]> git.proxmox.com Git - mirror_edk2.git/blame_incremental - MdeModulePkg/Universal/PcatRealTimeClockRuntimeDxe/PcRtc.c
fixed DMA not be stopped issue when gBS->ExitBootServices called.
[mirror_edk2.git] / MdeModulePkg / Universal / PcatRealTimeClockRuntimeDxe / PcRtc.c
... / ...
CommitLineData
1/** @file\r
2 RTC Architectural Protocol GUID as defined in DxeCis 0.96.\r
3\r
4Copyright (c) 2006 - 2007, Intel Corporation\r
5All rights reserved. This program and the accompanying materials\r
6are licensed and made available under the terms and conditions of the BSD License\r
7which accompanies this distribution. The full text of the license may be found at\r
8http://opensource.org/licenses/bsd-license.php\r
9\r
10THE PROGRAM IS DISTRIBUTED UNDER THE BSD LICENSE ON AN "AS IS" BASIS,\r
11WITHOUT WARRANTIES OR REPRESENTATIONS OF ANY KIND, EITHER EXPRESS OR IMPLIED.\r
12\r
13**/\r
14\r
15#include "PcRtc.h"\r
16\r
17/**\r
18 Compare the Hour, Minute and Second of the From time and the To time.\r
19 \r
20 Only compare H/M/S in EFI_TIME and ignore other fields here.\r
21\r
22 @param From the first time\r
23 @param To the second time\r
24\r
25 @return >0 The H/M/S of the From time is later than those of To time\r
26 @return ==0 The H/M/S of the From time is same as those of To time\r
27 @return <0 The H/M/S of the From time is earlier than those of To time\r
28**/\r
29INTN\r
30CompareHMS (\r
31 IN EFI_TIME *From,\r
32 IN EFI_TIME *To\r
33 );\r
34\r
35/**\r
36 To check if second date is later than first date within 24 hours.\r
37\r
38 @param From the first date\r
39 @param To the second date\r
40\r
41 @retval TRUE From is previous to To within 24 hours.\r
42 @retval FALSE From is later, or it is previous to To more than 24 hours.\r
43**/\r
44BOOLEAN\r
45IsWithinOneDay (\r
46 IN EFI_TIME *From,\r
47 IN EFI_TIME *To\r
48 );\r
49\r
50/**\r
51 Read RTC content through its registers.\r
52\r
53 @param Address Address offset of RTC. It is recommended to use macros such as\r
54 RTC_ADDRESS_SECONDS.\r
55\r
56 @return The data of UINT8 type read from RTC.\r
57**/\r
58UINT8\r
59RtcRead (\r
60 IN UINT8 Address\r
61 )\r
62{\r
63 IoWrite8 (PCAT_RTC_ADDRESS_REGISTER, (UINT8) (Address | (UINT8) (IoRead8 (PCAT_RTC_ADDRESS_REGISTER) & 0x80)));\r
64 return IoRead8 (PCAT_RTC_DATA_REGISTER);\r
65}\r
66\r
67/**\r
68 Write RTC through its registers.\r
69\r
70 @param Address Address offset of RTC. It is recommended to use macros such as\r
71 RTC_ADDRESS_SECONDS.\r
72 @param Data The content you want to write into RTC.\r
73\r
74**/\r
75VOID\r
76RtcWrite (\r
77 IN UINT8 Address,\r
78 IN UINT8 Data\r
79 )\r
80{\r
81 IoWrite8 (PCAT_RTC_ADDRESS_REGISTER, (UINT8) (Address | (UINT8) (IoRead8 (PCAT_RTC_ADDRESS_REGISTER) & 0x80)));\r
82 IoWrite8 (PCAT_RTC_DATA_REGISTER, Data);\r
83}\r
84\r
85/**\r
86 Initialize RTC.\r
87\r
88 @param Global For global use inside this module.\r
89\r
90 @retval EFI_DEVICE_ERROR Initialization failed due to device error.\r
91 @retval EFI_SUCCESS Initialization successful.\r
92\r
93**/\r
94EFI_STATUS\r
95PcRtcInit (\r
96 IN PC_RTC_MODULE_GLOBALS *Global\r
97 )\r
98{\r
99 EFI_STATUS Status;\r
100 RTC_REGISTER_A RegisterA;\r
101 RTC_REGISTER_B RegisterB;\r
102 RTC_REGISTER_D RegisterD;\r
103 UINT8 Century;\r
104 EFI_TIME Time;\r
105 UINTN DataSize;\r
106 UINT32 TimerVar;\r
107\r
108 //\r
109 // Acquire RTC Lock to make access to RTC atomic\r
110 //\r
111 //Code here doesn't consider the runtime environment.\r
112 if (!EfiAtRuntime ()) {\r
113 EfiAcquireLock (&Global->RtcLock);\r
114 }\r
115 //\r
116 // Initialize RTC Register\r
117 //\r
118 // Make sure Division Chain is properly configured,\r
119 // or RTC clock won't "tick" -- time won't increment\r
120 //\r
121 RegisterA.Data = RTC_INIT_REGISTER_A;\r
122 RtcWrite (RTC_ADDRESS_REGISTER_A, RegisterA.Data);\r
123\r
124 //\r
125 // Read Register B\r
126 //\r
127 RegisterB.Data = RtcRead (RTC_ADDRESS_REGISTER_B);\r
128\r
129 //\r
130 // Clear RTC flag register\r
131 //\r
132 RtcRead (RTC_ADDRESS_REGISTER_C);\r
