Commit | Line | Data |
---|---|---|
1 | ------------------------------------- | |
2 | iSCSI Initiator for Microsoft Windows | |
3 | ------------------------------------- | |
4 | ||
5 | **Prerequisite:** | |
6 | ||
7 | - Microsoft Windows Server 2016 | |
8 | ||
9 | **iSCSI Initiator, Discovery and Setup:** | |
10 | ||
11 | #. Install the iSCSI initiator driver and MPIO tools. | |
12 | ||
13 | #. Launch the MPIO program, click on the "Discover Multi-Paths" tab, check the | |
14 | "Add support for iSCSI devices” box, and click "Add". This will require a | |
15 | reboot. | |
16 | ||
17 | #. On the iSCSI Initiator Properties window, on the "Discovery" tab, add a target | |
18 | portal. Enter the IP address or DNS name and Port of the Ceph iSCSI gateway. | |
19 | ||
20 | #. On the “Targets” tab, select the target and click on “Connect”. | |
21 | ||
22 | #. On the “Connect To Target” window, select the “Enable multi-path” option, and | |
23 | click the “Advanced” button. | |
24 | ||
25 | #. Under the "Connet using" section, select a “Target portal IP” . Select the | |
26 | “Enable CHAP login on” and enter the "Name" and "Target secret" values from the | |
27 | Ceph iSCSI Ansible client credentials section, and click OK. | |
28 | ||
29 | #. Repeat steps 5 and 6 for each target portal defined when setting up | |
30 | the iSCSI gateway. | |
31 | ||
32 | **Multipath IO Setup:** | |
33 | ||
34 | Configuring the MPIO load balancing policy, setting the timeout and | |
35 | retry options are using PowerShell with the ``mpclaim`` command. The | |
36 | rest is done in the iSCSI Initiator tool. | |
37 | ||
38 | .. note:: | |
39 | It is recommended to increase the ``PDORemovePeriod`` option to 120 | |
40 | seconds from PowerShell. This value might need to be adjusted based | |
41 | on the application. When all paths are down, and 120 seconds | |
42 | expires, the operating system will start failing IO requests. | |
43 | ||
44 | :: | |
45 | ||
46 | Set-MPIOSetting -NewPDORemovePeriod 120 | |
47 | ||
48 | :: | |
49 | ||
50 | mpclaim.exe -l -m 1 | |
51 | ||
52 | :: | |
53 | ||
54 | mpclaim -s -m | |
55 | MSDSM-wide Load Balance Policy: Fail Over Only | |
56 | ||
57 | #. Using the iSCSI Initiator tool, from the “Targets” tab, click on | |
58 | the “Devices...” button. | |
59 | ||
60 | #. From the Devices window, select a disk and click the | |
61 | “MPIO...” button. | |
62 | ||
63 | #. On the "Device Details" window the paths to each target portal is | |
64 | displayed. If using the ``ceph-ansible`` setup method, the | |
65 | iSCSI gateway will use ALUA to tell the iSCSI initiator which path | |
66 | and iSCSI gateway should be used as the primary path. The Load | |
67 | Balancing Policy “Fail Over Only” must be selected | |
68 | ||
69 | :: | |
70 | ||
71 | mpclaim -s -d $MPIO_DISK_ID | |
72 | ||
73 | .. note:: | |
74 | For the ``ceph-ansible`` setup method, there will be one | |
75 | Active/Optimized path which is the path to the iSCSI gateway node | |
76 | that owns the LUN, and there will be an Active/Unoptimized path for | |
77 | each other iSCSI gateway node. | |
78 | ||
79 | **Tuning:** | |
80 | ||
81 | Consider using the following registry settings: | |
82 | ||
83 | - Windows Disk Timeout | |
84 | ||
85 | :: | |
86 | ||
87 | HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\Disk | |
88 | ||
89 | :: | |
90 | ||
91 | TimeOutValue = 65 | |
92 | ||
93 | - Microsoft iSCSI Initiator Driver | |
94 | ||
95 | :: | |
96 | ||
97 | HKEY_LOCAL_MACHINE\\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}\<Instance_Number>\Parameters | |
98 | ||
99 | :: | |
100 | LinkDownTime = 25 | |