
374 | Each created lvol will be represented by new bdev. | |
375 | ||
376 | Example commands | |
377 | ||
378 | `rpc.py construct_lvol_bdev lvol1 25 -l lvs` | |
379 | ||
380 | `rpc.py construct_lvol_bdev lvol2 25 -u 330a6ab2-f468-11e7-983e-001e67edf35d` | |
381 | ||
9f95a23c TL |
382 | # RAID {#bdev_ug_raid} |
383 | ||
384 | RAID virtual bdev module provides functionality to combine any SPDK bdevs into | |
385 | one RAID bdev. Currently SPDK supports only RAID 0. RAID functionality does not | |
386 | store on-disk metadata on the member disks, so user must reconstruct the RAID | |
387 | volume when restarting application. User may specify member disks to create RAID | |
388 | volume event if they do not exists yet - as the member disks are registered at | |
389 | a later time, the RAID module will claim them and will surface the RAID volume | |
390 | after all of the member disks are available. It is allowed to use disks of | |
391 | different sizes - the smallest disk size will be the amount of space used on | |
392 | each member disk. | |
393 | ||
394 | Example commands | |
395 | ||
396 | `rpc.py construct_raid_bdev -n Raid0 -z 64 -r 0 -b "lvol0 lvol1 lvol2 lvol3"` | |
397 | ||
398 | `rpc.py get_raid_bdevs` | |
399 | ||
400 | `rpc.py destroy_raid_bdev Raid0` | |
401 | ||
11fdf7f2 TL |
402 | # Passthru {#bdev_config_passthru} |
403 | ||
404 | The SPDK Passthru virtual block device module serves as an example of how to write a | |
405 | virtual block device module. It implements the required functionality of a vbdev module | |
406 | and demonstrates some other basic features such as the use of per I/O context. | |
407 | ||
408 | Example commands | |
409 | ||
410 | `rpc.py construct_passthru_bdev -b aio -p pt` | |
411 | ||
412 | `rpc.py delete_passthru_bdev pt` | |
413 | ||
414 | # Pmem {#bdev_config_pmem} | |
415 | ||
416 | The SPDK pmem bdev driver uses pmemblk pool as the target for block I/O operations. For | |
417 | details on Pmem memory please refer to PMDK documentation on http://pmem.io website. | |
418 | First, user needs to configure SPDK to include PMDK support: | |
419 | ||
420 | `configure --with-pmdk` | |
421 | ||
422 | To create pmemblk pool for use with SPDK user should use `create_pmem_pool` RPC command. | |
423 | ||
424 | Example command | |
425 | ||
426 | `rpc.py create_pmem_pool /path/to/pmem_pool 25 4096` | |
427 | ||
428 | To get information on created pmem pool file user can use `pmem_pool_info` RPC command. | |
429 | ||
430 | Example command | |
431 | ||
432 | `rpc.py pmem_pool_info /path/to/pmem_pool` | |
433 | ||
434 | To remove pmem pool file user can use `delete_pmem_pool` RPC command. | |
435 | ||
436 | Example command | |
437 | ||
438 | `rpc.py delete_pmem_pool /path/to/pmem_pool` | |
439 | ||
440 | To create bdev based on pmemblk pool file user should use `construct_pmem_bdev ` RPC | |
441 | command. | |
442 | ||
443 | Example command | |
444 | ||
445 | `rpc.py construct_pmem_bdev /path/to/pmem_pool -n pmem` | |
446 | ||
447 | To remove a block device representation use the delete_pmem_bdev command. | |
448 | ||
449 | `rpc.py delete_pmem_bdev pmem` | |
450 | ||
451 | # Virtio Block {#bdev_config_virtio_blk} | |
452 | ||
453 | The Virtio-Block driver allows creating SPDK bdevs from Virtio-Block devices. | |
454 | ||
455 | The following command creates a Virtio-Block device named `VirtioBlk0` from a vhost-user | |
456 | socket `/tmp/vhost.0` exposed directly by SPDK @ref vhost. Optional `vq-count` and | |
457 | `vq-size` params specify number of request queues and queue depth to be used. | |
458 | ||
459 | `rpc.py construct_virtio_dev --dev-type blk --trtype user --traddr /tmp/vhost.0 --vq-count 2 --vq-size 512 VirtioBlk0` | |
460 | ||
461 | The driver can be also used inside QEMU-based VMs. The following command creates a Virtio | |
462 | Block device named `VirtioBlk0` from a Virtio PCI device at address `0000:00:01.0`. | |
463 | The entire configuration will be read automatically from PCI Configuration Space. It will | |
464 | reflect all parameters passed to QEMU's vhost-user-scsi-pci device. | |
465 | ||
466 | `rpc.py construct_virtio_dev --dev-type blk --trtype pci --traddr 0000:01:00.0 VirtioBlk1` | |
467 | ||
468 | Virtio-Block devices can be removed with the following command | |
469 | ||
470 | `rpc.py remove_virtio_bdev VirtioBlk0` | |
471 | ||
472 | # Virtio SCSI {#bdev_config_virtio_scsi} | |
473 | ||
474 | The Virtio-SCSI driver allows creating SPDK block devices from Virtio-SCSI LUNs. | |
475 | ||
476 | Virtio-SCSI bdevs are constructed the same way as Virtio-Block ones. | |
477 | ||
478 | `rpc.py construct_virtio_dev --dev-type scsi --trtype user --traddr /tmp/vhost.0 --vq-count 2 --vq-size 512 VirtioScsi0` | |
479 | ||
480 | `rpc.py construct_virtio_dev --dev-type scsi --trtype pci --traddr 0000:01:00.0 VirtioScsi0` | |
481 | ||
482 | Each Virtio-SCSI device may export up to 64 block devices named VirtioScsi0t0 ~ VirtioScsi0t63, | |
483 | one LUN (LUN0) per SCSI device. The above 2 commands will output names of all exposed bdevs. | |
484 | ||
485 | Virtio-SCSI devices can be removed with the following command | |
486 | ||