133\r
134 //\r
135 // Clear RTC register D\r
136 //\r
137 RegisterD.Data = RTC_INIT_REGISTER_D;\r
138 RtcWrite (RTC_ADDRESS_REGISTER_D, RegisterD.Data);\r
139\r
140 //\r
141 // Wait for up to 0.1 seconds for the RTC to be updated\r
142 //\r
143 Status = RtcWaitToUpdate (PcdGet32 (PcdRealTimeClockUpdateTimeout));\r
144 if (EFI_ERROR (Status)) {\r
145 //Code here doesn't consider the runtime environment.\r
146 if (!EfiAtRuntime ()) {\r
147 EfiReleaseLock (&Global->RtcLock);\r
148 }\r
149 return EFI_DEVICE_ERROR;\r
150 }\r
151 //\r
152 // Get the Time/Date/Daylight Savings values.\r
153 //\r
154 Time.Second = RtcRead (RTC_ADDRESS_SECONDS);\r
155 Time.Minute = RtcRead (RTC_ADDRESS_MINUTES);\r
156 Time.Hour = RtcRead (RTC_ADDRESS_HOURS);\r
157 Time.Day = RtcRead (RTC_ADDRESS_DAY_OF_THE_MONTH);\r
158 Time.Month = RtcRead (RTC_ADDRESS_MONTH);\r
159 Time.Year = RtcRead (RTC_ADDRESS_YEAR);\r
160\r
161 if (RtcTestCenturyRegister () == EFI_SUCCESS) {\r
162 Century = (UINT8) (RtcRead (RTC_ADDRESS_CENTURY) & 0x7f);\r
163 } else {\r
164 Century = RtcRead (RTC_ADDRESS_CENTURY);\r
165 }\r
166\r
167 //\r
168 // Set RTC configuration after get original time\r
169 // The value of bit AIE should be reserved.\r
170 //\r
171 RtcWrite (RTC_ADDRESS_REGISTER_B, (UINT8)(RTC_INIT_REGISTER_B | (RegisterB.Data & BIT5)));\r
172\r
173 //\r
174 // Release RTC Lock.\r
175 //\r
176 //Code here doesn't consider the runtime environment.\r
177 if (!EfiAtRuntime ()) {\r
178 EfiReleaseLock (&Global->RtcLock);\r
179 }\r
180 \r
181 //\r
182 // Validate time fields\r
183 //\r
184 Status = ConvertRtcTimeToEfiTime (&Time, Century, RegisterB);\r
185 if (!EFI_ERROR (Status)) {\r
186 Status = RtcTimeFieldsValid (&Time);\r
187 }\r
188 if (EFI_ERROR (Status)) {\r
189 Time.Second = RTC_INIT_SECOND;\r
190 Time.Minute = RTC_INIT_MINUTE;\r
191 Time.Hour = RTC_INIT_HOUR;\r
192 Time.Day = RTC_INIT_DAY;\r
193 Time.Month = RTC_INIT_MONTH;\r
194 Time.Year = RTC_INIT_YEAR;\r
195 }\r
196 //\r
197 // Get the data of Daylight saving and time zone, if they have been\r
198 // stored in NV variable during previous boot.\r
199 //\r
200 DataSize = sizeof (UINT32);\r
201 Status = EfiGetVariable (\r
202 L"RTC",\r
203 &gEfiCallerIdGuid,\r
204 NULL,\r
205 &DataSize,\r
206 (VOID *) &TimerVar\r
207 );\r
208 if (!EFI_ERROR (Status)) {\r
209 Global->SavedTimeZone = (INT16) TimerVar;\r
210 Global->Daylight = (UINT8) (TimerVar >> 16);\r
211\r
212 Time.TimeZone = Global->SavedTimeZone;\r
213 Time.Daylight = Global->Daylight;\r
214 }\r
215 //\r
216 // Reset time value according to new RTC configuration\r
217 //\r
218 PcRtcSetTime (&Time, Global);\r
219\r
220 return EFI_SUCCESS;\r
221}\r
222\r
223/**\r
224 Returns the current time and date information, and the time-keeping capabilities\r
225 of the hardware platform.\r
226\r
227 @param Time A pointer to storage to receive a snapshot of the current time.\r
228 @param Capabilities An optional pointer to a buffer to receive the real time clock\r
229 device's capabilities.\r
230 @param Global For global use inside this module.\r
231\r
232 @retval EFI_SUCCESS The operation completed successfully.\r
233 @retval EFI_INVALID_PARAMETER Time is NULL.\r
234 @retval EFI_DEVICE_ERROR The time could not be retrieved due to hardware error.\r
235\r
236**/\r
237EFI_STATUS\r
238PcRtcGetTime (\r
239 OUT EFI_TIME *Time,\r
240 OUT EFI_TIME_CAPABILITIES *Capabilities, OPTIONAL\r
241 IN PC_RTC_MODULE_GLOBALS *Global\r
242 )\r
243{\r
244 EFI_STATUS Status;\r
245 RTC_REGISTER_B RegisterB;\r
246 UINT8 Century;\r
247\r
248 //\r
249 // Check parameters for null pointer\r
250 //\r
251 if (Time == NULL) {\r
252 return EFI_INVALID_PARAMETER;\r
253\r
254 }\r
255 //\r
256 // Acquire RTC Lock to make access to RTC atomic\r
257 //\r
258 //Code here doesn't consider the runtime environment.\r
259 if (!EfiAtRuntime ()) {\r
260 EfiAcquireLock (&Global->RtcLock);\r
261 }\r
262 //\r
263 // Wait for up to 0.1 seconds for the RTC to be updated\r
264 //\r
265 Status = RtcWaitToUpdate (PcdGet32 (PcdRealTimeClockUpdateTimeout));\r
266 if (EFI_ERROR (Status)) {\r
267 //Code here doesn't consider the runtime environment.\r
268 if (!EfiAtRuntime ()) {\r
269 EfiReleaseLock (&Global->RtcLock);\r
270 }\r
271 return Status;\r
272 }\r
273 //\r
274 // Read Register B\r
275 //\r
276 RegisterB.Data = RtcRead (RTC_ADDRESS_REGISTER_B);\r
277\r
278 //\r
279 // Get the Time/Date/Daylight Savings values.\r
280 //\r
281 Time->Second = RtcRead (RTC_ADDRESS_SECONDS);\r
282 Time->Minute = RtcRead (RTC_ADDRESS_MINUTES);\r
283 Time->Hour = RtcRead (RTC_ADDRESS_HOURS);\r
284 Time->Day = RtcRead (RTC_ADDRESS_DAY_OF_THE_MONTH);\r
285 Time->Month = RtcRead (RTC_ADDRESS_MONTH);\r
286 Time->Year = RtcRead (RTC_ADDRESS_YEAR);\r
287\r
288 if (RtcTestCenturyRegister () == EFI_SUCCESS) {\r
289 Century = (UINT8) (RtcRead (RTC_ADDRESS_CENTURY) & 0x7f);\r
290 } else {\r
291 Century = RtcRead (RTC_ADDRESS_CENTURY);\r
292 }\r
293\r
294 //\r
295 // Release RTC Lock.\r
296 //\r
297 //Code here doesn't consider the runtime environment.\r
298 if (!EfiAtRuntime ()) {\r
299 EfiReleaseLock (&Global->RtcLock);\r
300 }\r
301 //\r
302 // Get the variable that contains the TimeZone and Daylight fields\r
303 //\r
304 Time->TimeZone = Global->SavedTimeZone;\r
305 Time->Daylight = Global->Daylight;\r
306\r
307 //\r
308 // Make sure all field values are in correct range\r
309 //\r
310 Status = ConvertRtcTimeToEfiTime (Time, Century, RegisterB);\r
311 if (!EFI_ERROR (Status)) {\r
312 Status = RtcTimeFieldsValid (Time);\r
313 }\r
314 if (EFI_ERROR (Status)) {\r
315 return EFI_DEVICE_ERROR;\r
316 }\r
317 //\r
318 // Fill in Capabilities if it was passed in\r
319 //\r
320 if (Capabilities != NULL) {\r
321 Capabilities->Resolution = 1;\r
322 //\r
323 // 1 hertz\r
324 //\r
325 Capabilities->Accuracy = 50000000;\r
326 //\r
327 // 50 ppm\r
328 //\r
329 Capabilities->SetsToZero = FALSE;\r
330 }\r
331\r
332 return EFI_SUCCESS;\r
333}\r
334\r
335/**\r
336 Sets the current local time and date information.\r
337\r
338 @param Time A pointer to the current time.\r
339 @param Global For global use inside this module.\r
340\r
341 @retval EFI_SUCCESS The operation completed successfully.\r
342 @retval EFI_INVALID_PARAMETER A time field is out of range.\r
343 @retval EFI_DEVICE_ERROR The time could not be set due due to hardware error.\r
344\r
345**/\r
346EFI_STATUS\r
347PcRtcSetTime (\r
348 IN EFI_TIME *Time,\r
349 IN PC_RTC_MODULE_GLOBALS *Global\r
350 )\r
351{\r
352 EFI_STATUS Status;\r
353 EFI_TIME RtcTime;\r
354 RTC_REGISTER_B RegisterB;\r
355 UINT8 Century;\r
356 UINT32 TimerVar;\r
357\r
358 if (Time == NULL) {\r
359 return EFI_INVALID_PARAMETER;\r
360 }\r
361 //\r
362 // Make sure that the time fields are valid\r
363 //\r
364 Status = RtcTimeFieldsValid (Time);\r
365 if (EFI_ERROR (Status)) {\r
366 return Status;\r
367 }\r
368\r
369 CopyMem (&RtcTime, Time, sizeof (EFI_TIME));\r
370\r
371 //\r
372 // Acquire RTC Lock to make access to RTC atomic\r
373 //\r
374 //Code here doesn't consider the runtime environment.\r
375 if (!EfiAtRuntime ()) {\r
376 EfiAcquireLock (&Global->RtcLock);\r
377 }\r
378 //\r
379 // Wait for up to 0.1 seconds for the RTC to be updated\r
380 //\r
381 Status = RtcWaitToUpdate (PcdGet32 (PcdRealTimeClockUpdateTimeout));\r
382 if (EFI_ERROR (Status)) {\r
383 //Code here doesn't consider the runtime environment.\r
384 if (!EfiAtRuntime ()) {\r
385 EfiReleaseLock (&Global->RtcLock);\r
386 }\r
387 return Status;\r
388 }\r
389 //\r
390 // Read Register B, and inhibit updates of the RTC\r
391 //\r
392 RegisterB.Data = RtcRead (RTC_ADDRESS_REGISTER_B);\r
393 RegisterB.Bits.SET = 1;\r
394 RtcWrite (RTC_ADDRESS_REGISTER_B, RegisterB.Data);\r
395\r
396 ConvertEfiTimeToRtcTime (&RtcTime, RegisterB, &Century);\r
397\r
398 RtcWrite (RTC_ADDRESS_SECONDS, RtcTime.Second);\r
399 RtcWrite (RTC_ADDRESS_MINUTES, RtcTime.Minute);\r
400 RtcWrite (RTC_ADDRESS_HOURS, RtcTime.Hour);\r
401 RtcWrite (RTC_ADDRESS_DAY_OF_THE_MONTH, RtcTime.Day);\r
402 RtcWrite (RTC_ADDRESS_MONTH, RtcTime.Month);\r
403 RtcWrite (RTC_ADDRESS_YEAR, (UINT8) RtcTime.Year);\r
404 if (RtcTestCenturyRegister () == EFI_SUCCESS) {\r
405 Century = (UINT8) ((Century & 0x7f) | (RtcRead (RTC_ADDRESS_CENTURY) & 0x80));\r
406 }\r
407\r
408 RtcWrite (RTC_ADDRESS_CENTURY, Century);\r
409\r
410 //\r
411 // Allow updates of the RTC registers\r
412 //\r
413 RegisterB.Bits.SET = 0;\r
414 RtcWrite (RTC_ADDRESS_REGISTER_B, RegisterB.Data);\r
415\r
416 //\r
417 // Release RTC Lock.\r
418 //\r
419 //Code here doesn't consider the runtime environment.\r
420 if (!EfiAtRuntime ()) {\r
421 EfiReleaseLock (&Global->RtcLock);\r
422 }\r
423 //\r
424 // Set the variable that contains the TimeZone and Daylight fields\r
425 //\r
426 Global->SavedTimeZone = Time->TimeZone;\r
427 Global->Daylight = Time->Daylight;\r
428\r
429 TimerVar = Time->Daylight;\r
430 TimerVar = (UINT32) ((TimerVar << 16) | Time->TimeZone);\r
431 Status = EfiSetVariable (\r
432 L"RTC",\r
433 &gEfiCallerIdGuid,\r
434 EFI_VARIABLE_BOOTSERVICE_ACCESS | EFI_VARIABLE_RUNTIME_ACCESS | EFI_VARIABLE_NON_VOLATILE,\r
435 sizeof (TimerVar),\r
436 &TimerVar\r
437 );\r
438 ASSERT_EFI_ERROR (Status);\r
439\r
440 return EFI_SUCCESS;\r
441}\r
442\r
443/**\r
444 Returns the current wakeup alarm clock setting.\r
445\r
446 @param Enabled Indicates if the alarm is currently enabled or disabled.\r
447 @param Pending Indicates if the alarm signal is pending and requires acknowledgment.\r
448 @param Time The current alarm setting.\r
449 @param Global For global use inside this module.\r
450\r
451 @retval EFI_SUCCESS The alarm settings were returned.\r
452 @retval EFI_INVALID_PARAMETER Enabled is NULL.\r
453 @retval EFI_INVALID_PARAMETER Pending is NULL.\r
454 @retval EFI_INVALID_PARAMETER Time is NULL.\r
455 @retval EFI_DEVICE_ERROR The wakeup time could not be retrieved due to a hardware error.\r
456 @retval EFI_UNSUPPORTED A wakeup timer is not supported on this platform.\r
457\r
458**/\r
459EFI_STATUS\r
460PcRtcGetWakeupTime (\r
461 OUT BOOLEAN *Enabled,\r
462 OUT BOOLEAN *Pending,\r
463 OUT EFI_TIME *Time,\r
464 IN PC_RTC_MODULE_GLOBALS *Global\r
465 )\r
466{\r
467 EFI_STATUS Status;\r
468 RTC_REGISTER_B RegisterB;\r
469 RTC_REGISTER_C RegisterC;\r
470 UINT8 Century;\r
471\r
472 //\r
473 // Check parameters for null pointers\r
474 //\r
475 if ((Enabled == NULL) || (Pending == NULL) || (Time == NULL)) {\r
476 return EFI_INVALID_PARAMETER;\r
477\r
478 }\r
479 //\r
480 // Acquire RTC Lock to make access to RTC atomic\r
481 //\r
482 //Code here doesn't consider the runtime environment.\r
483 if (!EfiAtRuntime ()) {\r
484 EfiAcquireLock (&Global->RtcLock);\r
485 }\r
486 //\r
487 // Wait for up to 0.1 seconds for the RTC to be updated\r
488 //\r
489 Status = RtcWaitToUpdate (PcdGet32 (PcdRealTimeClockUpdateTimeout));\r
490 if (EFI_ERROR (Status)) {\r
491 //Code here doesn't consider the runtime environment.\r
492 if (!EfiAtRuntime ()) {\r
493 EfiReleaseLock (&Global->RtcLock);\r
494 }\r
495 return EFI_DEVICE_ERROR;\r
496 }\r
497 //\r
498 // Read Register B and Register C\r
499 //\r
500 RegisterB.Data = RtcRead (RTC_ADDRESS_REGISTER_B);\r
501 RegisterC.Data = RtcRead (RTC_ADDRESS_REGISTER_C);\r
502\r
503 //\r
504 // Get the Time/Date/Daylight Savings values.\r
505 //\r
506 *Enabled = RegisterB.Bits.AIE;\r
507 if (*Enabled) {\r
508 Time->Second = RtcRead (RTC_ADDRESS_SECONDS_ALARM);\r
509 Time->Minute = RtcRead (RTC_ADDRESS_MINUTES_ALARM);\r
510 Time->Hour = RtcRead (RTC_ADDRESS_HOURS_ALARM);\r
511 Time->Day = RtcRead (RTC_ADDRESS_DAY_OF_THE_MONTH);\r
512 Time->Month = RtcRead (RTC_ADDRESS_MONTH);\r
513 Time->Year = RtcRead (RTC_ADDRESS_YEAR);\r
514 } else {\r
515 Time->Second = 0;\r
516 Time->Minute = 0;\r
517 Time->Hour = 0;\r
518 Time->Day = RtcRead (RTC_ADDRESS_DAY_OF_THE_MONTH);\r
519 Time->Month = RtcRead (RTC_ADDRESS_MONTH);\r
520 Time->Year = RtcRead (RTC_ADDRESS_YEAR);\r
521 }\r
522\r
523 if (RtcTestCenturyRegister () == EFI_SUCCESS) {\r
524 Century = (UINT8) (RtcRead (RTC_ADDRESS_CENTURY) & 0x7f);\r
525 } else {\r
526 Century = RtcRead (RTC_ADDRESS_CENTURY);\r
527 }\r
528\r
529 //\r
530 // Release RTC Lock.\r
531 //\r
532 //Code here doesn't consider the runtime environment.\r
533 if (!EfiAtRuntime ()) {\r
534 EfiReleaseLock (&Global->RtcLock);\r
535 }\r
536 //\r
537 // Make sure all field values are in correct range\r
538 //\r
539 Status = ConvertRtcTimeToEfiTime (Time, Century, RegisterB);\r
540 if (!EFI_ERROR (Status)) {\r
541 Status = RtcTimeFieldsValid (Time);\r
542 }\r
543 if (EFI_ERROR (Status)) {\r
544 return EFI_DEVICE_ERROR;\r
545 }\r
546\r
547 *Pending = RegisterC.Bits.AF;\r
548\r
549 return EFI_SUCCESS;\r
550}\r
551\r
552/**\r
553 Sets the system wakeup alarm clock time.\r
554\r
555 @param Enabled Enable or disable the wakeup alarm.\r
556 @param Time If Enable is TRUE, the time to set the wakeup alarm for.\r
557 If Enable is FALSE, then this parameter is optional, and may be NULL.\r
558 @param Global For global use inside this module.\r
559\r
560 @retval EFI_SUCCESS If Enable is TRUE, then the wakeup alarm was enabled.\r
561 If Enable is FALSE, then the wakeup alarm was disabled.\r
562 @retval EFI_INVALID_PARAMETER A time field is out of range.\r
563 @retval EFI_DEVICE_ERROR The wakeup time could not be set due to a hardware error.\r
564 @retval EFI_UNSUPPORTED A wakeup timer is not supported on this platform.\r
565\r
566**/\r
567EFI_STATUS\r
568PcRtcSetWakeupTime (\r
569 IN BOOLEAN Enable,\r
570 IN EFI_TIME *Time, OPTIONAL\r
571 IN PC_RTC_MODULE_GLOBALS *Global\r
572 )\r
573{\r
574 EFI_STATUS Status;\r
575 EFI_TIME RtcTime;\r
576 RTC_REGISTER_B RegisterB;\r
577 UINT8 Century;\r
578 EFI_TIME_CAPABILITIES Capabilities;\r
579\r
580 if (Enable) {\r
581\r
582 if (Time == NULL) {\r
583 return EFI_INVALID_PARAMETER;\r
584 }\r
585 //\r
586 // Make sure that the time fields are valid\r
587 //\r
588 Status = RtcTimeFieldsValid (Time);\r
589 if (EFI_ERROR (Status)) {\r
590 return EFI_INVALID_PARAMETER;\r
591 }\r
592 //\r
593 // Just support set alarm time within 24 hours\r
594 //\r
595 PcRtcGetTime (&RtcTime, &Capabilities, Global);\r
596 Status = RtcTimeFieldsValid (&RtcTime);\r
597 if (EFI_ERROR (Status)) {\r
598 return EFI_DEVICE_ERROR;\r
599 }\r
600 if (!IsWithinOneDay (&RtcTime, Time)) {\r
601 return EFI_UNSUPPORTED;\r
602 }\r
603 //\r
604 // Make a local copy of the time and date\r
605 //\r
606 CopyMem (&RtcTime, Time, sizeof (EFI_TIME));\r
607\r
608 }\r
609 //\r
610 // Acquire RTC Lock to make access to RTC atomic\r
611 //\r
612 //Code here doesn't consider the runtime environment.\r
613 if (!EfiAtRuntime ()) {\r
614 EfiAcquireLock (&Global->RtcLock);\r
615 }\r
616 //\r
617 // Wait for up to 0.1 seconds for the RTC to be updated\r
618 //\r
619 Status = RtcWaitToUpdate (PcdGet32 (PcdRealTimeClockUpdateTimeout));\r
620 if (EFI_ERROR (Status)) {\r
621 //Code here doesn't consider the runtime environment.\r
622 if (!EfiAtRuntime ()) {\r
623 EfiReleaseLock (&Global->RtcLock);\r
624 }\r
625 return EFI_DEVICE_ERROR;\r
626 }\r
627 //\r
628 // Read Register B, and inhibit updates of the RTC\r
629 //\r
630 RegisterB.Data = RtcRead (RTC_ADDRESS_REGISTER_B);\r
631\r
632 RegisterB.Bits.SET = 1;\r
633 RtcWrite (RTC_ADDRESS_REGISTER_B, RegisterB.Data);\r
634\r
635 if (Enable) {\r
636 ConvertEfiTimeToRtcTime (&RtcTime, RegisterB, &Century);\r
637\r
638 //\r
639 // Set RTC alarm time\r
640 //\r
641 RtcWrite (RTC_ADDRESS_SECONDS_ALARM, RtcTime.Second);\r
642 RtcWrite (RTC_ADDRESS_MINUTES_ALARM, RtcTime.Minute);\r
643 RtcWrite (RTC_ADDRESS_HOURS_ALARM, RtcTime.Hour);\r
644\r
645 RegisterB.Bits.AIE = 1;\r
646\r
647 } else {\r
648 RegisterB.Bits.AIE = 0;\r
649 }\r
650 //\r
651 // Allow updates of the RTC registers\r
652 //\r
653 RegisterB.Bits.SET = 0;\r
654 RtcWrite (RTC_ADDRESS_REGISTER_B, RegisterB.Data);\r
655\r
656 //\r
657 // Release RTC Lock.\r
658 //\r
659 //Code here doesn't consider the runtime environment.\r
660 if (!EfiAtRuntime ()) {\r
661 EfiReleaseLock (&Global->RtcLock);\r
662 }\r
663 return EFI_SUCCESS;\r
664}\r
665\r
666/**\r
667 See if century register of RTC is valid.\r
668\r
669 @retval EFI_SUCCESS Century register is valid.\r
670 @retval EFI_DEVICE_ERROR Century register is NOT valid.\r
671**/\r
672EFI_STATUS\r
673RtcTestCenturyRegister (\r
674 VOID\r
675 )\r
676{\r
677 UINT8 Century;\r
678 UINT8 Temp;\r
679\r
680 Century = RtcRead (RTC_ADDRESS_CENTURY);\r
681 Temp = (UINT8) (RtcRead (RTC_ADDRESS_CENTURY) & 0x7f);\r
682 RtcWrite (RTC_ADDRESS_CENTURY, Century);\r
683 if (Temp == 0x19 || Temp == 0x20) {\r
684 return EFI_SUCCESS;\r
685 }\r
686\r
687 return EFI_DEVICE_ERROR;\r
688}\r
689\r
690/**\r
691 Checks an 8-bit BCD value, and converts to an 8-bit value if valid.\r
692\r
693 This function checks the 8-bit BCD value specified by Value.\r
694 If valid, the function converts it to an 8-bit value and returns it.\r
695 Otherwise, return 0xff.\r
696\r
697 @param Value The 8-bit BCD value to check and convert\r
698\r
699 @return The 8-bit value converted. Or 0xff if Value is invalid.\r
700\r
701**/\r
702UINT8\r
703CheckAndConvertBcd8ToDecimal8 (\r
704 IN UINT8 Value\r
705 )\r
706{\r
707 if ((Value < 0xa0) && ((Value & 0xf) < 0xa)) {\r
708 return BcdToDecimal8 (Value);\r
709 }\r
710\r
711 return 0xff;\r
712}\r
713\r
714/**\r
715 Converts time read from RTC to EFI_TIME format defined by UEFI spec.\r
716\r
717 This function converts raw time data read from RTC to the EFI_TIME format\r
718 defined by UEFI spec.\r
719 If data mode of RTC is BCD, then converts it to decimal,\r
720 If RTC is in 12-hour format, then converts it to 24-hour format.\r
721\r
722 @param Time On input, the time data read from RTC to convert\r
723 On output, the time converted to UEFI format\r
724 @param Century Value of century read from RTC.\r
725 @param RegisterB Value of Register B of RTC, indicating data mode\r
726 and hour format.\r
727\r
728 @retval EFI_INVALID_PARAMETER Parameters passed in are invalid.\r
729 @retval EFI_SUCCESS Convert RTC time to EFI time successfully.\r
730\r
731**/\r
732EFI_STATUS\r
733ConvertRtcTimeToEfiTime (\r
734 IN OUT EFI_TIME *Time,\r
735 IN UINT8 Century,\r
736 IN RTC_REGISTER_B RegisterB\r
737 )\r
738{\r
739 BOOLEAN IsPM;\r
740\r
741 if ((Time->Hour & 0x80) != 0) {\r
742 IsPM = TRUE;\r
743 } else {\r
744 IsPM = FALSE;\r
745 }\r
746\r
747 Time->Hour = (UINT8) (Time->Hour & 0x7f);\r
748\r
749 if (RegisterB.Bits.DM == 0) {\r
750 Time->Year = CheckAndConvertBcd8ToDecimal8 ((UINT8) Time->Year);\r
751 Time->Month = CheckAndConvertBcd8ToDecimal8 (Time->Month);\r
752 Time->Day = CheckAndConvertBcd8ToDecimal8 (Time->Day);\r
753 Time->Hour = CheckAndConvertBcd8ToDecimal8 (Time->Hour);\r
754 Time->Minute = CheckAndConvertBcd8ToDecimal8 (Time->Minute);\r
755 Time->Second = CheckAndConvertBcd8ToDecimal8 (Time->Second);\r
756 Century = CheckAndConvertBcd8ToDecimal8 (Century);\r
757 }\r
758\r
759 if (Time->Year == 0xff || Time->Month == 0xff || Time->Day == 0xff ||\r
760 Time->Hour == 0xff || Time->Minute == 0xff || Time->Second == 0xff ||\r
761 Century == 0xff) {\r
762 return EFI_INVALID_PARAMETER;\r
763 }\r
764\r
765 Time->Year = (UINT16) (Century * 100 + Time->Year);\r
766\r
767 //\r
768 // If time is in 12 hour format, convert it to 24 hour format\r
769 //\r
770 if (RegisterB.Bits.MIL == 0) {\r
771 if (IsPM && Time->Hour < 12) {\r
772 Time->Hour = (UINT8) (Time->Hour + 12);\r
773 }\r
774\r
775 if (!IsPM && Time->Hour == 12) {\r
776 Time->Hour = 0;\r
777 }\r
778 }\r
779\r
780 Time->Nanosecond = 0;\r
781 Time->TimeZone = EFI_UNSPECIFIED_TIMEZONE;\r
782 Time->Daylight = 0;\r
783\r
784 return EFI_SUCCESS;\r
785}\r
786\r
787/**\r
788 Wait for a period for the RTC to be ready.\r
789\r
790 @param Timeout Tell how long it should take to wait.\r
791\r
792 @retval EFI_DEVICE_ERROR RTC device error.\r
793 @retval EFI_SUCCESS RTC is updated and ready. \r
794**/\r
795EFI_STATUS\r
796RtcWaitToUpdate (\r
797 UINTN Timeout\r
798 )\r
799{\r
800 RTC_REGISTER_A RegisterA;\r
801 RTC_REGISTER_D RegisterD;\r
802\r
803 //\r
804 // See if the RTC is functioning correctly\r
805 //\r
806 RegisterD.Data = RtcRead (RTC_ADDRESS_REGISTER_D);\r
807\r
808 if (RegisterD.Bits.VRT == 0) {\r
809 return EFI_DEVICE_ERROR;\r
810 }\r
811 //\r
812 // Wait for up to 0.1 seconds for the RTC to be ready.\r
813 //\r
814 Timeout = (Timeout / 10) + 1;\r
815 RegisterA.Data = RtcRead (RTC_ADDRESS_REGISTER_A);\r
816 while (RegisterA.Bits.UIP == 1 && Timeout > 0) {\r
817 MicroSecondDelay (10);\r
818 RegisterA.Data = RtcRead (RTC_ADDRESS_REGISTER_A);\r
819 Timeout--;\r
820 }\r
821\r
822 RegisterD.Data = RtcRead (RTC_ADDRESS_REGISTER_D);\r
823 if (Timeout == 0 || RegisterD.Bits.VRT == 0) {\r
824 return EFI_DEVICE_ERROR;\r
825 }\r
826\r
827 return EFI_SUCCESS;\r
828}\r
829\r
830/**\r
831 See if all fields of a variable of EFI_TIME type is correct.\r
832\r
833 @param Time The time to be checked.\r
834\r
835 @retval EFI_INVALID_PARAMETER Some fields of Time are not correct.\r
836 @retval EFI_SUCCESS Time is a valid EFI_TIME variable.\r
837\r
838**/\r
839EFI_STATUS\r
840RtcTimeFieldsValid (\r
841 IN EFI_TIME *Time\r
842 )\r
843{\r
844 if (Time->Year < 1998 ||\r
845 Time->Year > 2099 ||\r
846 Time->Month < 1 ||\r
847 Time->Month > 12 ||\r
848 Time->Hour > 23 ||\r
849 Time->Minute > 59 ||\r
850 Time->Second > 59 ||\r
851 Time->Nanosecond > 999999999 ||\r
852 (!(Time->TimeZone == EFI_UNSPECIFIED_TIMEZONE || (Time->TimeZone >= -1440 && Time->TimeZone <= 1440))) ||\r
853 ((Time->Daylight & (~(EFI_TIME_ADJUST_DAYLIGHT | EFI_TIME_IN_DAYLIGHT))) != 0)\r
854 ) {\r
855 if (!DayValid (Time)) {\r
856 return EFI_INVALID_PARAMETER;\r
857 }\r
858 }\r
859\r
860 return EFI_SUCCESS;\r
861}\r
862\r
863/**\r
864 See if field Day of an EFI_TIME is correct.\r
865\r
866 @param Time Its Day field is to be checked.\r
867\r
868 @retval TRUE Day field of Time is correct.\r
869 @retval FALSE Day field of Time is NOT correct.\r
870**/\r
871BOOLEAN\r
872DayValid (\r
873 IN EFI_TIME *Time\r
874 )\r
875{\r
876 INTN DayOfMonth[12];\r
877\r
878 DayOfMonth[0] = 31;\r
879 DayOfMonth[1] = 29;\r
880 DayOfMonth[2] = 31;\r
881 DayOfMonth[3] = 30;\r
882 DayOfMonth[4] = 31;\r
883 DayOfMonth[5] = 30;\r
884 DayOfMonth[6] = 31;\r
885 DayOfMonth[7] = 31;\r
886 DayOfMonth[8] = 30;\r
887 DayOfMonth[9] = 31;\r
888 DayOfMonth[10] = 30;\r
889 DayOfMonth[11] = 31;\r
890\r
891 //\r
892 // The validity of Time->Month field should be checked before\r
893 //\r
894 ASSERT (Time->Month >=1);\r
895 ASSERT (Time->Month <=12);\r
896 if (Time->Day < 1 ||\r
897 Time->Day > DayOfMonth[Time->Month - 1] ||\r
898 (Time->Month == 2 && (!IsLeapYear (Time) && Time->Day > 28))\r
899 ) {\r
900 return FALSE;\r
901 }\r
902\r
903 return TRUE;\r
904}\r
905\r
906/**\r
907 Check if it is a leap year.\r
908\r
909 @param Time The time to be checked.\r
910\r
911 @retval TRUE It is a leap year.\r
912 @retval FALSE It is NOT a leap year.\r
913**/\r
914BOOLEAN\r
915IsLeapYear (\r
916 IN EFI_TIME *Time\r
917 )\r
918{\r
919 if (Time->Year % 4 == 0) {\r
920 if (Time->Year % 100 == 0) {\r
921 if (Time->Year % 400 == 0) {\r
922 return TRUE;\r
923 } else {\r
924 return FALSE;\r
925 }\r
926 } else {\r
927 return TRUE;\r
928 }\r
929 } else {\r
930 return FALSE;\r
931 }\r
932}\r
933\r
934/**\r
935 Converts time from EFI_TIME format defined by UEFI spec to RTC's.\r
936\r
937 This function converts time from EFI_TIME format defined by UEFI spec to RTC's.\r
938 If data mode of RTC is BCD, then converts EFI_TIME to it.\r
939 If RTC is in 12-hour format, then converts EFI_TIME to it.\r
940\r
941 @param Time On input, the time data read from UEFI to convert\r
942 On output, the time converted to RTC format\r
943 @param RegisterB Value of Register B of RTC, indicating data mode\r
944 @param Century It is set according to EFI_TIME Time.\r
945\r
946**/\r
947VOID\r
948ConvertEfiTimeToRtcTime (\r
949 IN OUT EFI_TIME *Time,\r
950 IN RTC_REGISTER_B RegisterB,\r
951 OUT UINT8 *Century\r
952 )\r
953{\r
954 BOOLEAN IsPM;\r
955\r
956 IsPM = TRUE;\r
957 //\r
958 // Adjust hour field if RTC is in 12 hour mode\r
959 //\r
960 if (RegisterB.Bits.MIL == 0) {\r
961 if (Time->Hour < 12) {\r
962 IsPM = FALSE;\r
963 }\r
964\r
965 if (Time->Hour >= 13) {\r
966 Time->Hour = (UINT8) (Time->Hour - 12);\r
967 } else if (Time->Hour == 0) {\r
968 Time->Hour = 12;\r
969 }\r
970 }\r
971 //\r
972 // Set the Time/Date/Daylight Savings values.\r
973 //\r
974 *Century = DecimalToBcd8 ((UINT8) (Time->Year / 100));\r
975\r
976 Time->Year = (UINT16) (Time->Year % 100);\r
977\r
978 if (RegisterB.Bits.DM == 0) {\r
979 Time->Year = DecimalToBcd8 ((UINT8) Time->Year);\r
980 Time->Month = DecimalToBcd8 (Time->Month);\r
981 Time->Day = DecimalToBcd8 (Time->Day);\r
982 Time->Hour = DecimalToBcd8 (Time->Hour);\r
983 Time->Minute = DecimalToBcd8 (Time->Minute);\r
984 Time->Second = DecimalToBcd8 (Time->Second);\r
985 }\r
986 //\r
987 // If we are in 12 hour mode and PM is set, then set bit 7 of the Hour field.\r
988 //\r
989 if (RegisterB.Bits.MIL == 0 && IsPM) {\r
990 Time->Hour = (UINT8) (Time->Hour | 0x80);\r
991 }\r
992}\r
993\r
994/**\r
995 Compare the Hour, Minute and Second of the From time and the To time.\r
996 \r
997 Only compare H/M/S in EFI_TIME and ignore other fields here.\r
998\r
999 @param From the first time\r
1000 @param To the second time\r
1001\r
1002 @return >0 The H/M/S of the From time is later than those of To time\r
1003 @return ==0 The H/M/S of the From time is same as those of To time\r
1004 @return <0 The H/M/S of the From time is earlier than those of To time\r
1005**/\r
1006INTN\r
1007CompareHMS (\r
1008 IN EFI_TIME *From,\r
1009 IN EFI_TIME *To\r
1010 )\r
1011{\r
1012 if ((From->Hour > To->Hour) ||\r
1013 ((From->Hour == To->Hour) && (From->Minute > To->Minute)) ||\r
1014 ((From->Hour == To->Hour) && (From->Minute == To->Minute) && (From->Second > To->Second))) {\r
1015 return 1;\r
1016 } else if ((From->Hour == To->Hour) && (From->Minute == To->Minute) && (From->Second == To->Second)) {\r
1017 return 0;\r
1018 } else {\r
1019 return -1;\r
1020 }\r
1021}\r
1022\r
1023/**\r
1024 To check if second date is later than first date within 24 hours.\r
1025\r
1026 @param From the first date\r
1027 @param To the second date\r
1028\r
1029 @retval TRUE From is previous to To within 24 hours.\r
1030 @retval FALSE From is later, or it is previous to To more than 24 hours.\r
1031**/\r
1032BOOLEAN\r
1033IsWithinOneDay (\r
1034 IN EFI_TIME *From,\r
1035 IN EFI_TIME *To\r
1036 )\r
1037{\r
1038 UINT8 DayOfMonth[12];\r
1039 BOOLEAN Adjacent;\r
1040\r
1041 DayOfMonth[0] = 31;\r
1042 DayOfMonth[1] = 29;\r
1043 DayOfMonth[2] = 31;\r
1044 DayOfMonth[3] = 30;\r
1045 DayOfMonth[4] = 31;\r
1046 DayOfMonth[5] = 30;\r
1047 DayOfMonth[6] = 31;\r
1048 DayOfMonth[7] = 31;\r
1049 DayOfMonth[8] = 30;\r
1050 DayOfMonth[9] = 31;\r
1051 DayOfMonth[10] = 30;\r
1052 DayOfMonth[11] = 31;\r
1053\r
1054 Adjacent = FALSE;\r
1055\r
1056 //\r
1057 // The validity of From->Month field should be checked before\r
1058 //\r
1059 ASSERT (From->Month >=1);\r
1060 ASSERT (From->Month <=12);\r
1061 \r
1062 if (From->Year == To->Year) {\r
1063 if (From->Month == To->Month) {\r
1064 if ((From->Day + 1) == To->Day) {\r
1065 if ((CompareHMS(From, To) >= 0)) {\r
1066 Adjacent = TRUE;\r
1067 }\r
1068 } else if (From->Day == To->Day) {\r
1069 if ((CompareHMS(From, To) <= 0)) {\r
1070 Adjacent = TRUE;\r
1071 }\r
1072 }\r
1073 } else if (((From->Month + 1) == To->Month) && (To->Day == 1)) {\r
1074 if ((From->Month == 2) && !IsLeapYear(From)) {\r
1075 if (From->Day == 28) {\r
1076 if ((CompareHMS(From, To) >= 0)) {\r
1077 Adjacent = TRUE;\r
1078 }\r
1079 }\r
1080 } else if (From->Day == DayOfMonth[From->Month - 1]) {\r
1081 if ((CompareHMS(From, To) >= 0)) {\r
1082 Adjacent = TRUE;\r
1083 }\r
1084 }\r
1085 }\r
1086 } else if (((From->Year + 1) == To->Year) &&\r
1087 (From->Month == 12) &&\r
1088 (From->Day == 31) &&\r
1089 (To->Month == 1) &&\r
1090 (To->Day == 1)) {\r
1091 if ((CompareHMS(From, To) >= 0)) {\r
1092 Adjacent = TRUE;\r
1093 }\r
1094 }\r
1095\r
1096 return Adjacent;\r
1097}\r
1098\r